Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. pradeeka1 +XWiki.Xiaoling - Content
-
... ... @@ -27,7 +27,7 @@ 27 27 **This manual is also applicable to the LT-33222-L.** 28 28 {{/info}} 29 29 30 -The Dragino (% style="color:blue" %)**LT-22222-L I/O Controller**(%%) is an advanced LoRaWAN device designed to provide seamless wireless long-range connectivity with various I/O options, including analog current and voltage inputs, digital inputs and outputs, and relay outputs. 30 +The Dragino (% style="color:blue" %)**LT-22222-L I/O Controller**(%%) is an advanced LoRaWAN end device designed to provide seamless wireless long-range connectivity with various I/O options, including analog current and voltage inputs, digital inputs and outputs, and relay outputs. 31 31 32 32 The LT-22222-L I/O Controller simplifies and enhances I/O monitoring and controlling. It is ideal for professional applications in wireless sensor networks, including irrigation systems, smart metering, smart cities, building automation, and more. These controllers are designed for easy, cost-effective deployment using LoRa wireless technology. 33 33 ))) ... ... @@ -40,23 +40,24 @@ 40 40 ((( 41 41 You can connect the LT-22222-L I/O Controller to a LoRaWAN network service provider in several ways: 42 42 43 -* If there is public LoRaWAN network coverage in the area where you plan to install the device (e.g., The Things Network), you can select a network and register the LT-22222-L I/O controller with it. 43 +* If there is public LoRaWAN network coverage in the area where you plan to install the device (e.g., The Things Stack Community Network), you can select a network and register the LT-22222-L I/O controller with it. 44 44 * If there is no public LoRaWAN coverage in your area, you can set up a LoRaWAN gateway, or multiple gateways, and connect them to a LoRaWAN network server to create adequate coverage. Then, register the LT-22222-L I/O controller with this network. 45 45 * Setup your own private LoRaWAN network. 46 - 47 -{{info}} 48 - You can use a LoRaWAN gateway, such as the [[Dragino LG308>>https://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], to expand or create LoRaWAN coverage in your area. 49 -{{/info}} 50 50 ))) 51 51 52 52 ((( 53 -[[image:1653295757274-912.png]] 54 - 55 55 50 + 51 +The network diagram below illustrates how the LT-22222-L communicates with a typical LoRaWAN network. 56 56 ))) 57 57 54 +(% class="wikigeneratedid" %) 55 +[[image:lorawan-nw.jpg||height="354" width="900"]] 56 + 57 + 58 58 == 1.2 Specifications == 59 59 60 + 60 60 (% style="color:#037691" %)**Hardware System:** 61 61 62 62 * STM32L072xxxx MCU ... ... @@ -115,24 +115,41 @@ 115 115 * Smart cities 116 116 * Smart factory 117 117 118 -== 2.Assemblingthedevice==119 +== 1.5 Hardware Variants == 119 119 121 + 122 +(% border="1" cellspacing="3" style="width:510px" %) 123 +|(% style="width:94px" %)**Model**|(% style="width:172px" %)**Photo**|(% style="width:244px" %)**Description** 124 +|(% style="width:94px" %)**LT-33222-L**|(% style="width:172px" %)((( 125 +(% style="text-align:center" %) 126 +[[image:lt33222-l.jpg||height="139" width="120"]] 127 +)))|(% style="width:256px" %)((( 128 +* 3 x Digital Input (Bi-direction) 129 +* 3 x Digital Output 130 +* 2 x Relay Output (5A@250VAC / 30VDC) 131 +* 2 x 0~~20mA Analog Input (res:0.01mA) 132 +* 2 x 0~~30V Analog Input (res:0.01v) 133 +* 1 x Counting Port 134 +))) 135 + 136 += 2. Assembling the device = 137 + 120 120 == 2.1 Connecting the antenna == 121 121 122 122 Connect the LoRa antenna to the antenna connector, **ANT**,** **located on the top right side of the device, next to the upper screw terminal block. Secure the antenna by tightening it clockwise. 123 123 124 124 {{warning}} 125 -Warning! Do not power on the device without connecting the antenna. 143 +**Warning! Do not power on the device without connecting the antenna.** 126 126 {{/warning}} 127 127 128 128 == 2.2 Terminals == 129 129 130 -The LT-22222-L has two screw terminal blocks. The upper screw treminal block has 6 terminals and the lower screw terminal block has 10 terminals. 148 +The LT-22222-L has two screw terminal blocks. The upper screw treminal block has 6 screw terminals and the lower screw terminal block has 10 screw terminals. 131 131 132 -Upper screw terminal block (from left to right): 150 +**Upper screw terminal block (from left to right):** 133 133 134 134 (% style="width:634px" %) 135 -|=(% style="width: 295px;" %)Terminal|=(% style="width: 338px;" %)Function 153 +|=(% style="width: 295px;" %)Screw Terminal|=(% style="width: 338px;" %)Function 136 136 |(% style="width:295px" %)GND|(% style="width:338px" %)Ground 137 137 |(% style="width:295px" %)VIN|(% style="width:338px" %)Input Voltage 138 138 |(% style="width:295px" %)AVI2|(% style="width:338px" %)Analog Voltage Input Terminal 2 ... ... @@ -140,10 +140,10 @@ 140 140 |(% style="width:295px" %)ACI2|(% style="width:338px" %)Analog Current Input Terminal 2 141 141 |(% style="width:295px" %)ACI1|(% style="width:338px" %)Analog Current Input Terminal 1 142 142 143 -Lower screw terminal block (from left to right): 161 +**Lower screw terminal block (from left to right):** 144 144 145 145 (% style="width:633px" %) 146 -|=(% style="width: 296px;" %)Terminal|=(% style="width: 334px;" %)Function 164 +|=(% style="width: 296px;" %)Screw Terminal|=(% style="width: 334px;" %)Function 147 147 |(% style="width:296px" %)RO1-2|(% style="width:334px" %)Relay Output 1 148 148 |(% style="width:296px" %)RO1-1|(% style="width:334px" %)Relay Output 1 149 149 |(% style="width:296px" %)RO2-2|(% style="width:334px" %)Relay Output 2 ... ... @@ -155,14 +155,12 @@ 155 155 |(% style="width:296px" %)DO2|(% style="width:334px" %)Digital Output 2 156 156 |(% style="width:296px" %)DO1|(% style="width:334px" %)Digital Output 1 157 157 158 -== 2.3 Powering thedevice ==176 +== 2.3 Connecting LT-22222-L to a Power Source == 159 159 160 -The LT-22222-L I/O Controller can be powered by a **7–24V DC** power source. Connect your power supply’s positive wire to the VIN and the negative wire to the GND screw terminals. The power indicator **(PWR) LED** will turn on when the device is properly powered. 178 +The LT-22222-L I/O Controller can be powered by a **7–24V DC** power source. Connect your power supply’s **positive wire** to the **VIN** and the **negative wire** to the **GND** screw terminals. The power indicator **(PWR) LED** will turn on when the device is properly powered. 161 161 162 -Once powered, the **TX LED** will **fast-blink 5 times** which means the LT-22222-L will enter the **work mode** and start to **join** The Things Stack. The **TX LED** will be on for **5 seconds** after joining the network. When there is a **downlink** message from the server, the **RX LED** will be on for **1 second**. When the device is sending an uplink message to the server, the **TX LED** will be on for **1 second**. See also LED status. 163 - 164 164 {{warning}} 165 -We recommend that you power on the LT-22222-L after configuring its registration information with a LoRaWAN network server. Otherwise, the device will continuously send join-request messages to attempt to join a LoRaWAN network but will fail. 181 +**We recommend that you power on the LT-22222-L after configuring its registration information with a LoRaWAN network server. Otherwise, the device will continuously send join-request messages to attempt to join a LoRaWAN network but will fail.** 166 166 {{/warning}} 167 167 168 168 ... ... @@ -169,36 +169,51 @@ 169 169 [[image:1653297104069-180.png]] 170 170 171 171 172 -= 3. Registering with a LoRaWAN Network Server = 188 += 3. Registering LT-22222-L with a LoRaWAN Network Server = 173 173 174 - By default, the LT-22222-Lisconfigured to operate in LoRaWAN ClassC mode. ItsupportsOTAA (Over-the-Air Activation),themostsecuremethodforactivating a devicewith a LoRaWANnetworkserver.TheLT-22222-Lcomeswithdeviceregistrationinformation that allowsyou to registeritwith a LoRaWANnetwork,enabling the deviceto performOTAA activation with thenetworkserverupon initialpower-upand after any subsequent reboots.190 +The LT-22222-L supports both OTAA (Over-the-Air Activation) and ABP (Activation By Personalization) methods to activate with a LoRaWAN Network Server. However, OTAA is the most secure method for activating a device with a LoRaWAN Network Server. OTAA regenerates session keys upon initial registration and regenerates new session keys after any subsequent reboots. By default, the LT-22222-L is configured to operate in LoRaWAN Class C mode. 175 175 176 -After powering on, the **TX LED** will **fast-blink 5 times** which means the LT-22222-L will enter the **work mode** and start to **join** the LoRaWAN network. The **TX LED** will be on for **5 seconds** after joining the network. When there is a **downlink** message from the server, the **RX LED** will be on for **1 second**. When the device is sending an uplink message to the server, the **TX LED** will be on for **1 second**. See also LED status. 177 177 178 -In case you can't set the root key and other identifiers in the network server and must use them from the server, you can use [[AT Commands>>||anchor="H4.UseATCommand"]] to configure them on the device. 179 - 180 -The network diagram below shows how the LT-22222-L is connected to a typical LoRaWAN network. 181 - 182 -[[image:image-20220523172350-1.png||height="266" width="864"]] 183 - 184 184 === 3.2.1 Prerequisites === 185 185 186 - Makesureyou have thedevice registration information such as DevEUI, AppEUI, and AppKeywith you. The registration information can be found on a sticker that can be found inside the package. Please keep the **registration information** sticker in a safe place for future reference.195 +The LT-22222-L comes with device registration information such as DevEUI, AppEUI, and AppKey that allows you to register it with a LoRaWAN network. These registration information can be found on a sticker that can be found inside the package. Please keep the **registration information** sticker in a safe place for future reference. 187 187 188 188 [[image:image-20230425173427-2.png||height="246" width="530"]] 189 189 199 +{{info}} 200 +In case you can't set the root key and other identifiers in the network server and must use them from the server, you can use [[AT Commands>>||anchor="H4.UseATCommand"]] to configure them on the device. 201 +{{/info}} 202 + 190 190 The following subsections explain how to register the LT-22222-L with different LoRaWAN network server providers. 191 191 192 -=== 3.2.2 The Things Stack Sandbox (TTSS)===205 +=== 3.2.2 The Things Stack === 193 193 207 +This section guides you through how to register your LT-22222-L with The Things Stack Sandbox. 208 + 209 +{{info}} 194 194 The Things Stack Sandbox was formally called The Things Stack Community Edition. 211 +{{/info}} 195 195 196 -* Log in to your [[The Things Stack Sandbox>>https://eu1.cloud.thethings.network]] account. 197 -* Create an application with The Things Stack if you do not have one yet. 198 -* Go to your application page and click on the **End devices** in the left menu. 213 + 214 +The network diagram below illustrates the connection between the LT-22222-L and The Things Stack, as well as how the data can be integrated with the ThingsEye IoT platform. 215 + 216 + 217 +[[image:dragino-lorawan-nw-lt-22222-n.jpg]] 218 + 219 +{{info}} 220 + You can use a LoRaWAN gateway, such as the [[Dragino LPS8N>>https://www.dragino.com/products/lora-lorawan-gateway/item/200-lps8n.html]], to expand or create LoRaWAN coverage in your area. 221 +{{/info}} 222 + 223 + 224 +==== 3.2.2.1 Setting up ==== 225 + 226 +* Sign up for a free account with [[The Things Stack Sandbox>>https://eu1.cloud.thethings.network]] if you do not have one yet. 227 +* Log in to your The Things Stack Sandbox account. 228 +* Create an **application** with The Things Stack if you do not have one yet (E.g., dragino-docs). 229 +* Go to your application's page and click on the **End devices** in the left menu. 199 199 * On the End devices page, click on **+ Register end device**. Two registration options are available: 200 200 201 -==== 3.2.2. 1Using the LoRaWAN Device Repository ====232 +==== 3.2.2.2 Using the LoRaWAN Device Repository ==== 202 202 203 203 * On the **Register end device** page: 204 204 ** Select the option **Select the end device in the LoRaWAN Device Repository **under **Input method**. ... ... @@ -210,7 +210,7 @@ 210 210 *** **Profile (Region)**: Select the region that matches your device. 211 211 ** Select the **Frequency plan** that matches your device from the **Frequency plan** dropdown list. 212 212 213 -[[image:lt-22222-l-dev-repo-reg-p1.png ||height="625" width="1000"]]244 +[[image:lt-22222-l-dev-repo-reg-p1.png]] 214 214 215 215 216 216 * Register end device page continued... ... ... @@ -220,11 +220,10 @@ 220 220 ** In the **End device ID** field, enter a unique name for your LT-22222-N within this application. 221 221 ** Under **After registration**, select the **View registered end device** option. 222 222 223 -[[image:lt-22222-l-dev-repo-reg-p2.png ||height="625" width="1000"]]254 +[[image:lt-22222-l-dev-repo-reg-p2.png]] 224 224 225 -==== ==== 226 226 227 -==== 3.2.2. 2Adding device manually ====257 +==== 3.2.2.3 Adding device manually ==== 228 228 229 229 * On the **Register end device** page: 230 230 ** Select the option **Enter end device specifies manually** under **Input method**. ... ... @@ -235,11 +235,11 @@ 235 235 ** Select the option **Over the air activation (OTAA)** under the **Activation mode.** 236 236 ** Select **Class C (Continuous)** from the **Additional LoRaWAN class capabilities** dropdown list. 237 237 238 -[[image:lt-22222-l-manually-p1.png ||height="625" width="1000"]]268 +[[image:lt-22222-l-manually-p1.png]] 239 239 240 240 241 241 * Register end device page continued... 242 -** Enter the **AppEUI** in the **JoinEUI** field and click the **Confirm** button. If The Things Stack accepts the JoinEUI you provided, it will display the message 'This end device can be registered on the network' 272 +** Enter the **AppEUI** in the **JoinEUI** field and click the **Confirm** button. If The Things Stack accepts the JoinEUI you provided, it will display the message '//**This end device can be registered on the network**//' 243 243 ** In the **DevEUI** field, enter the **DevEUI**. 244 244 ** In the **AppKey** field, enter the **AppKey**. 245 245 ** In the **End device ID** field, enter a unique name for your LT-22222-N within this application. ... ... @@ -246,41 +246,50 @@ 246 246 ** Under **After registration**, select the **View registered end device** option. 247 247 ** Click the **Register end device** button. 248 248 249 -[[image:lt-22222-l-manually-p2.png ||height="625" width="1000"]]279 +[[image:lt-22222-l-manually-p2.png]] 250 250 251 251 252 252 You will be navigated to the **Device overview** page. 253 253 254 254 255 -[[image:lt-22222-device-overview.png ||height="625" width="1000"]]285 +[[image:lt-22222-device-overview.png]] 256 256 257 257 258 -==== 3.2.2. 3Joining ====288 +==== 3.2.2.4 Joining ==== 259 259 260 -On the Device overviewpage, click on **Live data** tab. The Live data panel for your device will display.290 +On the Device's page, click on **Live data** tab. The Live data panel for your device will display. 261 261 262 -Now power on your LT-22222-L. Itwill beginjoiningThe Things Stack. In the **Live data** panel, you can see the **join-request** and **join-accept** messages exchanged between the device and the network server.Once successfully joined, the device will send its first **uplink data message** to the application it belongs to (in this example, **dragino-docs**).292 +Now power on your LT-22222-L. The **TX LED** will **fast-blink 5 times** which means the LT-22222-L will enter the **work mode** and start to **join** The Things Stack network server. The **TX LED** will be on for **5 seconds** after joining the network. In the **Live data** panel, you can see the **join-request** and **join-accept** messages exchanged between the device and the network server. 263 263 264 264 265 -[[image:lt-22222-join -network.png||height="625" width="1000"]]295 +[[image:lt-22222-l-joining.png]] 266 266 267 267 268 -By default, you will receive an uplink data message from the device every 10 minutes. 269 269 299 +==== 3.2.2.5 Uplinks ==== 300 + 301 + 302 +After successfully joining, the device will send its first **uplink data message** to the application it belongs to (in this example, **dragino-docs**). When the LT-22222-L sends an uplink message to the server, the **TX LED** turns on for **1 second**. By default, you will receive an uplink data message from the device every 10 minutes. 303 + 270 270 Click on one of a **Forward uplink data messages **to see its payload content. The payload content is encapsulated within the decode_payload {} JSON object. 271 271 272 272 [[image:lt-22222-ul-payload-decoded.png]] 273 273 274 274 275 -If you can't see the decoded payload, it is because you haven't added the uplink formatter code. To add the uplink formatter code, select **End devices** > ** LT-22222-L**309 +If you can't see the decoded payload, it is because you haven't added the uplink formatter code. To add the uplink formatter code, select **Applications > your application > End devices** > **your end device** > **Payload formatters** > **Uplink**. Then select **Use Device repository formatters** for the **Formatter type** dropdown. Click the **Save changes** button to apply the changes. 276 276 277 277 {{info}} 278 278 The Things Stack provides two levels of payload formatters: application level and device level. The device-level payload formatters **override **the application-level payload formatters. 279 279 {{/info}} 280 280 281 -[[image:lt-22222-ul-payload-fmt.png ||height="686" width="1000"]]315 +[[image:lt-22222-ul-payload-fmt.png]] 282 282 283 283 318 +==== 3.2.2.6 Downlinks ==== 319 + 320 +When the LT-22222-L receives a downlink message from the server, the **RX LED** turns on for **1 second**. 321 + 322 + 284 284 == 3.3 Working Modes and Uplink Payload formats == 285 285 286 286 ... ... @@ -556,19 +556,19 @@ 556 556 ))) 557 557 558 558 ((( 559 - OtherAT Commands for counting are similar to the [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]s.598 +AT Commands for counting are similar to the [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]s. 560 560 ))) 561 561 562 562 ((( 563 563 **In addition to that, below are the commands for AVI1 Counting:** 564 564 565 -(% style="color:blue" %)**AT+SETCNT=3,60 **(%%)**(Sets AVI Count to 60)** 604 +(% style="color:blue" %)**AT+SETCNT=3,60 **(%%)**(Sets AVI1 Count to 60)** 566 566 567 -(% style="color:blue" %)**AT+VOLMAX=20000 **(%%)**(If AVI1 voltage higher than VOLMAX (20000mV =20 v), counter increase 1)**606 +(% style="color:blue" %)**AT+VOLMAX=20000 **(%%)**(If the AVI1 voltage is higher than VOLMAX (20000mV =20V), the counter increases by 1)** 568 568 569 -(% style="color:blue" %)**AT+VOLMAX=20000,0 **(%%)**(If AVI1 voltage lower than VOLMAX (20000mV =20 v), counter increase 1)**608 +(% style="color:blue" %)**AT+VOLMAX=20000,0 **(%%)**(If the AVI1 voltage is lower than VOLMAX (20000mV =20V), counter increases by 1)** 570 570 571 -(% style="color:blue" %)**AT+VOLMAX=20000,1 **(%%)**(If AVI1 voltage higher than VOLMAX (20000mV =20 v), counter increase 1)**610 +(% style="color:blue" %)**AT+VOLMAX=20000,1 **(%%)**(If the AVI1 voltage is higher than VOLMAX (20000mV =20V), counter increases by 1)** 572 572 ))) 573 573 574 574 ... ... @@ -687,9 +687,9 @@ 687 687 688 688 (% style="color:#037691" %)**LoRaWAN Downlink Commands for Setting the Trigger Conditions:** 689 689 690 -Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 729 +**Type Code**: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 691 691 692 -Format: AA xx yy1 yy1 yy2 yy2 yy3 yy3 yy4 yy4 731 +**Format**: AA xx yy1 yy1 yy2 yy2 yy3 yy3 yy4 yy4 693 693 694 694 AA: Type Code for this downlink Command: 695 695 ... ... @@ -756,7 +756,7 @@ 756 756 757 757 **Example:** 758 758 759 -10100000: Means the systemhas configure to use the trigger:AV1_LOW and AV2_LOW798 +10100000: This means the system is configured to use the triggers AV1_LOW and AV2_LOW. 760 760 761 761 762 762 (% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1 byte as below ... ... @@ -785,7 +785,7 @@ 785 785 786 786 **Example:** 787 787 788 -10000000: Meansthisuplink is triggered by AV1_LOW.Thatmeansthe voltage is too low.827 +10000000: The uplink is triggered by AV1_LOW, indicating that the voltage is too low. 789 789 790 790 791 791 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below ... ... @@ -794,22 +794,22 @@ 794 794 |(% style="width:64px" %)**bit 7**|(% style="width:68px" %)**bit 6**|(% style="width:63px" %)**bit 5**|(% style="width:66px" %)**bit 4**|(% style="width:109px" %)**bit 3**|(% style="width:93px" %)**bit 2**|(% style="width:109px" %)**bit 1**|(% style="width:99px" %)**bit 0** 795 795 |(% style="width:64px" %)N/A|(% style="width:68px" %)N/A|(% style="width:63px" %)N/A|(% style="width:66px" %)N/A|(% style="width:109px" %)DI2_STATUS|(% style="width:93px" %)DI2_FLAG|(% style="width:109px" %)DI1_STATUS|(% style="width:99px" %)DI1_FLAG 796 796 797 -* Each bit sshows which status has been triggered on this uplink.836 +* Each bit shows which status has been triggered on this uplink. 798 798 799 799 **Example:** 800 800 801 -00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.840 +00000111: This means both DI1 and DI2 triggers are enabled, and this packet is trigger by DI1. 802 802 803 -00000101: Means both DI1 and DI2 trigger are enabled.842 +00000101: This means both DI1 and DI2 triggers are enabled. 804 804 805 805 806 -(% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable. 845 +(% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enabled. 0x00: MOD6 is disabled. 807 807 808 -Downlink command to poll MOD6 status: 847 +Downlink command to poll/request MOD6 status: 809 809 810 810 **AB 06** 811 811 812 -When device gotthis command, it will send the MOD6 payload.851 +When device receives this command, it will send the MOD6 payload. 813 813 814 814 815 815 === 3.3.7 Payload Decoder === ... ... @@ -848,7 +848,7 @@ 848 848 These commands are specially designed for the LT-22222-L. Commands can be sent to the device using options such as an AT command or a LoRaWAN downlink payload. 849 849 850 850 851 -==== 3.4.2.1 Set Transmit Interval ==== 890 +==== 3.4.2.1 Set Transmit/Uplink Interval ==== 852 852 853 853 Sets the uplink interval of the device. The default uplink transmission interval is 10 minutes. 854 854 ... ... @@ -857,11 +857,11 @@ 857 857 (% border="2" style="width:500px" %) 858 858 |**Command**|AT+TDC=<time> 859 859 |**Response**| 860 -|**Parameters**|**time** : uplink interval is in milliseconds 899 +|**Parameters**|**time** : uplink interval is in **milliseconds** 861 861 |**Example**|((( 862 862 AT+TDC=30000 863 863 864 -Sets the uplink interval to 30 ,000milliseconds (30 seconds)903 +Sets the uplink interval to **30 seconds** (30000 milliseconds) 865 865 ))) 866 866 867 867 (% style="color:#037691" %)**Downlink payload** ... ... @@ -873,16 +873,18 @@ 873 873 |**Parameters**|((( 874 874 **prefix** : 0x01 875 875 876 -**time** : uplink interval is in milliseconds, represented by 3 bytes in hexadecimal.915 +**time** : uplink interval is in **seconds**, represented by **3 bytes** in **hexadecimal**. 877 877 ))) 878 878 |**Example**|((( 879 -01 **00 75 30**918 +01 **00 00 1E** 880 880 881 -Sets the uplink interval to 30 ,000milliseconds(30 seconds)920 +Sets the uplink interval to **30 seconds** 882 882 883 -Conversion: 30 000(dec) = 0075 30 (hex)922 +Conversion: 30 (dec) = 00 00 1E (hex) 884 884 885 -See [[RapidTables>>https://www.rapidtables.com/convert/number/decimal-to-hex.html?x=30000]] 924 +See [[RapidTables>>https://www.rapidtables.com/convert/number/decimal-to-hex.html?x=30]] 925 + 926 +[[image:Screenshot 2024-11-23 at 18.27.11.png]] 886 886 ))) 887 887 888 888 ==== 3.4.2.2 Set the Working Mode (AT+MOD) ==== ... ... @@ -931,13 +931,13 @@ 931 931 Sets the device to working mode 2 (Double DI Counting + DO + RO) 932 932 ))) 933 933 934 -==== 3.4.2.3 Pollan uplink ====975 +==== 3.4.2.3 Request an uplink from the device ==== 935 935 936 -Requests an uplink from LT-22222-L. 977 +Requests an uplink from LT-22222-L. The content of the uplink payload varies based on the device's current working mode. 937 937 938 938 (% style="color:#037691" %)**AT command** 939 939 940 -There is no AT Command torequestan uplinkfrom LT-22222-L981 +There is no AT Command available for this feature. 941 941 942 942 (% style="color:#037691" %)**Downlink payload** 943 943 ... ... @@ -945,7 +945,7 @@ 945 945 |(% style="width:101px" %)**Payload**|(% style="width:397px" %)<prefix>FF 946 946 |(% style="width:101px" %)**Parameters**|(% style="width:397px" %)**prefix** : 0x08 947 947 |(% style="width:101px" %)**Example**|(% style="width:397px" %)((( 948 -08 FF 989 +08 **FF** 949 949 950 950 Requests an uplink from LT-22222-L. 951 951 ))) ... ... @@ -979,7 +979,7 @@ 979 979 |(% style="width:97px" %)**Parameters**|(% style="width:401px" %)((( 980 980 **prefix** : 0x0A 06 (two bytes in hexadecimal) 981 981 982 -** working1023 +**enable/disable trigger_mode** : enable (1) or disable (0), represented by 1 byte in hexadecimal. 983 983 ))) 984 984 |(% style="width:97px" %)**Example**|(% style="width:401px" %)((( 985 985 0A 06 **01** ... ... @@ -987,13 +987,13 @@ 987 987 Enable trigger mode for the current working mode 988 988 ))) 989 989 990 -==== 3.4.2.5 Polltrigger settings ====1031 +==== 3.4.2.5 Request trigger settings ==== 991 991 992 - Polls the trigger settings.1033 +Requests the trigger settings. 993 993 994 994 (% style="color:#037691" %)**AT Command:** 995 995 996 -There is no AT Command for this feature. 1037 +There is no AT Command available for this feature. 997 997 998 998 (% style="color:#037691" %)**Downlink Payload** 999 999 ... ... @@ -1133,9 +1133,6 @@ 1133 1133 ))) 1134 1134 |(% style="width:96px" %)**Example**|(% style="width:402px" %)09 02 **00 00 64** 1135 1135 1136 -(% class="wikigeneratedid" %) 1137 -==== ==== 1138 - 1139 1139 ==== 3.4.2.9 Trigger – Set AC (current) as a trigger ==== 1140 1140 1141 1141 Sets the current trigger based on the AC port. See also [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -1210,7 +1210,6 @@ 1210 1210 ))) 1211 1211 |(% style="width:104px" %)**Note**|(% style="width:387px" %)See also, [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1212 1212 1213 - 1214 1214 (% style="color:#037691" %)**Downlink Payload** 1215 1215 1216 1216 (% border="2" style="width:500px" %) ... ... @@ -1233,7 +1233,6 @@ 1233 1233 ))) 1234 1234 |(% style="width:104px" %)**Note**|(% style="width:394px" %)See also, [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1235 1235 1236 - 1237 1237 ==== 3.4.2.11 Trigger – Set minimum interval ==== 1238 1238 1239 1239 Sets the AV and AC trigger minimum interval. The device won't respond to a second trigger within this set time after the first trigger. ... ... @@ -1269,7 +1269,6 @@ 1269 1269 ))) 1270 1270 |(% style="width:112px" %)Note|(% style="width:386px" %)(% style="color:red" %)**The time must be greater than 5 minutes.** 1271 1271 1272 - 1273 1273 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1274 1274 1275 1275 Controls the digital outputs DO1, DO2, and DO3 ... ... @@ -1320,33 +1320,28 @@ 1320 1320 ))) 1321 1321 ))) 1322 1322 1323 -(% class="wikigeneratedid" %) 1324 -==== ==== 1325 - 1326 1326 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1327 1327 1328 1328 1329 1329 * (% style="color:#037691" %)**AT Command** 1330 1330 1331 -There is no AT Command to controlDigitalOutput1363 +There is no AT command to control the digital output. 1332 1332 1333 1333 1334 1334 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)** 1335 1335 1336 -(% style="color:blue" %)**0xA9 aa bb cc **(%%) ~/~/ Set DO1/DO2/DO3 output with time control 1368 +(% style="color:blue" %)**0xA9 aa bb cc **(%%) ~/~/ Sets DO1/DO2/DO3 outputs with time control 1337 1337 1338 - 1339 1339 This is to control the digital output time of DO pin. Include four bytes: 1340 1340 1341 -(% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9)1372 +(% style="color:#4f81bd" %)**First byte**(%%)**:** Type code (0xA9) 1342 1342 1343 -(% style="color:#4f81bd" %)**Second Byte**(%%): Inverter Mode1374 +(% style="color:#4f81bd" %)**Second byte**(%%): Inverter Mode 1344 1344 1345 -01: DO pins will change back to original state after timeout. 1376 +**01:** DO pins revert to their original state after the timeout. 1377 +**00:** DO pins switch to an inverted state after the timeout. 1346 1346 1347 -00: DO pins will change to an inverter state after timeout 1348 1348 1349 - 1350 1350 (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Port status: 1351 1351 1352 1352 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) ... ... @@ -1355,7 +1355,7 @@ 1355 1355 |0x00|DO1 set to high 1356 1356 |0x11|DO1 NO Action 1357 1357 1358 -(% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Port status:1388 +(% style="color:#4f81bd" %)**Fourth byte**(%%): Control Method and Port status: 1359 1359 1360 1360 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1361 1361 |(% style="background-color:#4f81bd; color:white" %)**Second Byte**|(% style="background-color:#4f81bd; color:white" %)**Status** ... ... @@ -1363,7 +1363,7 @@ 1363 1363 |0x00|DO2 set to high 1364 1364 |0x11|DO2 NO Action 1365 1365 1366 -(% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Port status:1396 +(% style="color:#4f81bd" %)**Fifth byte**(%%): Control Method and Port status: 1367 1367 1368 1368 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1369 1369 |(% style="background-color:#4f81bd; color:white" %)**Second Byte**|(% style="background-color:#4f81bd; color:white" %)**Status** ... ... @@ -1371,7 +1371,7 @@ 1371 1371 |0x00|DO3 set to high 1372 1372 |0x11|DO3 NO Action 1373 1373 1374 -(% style="color:#4f81bd" %)**Sixth, Seventh, Eighth, and Ninth Bytes**:(%%) Latching time (Unit: ms)1404 +(% style="color:#4f81bd" %)**Sixth, Seventh, Eighth, and Ninth bytes**:(%%) Latching time (Unit: ms) 1375 1375 1376 1376 1377 1377 (% style="color:red" %)**Note: ** ... ... @@ -1380,7 +1380,7 @@ 1380 1380 1381 1381 Before firmware v1.6.0, the latch time only supported 2 bytes. 1382 1382 1383 -(% style="color:red" %)** Device will uploada packet if the downlink code executes successfully.**1413 +(% style="color:red" %)**The device will uplink a packet if the downlink code executes successfully.** 1384 1384 1385 1385 1386 1386 **Example payload:** ... ... @@ -1407,16 +1407,16 @@ 1407 1407 1408 1408 * (% style="color:#037691" %)**AT Command:** 1409 1409 1410 -There is no AT Command to control Relay Output 1440 +There is no AT Command to control the Relay Output 1411 1411 1412 1412 1413 1413 * (% style="color:#037691" %)**Downlink Payload (prefix 0x03):** 1414 1414 1415 -(% style="color:blue" %)**0x03 aa bb ** (%%)~/~/ Set RO1/RO2 output 1445 +(% style="color:blue" %)**0x03 aa bb ** (%%)~/~/ Sets RO1/RO2 output 1416 1416 1417 1417 1418 1418 ((( 1419 -If payload is 0x030100, it means setting RO1 to close and RO2 to open. 1449 +If the payload is 0x030100, it means setting RO1 to close and RO2 to open. 1420 1420 ))) 1421 1421 1422 1422 ((( ... ... @@ -1434,7 +1434,7 @@ 1434 1434 |03 00 01|Open|Close 1435 1435 ))) 1436 1436 1437 -(% style="color:red" %)** Device will uploada packet if downlink code executes successfully.**1467 +(% style="color:red" %)**The device will uplink a packet if the downlink code executes successfully.** 1438 1438 1439 1439 1440 1440 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== ... ... @@ -1443,19 +1443,19 @@ 1443 1443 1444 1444 * (% style="color:#037691" %)**AT Command:** 1445 1445 1446 -There is no AT Command to control Relay Output 1476 +There is no AT Command to control the Relay Output 1447 1447 1448 1448 1449 1449 * (% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1450 1450 1451 -(% style="color:blue" %)**0x05 aa bb cc dd ** (%%)~/~/ Set RO1/RO2 relay with time control 1481 +(% style="color:blue" %)**0x05 aa bb cc dd ** (%%)~/~/ Sets RO1/RO2 relays with time control 1452 1452 1453 1453 1454 -This is tocontrol the relay output time.Itincludesfourbytes:1484 +This controls the relay output time and includes 4 bytes: 1455 1455 1456 -(% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05)1486 +(% style="color:#4f81bd" %)**First byte **(%%)**:** Type code (0x05) 1457 1457 1458 -(% style="color:#4f81bd" %)**Second Byte(aa)**(%%): Inverter Mode1488 +(% style="color:#4f81bd" %)**Second byte (aa)**(%%): Inverter Mode 1459 1459 1460 1460 01: Relays will change back to their original state after timeout. 1461 1461 ... ... @@ -1462,12 +1462,12 @@ 1462 1462 00: Relays will change to the inverter state after timeout. 1463 1463 1464 1464 1465 -(% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:1495 +(% style="color:#4f81bd" %)**Third byte (bb)**(%%): Control Method and Ports status: 1466 1466 1467 1467 [[image:image-20221008095908-1.png||height="364" width="564"]] 1468 1468 1469 1469 1470 -(% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms1500 +(% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh bytes (cc)**(%%): Latching time. Unit: ms 1471 1471 1472 1472 1473 1473 (% style="color:red" %)**Note:** ... ... @@ -1477,7 +1477,7 @@ 1477 1477 Before firmware v1.6.0, the latch time only supported 2 bytes. 1478 1478 1479 1479 1480 -(% style="color:red" %)** Device will uploada packet if the downlink code executes successfully.**1510 +(% style="color:red" %)**The device will uplink a packet if the downlink code executes successfully.** 1481 1481 1482 1482 1483 1483 **Example payload:** ... ... @@ -1505,131 +1505,356 @@ 1505 1505 1506 1506 When the voltage exceeds the threshold, counting begins. For details, see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1507 1507 1508 - *(% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+VOLMAX ** (%%)~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]1538 +(% style="color:#037691" %)**AT Command** 1509 1509 1510 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1540 +(% border="2" style="width:500px" %) 1541 +|(% style="width:137px" %)**Command**|(% style="width:361px" %)AT+VOLMAX=<voltage>,<logic> 1542 +|(% style="width:137px" %)**Response**|(% style="width:361px" %) 1543 +|(% style="width:137px" %)**Parameters**|(% style="width:361px" %)((( 1544 +**voltage** : voltage threshold in mV 1511 1511 1512 - (% style="color:blue" %)**0xA5 aa bbcc**(%%)~/~/ Same as AT+VOLMAX=(aa bb),cc1546 +**logic**: 1513 1513 1548 +**0** : lower than 1514 1514 1550 +**1**: higher than 1515 1515 1552 +if you leave logic parameter blank, it is considered 0 1553 +))) 1554 +|(% style="width:137px" %)**Examples**|(% style="width:361px" %)((( 1555 +AT+VOLMAX=20000 1556 + 1557 +If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1 1558 + 1559 +AT+VOLMAX=20000,0 1560 + 1561 +If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1 1562 + 1563 +AT+VOLMAX=20000,1 1564 + 1565 +If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1 1566 +))) 1567 + 1568 +(% style="color:#037691" %)**Downlink Payload** 1569 + 1570 +(% border="2" style="width:500px" %) 1571 +|(% style="width:140px" %)**Payload**|(% style="width:358px" %)<prefix><voltage><logic> 1572 +|(% style="width:140px" %)**Parameters**|(% style="width:358px" %)((( 1573 +**prefix** : A5 (hex) 1574 + 1575 +**voltage** : voltage threshold in mV (2 bytes in hex) 1576 + 1577 +**logic**: (1 byte in hexadecimal) 1578 + 1579 +**0** : lower than 1580 + 1581 +**1**: higher than 1582 + 1583 +if you leave logic parameter blank, it is considered 1 (higher than) 1584 +))) 1585 +|(% style="width:140px" %)**Example**|(% style="width:358px" %)((( 1586 +A5 **4E 20** 1587 + 1588 +If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1 1589 + 1590 +A5 **4E 20 00** 1591 + 1592 +If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1 1593 + 1594 +A5 **4E 20 01** 1595 + 1596 +If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1 1597 +))) 1598 + 1516 1516 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1517 1517 1518 -This featureallows users to pre-configure specific count numbers for various counting parameters such ascount1,count2, or AV1count. Use the AT command to set the desired count number for each configuration.1601 +This command allows users to pre-configure specific count numbers for various counting parameters such as Count1, Count2, or AVI1 Count. Use the AT command to set the desired count number for each configuration. 1519 1519 1520 - *(% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+SETCNT=aa,(bb cc dd ee) **1603 +(% style="color:#037691" %)**AT Command** 1521 1521 1522 -(% style="color:red" %)**aa:**(%%) 1: Set count1; 2: Set count2; 3: Set AV1 count 1605 +(% border="2" style="width:500px" %) 1606 +|(% style="width:134px" %)**Command**|(% style="width:364px" %)AT+SETCNT=<counting_parameter>,<number> 1607 +|(% style="width:134px" %)**Response**|(% style="width:364px" %) 1608 +|(% style="width:134px" %)**Parameters**|(% style="width:364px" %)((( 1609 +**counting_parameter** : 1523 1523 1524 - (% style="color:red"%)**bb cc dd ee: **(%%)The number to be set1611 +1: COUNT1 1525 1525 1613 +2: COUNT2 1526 1526 1527 - * (% style="color:#037691"%)**Downlink Payload (prefix 0xA8):**1615 +3: AVI1 Count 1528 1528 1529 -(% style="color:blue" %)**0x A8 aa bb cc dd ee ** (%%)~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1617 +**number** : Start number 1618 +))) 1619 +|(% style="width:134px" %)**Example**|(% style="width:364px" %)((( 1620 +AT+SETCNT=1,10 1530 1530 1622 +Sets the COUNT1 to 10. 1623 +))) 1531 1531 1625 +(% style="color:#037691" %)**Downlink Payload** 1532 1532 1627 +(% border="2" style="width:500px" %) 1628 +|(% style="width:135px" %)**Payload**|(% style="width:363px" %)<prefix><counting_parameter><number> 1629 +|(% style="width:135px" %)**Parameters**|(% style="width:363px" %)((( 1630 +prefix : A8 (hex) 1631 + 1632 +**counting_parameter** : (1 byte in hexadecimal) 1633 + 1634 +1: COUNT1 1635 + 1636 +2: COUNT2 1637 + 1638 +3: AVI1 Count 1639 + 1640 +**number** : Start number, 4 bytes in hexadecimal 1641 +))) 1642 +|(% style="width:135px" %)**Example**|(% style="width:363px" %)((( 1643 +A8 **01 00 00 00 0A** 1644 + 1645 +Sets the COUNT1 to 10. 1646 +))) 1647 + 1533 1533 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1534 1534 1535 -This featureclears the counting in counting mode.1650 +This command clears the counting in counting mode. 1536 1536 1537 - *(% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+CLRCOUNT **(%%) ~/~/ clear all counting1652 +(% style="color:#037691" %)**AT Command** 1538 1538 1539 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1654 +(% border="2" style="width:500px" %) 1655 +|(% style="width:142px" %)**Command**|(% style="width:356px" %)AT+CLRCOUNT 1656 +|(% style="width:142px" %)**Response**|(% style="width:356px" %)- 1540 1540 1541 -(% style="color: blue" %)**0x A601** (%%)~/~/ clearall counting1658 +(% style="color:#037691" %)**Downlink Payload** 1542 1542 1660 +(% border="2" style="width:500px" %) 1661 +|(% style="width:141px" %)**Payload**|(% style="width:357px" %)<prefix><clear?> 1662 +|(% style="width:141px" %)**Parameters**|(% style="width:357px" %)((( 1663 +prefix : A6 (hex) 1543 1543 1665 +clear? : 01 (hex) 1666 +))) 1667 +|(% style="width:141px" %)**Example**|(% style="width:357px" %)A6 **01** 1544 1544 1545 -==== 3.4.2.19 Counting ~-~- Changecountingmodetosavetime====1669 +==== 3.4.2.19 Counting ~-~- Set Saving Interval for 'Counting Result' ==== 1546 1546 1547 -This featureallows you to configure the device to save its counting result to internal flash memory at specified intervals. By setting a save time, the device will periodically store the counting data to prevent loss in case of power failure. The save interval can be adjusted to suit your requirements, with a minimum value of 30 seconds.1671 +This command allows you to configure the device to save its counting result to internal flash memory at specified intervals. By setting a save time, the device will periodically store the counting data to prevent loss in case of power failure. The save interval can be adjusted to suit your requirements, with a minimum value of 30 seconds. 1548 1548 1549 - *(% style="color:#037691" %)**AT Command:**1673 +(% style="color:#037691" %)**AT Command** 1550 1550 1551 -(% style="color:blue" %)**AT+COUTIME=60 **(%%)~/~/ Sets the save time to 60 seconds. The device will save the counting result in internal flash every 60 seconds. (Min value: 30 seconds) 1675 +(% border="2" style="width:500px" %) 1676 +|(% style="width:124px" %)**Command**|(% style="width:374px" %)AT+COUTIME=<time> 1677 +|(% style="width:124px" %)**Response**|(% style="width:374px" %) 1678 +|(% style="width:124px" %)**Parameters**|(% style="width:374px" %)time : seconds (0 to 16777215) 1679 +|(% style="width:124px" %)**Example**|(% style="width:374px" %)((( 1680 +AT+COUTIME=60 1552 1552 1682 +Sets the device to save its counting results to the memory every 60 seconds. 1683 +))) 1553 1553 1554 - *(% style="color:#037691" %)**Downlink Payload(prefix 0xA7):**1685 +(% style="color:#037691" %)**Downlink Payload** 1555 1555 1556 -(% style="color:blue" %)**0x A7 aa bb cc ** (%%)~/~/ same as AT+COUTIME =aa bb cc, 1687 +(% border="2" style="width:500px" %) 1688 +|(% style="width:123px" %)**Payload**|(% style="width:375px" %)<prefix><time> 1689 +|(% style="width:123px" %)**Parameters**|(% style="width:375px" %)((( 1690 +prefix : A7 1557 1557 1558 -((( 1559 -Range: aa bb cc:0 to 16777215, (unit: seconds) 1692 +time : seconds, 3 bytes in hexadecimal 1560 1560 ))) 1694 +|(% style="width:123px" %)**Example**|(% style="width:375px" %)((( 1695 +A7 **00 00 3C** 1561 1561 1697 +Sets the device to save its counting results to the memory every 60 seconds. 1698 +))) 1562 1562 1700 +==== 3.4.2.20 Reset saved RO and DO states ==== 1563 1563 1564 - ====3.4.2.20 Reset save RO DO state====1702 +This command allows you to reset the saved relay output (RO) and digital output (DO) states when the device joins the network. By configuring this setting, you can control whether the device should retain or reset the relay states after a reset and rejoin to the network. 1565 1565 1566 - This feature allows you to reset the saved relay output(RO)and digital output (DO)states when the device joins the network. Byconfiguring this setting, you can controlwhether the device should retainorresetthe relay states after a reset andrejoin to the network.1704 +(% style="color:#037691" %)**AT Command** 1567 1567 1568 -* (% style="color:#037691" %)**AT Command:** 1706 +(% border="2" style="width:500px" %) 1707 +|(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+RODORESET=<state> 1708 +|(% style="width:127px" %)**Response**|(% style="width:371px" %) 1709 +|(% style="width:127px" %)**Parameters**|(% style="width:371px" %)((( 1710 +**state** : 1569 1569 1570 - (% style="color:blue" %)**AT+RODORESET=1**(%%)~/~/RODO will close when the device joiningthe network. (default)1712 +**0** : RODO will close when the device joins the network. (default) 1571 1571 1572 -(% style="color:blue" %)**AT+RODORESET=0 **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state will not change when the device reconnects to the network. 1714 +**1**: After the device is reset, the previously saved RODO state (limited to MOD2 to MOD5) is read, and it will not change when the device reconnects to the network. 1715 +))) 1716 +|(% style="width:127px" %)**Example**|(% style="width:371px" %)((( 1717 +(% style="color:blue" %)**AT+RODORESET=1 ** 1573 1573 1719 +RODO will close when the device joins the network. (default) 1574 1574 1575 - *(% style="color:#037691" %)**Downlink Payload (prefix 0xAD):**1721 +(% style="color:blue" %)**AT+RODORESET=0 ** 1576 1576 1577 -(% style="color:blue" %)**0x AD aa ** (%%)~/~/ same as AT+RODORET =aa 1723 +After the device is reset, the previously saved RODO state (limited to MOD2 to MOD5) is read, and it will not change when the device reconnects to the network. 1724 +))) 1578 1578 1726 +(% style="color:#037691" %)**Downlink Payload** 1579 1579 1728 +(% border="2" style="width:500px" %) 1729 +|(% style="width:127px" %)**Payload**|(% style="width:371px" %)<prefix><state> 1730 +|(% style="width:127px" %)**Parameters**|(% style="width:371px" %)((( 1731 +**prefix** : AD 1580 1580 1733 +**state** : 1734 + 1735 +**0** : RODO will close when the device joins the network. (default), represents as 1 byte in hexadecimal. 1736 + 1737 +**1**: After the device is reset, the previously saved RODO state (limited to MOD2 to MOD5) is read, and it will not change when the device reconnects to the network. - represents as 1 byte in hexadecimal 1738 +))) 1739 +|(% style="width:127px" %)**Example**|(% style="width:371px" %)((( 1740 +AD **01** 1741 + 1742 +RODO will close when the device joins the network. (default) 1743 + 1744 +AD **00** 1745 + 1746 +After the device is reset, the previously saved RODO state (limited to MOD2 to MOD5) is read, and it will not change when the device reconnects to the network. 1747 +))) 1748 + 1581 1581 ==== 3.4.2.21 Encrypted payload ==== 1582 1582 1583 -This featureallows you to configure whether the device should upload data in an encrypted format or in plaintext. By default, the device encrypts the payload before uploading. You can toggle this setting to either upload encrypted data or transmit it without encryption.1751 +This command allows you to configure whether the device should upload data in an encrypted format or in plaintext. By default, the device encrypts the payload before uploading. You can toggle this setting to either upload encrypted data or transmit it without encryption. 1584 1584 1585 - *(% style="color:#037691" %)**AT Command:**1753 +(% style="color:#037691" %)**AT Command:** 1586 1586 1587 -(% style="color:blue" %)**AT+DECRYPT=1 ** (%%)~/~/ The payload is uploaded without encryption 1755 +(% border="2" style="width:500px" %) 1756 +|(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+DECRYPT=<state> 1757 +|(% style="width:127px" %)**Response**|(% style="width:371px" %) 1758 +|(% style="width:127px" %)**Parameters**|(% style="width:371px" %)((( 1759 +**state** : 1588 1588 1589 - (% style="color:blue" %)**AT+DECRYPT=0**(%%)~/~/Encrypt whenuploadingpayload(default)1761 +**1** : The payload is uploaded without encryption 1590 1590 1763 +**0** : The payload is encrypted when uploaded (default) 1764 +))) 1765 +|(% style="width:127px" %)**Example**|(% style="width:371px" %)((( 1766 +AT+DECRYPT=1 1591 1591 1768 +The payload is uploaded without encryption 1592 1592 1770 +AT+DECRYPT=0 1771 + 1772 +The payload is encrypted when uploaded (default) 1773 +))) 1774 + 1775 +There is no downlink payload for this configuration. 1776 + 1777 + 1593 1593 ==== 3.4.2.22 Get sensor value ==== 1594 1594 1780 +This command allows you to retrieve and optionally uplink sensor readings through the serial port. 1595 1595 1596 - *(% style="color:#037691" %)**AT Command:**1782 +(% style="color:#037691" %)**AT Command** 1597 1597 1598 -(% style="color:blue" %)**AT+GETSENSORVALUE=0 **(%%)~/~/ The serial port retrieves the reading of the current sensor. 1784 +(% border="2" style="width:500px" %) 1785 +|(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+GETSENSORVALUE=<state> 1786 +|(% style="width:127px" %)**Response**|(% style="width:371px" %) 1787 +|(% style="width:127px" %)**Parameters**|(% style="width:371px" %)((( 1788 +**state** : 1599 1599 1600 - (% style="color:blue" %)**AT+GETSENSORVALUE=1**(%%)~/~/ Theserial portetrieves the current sensor reading anduploadsit.1790 +**0 **: Retrieves the current sensor reading via the serial port. 1601 1601 1792 +**1 **: Retrieves and uploads the current sensor reading via the serial port. 1793 +))) 1794 +|(% style="width:127px" %)**Example**|(% style="width:371px" %)((( 1795 +AT+GETSENSORVALUE=0 1602 1602 1797 +Retrieves the current sensor reading via the serial port. 1603 1603 1604 - ==== 3.4.2.23Resets the downlink packet count====1799 +AT+GETSENSORVALUE=1 1605 1605 1801 +Retrieves and uplinks the current sensor reading via the serial port. 1802 +))) 1606 1606 1607 - *(%style="color:#037691"%)**ATCommand:**1804 +There is no downlink payload for this configuration. 1608 1608 1609 -(% style="color:blue" %)**AT+DISFCNTCHECK=0 **(%%)~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default) 1610 1610 1611 - (% style="color:blue" %)**AT+DISFCNTCHECK=1**(%%)~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384,thenode resetsthe downlinkpacketcount and keeps it consistent withtheserverdownlink packet count.1807 +==== 3.4.2.23 Resetting the downlink packet count ==== 1612 1612 1809 +This command manages how the node handles mismatched downlink packet counts. It offers two modes: one disables the reception of further downlink packets if discrepancies occur, while the other resets the downlink packet count to align with the server, ensuring continued communication. 1613 1613 1811 +(% style="color:#037691" %)**AT Command** 1614 1614 1813 +(% border="2" style="width:500px" %) 1814 +|(% style="width:130px" %)**Command**|(% style="width:368px" %)AT+DISFCNTCHECK=<state> 1815 +|(% style="width:130px" %)**Response**|(% style="width:368px" %)((( 1816 + 1817 +))) 1818 +|(% style="width:130px" %)**Parameters**|(% style="width:368px" %)((( 1819 +**state **: 1820 + 1821 +**0** : When the downlink packet count sent by the server is less than the node's downlink packet count or exceeds 16,384, the node stops receiving further downlink packets (default). 1822 + 1823 + 1824 +**1** : When the downlink packet count sent by the server is less than the node's downlink packet count or exceeds 16,384, the node resets its downlink packet count to match the server's, ensuring consistency. 1825 +))) 1826 +|(% style="width:130px" %)**Example**|(% style="width:368px" %)((( 1827 +AT+DISFCNTCHECK=0 1828 + 1829 +When the downlink packet count sent by the server is less than the node's downlink packet count or exceeds 16,384, the node stops receiving further downlink packets (default). 1830 + 1831 +AT+DISFCNTCHECK=1 1832 + 1833 +When the downlink packet count sent by the server is less than the node's downlink packet count or exceeds 16,384, the node resets its downlink packet count to match the server's, ensuring consistency. 1834 +))) 1835 + 1836 +There is no downlink payload for this configuration. 1837 + 1838 + 1615 1615 ==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ==== 1616 1616 1617 1617 1618 - *(%style="color:#037691"%)**ATCommand:**1842 +This command controls the behavior of the node when the combined size of the MAC commands (MACANS) from the server and the payload exceeds the allowed byte limit for the current data rate (DR). The command provides two modes: one enables splitting the data into batches to ensure compliance with the byte limit, while the other prioritizes the payload and ignores the MACANS in cases of overflow. 1619 1619 1620 -(% style="color: blue" %)**AT+DISMACANS=0**(%%) ~/~/ When the MACANSof the reply server plus the payload exceeds themaximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will sendapacket with a payload of 00 anda port of 4. (default)1844 +(% style="color:#037691" %)**AT Command** 1621 1621 1622 -(% style="color:blue" %)**AT+DISMACANS=1** (%%) ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part. 1846 +(% border="2" style="width:500px" %) 1847 +|(% style="width:127px" %)**Command**|(% style="width:371px" %)AT+DISMACANS=<state> 1848 +|(% style="width:127px" %)**Response**|(% style="width:371px" %) 1849 +|(% style="width:127px" %)**Parameters**|(% style="width:371px" %)((( 1850 +**state** : 1623 1623 1852 +**0** : When the combined size of the MACANS from the server and the payload exceeds the byte limit (11 bytes for DR0 of US915, DR2 of AS923, DR2 of AU915), the node sends a packet with a payload of 00 and a port of 4. (default) 1624 1624 1625 -* (% style="color:#037691" %)**Downlink Payload **(%%)**:** 1854 +**1** : When the combined size of the MACANS from the server and the payload exceeds the byte limit for the current DR, the node ignores the MACANS and only uploads the payload. 1855 +))) 1856 +|(% style="width:127px" %)**Example**|(% style="width:371px" %)((( 1857 +AT+DISMACANS=0 1626 1626 1627 - (%style="color:blue"%)**0x210001**(%%)~/~/SeteDISMACANS=11859 +When the combined size of the MACANS from the server and the payload exceeds the byte limit (11 bytes for DR0 of US915, DR2 of AS923, DR2 of AU915), the node sends a packet with a payload of 00 and a port of 4. (default) 1628 1628 1861 +AT+DISMACANS=1 1629 1629 1863 +When the combined size of the MACANS from the server and the payload exceeds the byte limit for the current DR, the node ignores the MACANS and only uploads the payload. 1864 +))) 1630 1630 1866 +(% style="color:#037691" %)**Downlink Payload** 1867 + 1868 +(% border="2" style="width:500px" %) 1869 +|(% style="width:126px" %)**Payload**|(% style="width:372px" %)<prefix><state> 1870 +|(% style="width:126px" %)**Parameters**|(% style="width:372px" %)((( 1871 +**prefix** : 21 1872 + 1873 +**state** : (2 bytes in hexadecimal) 1874 + 1875 +**0** : When the combined size of the MACANS from the server and the payload exceeds the byte limit (11 bytes for DR0 of US915, DR2 of AS923, DR2 of AU915), the node sends a packet with a payload of 00 and a port of 4. (default) 1876 + 1877 +**1 **: When the combined size of the MACANS from the server and the payload exceeds the byte limit for the current DR, the node ignores the MACANS and only uploads the payload. 1878 +))) 1879 +|(% style="width:126px" %)**Example**|(% style="width:372px" %)((( 1880 +21 **00 01** 1881 + 1882 +Set DISMACANS=1 1883 +))) 1884 + 1631 1631 ==== 3.4.2.25 Copy downlink to uplink ==== 1632 1632 1887 +This command enables the device to immediately uplink the content of a received downlink packet back to the server. The command allows for quick data replication from downlink to uplink, with a fixed port number of 100. 1633 1633 1634 1634 * (% style="color:#037691" %)**AT Command**(%%)**:** 1635 1635 ... ... @@ -1642,8 +1642,22 @@ 1642 1642 1643 1643 For example, sending 11 22 33 44 55 66 77 will return invalid configuration 00 11 22 33 44 55 66 77. 1644 1644 1900 +(% border="2" style="width:500px" %) 1901 +|(% style="width:122px" %)**Command**|(% style="width:376px" %)((( 1902 +AT+RPL=5 1645 1645 1904 +After receiving a downlink packet from the server, the node immediately uplinks the content of the packet back to the server using port number 100. 1905 +))) 1906 +|(% style="width:122px" %)**Example**|(% style="width:376px" %)((( 1907 +Downlink: 1646 1646 1909 +01 00 02 58 1910 + 1911 +Uplink: 1912 + 1913 +01 01 00 02 58 1914 +))) 1915 + 1647 1647 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173833-7.png?width=1124&height=149&rev=1.1||alt="image-20220823173833-7.png"]] 1648 1648 1649 1649 For example, if 01 00 02 58 is issued, a valid configuration of 01 01 00 02 58 will be returned. ... ... @@ -1650,14 +1650,16 @@ 1650 1650 1651 1651 1652 1652 1653 -==== 3.4.2.26 Query version number andfrequency band、TDC ====1922 +==== 3.4.2.26 Query firmware version, frequency band, sub band, and TDC time ==== 1654 1654 1924 +This command is used to query key information about the device, including its firmware version, frequency band, sub band, and TDC time. By sending the specified payload as a downlink, the server can retrieve this essential data from the device. 1655 1655 1656 1656 * ((( 1657 1657 (% style="color:#037691" %)**Downlink Payload**(%%)**:** 1658 1658 1659 -(% style="color:blue" %)**26 01 ** (%%) ~/~/ Downlink 26 01canquery deviceuploadfrequency, frequency band, softwareversion number,TDC time.1929 +(% style="color:blue" %)**26 01 ** (%%) ~/~/ The downlink payload 26 01 is used to query the device's firmware version, frequency band, sub band, and TDC time. 1660 1660 1931 + 1661 1661 1662 1662 ))) 1663 1663 ... ... @@ -1683,15 +1683,17 @@ 1683 1683 The username and password (API key) you created here are required in the next section. 1684 1684 {{/info}} 1685 1685 1686 -[[image:tts-mqtt-integration.png ||height="625" width="1000"]]1957 +[[image:tts-mqtt-integration.png]] 1687 1687 1688 1688 === 3.5.2 Configuring ThingsEye.io === 1689 1689 1961 +The ThingsEye.io IoT platform is not open for self-registration at the moment. If you are interested in testing the platform, please send your project information to admin@thingseye.io, and we will create an account for you. 1962 + 1690 1690 * Login to your [[ThingsEye.io >>https://thingseye.io]]account. 1691 1691 * Under the **Integrations center**, click **Integrations**. 1692 1692 * Click the **Add integration** button (the button with the **+** symbol). 1693 1693 1694 -[[image:thingseye-io-step-1.png ||height="625" width="1000"]]1967 +[[image:thingseye-io-step-1.png]] 1695 1695 1696 1696 1697 1697 On the **Add integration** window, configure the following: ... ... @@ -1706,7 +1706,7 @@ 1706 1706 ** Allow create devices or assets 1707 1707 * Click the **Next** button. you will be navigated to the **Uplink data converter** tab. 1708 1708 1709 -[[image:thingseye-io-step-2.png ||height="625" width="1000"]]1982 +[[image:thingseye-io-step-2.png]] 1710 1710 1711 1711 1712 1712 **Uplink data converter:** ... ... @@ -1717,7 +1717,7 @@ 1717 1717 * Paste the uplink decoder function into the text area (first, delete the default code). The demo uplink decoder function can be found [[here>>https://raw.githubusercontent.com/ThingsEye-io/te-platform/refs/heads/main/Data%20Converters/The_Things_Network_MQTT_Uplink_Converter.js]]. 1718 1718 * Click the **Next** button. You will be navigated to the **Downlink data converter **tab. 1719 1719 1720 -[[image:thingseye-io-step-3.png ||height="625" width="1000"]]1993 +[[image:thingseye-io-step-3.png]] 1721 1721 1722 1722 1723 1723 **Downlink data converter (this is an optional step):** ... ... @@ -1728,7 +1728,7 @@ 1728 1728 * Paste the downlink decoder function into the text area (first, delete the default code). The demo downlink decoder function can be found [[here>>https://raw.githubusercontent.com/ThingsEye-io/te-platform/refs/heads/main/Data%20Converters/The_Things_Network_MQTT_Downlink_Converter.js]]. 1729 1729 * Click the **Next** button. You will be navigated to the **Connection** tab. 1730 1730 1731 -[[image:thingseye-io-step-4.png ||height="625" width="1000"]]2004 +[[image:thingseye-io-step-4.png]] 1732 1732 1733 1733 1734 1734 **Connection:** ... ... @@ -1735,7 +1735,7 @@ 1735 1735 1736 1736 * Choose **Region** from the **Host type**. 1737 1737 * Enter the **cluster** of your **The Things Stack** in the **Region** textbox. You can find the cluster in the url (e.g., https:~/~/**eu1**.cloud.thethings.network/...). 1738 -* Enter the **Username** and **Password** of the MQTT integration in the **Credentials** section. The **username **and **password **can be found on the MQTT integration page of your The Things Stack account (see Configuring The Things Stack). 2011 +* Enter the **Username** and **Password** of the MQTT integration in the **Credentials** section. The **username **and **password **can be found on the MQTT integration page of your The Things Stack account (see **3.5.1 Configuring The Things Stack**). 1739 1739 * Click the **Check connection** button to test the connection. If the connection is successful, you will see the message saying **Connected**. 1740 1740 1741 1741 [[image:message-1.png]] ... ... @@ -1743,13 +1743,13 @@ 1743 1743 1744 1744 * Click the **Add** button. 1745 1745 1746 -[[image:thingseye-io-step-5.png ||height="625" width="1000"]]2019 +[[image:thingseye-io-step-5.png]] 1747 1747 1748 1748 1749 -Your integration has been added to the** Integrations** list and will be displayed on the **Integrations** page. Check whether the status is shown as **Active**. If not, review your configuration settings. 2022 +Your integration has been added to the** Integrations** list and will be displayed on the **Integrations** page. Check whether the status is shown as **Active**. If not, review your configuration settings and correct any errors. 1750 1750 1751 1751 1752 -[[image:thingseye.io_integrationsCenter_integrations.png ||height="686" width="1000"]]2025 +[[image:thingseye.io_integrationsCenter_integrations.png]] 1753 1753 1754 1754 1755 1755 ==== 3.5.2.1 Viewing integration details ==== ... ... @@ -1756,13 +1756,13 @@ 1756 1756 1757 1757 Click on your integration from the list. The **Integration details** window will appear with the **Details **tab selected. The **Details **tab shows all the settings you have provided for this integration. 1758 1758 1759 -[[image:integration-details.png ||height="686" width="1000"]]2032 +[[image:integration-details.png]] 1760 1760 1761 1761 1762 1762 If you want to edit the settings you have provided, click on the **Toggle edit mode** button. Once you have done click on the **Apply changes **button. 1763 1763 1764 1764 {{info}} 1765 -See also ThingsEye documentation. 2038 +See also [[ThingsEye documentation>>https://wiki.thingseye.io/xwiki/bin/view/Main/]]. 1766 1766 {{/info}} 1767 1767 1768 1768 ==== **3.5.2.2 Viewing events** ==== ... ... @@ -1772,12 +1772,12 @@ 1772 1772 * Select **Debug **from the **Event type** dropdown. 1773 1773 * Select the** time frame** from the **time window**. 1774 1774 1775 -[[image:thingseye-events.png ||height="686" width="1000"]]2048 +[[image:thingseye-events.png]] 1776 1776 1777 1777 1778 -* To view the JSON payload of a message, click on the three dots (...) in the Message column of the desired message. 2051 +* To view the **JSON payload** of a message, click on the **three dots (...)** in the Message column of the desired message. 1779 1779 1780 -[[image:thingseye-json.png ||width="1000"]]2053 +[[image:thingseye-json.png]] 1781 1781 1782 1782 1783 1783 ==== **3.5.2.3 Deleting an integration** ==== ... ... @@ -1785,12 +1785,17 @@ 1785 1785 If you want to delete an integration, click the **Delete integratio**n button on the Integrations page. 1786 1786 1787 1787 2061 +==== 3.5.2.4 Creating a Dashboard to Display and Analyze LT-22222-L Data ==== 2062 + 2063 +This will be added soon. 2064 + 2065 + 1788 1788 == 3.6 Interface Details == 1789 1789 1790 1790 === 3.6.1 Digital Input Ports: DI1/DI2/DI3 (For LT-33222-L, Low Active) === 1791 1791 1792 1792 1793 -Supports 2071 +Supports** NPN-type **sensors. 1794 1794 1795 1795 [[image:1653356991268-289.png]] 1796 1796 ... ... @@ -1912,15 +1912,15 @@ 1912 1912 ))) 1913 1913 1914 1914 1915 -(% style="color:blue" %)**Example4**(%%): Connecting to Dry Contact sensor 2193 +(% style="color:blue" %)**Example 4**(%%): Connecting to a Dry Contact sensor 1916 1916 1917 -From the DI port circuit above, you can see that activating the photocoupler requires a voltage difference between the DI+ and DI- ports. However, the Dry Contact sensor is a passive component and cannot provide this voltage difference.2195 +From the DI port circuit above, activating the photocoupler requires a voltage difference between the DI+ and DI- ports. However, the Dry Contact sensor is a passive component and cannot provide this voltage difference on its own. 1918 1918 1919 -To detect a Dry Contact, you can supply a power source to one pin of the Dry Contact. Belowis areference circuit diagram.2197 +To detect a Dry Contact, you can supply a power source to one of the pins of the Dry Contact. A reference circuit diagram is shown below. 1920 1920 1921 1921 [[image:image-20230616235145-1.png]] 1922 1922 1923 -(% style="color:blue" %)**Example5**(%%): Connecting to an Open Collector 2201 +(% style="color:blue" %)**Example 5**(%%): Connecting to an Open Collector 1924 1924 1925 1925 [[image:image-20240219115718-1.png]] 1926 1926 ... ... @@ -1996,7 +1996,7 @@ 1996 1996 [[image:image-20220524100215-10.png||height="382" width="723"]] 1997 1997 1998 1998 1999 -== 3.7 LED sIndicators ==2277 +== 3.7 LED Indicators == 2000 2000 2001 2001 The table below lists the behavior of LED indicators for each port function. 2002 2002 ... ... @@ -2035,13 +2035,14 @@ 2035 2035 == 4.1 Connecting the LT-22222-L to a PC == 2036 2036 2037 2037 ((( 2038 -You can use a USB-to-TTL adapter along with a 3.5mm Program Cable to connect the LT-22222-L to a PC, as shown below. 2316 +You can use a USB-to-TTL adapter/converter along with a 3.5mm Program Cable to connect the LT-22222-L to a PC, as shown below. 2039 2039 2040 -[[image:usb-ttl-programming.png]] 2318 +[[image:usb-ttl-audio-jack-connection.jpg]] 2319 + 2320 + 2041 2041 ))) 2042 2042 2043 2043 2044 - 2045 2045 ((( 2046 2046 On the PC, you need to set the (% style="color:#4f81bd" %)**serial tool **(%%)(such as [[PuTTY>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]] or [[SecureCRT>>https://www.vandyke.com/cgi-bin/releases.php?product=securecrt]]) to a baud rate of (% style="color:green" %)**9600**(%%) to access the serial console of LT-22222-L. Access to AT commands is disabled by default, and a password (default: (% style="color:green" %)**123456**)(%%) must be entered to enable AT command access, as shown below: 2047 2047 ))) ... ... @@ -2071,39 +2071,39 @@ 2071 2071 * **##AT+APPSKEY##**: Get or set the Application Session Key (AppSKey) 2072 2072 * **##AT+APPEUI##**: Get or set the Application EUI (AppEUI) 2073 2073 * **##AT+ADR##**: Get or set the Adaptive Data Rate setting. (0: OFF, 1: ON) 2074 -* AT+TXP: Get or set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Specification) 2075 -* AT+DR: Get or set the Data Rate. (0-7 corresponding to DR_X) 2076 -* AT+DCS: Get or set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 2077 -* AT+PNM: Get or set the public network mode. (0: off, 1: on) 2078 -* AT+RX2FQ: Get or set the Rx2 window frequency 2079 -* AT+RX2DR: Get or set the Rx2 window data rate (0-7 corresponding to DR_X) 2080 -* AT+RX1DL: Get or set the delay between the end of the Tx and the Rx Window 1 in ms 2081 -* AT+RX2DL: Get or set the delay between the end of the Tx and the Rx Window 2 in ms 2082 -* AT+JN1DL: Get or set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms 2083 -* AT+JN2DL: Get or set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms 2084 -* AT+NJM: Get or set the Network Join Mode. (0: ABP, 1: OTAA) 2085 -* AT+NWKID: Get or set the Network ID 2086 -* AT+FCU: Get or set the Frame Counter Uplink (FCntUp) 2087 -* AT+FCD: Get or set the Frame Counter Downlink (FCntDown) 2088 -* AT+CLASS: Get or set the Device Class 2089 -* AT+JOIN: Join network 2090 -* AT+NJS: Get OTAA Join Status 2091 -* AT+SENDB: Send hexadecimal data along with the application port 2092 -* AT+SEND: Send text data along with the application port 2093 -* AT+RECVB: Print last received data in binary format (with hexadecimal values) 2094 -* AT+RECV: Print last received data in raw format 2095 -* AT+VER: Get current image version and Frequency Band 2096 -* AT+CFM: Get or Set the confirmation mode (0-1) 2097 -* AT+CFS: Get confirmation status of the last AT+SEND (0-1) 2098 -* AT+SNR: Get the SNR of the last received packet 2099 -* AT+RSSI: Get the RSSI of the last received packet 2100 -* AT+TDC: Get or set the application data transmission interval in ms 2101 -* AT+PORT: Get or set the application port 2102 -* AT+DISAT: Disable AT commands 2103 -* AT+PWORD: Set password, max 9 digits 2104 -* AT+CHS: Get or set the Frequency (Unit: Hz) for Single Channel Mode 2105 -* AT+CHE: Get or set eight channels mode, Only for US915, AU915, CN470 2106 -* AT+CFG: Print all settings 2353 +* ##**AT+TXP**##: Get or set the Transmit Power (0-5, MAX:0, MIN:5, according to LoRaWAN Specification) 2354 +* **##AT+DR##**: Get or set the Data Rate. (0-7 corresponding to DR_X) 2355 +* **##AT+DCS##**: Get or set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing 2356 +* ##**AT+PNM**##: Get or set the public network mode. (0: off, 1: on) 2357 +* ##**AT+RX2FQ**##: Get or set the Rx2 window frequency 2358 +* ##**AT+RX2DR**##: Get or set the Rx2 window data rate (0-7 corresponding to DR_X) 2359 +* ##**AT+RX1DL**##: Get or set the delay between the end of the Tx and the Rx Window 1 in ms 2360 +* ##**AT+RX2DL**##: Get or set the delay between the end of the Tx and the Rx Window 2 in ms 2361 +* ##**AT+JN1DL**##: Get or set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms 2362 +* ##**AT+JN2DL**##: Get or set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms 2363 +* ##**AT+NJM**##: Get or set the Network Join Mode. (0: ABP, 1: OTAA) 2364 +* ##**AT+NWKID**##: Get or set the Network ID 2365 +* ##**AT+FCU**##: Get or set the Frame Counter Uplink (FCntUp) 2366 +* ##**AT+FCD**##: Get or set the Frame Counter Downlink (FCntDown) 2367 +* ##**AT+CLASS**##: Get or set the Device Class 2368 +* ##**AT+JOIN**##: Join network 2369 +* ##**AT+NJS**##: Get OTAA Join Status 2370 +* ##**AT+SENDB**##: Send hexadecimal data along with the application port 2371 +* ##**AT+SEND**##: Send text data along with the application port 2372 +* ##**AT+RECVB**##: Print last received data in binary format (with hexadecimal values) 2373 +* ##**AT+RECV**##: Print last received data in raw format 2374 +* ##**AT+VER**##: Get current image version and Frequency Band 2375 +* ##**AT+CFM**##: Get or Set the confirmation mode (0-1) 2376 +* ##**AT+CFS**##: Get confirmation status of the last AT+SEND (0-1) 2377 +* ##**AT+SNR**##: Get the SNR of the last received packet 2378 +* ##**AT+RSSI**##: Get the RSSI of the last received packet 2379 +* ##**AT+TDC**##: Get or set the application data transmission interval in ms 2380 +* ##**AT+PORT**##: Get or set the application port 2381 +* ##**AT+DISAT**##: Disable AT commands 2382 +* ##**AT+PWORD**##: Set password, max 9 digits 2383 +* ##**AT+CHS**##: Get or set the Frequency (Unit: Hz) for Single Channel Mode 2384 +* ##**AT+CHE**##: Get or set eight channels mode, Only for US915, AU915, CN470 2385 +* ##**AT+CFG**##: Print all settings 2107 2107 ))) 2108 2108 2109 2109 ... ... @@ -2268,7 +2268,7 @@ 2268 2268 You will need the following things before proceeding: 2269 2269 2270 2270 * 3.5mm programming cable (included with the LT-22222-L as an additional accessory) 2271 -* USB to TTL adapter 2550 +* USB to TTL adapter/converter 2272 2272 * Download and install the [[STM32 Flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. (replaced by STM32CubeProgrammer) 2273 2273 * Download the latest firmware image from [[LT-22222-L firmware image files>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AACrbrDN0AqLHbBat0ViWx5Da/LT-22222-L/Firmware?dl=0&subfolder_nav_tracking=1]]. Check the file name of the firmware to find the correct region. 2274 2274 ... ... @@ -2278,7 +2278,7 @@ 2278 2278 2279 2279 Below is the hardware setup for uploading a firmware image to the LT-22222-L: 2280 2280 2281 -[[image:usb-ttl- programming.png]]2560 +[[image:usb-ttl-audio-jack-connection.jpg]] 2282 2282 2283 2283 2284 2284
- Screenshot 2024-11-23 at 18.27.11.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.pradeeka - Size
-
... ... @@ -1,0 +1,1 @@ 1 +143.4 KB - Content
- dragino-lorawan-nw-lt-22222-n.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.pradeeka - Size
-
... ... @@ -1,0 +1,1 @@ 1 +267.3 KB - Content
- dragino-ttn-te.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.pradeeka - Size
-
... ... @@ -1,0 +1,1 @@ 1 +273.8 KB - Content
- lorawan-nw.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.pradeeka - Size
-
... ... @@ -1,0 +1,1 @@ 1 +250.6 KB - Content
- lt-22222-l-joining.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.pradeeka - Size
-
... ... @@ -1,0 +1,1 @@ 1 +301.9 KB - Content
- lt33222-l.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.pradeeka - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.3 KB - Content
- usb-ttl-audio-jack-connection.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.pradeeka - Size
-
... ... @@ -1,0 +1,1 @@ 1 +394.4 KB - Content