Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -LT-22222-L -- LoRa I /O Controller User Manual1 +LT-22222-L -- LoRa IO Controller User Manual - Content
-
... ... @@ -40,9 +40,7 @@ 40 40 * If there is no public LoRaWAN coverage in your area, you can set up a LoRaWAN gateway, or multiple gateways, and connect them to a LoRaWAN network server to create adequate coverage. Then, register the LT-22222-L I/O controller with this network. 41 41 * Setup your own private LoRaWAN network. 42 42 43 -{{info}} 44 - You can use a LoRaWAN gateway, such as the [[Dragino LG308>>https://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], to expand or create LoRaWAN coverage in your area. 45 -{{/info}} 43 +> You can use a LoRaWAN gateway, such as the Dragino LG308, to expand or create LoRaWAN coverage in your area. 46 46 ))) 47 47 48 48 ((( ... ... @@ -58,13 +58,13 @@ 58 58 * STM32L072xxxx MCU 59 59 * SX1276/78 Wireless Chip 60 60 * Power Consumption: 61 -** Idle: 4mA@12 V59 +** Idle: 4mA@12v 62 62 ** 20dB Transmit: 34mA@12V 63 63 * Operating Temperature: -40 ~~ 85 Degrees, No Dew 64 64 65 65 (% style="color:#037691" %)**Interface for Model: LT22222-L:** 66 66 67 -* 2 x Digital dual direction Input (Detect High/Low signal, Max: 50 V, or 220Vwith optional external resistor)65 +* 2 x Digital dual direction Input (Detect High/Low signal, Max: 50v, or 220v with optional external resistor) 68 68 * 2 x Digital Output (NPN output. Max pull-up voltage 36V,450mA) 69 69 * 2 x Relay Output (5A@250VAC / 30VDC) 70 70 * 2 x 0~~20mA Analog Input (res:0.01mA) ... ... @@ -74,8 +74,8 @@ 74 74 (% style="color:#037691" %)**LoRa Spec:** 75 75 76 76 * Frequency Range: 77 -** Band 1 (HF): 862 ~~ 1020 M Hz78 -** Band 2 (LF): 410 ~~ 528 M Hz75 +** Band 1 (HF): 862 ~~ 1020 Mhz 76 +** Band 2 (LF): 410 ~~ 528 Mhz 79 79 * 168 dB maximum link budget. 80 80 * +20 dBm - 100 mW constant RF output vs. 81 81 * +14 dBm high-efficiency PA. ... ... @@ -94,7 +94,7 @@ 94 94 95 95 == 1.3 Features == 96 96 97 -* LoRaWAN Class A & Class C modes95 +* LoRaWAN Class A & Class C protocol 98 98 * Optional Customized LoRa Protocol 99 99 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865/MA869 100 100 * AT Commands to change parameters ... ... @@ -104,23 +104,34 @@ 104 104 105 105 == 1.4 Applications == 106 106 107 -* Smart buildings &homeautomation108 -* Logistics and supplychainmanagement109 -* Smart metering110 -* Smart agriculture111 -* Smart cities112 -* Smart factory105 +* Smart Buildings & Home Automation 106 +* Logistics and Supply Chain Management 107 +* Smart Metering 108 +* Smart Agriculture 109 +* Smart Cities 110 +* Smart Factory 113 113 114 -= 2.Assemblingthedevice=112 +== 1.5 Hardware Variants == 115 115 116 -== 2.1 Connecting the antenna == 117 117 118 -Connect the LoRa antenna to the antenna connector, **ANT**,** **located on the top right side of the device, next to the upper screw terminal block. Secure the antenna by tightening it clockwise. 115 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %) 116 +|(% style="background-color:#4f81bd; color:white; width:103px" %)**Model**|(% style="background-color:#4f81bd; color:white; width:131px" %)**Photo**|(% style="background-color:#4f81bd; color:white; width:266px" %)**Description** 117 +|(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)((( 118 +(% style="text-align:center" %) 119 +[[image:image-20230424115112-1.png||height="106" width="58"]] 120 +)))|(% style="width:334px" %)((( 121 +* 2 x Digital Input (Bi-direction) 122 +* 2 x Digital Output 123 +* 2 x Relay Output (5A@250VAC / 30VDC) 124 +* 2 x 0~~20mA Analog Input (res:0.01mA) 125 +* 2 x 0~~30V Analog Input (res:0.01v) 126 +* 1 x Counting Port 127 +))) 119 119 120 -{{warning}} 121 -Warning! Do not power on the device without connecting the antenna. 122 -{{/warning}} 129 += 2. Assembling = 123 123 131 +Attach the LoRa antenna to the antenna connector, **ANT**,** **located on the top right side of the device, next to the upper screw terminal block. Secure the antenna by tightening it clockwise. 132 + 124 124 == 2.2 Terminals == 125 125 126 126 The LT-22222-L has two screw terminal blocks. The upper screw treminal block has 6 terminals and the lower screw terminal block has 10 terminals. ... ... @@ -155,6 +155,8 @@ 155 155 156 156 The LT-22222-L I/O Controller can be powered by a **7–24V DC** power source. Connect your power supply’s positive wire to the VIN and the negative wire to the GND screw terminals. The power indicator **(PWR) LED** will turn on when the device is properly powered. 157 157 167 +Powering on the device 168 + 158 158 Once powered, the **TX LED** will **fast-blink 5 times** which means the LT-22222-L will enter the **work mode** and start to **join** The Things Stack. The **TX LED** will be on for **5 seconds** after joining the network. When there is a **downlink** message from the server, the **RX LED** will be on for **1 second**. When the device is sending an uplink message to the server, the **TX LED** will be on for **1 second**. See also LED status. 159 159 160 160 {{warning}} ... ... @@ -194,6 +194,7 @@ 194 194 * Go to your application page and click on the **End devices** in the left menu. 195 195 * On the End devices page, click on **+ Register end device**. Two registration options are available: 196 196 208 + 197 197 ==== 3.2.2.1 Using the LoRaWAN Device Repository ==== 198 198 199 199 * On the **Register end device** page: ... ... @@ -277,7 +277,7 @@ 277 277 [[image:lt-22222-ul-payload-fmt.png||height="686" width="1000"]] 278 278 279 279 280 -== 3.3 Work Modes and Uplink Payload formats == 292 +== 3.3 Work Modes and their Uplink Payload formats == 281 281 282 282 283 283 The LT-22222-L has 5 **work modes**. It also has an interrupt/trigger mode for different types of applications that can be used together with any work mode as an additional feature. The default mode is MOD1 and you can switch between these modes using AT commands. ... ... @@ -301,12 +301,8 @@ 301 301 ((( 302 302 This is the default mode. 303 303 304 -The uplink payload is 11 bytes long. 316 +The uplink payload is 11 bytes long. (% style="display:none" wfd-invisible="true" %) 305 305 306 -(% style="color:red" %)**Note:The maximum count depends on the bytes it is. 307 -The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec). 308 -It starts counting again when it reaches the maximum value.**(% style="display:none" wfd-invisible="true" %) 309 - 310 310 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 311 311 |(% style="background-color:#4f81bd; color:white" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1** 312 312 |Value|((( ... ... @@ -376,10 +376,6 @@ 376 376 ((( 377 377 The uplink payload is 11 bytes long. 378 378 379 -(% style="color:red" %)**Note:The maximum count depends on the bytes it is. 380 -The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec). 381 -It starts counting again when it reaches the maximum value.** 382 - 383 383 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 384 384 |(% style="background-color:#4f81bd; color:white" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white" %)**4**|(% style="background-color:#4f81bd; color:white" %)**4**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1** 385 385 |Value|COUNT1|COUNT2 |DIDORO*|((( ... ... @@ -444,9 +444,6 @@ 444 444 445 445 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 446 446 447 -(% style="color:red" %)**Note: The maximum count depends on the bytes it is. 448 -The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec). 449 -It starts counting again when it reaches the maximum value.** 450 450 451 451 **LT22222-L**: In this mode, the DI1 is used as a counting pin. 452 452 ... ... @@ -497,11 +497,7 @@ 497 497 498 498 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 499 499 500 -(% style="color:red" %)**Note:The maximum count depends on the bytes it is. 501 -The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec). 502 -It starts counting again when it reaches the maximum value.** 503 503 504 - 505 505 ((( 506 506 **LT22222-L**: In this mode, the DI1 is used as a counting pin. 507 507 ))) ... ... @@ -554,23 +554,19 @@ 554 554 ((( 555 555 **In addition to that, below are the commands for AVI1 Counting:** 556 556 557 -(% style="color:blue" %)**AT+SETCNT=3,60 554 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (Sets AVI Count to 60)** 558 558 559 -(% style="color:blue" %)**AT+VOLMAX=20000 556 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 560 560 561 -(% style="color:blue" %)**AT+VOLMAX=20000,0 558 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 562 562 563 -(% style="color:blue" %)**AT+VOLMAX=20000,1 560 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 564 564 ))) 565 565 566 566 567 567 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 568 568 569 -(% style="color:red" %)**Note:The maximum count depends on the bytes it is. 570 -The maximum count for four bytes is FFFFFFFF (hex) = 4294967295 (dec). 571 -It starts counting again when it reaches the maximum value.** 572 572 573 - 574 574 **LT22222-L**: In this mode, the DI1 is used as a counting pin. 575 575 576 576 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) ... ... @@ -628,17 +628,15 @@ 628 628 629 629 For example, if you configured the following commands: 630 630 631 -* **AT+MOD=1 ** **~-~->** The defaultwork mode624 +* **AT+MOD=1 ** **~-~->** The normal working mode 632 632 * **AT+ADDMOD6=1** **~-~->** Enable trigger mode 633 633 634 634 The LT-22222-L will continuously monitor AV1, AV2, AC1, and AC2 every 5 seconds. LT will send uplink packets in two cases: 635 635 636 636 1. Periodically uplink (Based on TDC time). The payload is the same as in normal mode (MOD=1 for the commands above). These are (% style="color:#4f81bd" %)**unconfirmed**(%%) uplinks. 637 -1. ((( 638 -Trigger uplink when the trigger condition is met. LT will send two packets in this case. The first uplink uses the payload specified in trigger mode (MOD=6). The second packet uses the normal mode payload (MOD=1 as set above). Both are (% style="color:#4f81bd" %)**confirmed uplinks.** 639 -))) 630 +1. Trigger uplink when the trigger condition is met. LT will send two packets in this case. The first uplink uses the payload specified in trigger mode (MOD=6). The second packet uses the normal mode payload (MOD=1 as set above). Both are (% style="color:#4f81bd" %)**CONFIRMED uplinks.** 640 640 641 -(% style="color:#037691" %)**AT Command sto set Trigger Condition**:632 +(% style="color:#037691" %)**AT Command to set Trigger Condition**: 642 642 643 643 (% style="color:#4f81bd" %)**Trigger based on voltage**: 644 644 ... ... @@ -810,68 +810,50 @@ 810 810 ))) 811 811 812 812 813 -== 3.4 Configure LT -22222-Lvia AT Commands or Downlinks ==804 +== 3.4 Configure LT via AT Commands or Downlinks == 814 814 806 + 815 815 ((( 816 - Youcan configure LT-22222-LI/O Controller via AT Commands or LoRaWAN Downlinks.808 +User can configure LT I/O Controller via AT Commands or LoRaWAN Downlinks. 817 817 ))) 818 818 819 819 ((( 820 820 ((( 821 -There are two tytes ofcommands:813 +There are two kinds of Commands: 822 822 ))) 823 823 ))) 824 824 825 -* (% style="color:blue" %)**Common commands**(%%):817 +* (% style="color:blue" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 826 826 827 -* (% style="color:blue" %)**Sensor -relatedcommands**(%%):819 +* (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 828 828 829 -=== 3.4.1 Common commands ===821 +=== 3.4.1 Common Commands === 830 830 831 831 ((( 832 -These a re available foreachsensorsandinclude actionssuch as changing the:[[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]s.824 +These commands should be available for all Dragino sensors, such as changing the uplink interval or resetting the device. For firmware v1.5.4, you can find the supported common commands under [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]. 833 833 ))) 834 834 835 -=== 3.4.2 Sensor-related commands === 836 836 837 - Thesecommandsarespecially designed fortheLT-22222-L. Commands can be sentto theeviceusing options such as an AT commandor a LoRaWAN downlink payload.828 +=== 3.4.2 Sensor related commands === 838 838 839 839 ==== 3.4.2.1 Set Transmit Interval ==== 840 840 841 841 Sets the uplink interval of the device. The default uplink transmission interval is 10 minutes. 842 842 843 -(% style="color:#037691" %)**AT command** 834 +* (% style="color:#037691" %)**AT command:** 844 844 845 -(% style="width:500px" %) 846 -|**Command**|AT+TDC<time> 847 -|**Response**| 848 -|**Parameters**|<time> uplink interval is in milliseconds 849 -|**Example**|((( 850 -AT+TDC=30000 836 +(% style="color:blue" %)**AT+TDC=N** 851 851 852 -Sets the uplink interval to 30,000 milliseconds (30 seconds) 853 -))) 838 +where N is the time in milliseconds. 854 854 855 - (% style="color:#037691"%)**Downlinkpayload**840 +**Example: **AT+TDC=30000. This will set the uplink interval to 30 seconds 856 856 857 -(% style="width:500px" %) 858 -|**Payload**|((( 859 -<prefix><time> 860 -))) 861 -|**Parameters**|((( 862 -<prefix> 0x01 863 863 864 -<time> uplink interval is in milliseconds, represented by 3 bytes in hexadecimal. 865 -))) 866 -|**Example**|((( 867 -01 **00 75 30** 843 +* (% style="color:#037691" %)**Downlink payload (prefix 0x01):** 868 868 869 - Setsthe uplink intervalto 30,000milliseconds(30seconds)845 +(% style="color:blue" %)**0x01 aa bb cc **(%%)** ~/~/ Same as AT+TDC=0x(aa bb cc)** 870 870 871 -Conversion: 30000 (dec) = 00 75 30 (hex) 872 872 873 -See [[RapidTables>>https://www.rapidtables.com/convert/number/decimal-to-hex.html?x=30000]] 874 -))) 875 875 876 876 ==== 3.4.2.2 Set the Work Mode (AT+MOD) ==== 877 877 ... ... @@ -893,8 +893,8 @@ 893 893 894 894 ==== 3.4.2.3 Poll an uplink ==== 895 895 896 -Requests the device to send an uplink. 897 897 870 +Asks the device to send an uplink. 898 898 899 899 * (% style="color:#037691" %)**AT command:**(%%) There is no AT Command to poll uplink 900 900 ... ... @@ -908,6 +908,7 @@ 908 908 909 909 ==== 3.4.2.4 Enable/Disable Trigger Mode ==== 910 910 884 + 911 911 Enable or disable the trigger mode (see also [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]). 912 912 913 913 * (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+ADDMOD6=1 or 0** ... ... @@ -925,8 +925,9 @@ 925 925 926 926 ==== 3.4.2.5 Poll trigger settings ==== 927 927 928 -Polls the trigger settings. 929 929 903 +Polls the trigger settings 904 + 930 930 * (% style="color:#037691" %)**AT Command:** 931 931 932 932 There is no AT Command for this feature. ... ... @@ -937,10 +937,11 @@ 937 937 938 938 939 939 940 -==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as atrigger ====915 +==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 941 941 942 -Enable or disable DI1/DI2/DI2 as a trigger. 943 943 918 +Enable or Disable DI1/DI2/DI2 as trigger, 919 + 944 944 * (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 945 945 946 946 **Example:** AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) ... ... @@ -952,10 +952,11 @@ 952 952 953 953 954 954 955 -==== 3.4.2.7 Trigger1 – Set DI or DI3 as atrigger ====931 +==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 956 956 957 -Sets DI1 or DI3 (for LT-33222-L) as a trigger. 958 958 934 +Set DI1 or DI3(for LT-33222-L) trigger. 935 + 959 959 * (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+TRIG1=a,b** 960 960 961 961 (% style="color:red" %)**a :** (%%)Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). ... ... @@ -970,10 +970,12 @@ 970 970 (% style="color:blue" %)**0x09 01 aa bb cc ** (%%) ~/~/ same as AT+TRIG1=aa,0x(bb cc) 971 971 972 972 973 -==== 3.4.2.8 Trigger2 – Set DI2 as a trigger ==== 974 974 975 -Set sDI2 asatrigger.951 +==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 976 976 953 + 954 +Sets DI2 trigger. 955 + 977 977 * (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+TRIG2=a,b** 978 978 979 979 (% style="color:red" %)**a :** (%%)Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge (for MOD=1). ... ... @@ -988,10 +988,12 @@ 988 988 (% style="color:blue" %)**0x09 02 aa bb cc ** (%%)~/~/ same as AT+TRIG2=aa,0x(bb cc) 989 989 990 990 991 -==== 3.4.2.9 Trigger – Set AC (current) as a trigger ==== 992 992 993 - Setsthecurrent triggerbasedon the ACport.See[[triggermode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]971 +==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 994 994 973 + 974 +Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 975 + 995 995 * (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+ACLIM** 996 996 997 997 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )** ... ... @@ -1002,8 +1002,9 @@ 1002 1002 1003 1003 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 1004 1004 1005 -Sets the current trigger based on the AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1006 1006 987 +Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 988 + 1007 1007 * (% style="color:#037691" %)**AT Command**(%%): (% style="color:blue" %)**AT+AVLIM **(%%)** See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 1008 1008 1009 1009 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )** ... ... @@ -1011,8 +1011,10 @@ 1011 1011 (% style="color:blue" %)**0x AA 00 aa bb cc dd ee ff gg hh ** (%%) ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1012 1012 1013 1013 996 + 1014 1014 ==== 3.4.2.11 Trigger – Set minimum interval ==== 1015 1015 999 + 1016 1016 Sets AV and AC trigger minimum interval. Device won't response to the second trigger within this set time after the first trigger. 1017 1017 1018 1018 * (% style="color:#037691" %)**AT Command**(%%): (% style="color:blue" %)**AT+ATDC=5 ** ~/~/ (%%)Device won't response the second trigger within 5 minute after the first trigger. ... ... @@ -1029,7 +1029,6 @@ 1029 1029 1030 1030 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1031 1031 1032 -Controls the digital outputs DO1, DO2, and DO3 1033 1033 1034 1034 * (% style="color:#037691" %)**AT Command** 1035 1035 ... ... @@ -1462,7 +1462,7 @@ 1462 1462 **Downlink data converter (this is an optional step):** 1463 1463 1464 1464 * Click the **Create new** button if it is not selected by default. 1465 -* Enter a suitable name for the downlink data converter in the **Name **text** **box or keep the default name .1448 +* Enter a suitable name for the downlink data converter in the **Name **text** **box or keep the default name 1466 1466 * Click the **JavaScript** button. 1467 1467 * Paste the downlink decoder function into the text area (first, delete the default code). The demo downlink decoder function can be found [[here>>https://raw.githubusercontent.com/ThingsEye-io/te-platform/refs/heads/main/Data%20Converters/The_Things_Network_MQTT_Downlink_Converter.js]]. 1468 1468 * Click the **Next** button. You will be navigated to the **Connection** tab. ... ... @@ -1474,7 +1474,7 @@ 1474 1474 1475 1475 * Choose **Region** from the **Host type**. 1476 1476 * Enter the **cluster** of your **The Things Stack** in the **Region** textbox. You can find the cluster in the url (e.g., https:~/~/**eu1**.cloud.thethings.network/...). 1477 -* Enter the **Username** and **Password** of the MQTT integration in the **Credentials** section. The **username**and**password**can be found on the MQTT integration page of your The Things Stack account (see Configuring The Things Stack).1460 +* Enter the **Username** and **Password** of the MQTT integration in the **Credentials** section. The username and password can be found on the MQTT integration page of your The Things Stack account (see Configuring MQTT Connection information with The Things Stack Sandbox). 1478 1478 * Click the **Check connection** button to test the connection. If the connection is successful, you will see the message saying **Connected**. 1479 1479 1480 1480 [[image:message-1.png]] ... ... @@ -1737,11 +1737,10 @@ 1737 1737 1738 1738 == 3.7 LEDs Indicators == 1739 1739 1740 -The table below lists the behavior of LED indicators for each port function. 1741 1741 1742 1742 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 1743 1743 |(% style="background-color:#4f81bd; color:white; width:50px" %)**LEDs**|(% style="background-color:#4f81bd; color:white; width:460px" %)**Feature** 1744 -|**PWR**|Always on whenthere is power1726 +|**PWR**|Always on if there is power 1745 1745 |**TX**|((( 1746 1746 ((( 1747 1747 Device boot: TX blinks 5 times. ... ... @@ -1748,7 +1748,7 @@ 1748 1748 ))) 1749 1749 1750 1750 ((( 1751 -Successful network join: TXremainsON for 5 seconds.1733 +Successful join network: TX ON for 5 seconds. 1752 1752 ))) 1753 1753 1754 1754 ((( ... ... @@ -1755,7 +1755,7 @@ 1755 1755 Transmit a LoRa packet: TX blinks once 1756 1756 ))) 1757 1757 ))) 1758 -|**RX**|RX blinks once when a packet is received.1740 +|**RX**|RX blinks once when receiving a packet. 1759 1759 |**DO1**|For LT-22222-L: ON when DO1 is low, OFF when DO1 is high 1760 1760 |**DO2**|For LT-22222-L: ON when DO2 is low, OFF when DO2 is high 1761 1761 |**DI1**|((( ... ... @@ -1794,7 +1794,7 @@ 1794 1794 ))) 1795 1795 1796 1796 ((( 1797 -The following is the list of all the AT commands related to the LT-22222-L, except for those used for switching between work ingmodes.1779 +The following is the list of all the AT commands related to the LT-22222-L, except for those used for switching between work modes. 1798 1798 1799 1799 * AT+<CMD>? : Help on <CMD> 1800 1800 * AT+<CMD> : Run <CMD> ... ... @@ -1853,28 +1853,28 @@ 1853 1853 1854 1854 1855 1855 ((( 1856 -(% style="color:blue" %)**If the device has not yetjoined the network:**1838 +(% style="color:blue" %)**If the device has not joined the network yet:** 1857 1857 ))) 1858 1858 ))) 1859 1859 1860 1860 ((( 1861 -(% style="background-color:#dcdcdc" %)##**123456 ~/~/ Enter the password to enable AT commands access**##1843 +(% style="background-color:#dcdcdc" %)##**123456 ~/~/enable AT commands access**## 1862 1862 ))) 1863 1863 1864 1864 ((( 1865 -(% style="background-color:#dcdcdc" %)##**AT+FDR ~/~/ Reset parameters to factory default,Reserve keys**##1847 +(% style="background-color:#dcdcdc" %)##**AT+FDR ~/~/reset parameters to factory default, reserve keys**## 1866 1866 ))) 1867 1867 1868 1868 ((( 1869 -(% style="background-color:#dcdcdc" %)##**123456 ~/~/ Enter the password to enable AT commands access**##1851 +(% style="background-color:#dcdcdc" %)##**123456 ~/~/enable AT commands access**## 1870 1870 ))) 1871 1871 1872 1872 ((( 1873 -(% style="background-color:#dcdcdc" %)##**AT+NJM=0 ~/~/ Set to ABP mode**##1855 +(% style="background-color:#dcdcdc" %)##**AT+NJM=0 ~/~/set to ABP mode**## 1874 1874 ))) 1875 1875 1876 1876 ((( 1877 -(% style="background-color:#dcdcdc" %)##**ATZ ~/~/ Reset MCU**##1859 +(% style="background-color:#dcdcdc" %)##**ATZ ~/~/reset MCU**## 1878 1878 ))) 1879 1879 1880 1880 ... ... @@ -1897,20 +1897,20 @@ 1897 1897 1898 1898 1899 1899 ((( 1900 -(% style="background-color:#dcdcdc" %)**123456**(%%) ~/~/ Enter password toenable ATcommands access1882 +(% style="background-color:#dcdcdc" %)**123456**(%%) ~/~/ Enter Password to have AT access. 1901 1901 ))) 1902 1902 ))) 1903 1903 1904 1904 ((( 1905 -(% style="background-color:#dcdcdc" %)** AT+FDR**(%%) ~/~/ Reset parameters to Factory Default, Reservekeys1887 +(% style="background-color:#dcdcdc" %)** AT+FDR**(%%) ~/~/ Reset Parameters to Factory Default, Keys Reserve 1906 1906 ))) 1907 1907 1908 1908 ((( 1909 -(% style="background-color:#dcdcdc" %)** 123456**(%%) ~/~/ Enter password toenable ATcommands access1891 +(% style="background-color:#dcdcdc" %)** 123456**(%%) ~/~/ Enter Password to have AT access. 1910 1910 ))) 1911 1911 1912 1912 ((( 1913 -(% style="background-color:#dcdcdc" %)** AT+CLASS=C**(%%) ~/~/ Set to CLASS C mode1895 +(% style="background-color:#dcdcdc" %)** AT+CLASS=C**(%%) ~/~/ Set to work in CLASS C 1914 1914 ))) 1915 1915 1916 1916 ((( ... ... @@ -1930,19 +1930,19 @@ 1930 1930 ))) 1931 1931 1932 1932 ((( 1933 -(% style="background-color:#dcdcdc" %)** AT+CHS=868400000**(%%) ~/~/ Set transmit frequency to 868.4 Hz1915 +(% style="background-color:#dcdcdc" %)** AT+CHS=868400000**(%%) ~/~/ Set transmit frequency to 868.4Mhz 1934 1934 ))) 1935 1935 1936 1936 ((( 1937 -(% style="background-color:#dcdcdc" %)** AT+RX2FQ=868400000**(%%) ~/~/ Set RX2 frequency to 868.4Hz (according to the result fromtheserver)1919 +(% style="background-color:#dcdcdc" %)** AT+RX2FQ=868400000**(%%) ~/~/ Set RX2Frequency to 868.4Mhz (according to the result from server) 1938 1938 ))) 1939 1939 1940 1940 ((( 1941 -(% style="background-color:#dcdcdc" %)** AT+RX2DR=5**(%%)** ** ~/~/ Set RX2 theserver.See below.1923 +(% style="background-color:#dcdcdc" %)** AT+RX2DR=5**(%%)** ** ~/~/ Set RX2DR to match the downlink DR from server. see below 1942 1942 ))) 1943 1943 1944 1944 ((( 1945 -(% style="background-color:#dcdcdc" %)** AT+DADDR=26 01 1A F1** (%%) ~/~/ Set Device Address .TheDeviceAddresscan be found in theapplication on theLoRaWANNS.1927 +(% style="background-color:#dcdcdc" %)** AT+DADDR=26 01 1A F1** (%%) ~/~/ Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1946 1946 ))) 1947 1947 1948 1948 ((( ... ... @@ -1956,14 +1956,14 @@ 1956 1956 ))) 1957 1957 1958 1958 ((( 1959 -**~1. Ensure that the device is set to ABP mode in theLoRaWANNetworkServer.**1941 +**~1. Make sure the device is set to ABP mode in the IoT Server.** 1960 1960 1961 -**2. Verifythat the LG01/02 gateway RX frequencymatchesthe AT+CHS settingexactly.**1943 +**2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.** 1962 1962 1963 -**3. Make sure theSF/bandwidth settingsintheLG01/LG02 match the settings of AT+DR.Referto[[this link>>url:http://www.dragino.com/downloads/index.php?1945 +**3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php? 1964 1964 dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.** 1965 1965 1966 -**4. The command sAT+RX2FQ and AT+RX2DRenable downlinkfunctionality.To set the correct parameters,you can check the actual downlink parameters to be usedasshownbelow.Here,RX2FQ shouldbesetto868400000 and RX2DR should beset to5.**1948 +**4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5.** 1967 1967 ))) 1968 1968 1969 1969 ((( ... ... @@ -1987,18 +1987,20 @@ 1987 1987 1988 1988 == 5.1 Counting how many objects pass through the flow Line == 1989 1989 1990 -See [[How to set up to setup counting for objects passing through the flow line>>How to set up to count objects pass in flow line]]? 1991 1991 1973 +Reference Link: [[How to set up to setup counting for objects passing through the flow line>>How to set up to count objects pass in flow line]]? 1992 1992 1975 + 1993 1993 = 6. FAQ = 1994 1994 1995 1995 This section contains some frequently asked questions, which can help you resolve common issues and find solutions quickly. 1996 1996 1997 - 1998 1998 == 6.1 How to update the firmware? == 1999 1999 2000 -Dragino frequently releases firmware updates for the LT-22222-L. Updating your LT-22222-L with the latest firmware version helps to:1982 +Dragino frequently releases firmware updates for the LT-22222-L. 2001 2001 1984 +Updating your LT-22222-L with the latest firmware version helps to: 1985 + 2002 2002 * Support new features 2003 2003 * Fix bugs 2004 2004 * Change LoRaWAN frequency bands ... ... @@ -2016,8 +2016,8 @@ 2016 2016 2017 2017 Below is the hardware setup for uploading a firmware image to the LT-22222-L: 2018 2018 2019 -[[image:usb-ttl-programming.png]] 2020 2020 2004 +[[image:1653359603330-121.png]] 2021 2021 2022 2022 2023 2023 Start the STM32 Flash Loader and choose the correct COM port to update. ... ... @@ -2041,7 +2041,7 @@ 2041 2041 [[image:image-20220524104033-15.png]] 2042 2042 2043 2043 2044 -(% style="color:red" %)**Note**(%%): If you have lost the programming cable, you can make one from a 3.5 2028 +(% style="color:red" %)**Note**(%%): If you have lost the programming cable, you can make one from a 3.5mm cable. The pin mapping is as follows: 2045 2045 2046 2046 [[image:1653360054704-518.png||height="186" width="745"]] 2047 2047 ... ... @@ -2049,6 +2049,8 @@ 2049 2049 ((( 2050 2050 ((( 2051 2051 == 6.2 How to change the LoRaWAN frequency band/region? == 2036 + 2037 + 2052 2052 ))) 2053 2053 ))) 2054 2054 ... ... @@ -2059,18 +2059,20 @@ 2059 2059 ((( 2060 2060 2061 2061 2062 -== 6.3 How to setup LT-22222-L to work with a Single Channel Gateway, such as LG01/LG02? == 2048 +== 6.3 How to setup LT to work with a Single Channel Gateway, such as LG01/LG02? == 2049 + 2050 + 2063 2063 ))) 2064 2064 2065 2065 ((( 2066 2066 ((( 2067 -In this case, you need to set the LT-222 22-L to work in ABP mode and transmit on only one frequency.2055 +In this case, you need to set the LT-33222-L to work in ABP mode and transmit on only one frequency. 2068 2068 ))) 2069 2069 ))) 2070 2070 2071 2071 ((( 2072 2072 ((( 2073 - We assume you have an LG01/LG02 working on the frequency 868400000. Below are the steps.2061 +Assume you have an LG02 working on the frequency 868400000. Below are the steps. 2074 2074 2075 2075 2076 2076 ))) ... ... @@ -2077,55 +2077,52 @@ 2077 2077 ))) 2078 2078 2079 2079 ((( 2080 -(% style="color:#0000ff" %)**Step 1**(%%): andboxaccount and create an ABP device in the application. To do this,use the manual registration option as explained insection 3.2.2.2, //Adding a Device Manually//. Select//Activationby Personalization (ABP)// under Activation Mode. Enter theDevEUI exactly as shownontheregistrationinformation sticker,then generate the Device Address, ApplicationSessionKey (AppSKey),andNetworkSession Key (NwkSKey).2068 +(% style="color:#0000ff" %)**Step 1**(%%): Log in to The Things Stack SANDBOX, create an ABP device in the application, and input the Network Session key (NwkSKey), App session key (AppSKey) of the device. 2081 2081 2082 - [[image:lt-22222-l-abp.png||height="686"width="1000"]]2070 + 2083 2083 ))) 2084 2084 2085 2085 ((( 2074 +[[image:1653360231087-571.png||height="401" width="727"]] 2075 + 2086 2086 2087 2087 ))) 2088 2088 2089 - {{warning}}2090 - Ensure that theDevice Address(DevAddr)andthe two keysmatchbetweentheLT-22222-L and TheThingsStack.Youcanmodify themeither in TheThingsStackoron theLT-22222-Lto make themalign. In TheThingsStack,youcan configurethe NwkSKeyand AppSKeyonthesettingspage, butnote that theDevice Addressis generated by TheThings Stack.2091 - {{/warning}}2079 +((( 2080 +(% style="color:red" %)**Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN.** 2081 +))) 2092 2092 2093 2093 2084 + 2094 2094 ((( 2095 -(% style="color:blue" %)**Step (% style="color:#000000; font-family:Arial,sans-serif; font-size:11pt; font-style:normal; font-variant-alternates:normal; font-variant-east-asian:normal; font-variant-ligatures:normal; font-variant-numeric:normal; font-variant-position:normal; font-weight:400; text-decoration:none; white-space:pre-wrap" %)Run ATcommandstoconfiguretheLT-22222-Ltooperateinsingle-frequencyandABP mode.The AT commandsare as follows:2086 +(% style="color:blue" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands: 2096 2096 2097 2097 2098 2098 ))) 2099 2099 2100 2100 ((( 2101 -(% style="background-color:#dcdcdc" %)**123456** (%%) : Enter the password toenable AT access.2092 +(% style="background-color:#dcdcdc" %)**123456** (%%) : Enter Password to have AT access. 2102 2102 2103 -(% style="background-color:#dcdcdc" %)**AT+FDR**(%%) : Reset parameters tofactorydefault,keeping keysreserved.2094 +(% style="background-color:#dcdcdc" %)**AT+FDR**(%%) : Reset Parameters to Factory Default, Keys Reserve 2104 2104 2105 -(% style="background-color:#dcdcdc" %)**AT+NJM=0** (%%) : Set to ABP mode .2096 +(% style="background-color:#dcdcdc" %)**AT+NJM=0** (%%) : Set to ABP mode 2106 2106 2107 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) : Disable the Adaptive Data Rate(ADR).2098 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) : Set the Adaptive Data Rate Off 2108 2108 2109 -(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) : Set Data Rate ( Use AT+DR=3 forthe915MHzband).2100 +(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) : Set Data Rate (Set AT+DR=3 for 915 band) 2110 2110 2111 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000 **(%%) : Set transmit interval to 60 seconds .2102 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000 **(%%) : Set transmit interval to 60 seconds 2112 2112 2113 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) : Set transmit frequency to 868.4 Hz.2104 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) : Set transmit frequency to 868.4Mhz 2114 2114 2115 -(% style="background-color:#dcdcdc" %)**AT+DADDR= xxxx**(%%) : SettheDevice Address(DevAddr)2106 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26 01 1A F1**(%%) : Set Device Address to 26 01 1A F1 2116 2116 2117 -(% style="color:#000000; font-family:Arial,sans-serif; font-size:11pt; font-style:normal; font-variant-alternates:normal; font-variant-east-asian:normal; font-variant-ligatures:normal; font-variant-numeric:normal; font-variant-position:normal; font-weight:700; text-decoration:none; white-space:pre-wrap" %)**AT+APPKEY=xxxx**(% style="color:#000000; font-family:Arial,sans-serif; font-size:11pt; font-style:normal; font-variant-alternates:normal; font-variant-east-asian:normal; font-variant-ligatures:normal; font-variant-numeric:normal; font-variant-position:normal; font-weight:400; text-decoration:none; white-space:pre-wrap" %): Get or set the Application Key (AppKey) 2118 - 2119 -(% style="color:#000000; font-family:Arial,sans-serif; font-size:11pt; font-style:normal; font-variant-alternates:normal; font-variant-east-asian:normal; font-variant-ligatures:normal; font-variant-numeric:normal; font-variant-position:normal; font-weight:400; text-decoration:none; white-space:pre-wrap" %)**AT+NWKSKEY=xxxx**: Get or set the Network Session Key (NwkSKey) 2120 - 2121 -(% style="color:#000000; font-family:Arial,sans-serif; font-size:11pt; font-style:normal; font-variant-alternates:normal; font-variant-east-asian:normal; font-variant-ligatures:normal; font-variant-numeric:normal; font-variant-position:normal; font-weight:400; text-decoration:none; white-space:pre-wrap" %)**AT+APPSKEY=xxxx**: Get or set the Application Session Key (AppSKey) 2122 - 2123 -(% style="background-color:#dcdcdc" %)**ATZ** (%%) : Reset MCU. 2108 +(% style="background-color:#dcdcdc" %)**ATZ** (%%) : Reset MCU 2124 2124 ))) 2125 2125 2126 2126 2127 2127 ((( 2128 - (% style="color:#000000; font-family:Arial,sans-serif;font-size:11pt; font-style:normal; font-variant-alternates:normal; font-variant-east-asian:normal; font-variant-ligatures:normal; font-variant-numeric:normal; font-variant-position:normal; font-weight:400; text-decoration:none;white-space:pre-wrap" %)The followingfigure shows the screenshotof the command set above, issued using a serialtool:2113 +As shown in below: 2129 2129 ))) 2130 2130 2131 2131 [[image:1653360498588-932.png||height="485" width="726"]] ... ... @@ -2133,33 +2133,35 @@ 2133 2133 2134 2134 == 6.4 How to change the uplink interval? == 2135 2135 2121 + 2136 2136 Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/]] 2137 2137 2138 2138 2139 2139 == 6.5 Can I see the counting event in the serial output? == 2140 2140 2127 + 2141 2141 ((( 2142 -You can run the AT command **AT+DEBUG**to view the counting event in the serial output. If the firmware is too old and doesn’t support AT+DEBUG, update to the latest firmware first.2129 +You can run the AT command AT+DEBUG to view the counting event in the serial output. If the firmware is too old and doesn’t support AT+DEBUG, update to the latest firmware first. 2143 2143 2144 2144 2145 2145 == 6.6 Can I use point-to-point communication with LT-22222-L? == 2146 2146 2147 -Yes, you can. Please refer to the [[Point-to-Point Communication of LT-22222-L>>https://wiki.dragino.com/xwiki/bin/view/Main/%20Point%20to%20Point%20Communication%20of%20LT-22222-L/]] page. The firmware that supports point-to-point communication can be found [[here>>https://github.com/dragino/LT-22222-L/releases]]. 2148 2148 2149 - 2135 +Yes, you can. Please refer to the [[Point-to-Point Communication of LT-22222-L>>https://wiki.dragino.com/xwiki/bin/view/Main/%20Point%20to%20Point%20Communication%20of%20LT-22222-L/]] page. The firmware that supports point-to-point communication can be found [[here>>https://github.com/dragino/LT-22222-L/releases]]. 2150 2150 ))) 2151 2151 2152 2152 ((( 2153 2153 == 6.7 Why does the relay output default to an open relay after the LT-22222-L is powered off? == 2154 2154 2141 + 2155 2155 * If the device is not properly shut down and is directly powered off. 2156 2156 * It will default to a power-off state. 2157 2157 * In modes 2 to 5, the DO/RO status and pulse count are saved to flash memory. 2158 2158 * After a restart, the status before the power failure will be read from flash. 2159 2159 2160 - 2161 2161 == 6.8 Can I setup LT-22222-L as a NC (Normally Closed) relay? == 2162 2162 2149 + 2163 2163 The LT-22222-L's built-in relay is Normally Open (NO). You can use an external relay to achieve a Normally Closed (NC) configuration. The circuit diagram is shown below: 2164 2164 2165 2165 ... ... @@ -2168,24 +2168,24 @@ 2168 2168 2169 2169 == 6.9 Can the LT-22222-L save the RO state? == 2170 2170 2171 -To enable this feature, the firmware version must be 1.6.0 or higher. 2172 2172 2159 +The firmware version must be at least 1.6.0. 2173 2173 2161 + 2174 2174 == 6.10 Why does the LT-22222-L always report 15.585V when measuring the AVI? == 2175 2175 2164 + 2176 2176 It is likely that the GND is not connected during the measurement, or that the wire connected to the GND is loose. 2177 2177 2178 2178 2179 2179 = 7. Troubleshooting = 2180 - 2181 -This section provides some known troubleshooting tips. 2182 - 2183 - 2184 2184 ))) 2185 2185 2186 2186 ((( 2187 2187 ((( 2188 2188 == 7.1 Downlink isn't working. How can I solve this? == 2174 + 2175 + 2189 2189 ))) 2190 2190 ))) 2191 2191 ... ... @@ -2197,6 +2197,8 @@ 2197 2197 2198 2198 2199 2199 == 7.2 Having trouble uploading an image? == 2187 + 2188 + 2200 2200 ))) 2201 2201 2202 2202 ((( ... ... @@ -2207,6 +2207,8 @@ 2207 2207 2208 2208 2209 2209 == 7.3 Why can't I join TTN in the US915 /AU915 bands? == 2199 + 2200 + 2210 2210 ))) 2211 2211 2212 2212 ((( ... ... @@ -2214,8 +2214,9 @@ 2214 2214 ))) 2215 2215 2216 2216 2217 -== 7.4 Why can the LT-22222-L perform uplink normally, but cannot receivedownlink? ==2208 +== 7.4 Why can the LT-22222-L perform Uplink normally, but cannot receive Downlink? == 2218 2218 2210 + 2219 2219 The FCD count of the gateway is inconsistent with the FCD count of the node, causing the downlink to remain in the queue. 2220 2220 Use this command to synchronize their counts: [[Resets the downlink packet count>>||anchor="H3.4.2.23Resetsthedownlinkpacketcount"]] 2221 2221 ... ... @@ -2222,6 +2222,7 @@ 2222 2222 2223 2223 = 8. Ordering information = 2224 2224 2217 + 2225 2225 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 2226 2226 2227 2227 (% style="color:#4f81bd" %)**XXX:** ... ... @@ -2236,8 +2236,8 @@ 2236 2236 * (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 2237 2237 * (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 2238 2238 2232 += 9. Packing information = 2239 2239 2240 -= 9. Package information = 2241 2241 2242 2242 **Package includes**: 2243 2243 ... ... @@ -2244,7 +2244,7 @@ 2244 2244 * 1 x LT-22222-L I/O Controller 2245 2245 * 1 x LoRa antenna matched to the frequency of the LT-22222-L 2246 2246 * 1 x bracket for DIN rail mounting 2247 -* 1 x 3.5 2240 +* 1 x 3.5mm programming cable 2248 2248 2249 2249 **Dimension and weight**: 2250 2250 ... ... @@ -2253,9 +2253,9 @@ 2253 2253 * Package Size / pcs : 14.5 x 8 x 5 cm 2254 2254 * Weight / pcs : 170 g 2255 2255 2256 - 2257 2257 = 10. Support = 2258 2258 2251 + 2259 2259 * ((( 2260 2260 Support is available Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different time zones, we cannot offer live support. However, your questions will be answered as soon as possible within the aforementioned schedule. 2261 2261 ))) ... ... @@ -2267,6 +2267,7 @@ 2267 2267 2268 2268 = 11. Reference = 2269 2269 2263 + 2270 2270 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2271 2271 * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 2272 2272 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]]
- lt-22222-l-abp.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.pradeeka - Size
-
... ... @@ -1,1 +1,0 @@ 1 -321.4 KB - Content
- usb-ttl-programming.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.pradeeka - Size
-
... ... @@ -1,1 +1,0 @@ 1 -462.9 KB - Content