... ... @@ -1,34 +1,45 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 +**LT-22222-L LoRa IO Controller User Manual ** 4 4 5 -1. Introduction 6 -11. What is LT Series I/O Controller 7 7 8 8 9 -The Dragino LT series I/O Modules are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as: analog current Input, analog voltage input, relay output, digital input and digital output etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 10 10 9 += 1.Introduction = 11 11 12 - TheLTI/O Controllers allows the user to send dataand reach extremely long ranges. It providesultra-longrangespread spectrum communication and high interference immunity whilstminimizingcurrent consumption. It targets professionalwireless sensornetwork applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on.11 +== 1.1 What is LT Series I/O Controller == 13 13 13 +((( 14 +The Dragino LT series I/O Modules are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as: analog current Input, analog voltage input, relay output, digital input and digital output etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 15 +))) 14 14 17 +((( 18 +The LT I/O Controllers allows the user to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on. 19 +))) 20 + 21 +((( 15 15 The LT I/O Controllers is aiming to provide a simple plug and play, low cost installation by using LoRaWAN wireless technology. 23 +))) 16 16 25 +((( 17 17 The use environment includes: 27 +))) 18 18 29 +((( 19 19 1) If user’s area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless. 31 +))) 20 20 33 +((( 21 21 2) User can set up a LoRaWAN gateway locally and configure the controller to connect to the gateway via wireless. 35 +))) 22 22 37 +((( 38 +[[image:1653295757274-912.png]] 39 +))) 23 23 24 - [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]]41 +== 1.2 Specifications == 25 25 26 - 27 - 28 - 29 -1. 30 -11. Specifications 31 - 32 32 **Hardware System:** 33 33 34 34 * STM32L072CZT6 MCU ... ... @@ -35,21 +35,8 @@ 35 35 * SX1276/78 Wireless Chip 36 36 * Power Consumption: 37 37 ** Idle: 4mA@12v 38 - 39 -* 40 40 ** 20dB Transmit: 34mA@12v 41 41 42 - 43 -**Interface for Model: LT33222-L:** 44 - 45 -* 3 x Digital Input ( Detect Low signal , Max, 6V) 46 -* 3 x Digital Output (NPN output. Max pull up voltage 36V,450mA) 47 -* 2 x Relay Output (5A@250VAC / 30VDC) 48 -* 2 x 0~~20mA Analog Input (res:0.01mA) 49 -* 2 x 0~~30V Analog Input (res:0.01v) 50 -* Power Input 7~~ 24V DC. 51 -* 52 - 53 53 **Interface for Model: LT22222-L:** 54 54 55 55 * 2 x Digital dual direction Input (Detect High/Low signal, Max: 50v, or 220v with optional external resistor) ... ... @@ -59,7 +59,6 @@ 59 59 * 2 x 0~~30V Analog Input (res:0.01v) 60 60 * Power Input 7~~ 24V DC. 61 61 62 - 63 63 **LoRa Spec:** 64 64 65 65 * Frequency Range: ... ... @@ -81,9 +81,8 @@ 81 81 * Automatic RF Sense and CAD with ultra-fast AFC. 82 82 * Packet engine up to 256 bytes with CRC. 83 83 81 +== 1.3 Features == 84 84 85 -* 86 -*1. Features 87 87 * LoRaWAN Class A & Class C protocol 88 88 * Optional Customized LoRa Protocol 89 89 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865 ... ... @@ -92,10 +92,8 @@ 92 92 * Firmware upgradable via program port 93 93 * Counting 94 94 91 +== 1.4 Applications == 95 95 96 - 97 -* 98 -*1. Applications 99 99 * Smart Buildings & Home Automation 100 100 * Logistics and Supply Chain Management 101 101 * Smart Metering ... ... @@ -103,26 +103,11 @@ 103 103 * Smart Cities 104 104 * Smart Factory 105 105 100 +== 1.5 Hardware Variants == 106 106 107 - 108 - 109 -1. 110 -11. Hardware Variants 111 - 112 - 113 -|**Model**|**Photo**|**Description** 114 -|**LT33222-L**|[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image002.jpg]]|((( 115 -* 3 x Digital Input 116 -* 3 x Digital Output 117 -* 2 x Relay Output (5A@250VAC / 30VDC) 118 -* 2 x 0~~20mA Analog Input (res:0.01mA) 119 -* 2 x 0~~30V Analog Input (res:0.01v) 120 -* 1 x Counting Port 121 -))) 122 - 123 - 124 -|**Model**|**Photo**|**Description** 125 -|**LT22222-L**|[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image003.jpg]]|((( 102 +(% border="1" style="background-color:#f7faff; width:540px" %) 103 +|(% style="width:103px" %)**Model**|(% style="width:131px" %)**Photo**|(% style="width:334px" %)**Description** 104 +|(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)[[image:1653296302983-697.png]]|(% style="width:334px" %)((( 126 126 * 2 x Digital Input (Bi-direction) 127 127 * 2 x Digital Output 128 128 * 2 x Relay Output (5A@250VAC / 30VDC) ... ... @@ -131,25 +131,8 @@ 131 131 * 1 x Counting Port 132 132 ))) 133 133 113 +2. 134 134 135 - 136 -1. 137 -11. Firmware Change log 138 - 139 -[[**LT Image files**>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]**:** 140 - 141 -http:~/~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/ 142 - 143 - 144 -**Change log:** 145 - 146 -[[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/&file=changelog>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/&file=changelog]] 147 - 148 - 149 - 150 -1. Power ON Device 151 - 152 - 153 153 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. 154 154 155 155 PWR will on when device is properly powered.
- 1653295757274-912.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +85.8 KB - Content
- 1653296302983-697.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +42.6 KB - Content
- 1653297104069-180.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +392.6 KB - Content
- 1653297924498-393.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +202.7 KB - Content
- image-20220523172350-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +71.3 KB - Content