From version < 195.1 >
edited by Dilisi S
on 2024/11/16 06:34
To version < 196.1 >
edited by Dilisi S
on 2024/11/17 06:09
>
Change comment: Nov 16 edits

Summary

Details

Page properties
Content
... ... @@ -277,10 +277,10 @@
277 277  [[image:lt-22222-ul-payload-fmt.png||height="686" width="1000"]]
278 278  
279 279  
280 -== 3.3 Work Modes and Uplink Payload formats ==
280 +== 3.3 Working Modes and Uplink Payload formats ==
281 281  
282 282  
283 -The LT-22222-L has 5 **work modes**. It also has an interrupt/trigger mode for different types of applications that can be used together with any work mode as an additional feature. The default mode is MOD1 and you can switch between these modes using AT commands.
283 +The LT-22222-L has 5 **working modes**. It also has an interrupt/trigger mode for different types of applications that can be used together with any working mode as an additional feature. The default mode is MOD1 and you can switch between these modes using AT commands.
284 284  
285 285  * (% style="color:blue" %)**MOD1**(%%): (default mode/factory set): 2ACI + 2AVI + DI + DO + RO
286 286  
... ... @@ -294,7 +294,7 @@
294 294  
295 295  * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
296 296  
297 -The uplink messages are sent over LoRaWAN FPort 2. By default, an uplink message is sent every 10 minutes.
297 +The uplink messages are sent over LoRaWAN FPort=2. By default, an uplink message is sent every 10 minutes.
298 298  
299 299  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
300 300  
... ... @@ -303,7 +303,7 @@
303 303  
304 304  The uplink payload is 11 bytes long.
305 305  
306 -(% style="color:red" %)**Note:The maximum count depends on the bytes it is.
306 +(% style="color:red" %)**Note:The maximum count depends on the bytes number of bytes.
307 307  The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec).
308 308  It starts counting again when it reaches the maximum value.**(% style="display:none" wfd-invisible="true" %)
309 309  
... ... @@ -363,9 +363,13 @@
363 363  * [1] DO2 channel output is LOW, and the DO2 LED is ON.
364 364  * [0] DO1 channel output state:
365 365  ** DO1 is FLOATING when there is no load between DO1 and V+.
366 -** DO1 is HIGH when there is a load between DO1 and V+.
366 +** DO1 is HIGH and there is a load between DO1 and V+.
367 367  ** DO1 LED is OFF in both cases.
368 368  
369 +Reserve = 0
370 +
371 +MOD = 1
372 +
369 369  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
370 370  
371 371  
... ... @@ -621,24 +621,27 @@
621 621  )))
622 622  
623 623  
624 -=== 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
628 +=== 3.3.6 AT+ADDMOD~=6 (Trigger Mode, Optional) ===
625 625  
626 626  
627 -(% style="color:#4f81bd" %)**This mode is optional and intended for trigger purposes. It can operate together with other modes.**
631 +(% style="color:#4f81bd" %)**This mode is optional and intended for trigger purposes. It can operate __alongside__ with other modes.**
628 628  
629 -For example, if you configured the following commands:
633 +For example, if you configure the following commands:
630 630  
631 -* **AT+MOD=1 ** **~-~->**  The default work mode
632 -* **AT+ADDMOD6=1**   **~-~->**  Enable trigger mode
635 +* **AT+MOD=1 ** **~-~->**  Sets the default working mode
636 +* **AT+ADDMOD6=1**   **~-~->**  Enables trigger mode
633 633  
634 -The LT-22222-L will continuously monitor AV1, AV2, AC1, and AC2 every 5 seconds. LT will send uplink packets in two cases:
638 +The LT-22222-L will continuously monitor AV1, AV2, AC1, and AC2 every 5 seconds. It will send uplink packets in two cases:
635 635  
636 -1. Periodically uplink (Based on TDC time). The payload is the same as in normal mode (MOD=1 for the commands above). These are (% style="color:#4f81bd" %)**unconfirmed**(%%) uplinks.
640 +1. Periodic uplink: Based on TDC time. The payload is the same as in normal mode (MOD=1 as set above). These are (% style="color:#4f81bd" %)**unconfirmed**(%%) uplinks.
637 637  1. (((
638 -Trigger uplink when the trigger condition is met. LT will send two packets in this case. The first uplink uses the payload specified in trigger mode (MOD=6). The second packet uses the normal mode payload (MOD=1 as set above). Both are (% style="color:#4f81bd" %)**confirmed uplinks.**
642 +Trigger uplink: sent when a trigger condition is met. In this case, LT will send two packets
643 +
644 +* The first uplink uses the payload specified in trigger mode (MOD=6).
645 +* The second packet uses the normal mode payload (MOD=1 as set above). Both are (% style="color:#4f81bd" %)**confirmed uplinks.**
639 639  )))
640 640  
641 -(% style="color:#037691" %)**AT Commands to set Trigger Condition**:
648 +(% style="color:#037691" %)**AT Commands to set Trigger Conditions**:
642 642  
643 643  (% style="color:#4f81bd" %)**Trigger based on voltage**:
644 644  
... ... @@ -647,9 +647,9 @@
647 647  
648 648  **Example:**
649 649  
650 -AT+AVLIM=3000,6000,0,2000   (triggers an uplink if AVI1 voltage is lower than 3V or higher than 6V, or if AV2 voltage is higher than 2V)
657 +AT+AVLIM=3000,6000,0,2000 (triggers an uplink if AVI1 voltage is lower than 3V or higher than 6V, or if AV2 voltage is higher than 2V)
651 651  
652 -AT+AVLIM=5000,0,0,0   (triggers an uplink if AVI1 voltage lower than 5V. Use 0 for parameters that are not in use)
659 +AT+AVLIM=5000,0,0,0 (triggers an uplink if AVI1 voltage lower than 5V. Use 0 for parameters that are not in use)
653 653  
654 654  
655 655  (% style="color:#4f81bd" %)**Trigger based on current**:
... ... @@ -659,7 +659,7 @@
659 659  
660 660  **Example:**
661 661  
662 -AT+ACLIM=10000,15000,0,0   (triggers an uplink if ACI1 voltage is lower than 10mA or higher than 15mA)
669 +AT+ACLIM=10000,15000,0,0 (triggers an uplink if AC1 current is lower than 10mA or higher than 15mA)
663 663  
664 664  
665 665  (% style="color:#4f81bd" %)**Trigger based on DI status**:
... ... @@ -874,7 +874,6 @@
874 874  See [[RapidTables>>https://www.rapidtables.com/convert/number/decimal-to-hex.html?x=30000]]
875 875  )))
876 876  
877 -
878 878  ==== 3.4.2.2 Set the Working Mode (AT+MOD) ====
879 879  
880 880  Sets the working mode.
... ... @@ -905,7 +905,6 @@
905 905  Sets the device to working mode 2 (Double DI Counting + DO + RO)
906 906  )))
907 907  
908 -
909 909  (% class="wikigeneratedid" %)
910 910  (% style="color:#037691" %)**Downlink payload**
911 911  
... ... @@ -922,7 +922,6 @@
922 922  Sets the device to working mode 2 (Double DI Counting + DO + RO)
923 923  )))
924 924  
925 -
926 926  ==== 3.4.2.3 Poll an uplink ====
927 927  
928 928  Requests an uplink from LT-22222-L.
... ... @@ -942,7 +942,6 @@
942 942  Requests an uplink from LT-22222-L.
943 943  )))
944 944  
945 -
946 946  ==== 3.4.2.4 Enable/Disable Trigger Mode ====
947 947  
948 948  Enable or disable the trigger mode for the current working mode (see also [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]).
... ... @@ -980,58 +980,78 @@
980 980  Enable trigger mode for the current working mode
981 981  )))
982 982  
983 -
984 984  ==== 3.4.2.5 Poll trigger settings ====
985 985  
986 986  Polls the trigger settings.
987 987  
988 -* (% style="color:#037691" %)**AT Command:**
990 +(% style="color:#037691" %)**AT Command:**
989 989  
990 990  There is no AT Command for this feature.
991 991  
992 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):**
994 +(% style="color:#037691" %)**Downlink Payload**
993 993  
994 -(% style="color:blue" %)**0xAB 06  ** (%%) ~/~/ Poll the trigger settings. Device will uplink trigger settings once receive this command
995 -
996 -
997 997  (% style="width:500px" %)
998 998  |(% style="width:95px" %)**Payload**|(% style="width:403px" %)<prefix>
999 999  |(% style="width:95px" %)**Parameters**|(% style="width:403px" %)prefix : AB 06
1000 -|(% style="width:95px" %)**Example**|(% style="width:403px" %)AB 06
999 +|(% style="width:95px" %)**Example**|(% style="width:403px" %)(((
1000 +AB 06
1001 1001  
1002 +Uplinks the trigger settings.
1003 +)))
1002 1002  
1003 -==== 3.4.2.6 Enable / Disable DI1/DI2 as a trigger ====
1005 +==== 3.4.2.6 Enable/Disable DI1/DI2 as a trigger ====
1004 1004  
1005 1005  Enable or disable DI1/DI2 as a trigger.
1006 1006  
1007 -* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
1009 +(% style="color:#037691" %)**AT Command**
1008 1008  
1009 -**Example:** AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger)
1011 +(% style="width:500px" %)
1012 +|(% style="width:98px" %)Command|(% style="width:400px" %)AT+DTRI=<DI1_trigger><DI2_trigger>
1013 +|(% style="width:98px" %)Response|(% style="width:400px" %)
1014 +|(% style="width:98px" %)Parameters|(% style="width:400px" %)(((
1015 +DI1_trigger:
1010 1010  
1017 +1 = enable DI1 trigger
1011 1011  
1012 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):**
1019 +0 = disable DI1 trigger
1013 1013  
1014 -(% style="color:blue" %)**0xAA 02 aa bb   ** (%%) ~/~/ Same as AT+DTRI=aa,bb
1021 +DI2 _trigger
1015 1015  
1023 +1 = enable DI2 trigger
1016 1016  
1025 +0 = disable DI2 trigger
1026 +)))
1027 +|(% style="width:98px" %)Example|(% style="width:400px" %)(((
1028 +AT+DTRI=1,0
1029 +
1030 +Enable DI1 trigger, disable DI2 trigger
1031 +)))
1032 +
1033 +(% class="wikigeneratedid" %)
1034 +(% style="color:#037691" %)**Downlink Payload**
1035 +
1017 1017  (% style="width:500px" %)
1018 -|(% style="width:98px" %)Command|(% style="width:400px" %)AT+DTRI=<DI1_trigger><DI2_trigger>
1019 -|(% style="width:98px" %)Response|(% style="width:400px" %)
1020 -|(% style="width:98px" %)Parameters|(% style="width:400px" %)(((
1037 +|(% style="width:101px" %)Payload|(% style="width:397px" %)<prefix><DI1_trigger><DI2_trigger>
1038 +|(% style="width:101px" %)Parameters|(% style="width:397px" %)(((
1039 +prefix : AA 02
1040 +
1021 1021  DI1_trigger:
1022 1022  
1023 -1 = enable DI_1 trigger
1043 +1 = enable DI1 trigger, represented by 1 byte in hexadecimal.
1024 1024  
1025 -0 = disable DI_1 trigger
1045 +0 = disable DI1 trigger, represented by 1 byte in hexadecimal.
1026 1026  
1027 1027  DI2 _trigger
1028 1028  
1029 -1 = enable D2_1 trigger
1049 +1 = enable DI2 trigger, represented by 1 byte in hexadecimal.
1030 1030  
1031 -0 = disable D2_1 trigger
1051 +0 = disable DI2 trigger, represented by 1 byte in hexadecimal.
1032 1032  )))
1033 -|(% style="width:98px" %)Example|(% style="width:400px" %)
1053 +|(% style="width:101px" %)Example|(% style="width:397px" %)(((
1054 +AA 02 **01 00**
1034 1034  
1056 +Enable DI1 trigger, disable DI2 trigger
1057 +)))
1035 1035  
1036 1036  ==== 3.4.2.7 Trigger1 – Set DI or DI3 as a trigger ====
1037 1037  
... ... @@ -1051,6 +1051,13 @@
1051 1051  (% style="color:blue" %)**0x09 01 aa bb cc    ** (%%) ~/~/ same as AT+TRIG1=aa,0x(bb cc)
1052 1052  
1053 1053  
1077 +(% style="width:500px" %)
1078 +|(% style="width:101px" %)Command|(% style="width:397px" %)
1079 +|(% style="width:101px" %)Response|(% style="width:397px" %)
1080 +|(% style="width:101px" %)Parameters|(% style="width:397px" %)
1081 +|(% style="width:101px" %)Example|(% style="width:397px" %)
1082 +
1083 +
1054 1054  ==== 3.4.2.8 Trigger2 – Set DI2 as a trigger ====
1055 1055  
1056 1056  Sets DI2 as a trigger.
... ... @@ -1061,7 +1061,7 @@
1061 1061  
1062 1062  (% style="color:red" %)**b :** (%%)delay timing.
1063 1063  
1064 -**Example:** AT+TRIG2=0,100 (set DI1 port to trigger on low level, valid signal is 100ms )
1094 +**Example:** AT+TRIG2=0,100 (Set the DI1 port to trigger on a falling edge; the valid signal duration is 100 ms)
1065 1065  
1066 1066  
1067 1067  * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):**
... ... @@ -1069,6 +1069,35 @@
1069 1069  (% style="color:blue" %)**0x09 02 aa bb cc   ** (%%)~/~/ same as AT+TRIG2=aa,0x(bb cc)
1070 1070  
1071 1071  
1102 +(% style="color:#037691" %)**AT Command**
1103 +
1104 +(% style="width:500px" %)
1105 +|(% style="width:94px" %)Command|(% style="width:404px" %)AT+TRIG=<interrupt_mode><minimum_signal_duration>
1106 +|(% style="width:94px" %)Response|(% style="width:404px" %)
1107 +|(% style="width:94px" %)Parameters|(% style="width:404px" %)(((
1108 +interrupt_mode :  0: falling edge; 1: rising edge, 2: falling and raising edge (for MOD=1).
1109 +
1110 +minimum_signal_duration : the **minimum signal duration** required for the DI1 port to recognize a valid trigger.
1111 +)))
1112 +|(% style="width:94px" %)Example|(% style="width:404px" %)(((
1113 +AT+TRIG2=0,100
1114 +
1115 +Set the DI1 port to trigger on a falling edge; the valid signal duration is 100 ms.
1116 +)))
1117 +
1118 +(% style="color:#037691" %)**Downlink Payload**
1119 +
1120 +(% style="width:500px" %)
1121 +|(% style="width:96px" %)Payload|(% style="width:402px" %)<prefix><interrupt_mode><minimum_signal_duration>
1122 +|(% style="width:96px" %)Parameters|(% style="width:402px" %)(((
1123 +prefix : 09 02
1124 +
1125 +interrupt_mode : 0: falling edge; 1: rising edge, 2: falling and raising edge (for MOD=1), represented by 1 byte in hexadecimal.
1126 +
1127 +<minimum_signal_duration>, represented two bytes in hexadecimal
1128 +)))
1129 +|(% style="width:96px" %)Example|(% style="width:402px" %)09 02 **00 00 64**
1130 +
1072 1072  ==== 3.4.2.9 Trigger – Set AC (current) as a trigger ====
1073 1073  
1074 1074  Sets the current trigger based on the AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
... ... @@ -1080,7 +1080,20 @@
1080 1080  (% style="color:blue" %)**0x AA 01 aa bb cc dd ee ff gg hh        ** (%%) ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
1081 1081  
1082 1082  
1142 +(% style="width:500px" %)
1143 +|(% style="width:104px" %)Command|(% style="width:394px" %)AT+ACLIM
1144 +|(% style="width:104px" %)Response|(% style="width:394px" %)
1145 +|(% style="width:104px" %)Parameters|(% style="width:394px" %)-
1146 +|(% style="width:104px" %)Example|(% style="width:394px" %)AT+ACLIM
1083 1083  
1148 +
1149 +
1150 +(% style="width:500px" %)
1151 +|(% style="width:104px" %)Payload|(% style="width:394px" %)<prefix>
1152 +|(% style="width:104px" %)Parameters|(% style="width:394px" %)prefix : AA 01
1153 +|(% style="width:104px" %)Example|(% style="width:394px" %)AA 01 aa bb cc dd ee ff gg hh
1154 +
1155 +
1084 1084  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
1085 1085  
1086 1086  Sets the current trigger based on the AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]