... ... @@ -23,6 +23,10 @@
23 23  
24 24  (((
25 25  (((
26 +{{info}}
27 +**This manual is also applicable to the LT-33222-L.**
28 +{{/info}}
29 +
26 26  The Dragino (% style="color:blue" %)**LT-22222-L I/O Controller**(%%) is an advanced LoRaWAN device designed to provide seamless wireless long-range connectivity with various I/O options, including analog current and voltage inputs, digital inputs and outputs, and relay outputs.
27 27  
28 28  The LT-22222-L I/O Controller simplifies and enhances I/O monitoring and controlling. It is ideal for professional applications in wireless sensor networks, including irrigation systems, smart metering, smart cities, building automation, and more. These controllers are designed for easy, cost-effective deployment using LoRa wireless technology.
... ... @@ -111,8 +111,9 @@
111 111  * Smart cities
112 112  * Smart factory
113 113  
114 -= 2. Assembling the device =
115 115  
119 +== 2. Assembling the device ==
120 +
116 116  == 2.1 Connecting the antenna ==
117 117  
118 118  Connect the LoRa antenna to the antenna connector, **ANT**,** **located on the top right side of the device, next to the upper screw terminal block. Secure the antenna by tightening it clockwise.
... ... @@ -1080,7 +1080,6 @@
1080 1080  |(% style="width:101px" %)Parameters|(% style="width:397px" %)
1081 1081  |(% style="width:101px" %)Example|(% style="width:397px" %)
1082 1082  
1083 -
1084 1084  ==== 3.4.2.8 Trigger2 – Set DI2 as a trigger ====
1085 1085  
1086 1086  Sets DI2 as a trigger.
... ... @@ -1146,13 +1146,11 @@
1146 1146  |(% style="width:104px" %)Example|(% style="width:394px" %)AT+ACLIM
1147 1147  
1148 1148  
1149 -
1150 1150  (% style="width:500px" %)
1151 1151  |(% style="width:104px" %)Payload|(% style="width:394px" %)<prefix>
1152 1152  |(% style="width:104px" %)Parameters|(% style="width:394px" %)prefix : AA 01
1153 1153  |(% style="width:104px" %)Example|(% style="width:394px" %)AA 01 aa bb cc dd ee ff gg hh
1154 1154  
1155 -
1156 1156  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
1157 1157  
1158 1158  Sets the current trigger based on the AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
... ... @@ -1679,10 +1679,10 @@
1679 1679  
1680 1680  == 3.6 Interface Details ==
1681 1681  
1682 -=== 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) ===
1684 +=== 3.6.1 Digital Input Ports: DI1/DI2/DI3 (For LT-33222-L, Low Active ) ===
1683 1683  
1684 1684  
1685 -Support NPN-type sensor
1687 +Supports NPN-type sensors.
1686 1686  
1687 1687  [[image:1653356991268-289.png]]