Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -23,10 +23,6 @@ 23 23 24 24 ((( 25 25 ((( 26 -{{info}} 27 -**This manual is also applicable to the LT-33222-L.** 28 -{{/info}} 29 - 30 30 The Dragino (% style="color:blue" %)**LT-22222-L I/O Controller**(%%) is an advanced LoRaWAN device designed to provide seamless wireless long-range connectivity with various I/O options, including analog current and voltage inputs, digital inputs and outputs, and relay outputs. 31 31 32 32 The LT-22222-L I/O Controller simplifies and enhances I/O monitoring and controlling. It is ideal for professional applications in wireless sensor networks, including irrigation systems, smart metering, smart cities, building automation, and more. These controllers are designed for easy, cost-effective deployment using LoRa wireless technology. ... ... @@ -115,9 +115,8 @@ 115 115 * Smart cities 116 116 * Smart factory 117 117 114 += 2. Assembling the device = 118 118 119 -== 2. Assembling the device == 120 - 121 121 == 2.1 Connecting the antenna == 122 122 123 123 Connect the LoRa antenna to the antenna connector, **ANT**,** **located on the top right side of the device, next to the upper screw terminal block. Secure the antenna by tightening it clockwise. ... ... @@ -282,10 +282,10 @@ 282 282 [[image:lt-22222-ul-payload-fmt.png||height="686" width="1000"]] 283 283 284 284 285 -== 3.3 Work ingModes and Uplink Payload formats ==280 +== 3.3 Work Modes and Uplink Payload formats == 286 286 287 287 288 -The LT-22222-L has 5 **work ingmodes**. It also has an interrupt/trigger mode for different types of applications that can be used together with any workingmode as an additional feature. The default mode is MOD1 and you can switch between these modes using AT commands.283 +The LT-22222-L has 5 **work modes**. It also has an interrupt/trigger mode for different types of applications that can be used together with any work mode as an additional feature. The default mode is MOD1 and you can switch between these modes using AT commands. 289 289 290 290 * (% style="color:blue" %)**MOD1**(%%): (default mode/factory set): 2ACI + 2AVI + DI + DO + RO 291 291 ... ... @@ -299,7 +299,7 @@ 299 299 300 300 * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 301 301 302 -The uplink messages are sent over LoRaWAN FPort =2. By default, an uplink message is sent every 10 minutes.297 +The uplink messages are sent over LoRaWAN FPort 2. By default, an uplink message is sent every 10 minutes. 303 303 304 304 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 305 305 ... ... @@ -308,7 +308,7 @@ 308 308 309 309 The uplink payload is 11 bytes long. 310 310 311 -(% style="color:red" %)**Note:The maximum count depends on the bytes number of bytes.306 +(% style="color:red" %)**Note:The maximum count depends on the bytes it is. 312 312 The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec). 313 313 It starts counting again when it reaches the maximum value.**(% style="display:none" wfd-invisible="true" %) 314 314 ... ... @@ -368,13 +368,9 @@ 368 368 * [1] DO2 channel output is LOW, and the DO2 LED is ON. 369 369 * [0] DO1 channel output state: 370 370 ** DO1 is FLOATING when there is no load between DO1 and V+. 371 -** DO1 is HIGH andthere is a load between DO1 and V+.366 +** DO1 is HIGH when there is a load between DO1 and V+. 372 372 ** DO1 LED is OFF in both cases. 373 373 374 -Reserve = 0 375 - 376 -MOD = 1 377 - 378 378 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 379 379 380 380 ... ... @@ -630,27 +630,24 @@ 630 630 ))) 631 631 632 632 633 -=== 3.3.6 AT+ADDMOD~=6 (Trigger Mode, Optional) === 624 +=== 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 634 634 635 635 636 -(% style="color:#4f81bd" %)**This mode is optional and intended for trigger purposes. It can operate __alongside__with other modes.**627 +(% style="color:#4f81bd" %)**This mode is optional and intended for trigger purposes. It can operate together with other modes.** 637 637 638 -For example, if you configure the following commands: 629 +For example, if you configured the following commands: 639 639 640 -* **AT+MOD=1 ** **~-~->** Sets the default workingmode641 -* **AT+ADDMOD6=1** **~-~->** Enable strigger mode631 +* **AT+MOD=1 ** **~-~->** The default work mode 632 +* **AT+ADDMOD6=1** **~-~->** Enable trigger mode 642 642 643 -The LT-22222-L will continuously monitor AV1, AV2, AC1, and AC2 every 5 seconds. Itwill send uplink packets in two cases:634 +The LT-22222-L will continuously monitor AV1, AV2, AC1, and AC2 every 5 seconds. LT will send uplink packets in two cases: 644 644 645 -1. Periodic uplink :Based on TDC time.setabove). These are (% style="color:#4f81bd" %)**unconfirmed**(%%) uplinks.636 +1. Periodically uplink (Based on TDC time). The payload is the same as in normal mode (MOD=1 for the commands above). These are (% style="color:#4f81bd" %)**unconfirmed**(%%) uplinks. 646 646 1. ((( 647 -Trigger uplink: sent when a trigger condition is met. In this case, LT will send two packets 648 - 649 -* The first uplink uses the payload specified in trigger mode (MOD=6). 650 -* The second packet uses the normal mode payload (MOD=1 as set above). Both are (% style="color:#4f81bd" %)**confirmed uplinks.** 638 +Trigger uplink when the trigger condition is met. LT will send two packets in this case. The first uplink uses the payload specified in trigger mode (MOD=6). The second packet uses the normal mode payload (MOD=1 as set above). Both are (% style="color:#4f81bd" %)**confirmed uplinks.** 651 651 ))) 652 652 653 -(% style="color:#037691" %)**AT Commands to set Trigger Condition s**:641 +(% style="color:#037691" %)**AT Commands to set Trigger Condition**: 654 654 655 655 (% style="color:#4f81bd" %)**Trigger based on voltage**: 656 656 ... ... @@ -659,9 +659,9 @@ 659 659 660 660 **Example:** 661 661 662 -AT+AVLIM=3000,6000,0,2000 (triggers an uplink if AVI1 voltage is lower than 3V or higher than 6V, or if AV2 voltage is higher than 2V) 650 +AT+AVLIM=3000,6000,0,2000 (triggers an uplink if AVI1 voltage is lower than 3V or higher than 6V, or if AV2 voltage is higher than 2V) 663 663 664 -AT+AVLIM=5000,0,0,0 (triggers an uplink if AVI1 voltage lower than 5V. Use 0 for parameters that are not in use) 652 +AT+AVLIM=5000,0,0,0 (triggers an uplink if AVI1 voltage lower than 5V. Use 0 for parameters that are not in use) 665 665 666 666 667 667 (% style="color:#4f81bd" %)**Trigger based on current**: ... ... @@ -671,7 +671,7 @@ 671 671 672 672 **Example:** 673 673 674 -AT+ACLIM=10000,15000,0,0 (triggers an uplink if AC1 current is lower than 10mA or higher than 15mA)662 +AT+ACLIM=10000,15000,0,0 (triggers an uplink if ACI1 voltage is lower than 10mA or higher than 15mA) 675 675 676 676 677 677 (% style="color:#4f81bd" %)**Trigger based on DI status**: ... ... @@ -848,7 +848,6 @@ 848 848 849 849 These commands are specially designed for the LT-22222-L. Commands can be sent to the device using options such as an AT command or a LoRaWAN downlink payload. 850 850 851 - 852 852 ==== 3.4.2.1 Set Transmit Interval ==== 853 853 854 854 Sets the uplink interval of the device. The default uplink transmission interval is 10 minutes. ... ... @@ -858,7 +858,7 @@ 858 858 (% style="width:500px" %) 859 859 |**Command**|AT+TDC<time> 860 860 |**Response**| 861 -|**Parameters**|time :uplink interval is in milliseconds848 +|**Parameters**|<time> uplink interval is in milliseconds 862 862 |**Example**|((( 863 863 AT+TDC=30000 864 864 ... ... @@ -872,9 +872,9 @@ 872 872 <prefix><time> 873 873 ))) 874 874 |**Parameters**|((( 875 -prefix :0x01862 +<prefix> 0x01 876 876 877 -time :uplink interval is in milliseconds, represented by 3 bytes in hexadecimal.864 +<time> uplink interval is in milliseconds, represented by 3 bytes in hexadecimal. 878 878 ))) 879 879 |**Example**|((( 880 880 01 **00 75 30** ... ... @@ -886,181 +886,85 @@ 886 886 See [[RapidTables>>https://www.rapidtables.com/convert/number/decimal-to-hex.html?x=30000]] 887 887 ))) 888 888 889 -==== 3.4.2.2 Set the Work ingMode (AT+MOD) ====876 +==== 3.4.2.2 Set the Work Mode (AT+MOD) ==== 890 890 891 -Sets the working mode. 892 892 893 - (%style="color:#037691"%)**AT command**879 +Sets the work mode. 894 894 895 -(% style="width:500px" %) 896 -|(% style="width:97px" %)**Command**|(% style="width:413px" %)AT+MODE<working_mode> 897 -|(% style="width:97px" %)**Response**|(% style="width:413px" %) 898 -|(% style="width:97px" %)**Parameters**|(% style="width:413px" %)((( 899 -working_mode : 881 +* (% style="color:#037691" %)**AT command:**(%%) (% style="color:blue" %)**AT+MOD=N ** 900 900 901 - 1 = (Default mode/factory set): 2ACI+2AVI+DI+ DO + RO883 +Where N is the work mode. 902 902 903 - 2= Double DICounting+DO + RO885 +**Example**: AT+MOD=2. This will set the work mode to Double DI counting mode. 904 904 905 -3 = Single DI Counting + 2 x ACI + DO + RO 906 906 907 - 4= Single DI Counting+ 1 x VoltageCounting+ DO + RO888 +* (% style="color:#037691" %)**Downlink payload (prefix 0x0A):** 908 908 909 - 5= SingleDI Counting+ 2xVI+1xACI+DO+RO890 +(% style="color:blue" %)**0x0A aa **(%%)** ** ~/~/ Same as AT+MOD=aa 910 910 911 -6 = Trigger Mode, Optional, used together with MOD1 ~~ MOD5 912 -))) 913 -|(% style="width:97px" %)**Example**|(% style="width:413px" %)((( 914 -AT+MOD=2 915 915 916 -Sets the device to working mode 2 (Double DI Counting + DO + RO) 917 -))) 918 918 919 -(% class="wikigeneratedid" %) 920 -(% style="color:#037691" %)**Downlink payload** 894 +==== 3.4.2.3 Poll an uplink ==== 921 921 922 -(% style="width:500px" %) 923 -|(% style="width:98px" %)**Payload**|(% style="width:400px" %)<prefix><working_mode> 924 -|(% style="width:98px" %)**Parameters**|(% style="width:400px" %)((( 925 -prefix : 0x0A 896 +Requests the device to send an uplink. 926 926 927 -working_mode : Working mode, represented by 1 byte in hexadecimal. 928 -))) 929 -|(% style="width:98px" %)**Example**|(% style="width:400px" %)((( 930 -0A **02** 931 931 932 -Sets the device to working mode 2 (Double DI Counting + DO + RO) 933 -))) 899 +* (% style="color:#037691" %)**AT command:**(%%) There is no AT Command to poll uplink 934 934 935 - ====3.4.2.3Pollanuplink====901 +* (% style="color:#037691" %)**Downlink payload (prefix 0x08):** 936 936 937 - Requestsan uplinkfrom LT-22222-L.903 +(% style="color:blue" %)**0x08 FF **(%%)** **~/~/ Poll an uplink 938 938 939 - (% style="color:#037691"%)**ATcommand**905 +**Example**: 0x08FF, ask device to send an Uplink 940 940 941 -There is no AT Command to request an uplink from LT-22222-L 942 942 943 -(% style="color:#037691" %)**Downlink payload** 944 944 945 -(% style="width:500px" %) 946 -|(% style="width:101px" %)**Payload**|(% style="width:397px" %)<prefix>FF 947 -|(% style="width:101px" %)**Parameters**|(% style="width:397px" %)prefix : 0x08 948 -|(% style="width:101px" %)**Example**|(% style="width:397px" %)((( 949 -08 FF 950 - 951 -Requests an uplink from LT-22222-L. 952 -))) 953 - 954 954 ==== 3.4.2.4 Enable/Disable Trigger Mode ==== 955 955 956 -Enable or disable the trigger mode for the current working mode(see also [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]).911 +Enable or disable the trigger mode (see also [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]). 957 957 958 -(% style="color:#037691" %)**AT Command** 913 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+ADDMOD6=1 or 0** 959 959 960 -(% style="width:500px" %) 961 -|(% style="width:95px" %)**Command**|(% style="width:403px" %)AT+ADDMOD6=<enable/disable trigger_mode> 962 -|(% style="width:95px" %)**Response**|(% style="width:403px" %) 963 -|(% style="width:95px" %)**Parameters**|(% style="width:403px" %)((( 964 -enable/disable trigger_mode : 915 +(% style="color:red" %)**1:** (%%)Enable the trigger mode 965 965 966 - 1=nable trigger mode917 +(% style="color:red" %)**0: **(%%)Disable the trigger mode 967 967 968 -0 = disable trigger mode 969 -))) 970 -|(% style="width:95px" %)**Example**|(% style="width:403px" %)((( 971 -AT+ADDMOD6=1 972 972 973 -Enable trigger mode for the current working mode 974 -))) 920 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):** 975 975 976 -(% style="color: #037691" %)**Downlinkpayload**922 +(% style="color:blue" %)**0x0A 06 aa **(%%) ~/~/ Same as AT+ADDMOD6=aa 977 977 978 -(% style="width:500px" %) 979 -|(% style="width:97px" %)**Payload**|(% style="width:401px" %)<prefix><enable/disable trigger_mode> 980 -|(% style="width:97px" %)**Parameters**|(% style="width:401px" %)((( 981 -prefix : 0x0A 06 982 982 983 -working mode : enable (1) or disable (0), represented by 1 byte in hexadecimal. 984 -))) 985 -|(% style="width:97px" %)**Example**|(% style="width:401px" %)((( 986 -0A 06 **01** 987 987 988 -Enable trigger mode for the current working mode 989 -))) 990 - 991 991 ==== 3.4.2.5 Poll trigger settings ==== 992 992 993 993 Polls the trigger settings. 994 994 995 -(% style="color:#037691" %)**AT Command:** 930 +* (% style="color:#037691" %)**AT Command:** 996 996 997 997 There is no AT Command for this feature. 998 998 999 -(% style="color:#037691" %)**Downlink Payload** 934 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 1000 1000 1001 -(% style="width:500px" %) 1002 -|(% style="width:95px" %)**Payload**|(% style="width:403px" %)<prefix> 1003 -|(% style="width:95px" %)**Parameters**|(% style="width:403px" %)prefix : AB 06 1004 -|(% style="width:95px" %)**Example**|(% style="width:403px" %)((( 1005 -AB 06 936 +(% style="color:blue" %)**0xAB 06 ** (%%) ~/~/ Poll the trigger settings. Device will uplink trigger settings once receive this command 1006 1006 1007 -Uplinks the trigger settings. 1008 -))) 1009 1009 1010 -==== 3.4.2.6 Enable/Disable DI1/DI2 as a trigger ==== 1011 1011 1012 -Enable ordisable DI1/DI2 as a trigger.940 +==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as a trigger ==== 1013 1013 1014 - (% style="color:#037691"%)**ATCommand**942 +Enable or disable DI1/DI2/DI2 as a trigger. 1015 1015 1016 -(% style="width:500px" %) 1017 -|(% style="width:98px" %)Command|(% style="width:400px" %)AT+DTRI=<DI1_trigger><DI2_trigger> 1018 -|(% style="width:98px" %)Response|(% style="width:400px" %) 1019 -|(% style="width:98px" %)Parameters|(% style="width:400px" %)((( 1020 -DI1_trigger: 944 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 1021 1021 1022 - 1=enable DI1 trigger946 +**Example:** AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 1023 1023 1024 -0 = disable DI1 trigger 1025 1025 1026 - DI2_trigger949 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 1027 1027 1028 - 1=enableDI2trigger951 +(% style="color:blue" %)**0xAA 02 aa bb ** (%%) ~/~/ Same as AT+DTRI=aa,bb 1029 1029 1030 -0 = disable DI2 trigger 1031 -))) 1032 -|(% style="width:98px" %)Example|(% style="width:400px" %)((( 1033 -AT+DTRI=1,0 1034 1034 1035 -Enable DI1 trigger, disable DI2 trigger 1036 -))) 1037 1037 1038 -(% class="wikigeneratedid" %) 1039 -(% style="color:#037691" %)**Downlink Payload** 1040 - 1041 -(% style="width:500px" %) 1042 -|(% style="width:101px" %)Payload|(% style="width:397px" %)<prefix><DI1_trigger><DI2_trigger> 1043 -|(% style="width:101px" %)Parameters|(% style="width:397px" %)((( 1044 -prefix : AA 02 1045 - 1046 -DI1_trigger: 1047 - 1048 -1 = enable DI1 trigger, represented by 1 byte in hexadecimal. 1049 - 1050 -0 = disable DI1 trigger, represented by 1 byte in hexadecimal. 1051 - 1052 -DI2 _trigger 1053 - 1054 -1 = enable DI2 trigger, represented by 1 byte in hexadecimal. 1055 - 1056 -0 = disable DI2 trigger, represented by 1 byte in hexadecimal. 1057 -))) 1058 -|(% style="width:101px" %)Example|(% style="width:397px" %)((( 1059 -AA 02 **01 00** 1060 - 1061 -Enable DI1 trigger, disable DI2 trigger 1062 -))) 1063 - 1064 1064 ==== 3.4.2.7 Trigger1 – Set DI or DI3 as a trigger ==== 1065 1065 1066 1066 Sets DI1 or DI3 (for LT-33222-L) as a trigger. ... ... @@ -1079,12 +1079,6 @@ 1079 1079 (% style="color:blue" %)**0x09 01 aa bb cc ** (%%) ~/~/ same as AT+TRIG1=aa,0x(bb cc) 1080 1080 1081 1081 1082 -(% style="width:500px" %) 1083 -|(% style="width:101px" %)Command|(% style="width:397px" %) 1084 -|(% style="width:101px" %)Response|(% style="width:397px" %) 1085 -|(% style="width:101px" %)Parameters|(% style="width:397px" %) 1086 -|(% style="width:101px" %)Example|(% style="width:397px" %) 1087 - 1088 1088 ==== 3.4.2.8 Trigger2 – Set DI2 as a trigger ==== 1089 1089 1090 1090 Sets DI2 as a trigger. ... ... @@ -1095,7 +1095,7 @@ 1095 1095 1096 1096 (% style="color:red" %)**b :** (%%)delay timing. 1097 1097 1098 -**Example:** AT+TRIG2=0,100 ( SettheDI1 port to trigger ona fallingedge;thevalid signalduration is 100983 +**Example:** AT+TRIG2=0,100 (set DI1 port to trigger on low level, valid signal is 100ms ) 1099 1099 1100 1100 1101 1101 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** ... ... @@ -1103,35 +1103,6 @@ 1103 1103 (% style="color:blue" %)**0x09 02 aa bb cc ** (%%)~/~/ same as AT+TRIG2=aa,0x(bb cc) 1104 1104 1105 1105 1106 -(% style="color:#037691" %)**AT Command** 1107 - 1108 -(% style="width:500px" %) 1109 -|(% style="width:94px" %)Command|(% style="width:404px" %)AT+TRIG=<interrupt_mode><minimum_signal_duration> 1110 -|(% style="width:94px" %)Response|(% style="width:404px" %) 1111 -|(% style="width:94px" %)Parameters|(% style="width:404px" %)((( 1112 -interrupt_mode : 0: falling edge; 1: rising edge, 2: falling and raising edge (for MOD=1). 1113 - 1114 -minimum_signal_duration : the **minimum signal duration** required for the DI1 port to recognize a valid trigger. 1115 -))) 1116 -|(% style="width:94px" %)Example|(% style="width:404px" %)((( 1117 -AT+TRIG2=0,100 1118 - 1119 -Set the DI1 port to trigger on a falling edge; the valid signal duration is 100 ms. 1120 -))) 1121 - 1122 -(% style="color:#037691" %)**Downlink Payload** 1123 - 1124 -(% style="width:500px" %) 1125 -|(% style="width:96px" %)Payload|(% style="width:402px" %)<prefix><interrupt_mode><minimum_signal_duration> 1126 -|(% style="width:96px" %)Parameters|(% style="width:402px" %)((( 1127 -prefix : 09 02 1128 - 1129 -interrupt_mode : 0: falling edge; 1: rising edge, 2: falling and raising edge (for MOD=1), represented by 1 byte in hexadecimal. 1130 - 1131 -<minimum_signal_duration>, represented two bytes in hexadecimal 1132 -))) 1133 -|(% style="width:96px" %)Example|(% style="width:402px" %)09 02 **00 00 64** 1134 - 1135 1135 ==== 3.4.2.9 Trigger – Set AC (current) as a trigger ==== 1136 1136 1137 1137 Sets the current trigger based on the AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -1143,18 +1143,7 @@ 1143 1143 (% style="color:blue" %)**0x AA 01 aa bb cc dd ee ff gg hh ** (%%) ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1144 1144 1145 1145 1146 -(% style="width:500px" %) 1147 -|(% style="width:104px" %)Command|(% style="width:394px" %)AT+ACLIM 1148 -|(% style="width:104px" %)Response|(% style="width:394px" %) 1149 -|(% style="width:104px" %)Parameters|(% style="width:394px" %)- 1150 -|(% style="width:104px" %)Example|(% style="width:394px" %)AT+ACLIM 1151 1151 1152 - 1153 -(% style="width:500px" %) 1154 -|(% style="width:104px" %)Payload|(% style="width:394px" %)<prefix> 1155 -|(% style="width:104px" %)Parameters|(% style="width:394px" %)prefix : AA 01 1156 -|(% style="width:104px" %)Example|(% style="width:394px" %)AA 01 aa bb cc dd ee ff gg hh 1157 - 1158 1158 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 1159 1159 1160 1160 Sets the current trigger based on the AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -1681,10 +1681,10 @@ 1681 1681 1682 1682 == 3.6 Interface Details == 1683 1683 1684 -=== 3.6.1 Digital Input Port s: DI1/DI2/DI3 (For LT-33222-L,LowActive ) ===1529 +=== 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === 1685 1685 1686 1686 1687 -Support sNPN-type sensors.1532 +Support NPN-type sensor 1688 1688 1689 1689 [[image:1653356991268-289.png]] 1690 1690