Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -17,7 +17,7 @@ 17 17 18 18 19 19 20 -= 1. 20 += 1.Introduction = 21 21 22 22 == 1.1 What is the LT-22222-L I/O Controller? == 23 23 ... ... @@ -42,7 +42,7 @@ 42 42 * If there is no public LoRaWAN coverage in your area, you can set up a LoRaWAN gateway, or multiple gateways, and connect them to a LoRaWAN network server to create adequate coverage. Then, register the LT-22222-L I/O controller with this network. 43 43 * Setup your own private LoRaWAN network. 44 44 45 -> You can use a LoRaWAN gateway, suchas the Dragino LG308,to expand or create LoRaWAN coverage in your area.45 +> You can use the Dragino LG308 gateway to expand or create LoRaWAN coverage in your area. 46 46 ))) 47 47 48 48 ((( ... ... @@ -60,12 +60,12 @@ 60 60 * Power Consumption: 61 61 ** Idle: 4mA@12v 62 62 ** 20dB Transmit: 34mA@12v 63 -* Operating Temperature: -40 ~~ 85 Degree s, No Dew63 +* Operating Temperature: -40 ~~ 85 Degree, No Dew 64 64 65 65 (% style="color:#037691" %)**Interface for Model: LT22222-L:** 66 66 67 67 * 2 x Digital dual direction Input (Detect High/Low signal, Max: 50v, or 220v with optional external resistor) 68 -* 2 x Digital Output (NPN output. Max pull -up voltage 36V,450mA)68 +* 2 x Digital Output (NPN output. Max pull up voltage 36V,450mA) 69 69 * 2 x Relay Output (5A@250VAC / 30VDC) 70 70 * 2 x 0~~20mA Analog Input (res:0.01mA) 71 71 * 2 x 0~~30V Analog Input (res:0.01v) ... ... @@ -78,7 +78,7 @@ 78 78 ** Band 2 (LF): 410 ~~ 528 Mhz 79 79 * 168 dB maximum link budget. 80 80 * +20 dBm - 100 mW constant RF output vs. 81 -* +14 dBm high -efficiency PA.81 +* +14 dBm high efficiency PA. 82 82 * Programmable bit rate up to 300 kbps. 83 83 * High sensitivity: down to -148 dBm. 84 84 * Bullet-proof front end: IIP3 = -12.5 dBm. ... ... @@ -98,7 +98,7 @@ 98 98 * Optional Customized LoRa Protocol 99 99 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865/MA869 100 100 * AT Commands to change parameters 101 -* Remote lyconfigure parameters via LoRaWANDownlink101 +* Remote configure parameters via LoRa Downlink 102 102 * Firmware upgradable via program port 103 103 * Counting 104 104 ... ... @@ -139,7 +139,7 @@ 139 139 * 1 x bracket for wall mounting 140 140 * 1 x programming cable 141 141 142 -Attach the LoRaWAN antenna to the antennaconnector,ANT,****located on the top right side of the device, next to the upper terminal block. Secure the antenna by tightening it clockwise.142 +Attach the LoRaWAN antenna to the connector labeled **ANT** (located on the top right side of the device, next to the upper terminal block). Secure the antenna by tightening it clockwise. 143 143 144 144 == 2.2 Terminals == 145 145 ... ... @@ -169,9 +169,9 @@ 169 169 |(% style="width:296px" %)DO2|(% style="width:334px" %)Digital Output 2 170 170 |(% style="width:296px" %)DO1|(% style="width:334px" %)Digital Output 1 171 171 172 -== 2.3 Powering the LT-22222-L==172 +== 2.3 Powering == 173 173 174 -The LT-22222-L I/O Controller can be powered by a 7–24V DC power source. Connect the power supply’s positive wire to the VIN and the negative wire to the GND screw terminal s. The power indicator (PWR) LED will turn on when the device is properly powered.174 +The LT-22222-L I/O Controller can be powered by a 7–24V DC power source. Connect the power supply’s positive wire to the VIN screw terminal and the negative wire to the GND screw terminal. The power indicator (PWR) LED will turn on when the device is properly powered. 175 175 176 176 177 177 [[image:1653297104069-180.png]] ... ... @@ -181,9 +181,9 @@ 181 181 182 182 == 3.1 How does it work? == 183 183 184 - By default, the LT-22222-L is configured to operate in LoRaWAN Class C mode. It supports OTAA (Over-the-Air Activation), the most secure method for activating a device with a LoRaWAN network server. The LT-22222-L comes with device registration information that allows you to register it with a LoRaWAN network, enabling the device to perform OTAA activation with the network server upon initial power-up and after any subsequent reboots.184 +The LT-22222-L is configured to operate in LoRaWAN Class C mode by default. It supports OTAA (Over-the-Air Activation), which is the most secure method for activating a device with a LoRaWAN network server. The LT-22222-L comes with device registration information that allows you to register it with a LoRaWAN network, enabling the device to perform OTAA activation with the network server upon initial power-up and after any subsequent reboots. 185 185 186 -For LT-22222-L, the LED will show the Join status: After power ingon,the TX LED will fast-blink 5 timeswhich means theLT-22222-L will entertheworking mode and start to JOINtheLoRaWAN network.The TX LED will be on for 5 seconds after joiningthenetwork. When there isamessage fromtheserver, the RX LED will be on for 1 second.186 +For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 187 187 188 188 In case you can't set the root key and other identifiers in the network server and must use them from the server, you can use [[AT Commands>>||anchor="H4.UseATCommand"]] to configure them on the device. 189 189 ... ... @@ -205,7 +205,7 @@ 205 205 206 206 * Log in to your [[The Things Stack Sandbox>>https://eu1.cloud.thethings.network]] account. 207 207 * Create an application if you do not have one yet. 208 -* Register LT-22222-L with that application. Two registration options a re available:208 +* Register LT-22222-L with that application. Two registration options available: 209 209 210 210 ==== Using the LoRaWAN Device Repository: ==== 211 211 ... ... @@ -213,12 +213,12 @@ 213 213 * On the **Register end device** page: 214 214 ** Select the option **Select the end device in the LoRaWAN Device Repository**. 215 215 ** Choose the **End device brand**, **Model**, **Hardware version**, **Firmware version**, and **Profile (Region)**. 216 -** Select the **Frequency plan** that matches your device. 216 +** Select the **Frequency plan** that matches with your device. 217 217 218 218 [[image:lt-22222-l-dev-repo-reg-p1.png||height="625" width="1000"]] 219 219 220 220 * 221 -** Enter the **AppEUI** in the **JoinEUI** field and click the**Confirm** button.221 +** Enter the **AppEUI** in the **JoinEUI** field and click **Confirm** button. 222 222 ** Enter the **DevEUI** in the **DevEUI** field. 223 223 ** Enter the **AppKey** in the **AppKey** field. 224 224 ** In the **End device ID** field, enter a unique name within this application for your LT-22222-N. ... ... @@ -229,26 +229,19 @@ 229 229 ==== Entering device information manually: ==== 230 230 231 231 * On the **Register end device** page: 232 -** Select the **Enter end device specifie smanually** optionas the input method.233 -** Select the **Frequency plan** that matches your device. 232 +** Select the **Enter end device specified manually** option. 233 +** Select the **Frequency plan** that matches with your device. 234 234 ** Select the **LoRaWAN version**. 235 235 ** Select the **Regional Parameters version**. 236 -** Click **Show advanced activation, LoRaWAN class and cluster settings** link toexpandthe section.237 -** Select **Over the air activation (OTAA)** option under the**Activation mode**236 +** Click **Show advanced activation, LoRaWAN class and cluster settings** option. 237 +** Select **Over the air activation (OTAA)** option under **Activation mode** 238 238 ** Select **Class C (Continuous)** from the **Additional LoRaWAN class capabilities**. 239 +** Enter **AppEUI** in the **JoinEUI** field and click **Confirm** button. 240 +** Enter **DevEUI** in the **DevEUI** field. 241 +** Enter **AppKey** in the **AppKey** field. 242 +** In the **End device ID** field, enter a unique name within this application for your LT-22222-N. 243 +** Under **After registration**, select the **View registered end device** option. 239 239 240 -[[image:lt-22222-l-manually-p1.png||height="625" width="1000"]] 241 - 242 - 243 -* Enter **AppEUI** in the **JoinEUI** field and click the **Confirm** button. 244 -* Enter **DevEUI** in the **DevEUI** field. 245 -* Enter **AppKey** in the **AppKey** field. 246 -* In the **End device ID** field, enter a unique name within this application for your LT-22222-N. 247 -* Under **After registration**, select the **View registered end device** option. 248 - 249 -[[image:lt-22222-l-manually-p2.png||height="625" width="1000"]] 250 - 251 - 252 252 ==== Joining ==== 253 253 254 254 Click on **Live Data** in the left navigation. Then, power on the device, and it will join The Things Stack Sandbox. You can see the join request, join accept, followed by uplink messages form the device showing in the Live Data panel. ... ... @@ -256,12 +256,12 @@ 256 256 [[image:1653298044601-602.png||height="405" width="709"]] 257 257 258 258 259 -== 3.3 Work Modes and theirUplink Payloadformats==252 +== 3.3 Uplink Payload == 260 260 261 261 262 -The LT-22222-L has5**work modes**.Italsohas an interrupt/triggermode for different typesofapplications that can be used together with any working mode as an additional feature. The default mode is MOD1 and you can switch between these modes using AT commands.255 +There are five working modes + one interrupt mode on LT for different type application: 263 263 264 -* (% style="color:blue" %)**MOD1**(%%): (default mode/factoryset): 2ACI + 2AVI + DI + DO + RO257 +* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO 265 265 266 266 * (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO 267 267 ... ... @@ -275,8 +275,9 @@ 275 275 276 276 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 277 277 271 + 278 278 ((( 279 -The uplink payload is 11byteslong. UplinkmessagesaresentoverLoRaWANFPort2. By default,one uplinkis sent every10 minutes. (% style="display:none"wfd-invisible="true"%)273 +The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. (% style="display:none" %) 280 280 281 281 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 282 282 |(% style="background-color:#4f81bd; color:white" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1** ... ... @@ -288,29 +288,29 @@ 288 288 ACI1 Current 289 289 )))|((( 290 290 ACI2 Current 291 -)))| **DIDORO***|(((285 +)))|DIDORO*|((( 292 292 Reserve 293 293 )))|MOD 294 294 ))) 295 295 296 296 ((( 297 -(% style="color:#4f81bd" %)** *DIDORO**(%%) is a combinationof RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1,andits size is1longasshownbelow.291 +(% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 298 298 299 299 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 300 -|**bit 301 -|RO1|RO2| --DI3--|DI2|DI1|--DO3--|DO2|DO1294 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 295 +|RO1|RO2|DI3|DI2|DI1|DO3|DO2|DO1 302 302 ))) 303 303 304 -* RO is for therelay. ROx=1:CLOSED, ROx=0 alwaysOPEN.305 -* DI is for digital input. DIx=1: HIGHorFLOATING, DIx=0:LOW.306 -* DO is for reverse digital output. DOx=1: LOW, DOx=0:HIGHorFLOATING.298 +* RO is for relay. ROx=1 : close, ROx=0 always open. 299 +* DI is for digital input. DIx=1: high or float, DIx=0: low. 300 +* DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 307 307 308 -(% style="color:red" %)**Note: DI3 and DO3 bit sare not valid for LT-22222-L**302 +(% style="color:red" %)**Note: DI3 and DO3 bit are not valid for LT-22222-L** 309 309 310 -For example ,ifthepayload is: [[image:image-20220523175847-2.png]]304 +For example if payload is: [[image:image-20220523175847-2.png]] 311 311 312 312 313 -**The interfacevaluescanbecalculatedasfollows: **307 +**The value for the interface is: ** 314 314 315 315 AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V 316 316 ... ... @@ -320,32 +320,35 @@ 320 320 321 321 ACI2 channel current is 0x1300/1000=4.864mA 322 322 323 -The last byte 0xAA= **10101010**(b) means,317 +The last byte 0xAA= 10101010(B) means 324 324 325 -* [1] The RO1 relay channel is CLOSED, and the RO1 LED is ON. 326 -* [0] The RO2 relay channel is OPEN, and the RO2 LED is OFF. 327 -* [1] DI3 - not used for LT-22222-L. 328 -* [0] DI2 channel input is LOW, and the DI2 LED is OFF. 329 -* [1] DI1 channel input state: 330 -** DI1 is FLOATING when no sensor is connected between DI1+ and DI1-. 331 -** DI1 is HIGH when a sensor is connected between DI1- and DI1+ and the sensor is ACTIVE. 332 -** DI1 LED is ON in both cases. 333 -* [0] DO3 - not used for LT-22222-L. 334 -* [1] DO2 channel output is LOW, and the DO2 LED is ON. 335 -* [0] DO1 channel output state: 336 -** DO1 is FLOATING when there is no load between DO1 and V+. 337 -** DO1 is HIGH when there is a load between DO1 and V+. 338 -** DO1 LED is OFF in both cases. 319 +* [1] RO1 relay channel is close and the RO1 LED is ON. 320 +* [0] RO2 relay channel is open and RO2 LED is OFF; 339 339 322 +**LT22222-L:** 323 + 324 +* [1] DI2 channel is high input and DI2 LED is ON; 325 +* [0] DI1 channel is low input; 326 + 327 +* [0] DO3 channel output state 328 +** DO3 is float in case no load between DO3 and V+.; 329 +** DO3 is high in case there is load between DO3 and V+. 330 +** DO3 LED is off in both case 331 +* [1] DO2 channel output is low and DO2 LED is ON. 332 +* [0] DO1 channel output state 333 +** DO1 is float in case no load between DO1 and V+.; 334 +** DO1 is high in case there is load between DO1 and V+. 335 +** DO1 LED is off in both case 336 + 340 340 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 341 341 342 342 343 343 ((( 344 -**For LT-22222-L**: Inthis mode,**DI1 and DI2** are used as counting pins.341 +**For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. 345 345 ))) 346 346 347 347 ((( 348 -T he uplink payloadis11 bytes long.345 +Total : 11 bytes payload 349 349 350 350 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 351 351 |(% style="background-color:#4f81bd; color:white" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white" %)**4**|(% style="background-color:#4f81bd; color:white" %)**4**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1** ... ... @@ -355,26 +355,26 @@ 355 355 ))) 356 356 357 357 ((( 358 -(% style="color:#4f81bd" %)** *DIDORO**(%%) is a combinationof RO1, RO2, DO3, DO2 and DO1,andits size is1longasshownbelow.355 +(% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 359 359 360 360 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 361 -|**bit 362 -|RO1|RO2|FIRST|Reserve|Reserve| --DO3--|DO2|DO1358 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 359 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 363 363 364 - *RO is fortherelay. ROx=1:CLOSED,OPEN.361 +RO is for relay. ROx=1 : close , ROx=0 always open. 365 365 ))) 366 366 367 -* FIRST: Indicate sthat this is the first packet after joiningthenetwork.368 -* DO is for reverse digital output. DOx=1: LOW, DOx=0:HIGHorFLOATING.364 +* FIRST: Indicate this is the first packet after join network. 365 +* DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 369 369 370 370 ((( 371 -(% style="color:red" %)**Note: DO3 bit is not valid for LT-22222-L** 368 +(% style="color:red" %)**Note: DO3 bit is not valid for LT-22222-L.** 372 372 373 373 374 374 ))) 375 375 376 376 ((( 377 -**To activate thismode,run the following AT commands:**374 +**To use counting mode, please run:** 378 378 ))) 379 379 380 380 ((( ... ... @@ -395,17 +395,17 @@ 395 395 ((( 396 396 **For LT22222-L:** 397 397 398 -(% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set stheDI1 port to trigger onaLOWlevel.Thevalid signalduration is 100ms) **395 +(% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger on low level, valid signal is 100ms) ** 399 399 400 -(% style="color:blue" %)**AT+TRIG1=1,100**(%%)** (set stheDI1 port to trigger onaHIGHlevel.Thevalid signalduration is 100ms) **397 +(% style="color:blue" %)**AT+TRIG1=1,100**(%%)** (set DI1 port to trigger on high level, valid signal is 100ms ) ** 401 401 402 -(% style="color:blue" %)**AT+TRIG2=0,100**(%%)** (set stheDI2 port to trigger onaLOWlevel.Thevalid signalduration is 100ms) **399 +(% style="color:blue" %)**AT+TRIG2=0,100**(%%)** (set DI2 port to trigger on low level, valid signal is 100ms) ** 403 403 404 -(% style="color:blue" %)**AT+TRIG2=1,100**(%%)** (set stheDI2 port to trigger onaHIGHlevel.Thevalid signalduration is 100ms) **401 +(% style="color:blue" %)**AT+TRIG2=1,100**(%%)** (set DI2 port to trigger on high level, valid signal is 100ms ) ** 405 405 406 -(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** ( setstheCOUNT1 value to 60)**403 +(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 407 407 408 -(% style="color:blue" %)**AT+SETCNT=2,60 setstheCOUNT2 value to 60)**405 +(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 409 409 ))) 410 410 411 411 ... ... @@ -412,7 +412,7 @@ 412 412 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 413 413 414 414 415 -**LT22222-L**: In this mode,the DI1 is used as a counting pin.412 +**LT22222-L**: This mode the DI1 is used as a counting pin. 416 416 417 417 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 418 418 |(% style="background-color:#4f81bd; color:white" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white" %)**4**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1** ... ... @@ -423,24 +423,24 @@ 423 423 )))|DIDORO*|Reserve|MOD 424 424 425 425 ((( 426 -(% style="color:#4f81bd" %)** *DIDORO**(%%) is a combinationof RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1,for atotalof1,asshownbelow.423 +(% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 427 427 428 428 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 429 -|**bit 430 -|RO1|RO2|FIRST|Reserve|Reserve| --DO3--|DO2|DO1426 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 427 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 431 431 ))) 432 432 433 -* RO is for therelay. ROx=1: closed, ROx=0 always open.434 -* FIRST: Indicate sthat this is the first packet after joiningthenetwork.435 -* DO is for reverse digital output. DOx=1: output low, DOx=0: high or float ing.430 +* RO is for relay. ROx=1 : close, ROx=0 always open. 431 +* FIRST: Indicate this is the first packet after join network. 432 +* DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 436 436 437 437 ((( 438 -(% style="color:red" %)**Note: DO3 bit is not valid for LT-22222-L.**435 +(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.** 439 439 ))) 440 440 441 441 442 442 ((( 443 -**To activate thismode,run the following AT commands:**440 +**To use counting mode, please run:** 444 444 ))) 445 445 446 446 ((( ... ... @@ -453,9 +453,7 @@ 453 453 ))) 454 454 455 455 ((( 456 -AT Commands for counting: 457 - 458 -The AT Commands for counting are similar to the [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]s. 453 +Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 459 459 ))) 460 460 461 461 ... ... @@ -463,11 +463,11 @@ 463 463 464 464 465 465 ((( 466 -**LT22222-L**: In this mode,the DI1 is used as a counting pin.461 +**LT22222-L**: This mode the DI1 is used as a counting pin. 467 467 ))) 468 468 469 469 ((( 470 -The AVI1 is also used for counting. It monitor sthe voltageandchecksit every**60econds**.Ifthevoltage is higher or lower than VOLMAX mV, the AVI1count increasesby1,allowingAVI1 countingtobe used to measure a machine'sworking hours.465 +The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. 471 471 472 472 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 473 473 |(% style="background-color:#4f81bd; color:white" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white" %)**4**|(% style="background-color:#4f81bd; color:white" %)**4**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1** ... ... @@ -477,25 +477,25 @@ 477 477 ))) 478 478 479 479 ((( 480 -(% style="color:#4f81bd" %)**DIDORO **(%%)is a combination of RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1,for atotalof1,asshownbelow.475 +(% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 481 481 482 482 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 483 -|**bit 484 -|RO1|RO2|FIRST|Reserve|Reserve| --DO3--|DO2|DO1478 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 479 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 485 485 ))) 486 486 487 -* RO is for therelay. ROx=1: closed, ROx=0 always open.488 -* FIRST: Indicate sthat this is the first packet after joiningthenetwork.489 -* DO is for reverse digital output. DOx=1: output low, DOx=0: high or float ing.482 +* RO is for relay. ROx=1 : close, ROx=0 always open. 483 +* FIRST: Indicate this is the first packet after join network. 484 +* DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 490 490 491 491 ((( 492 -(% style="color:red" %)**Note: DO3 bit is not valid for LT-22222-L.**487 +(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.** 493 493 494 494 495 495 ))) 496 496 497 497 ((( 498 -**To activate this mode,run the following AT commands:**493 +**To use this mode, please run:** 499 499 ))) 500 500 501 501 ((( ... ... @@ -508,19 +508,19 @@ 508 508 ))) 509 509 510 510 ((( 511 -Other AT Commands for counting are similar to the[[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]s.506 +Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 512 512 ))) 513 513 514 514 ((( 515 -** Inaddition to that,beloware thecommandsfor AVI1 Counting:**510 +**Plus below command for AVI1 Counting:** 516 516 517 -(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** ( SetsAVI Count to 60)**512 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 518 518 519 519 (% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 520 520 521 521 (% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 522 522 523 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage hig her than VOLMAX (20000mV =20v), counter increase 1)**518 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 524 524 ))) 525 525 526 526 ... ... @@ -527,7 +527,7 @@ 527 527 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 528 528 529 529 530 -**LT22222-L**: In this mode,the DI1 is used as a counting pin.525 +**LT22222-L**: This mode the DI1 is used as a counting pin. 531 531 532 532 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 533 533 |(% style="background-color:#4f81bd; color:white" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1** ... ... @@ -542,25 +542,25 @@ 542 542 )))|MOD 543 543 544 544 ((( 545 -(% style="color:#4f81bd" %)**DIDORO**(%%) is a combination of RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1,for atotalof1,asshownbelow.540 +(% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 546 546 547 547 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 548 -|**bit 543 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 549 549 |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 550 550 ))) 551 551 552 -* RO is for therelay. ROx=1: closed, ROx=0 always open.553 -* FIRST: Indicate sthat this is the first packet after joiningthenetwork.547 +* RO is for relay. ROx=1 : close, ROx=0 always open. 548 +* FIRST: Indicate this is the first packet after join network. 554 554 * ((( 555 -DO is for reverse digital output. DOx=1: output low, DOx=0: high or float ing.550 +DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 556 556 ))) 557 557 558 558 ((( 559 -(% style="color:red" %)**Note: DO3 bit is not valid for LT-22222-L.**554 +(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.** 560 560 ))) 561 561 562 562 ((( 563 -**To activate this mode,run the following AT commands:**558 +**To use this mode, please run:** 564 564 ))) 565 565 566 566 ((( ... ... @@ -573,7 +573,7 @@ 573 573 ))) 574 574 575 575 ((( 576 -Other AT Commands for counting are similar to the[[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]s.571 +Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 577 577 ))) 578 578 579 579 ... ... @@ -580,46 +580,49 @@ 580 580 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 581 581 582 582 583 -(% style="color:#4f81bd" %)**This mode is optional andintendedfor trigger purposes. It canoperatetogether with other modes.**578 +(% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.** 584 584 585 -For example, if you configuredthefollowingcommands:580 +For example, if user has configured below commands: 586 586 587 587 * **AT+MOD=1 ** **~-~->** The normal working mode 588 -* **AT+ADDMOD6=1** **~-~->** Enable trigger mode583 +* **AT+ADDMOD6=1** **~-~->** Enable trigger 589 589 590 - TheLT-22222-Lwillcontinuouslymonitor AV1,AV2,AC1, andAC2 every 5 seconds.LT will send uplink packets in two cases:585 +LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 591 591 592 -1. Periodically uplink (Base don TDC time).The payload isthesame asinnormalmode(MOD=1 forthe commands above). These are(% style="color:#4f81bd" %)**unconfirmed**(%%)uplinks.593 -1. Trigger uplink when the trigger condition is met. LT will sendtwo packets in this case. The first uplink usesthepayload specifiedin triggermode(MOD=6). The second packetsthe normal modepayloadassetabove). Bothareuplinks.**587 +1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 588 +1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 594 594 595 595 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 596 596 597 -(% style="color:#4f81bd" %)**Trigger based on voltage**: 598 598 593 +(% style="color:#4f81bd" %)**Trigger base on voltage**: 594 + 599 599 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> 600 600 601 601 602 602 **Example:** 603 603 604 -AT+AVLIM=3000,6000,0,2000 ( triggers an uplink if AVI1 voltageislower than 3Vor higher than 6V,orifAV2 voltage is higher than 2V)600 +AT+AVLIM=3000,6000,0,2000 (If AVI1 voltage lower than 3v or higher than 6v. or AV2 voltage is higher than 2v, LT will trigger Uplink) 605 605 606 -AT+AVLIM=5000,0,0,0 ( triggers an uplink if AVI1 voltage lower than 5V.Use0 forparametersthatarenotinuse)602 +AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 607 607 608 608 609 -(% style="color:#4f81bd" %)**Trigger based on current**: 610 610 606 +(% style="color:#4f81bd" %)**Trigger base on current**: 607 + 611 611 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> 612 612 613 613 614 614 **Example:** 615 615 616 -AT+ACLIM=10000,15000,0,0 ( triggers an uplink if ACI1 voltageislower than 10mA or higher than 15mA)613 +AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 617 617 618 618 619 -(% style="color:#4f81bd" %)**Trigger based on DI status**: 620 620 621 - DIstatustriggersFlag.617 +(% style="color:#4f81bd" %)**Trigger base on DI status**: 622 622 619 +DI status trigger Flag. 620 + 623 623 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 624 624 625 625 ... ... @@ -628,38 +628,39 @@ 628 628 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 629 629 630 630 631 -(% style="color:#037691" %)** LoRaWANDownlink CommandsforSettingtheTrigger Conditions:**629 +(% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 632 632 633 633 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 634 634 635 635 Format: AA xx yy1 yy1 yy2 yy2 yy3 yy3 yy4 yy4 636 636 637 - AA: TypeCode for this downlink Command:635 + AA: Code for this downlink Command: 638 638 639 - xx: **0**: Limit for AV1 and AV2;**1**: limit for AC1 and AC2;**2**:DI1andDI2 trigger enable/disable.637 + xx: 0: Limit for AV1 and AV2; 1: limit for AC1 and AC2 ; 2 DI1, DI2 trigger enable/disable 640 640 641 - yy1 yy1: AC1 or AV1 LOWlimit or DI1/DI2 trigger status.639 + yy1 yy1: AC1 or AV1 low limit or DI1/DI2 trigger status. 642 642 643 - yy2 yy2: AC1 or AV1 HIGHlimit.641 + yy2 yy2: AC1 or AV1 high limit. 644 644 645 - yy3 yy3: AC2 or AV2 LOWlimit.643 + yy3 yy3: AC2 or AV2 low limit. 646 646 647 - Yy4 yy4: AC2 or AV2 HIGHlimit.645 + Yy4 yy4: AC2 or AV2 high limit. 648 648 649 649 650 -**Example 648 +**Example1**: AA 00 13 88 00 00 00 00 00 00 651 651 652 -Same as AT+AVLIM=5000,0,0,0 ( triggers an uplink if AVI1 voltageislower than 5V.Use0s forparametersthatarenotinuse)650 +Same as AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 653 653 654 654 655 -**Example 653 +**Example2**: AA 02 01 00 656 656 657 -Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 655 +Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 658 658 659 659 658 + 660 660 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 661 661 662 -MOD6 Payload: total of11 bytes661 +MOD6 Payload : total 11 bytes payload 663 663 664 664 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 665 665 |(% style="background-color:#4f81bd; color:white; width:60px" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white; width:69px" %)**1**|(% style="background-color:#4f81bd; color:white; width:69px" %)**1**|(% style="background-color:#4f81bd; color:white; width:109px" %)**1**|(% style="background-color:#4f81bd; color:white; width:49px" %)**6**|(% style="background-color:#4f81bd; color:white; width:109px" %)**1**|(% style="background-color:#4f81bd; color:white; width:50px" %)**1** ... ... @@ -673,10 +673,10 @@ 673 673 MOD(6) 674 674 ))) 675 675 676 -(% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if t he trigger is set for this part. Totally 1675 +(% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below 677 677 678 678 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 679 -|**bit 678 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 680 680 |((( 681 681 AV1_LOW 682 682 )))|((( ... ... @@ -695,17 +695,17 @@ 695 695 AC2_HIGH 696 696 ))) 697 697 698 -* Each bit shows if the corresponding trigger has been configured. 697 +* Each bits shows if the corresponding trigger has been configured. 699 699 700 700 **Example:** 701 701 702 -10100000: Means the system has configure to use the trigger: A V1_LOW and AV2_LOW701 +10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW 703 703 704 704 705 -(% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1 704 +(% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1byte as below 706 706 707 707 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 708 -|**bit 707 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 709 709 |((( 710 710 AV1_LOW 711 711 )))|((( ... ... @@ -724,11 +724,11 @@ 724 724 AC2_HIGH 725 725 ))) 726 726 727 -* Each bit shows which status has been trigger edon this uplink.726 +* Each bits shows which status has been trigger on this uplink. 728 728 729 729 **Example:** 730 730 731 -10000000: Means this uplink is triggeredby AV1_LOW.That meansthevoltageistoo low.730 +10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. 732 732 733 733 734 734 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below ... ... @@ -737,7 +737,7 @@ 737 737 |**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 738 738 |N/A|N/A|N/A|N/A|DI2_STATUS|DI2_FLAG|DI1_STATUS|DI1_FLAG 739 739 740 -* Each bits shows which status has been trigger edon this uplink.739 +* Each bits shows which status has been trigger on this uplink. 741 741 742 742 **Example:** 743 743 ... ... @@ -764,11 +764,11 @@ 764 764 ))) 765 765 766 766 767 -== 3.4 Configure LT via AT Commands or Downlinks==766 +== 3.4 Configure LT via AT or Downlink == 768 768 769 769 770 770 ((( 771 -User can configure LT I/O Controller via AT Commands or LoRaWAN Downlinks .770 +User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands 772 772 ))) 773 773 774 774 ((( ... ... @@ -794,37 +794,33 @@ 794 794 ==== 3.4.2.1 Set Transmit Interval ==== 795 795 796 796 797 -Set sthe uplink interval of thedevice.The default uplinktransmissionintervalis 10 minutes.796 +Set device uplink interval. 798 798 799 -* (% style="color:#037691" %)**AT command:**798 +* (% style="color:#037691" %)**AT Command:** 800 800 801 -(% style="color:blue" %)**AT+TDC=N** 800 +(% style="color:blue" %)**AT+TDC=N ** 802 802 803 -where N is the time in milliseconds. 804 804 805 -**Example: **AT+TDC=30000. Thiswillsetthe uplink interval to 30 seconds803 +**Example: **AT+TDC=30000. Means set interval to 30 seconds 806 806 807 807 808 -* (% style="color:#037691" %)**Downlink payload (prefix 0x01):**806 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 809 809 810 810 (% style="color:blue" %)**0x01 aa bb cc **(%%)** ~/~/ Same as AT+TDC=0x(aa bb cc)** 811 811 812 812 813 813 814 -==== 3.4.2.2 Set theWork Mode (AT+MOD) ====812 +==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 815 815 816 816 817 -Set sthework mode.815 +Set work mode. 818 818 819 -* (% style="color:#037691" %)**AT command:**(%%) (% style="color:blue" %)**AT+MOD=N **817 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+MOD=N ** 820 820 821 - WhereNis the work mode.819 +**Example**: AT+MOD=2. Set work mode to Double DI counting mode 822 822 823 -* *Example**:AT+MOD=2.Thiswill set the workmode toDouble DI countingmode.821 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 824 824 825 - 826 -* (% style="color:#037691" %)**Downlink payload (prefix 0x0A):** 827 - 828 828 (% style="color:blue" %)**0x0A aa **(%%)** ** ~/~/ Same as AT+MOD=aa 829 829 830 830 ... ... @@ -832,12 +832,10 @@ 832 832 ==== 3.4.2.3 Poll an uplink ==== 833 833 834 834 835 - Asksthe devicetosendan uplink.830 +* (% style="color:#037691" %)**AT Command:**(%%) There is no AT Command to poll uplink 836 836 837 -* (% style="color:#037691" %)** AT command:**(%%) ThereisnoAT Commandtopoll uplink832 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):** 838 838 839 -* (% style="color:#037691" %)**Downlink payload (prefix 0x08):** 840 - 841 841 (% style="color:blue" %)**0x08 FF **(%%)** **~/~/ Poll an uplink 842 842 843 843 **Example**: 0x08FF, ask device to send an Uplink ... ... @@ -844,16 +844,16 @@ 844 844 845 845 846 846 847 -==== 3.4.2.4 Enable /DisableTrigger Mode ====840 +==== 3.4.2.4 Enable Trigger Mode ==== 848 848 849 849 850 - Enable ordisablethe trigger mode(seealso[[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]).843 +Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 851 851 852 852 * (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+ADDMOD6=1 or 0** 853 853 854 -(% style="color:red" %)**1:** (%%)Enable the triggermode847 +(% style="color:red" %)**1:** (%%)Enable Trigger Mode 855 855 856 -(% style="color:red" %)**0: **(%%)Disable the triggermode849 +(% style="color:red" %)**0: **(%%)Disable Trigger Mode 857 857 858 858 859 859 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):** ... ... @@ -865,7 +865,7 @@ 865 865 ==== 3.4.2.5 Poll trigger settings ==== 866 866 867 867 868 -Poll sthe trigger settings861 +Poll trigger settings 869 869 870 870 * (% style="color:#037691" %)**AT Command:** 871 871 ... ... @@ -873,7 +873,7 @@ 873 873 874 874 * (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 875 875 876 -(% style="color:blue" %)**0xAB 06 ** (%%) ~/~/ Poll t he trigger settings.Device will uplink trigger settings once receive this command869 +(% style="color:blue" %)**0xAB 06 ** (%%) ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 877 877 878 878 879 879 ... ... @@ -880,11 +880,11 @@ 880 880 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 881 881 882 882 883 -Enable orDisable DI1/DI2/DI2 as trigger,876 +Enable Disable DI1/DI2/DI2 as trigger, 884 884 885 885 * (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 886 886 887 -**Example:** AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 880 +**Example:** AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 888 888 889 889 890 890 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** ... ... @@ -916,15 +916,15 @@ 916 916 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 917 917 918 918 919 -Set sDI2 trigger.912 +Set DI2 trigger. 920 920 921 921 * (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+TRIG2=a,b** 922 922 923 -(% style="color:red" %)**a :** (%%)Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge 916 +(% style="color:red" %)**a :** (%%)Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 924 924 925 925 (% style="color:red" %)**b :** (%%)delay timing. 926 926 927 -**Example:** AT+TRIG2=0,100 920 +**Example:** AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 928 928 929 929 930 930 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** ... ... @@ -962,7 +962,7 @@ 962 962 ==== 3.4.2.11 Trigger – Set minimum interval ==== 963 963 964 964 965 -Set sAV and AC trigger minimum interval.Devicewon't response to the second trigger within this set time after the first trigger.958 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 966 966 967 967 * (% style="color:#037691" %)**AT Command**(%%): (% style="color:blue" %)**AT+ATDC=5 ** ~/~/ (%%)Device won't response the second trigger within 5 minute after the first trigger. 968 968 ... ... @@ -1110,7 +1110,7 @@ 1110 1110 ))) 1111 1111 1112 1112 ((( 1113 -00: Close d, 01: Open , 11: No action1106 +00: Close , 01: Open , 11: No action 1114 1114 1115 1115 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:320px" %) 1116 1116 |(% style="background-color:#4f81bd; color:white" %)**Downlink Code**|(% style="background-color:#4f81bd; color:white" %)**RO1**|(% style="background-color:#4f81bd; color:white" %)**RO2** ... ... @@ -1232,7 +1232,7 @@ 1232 1232 1233 1233 1234 1234 1235 -==== 3.4.2.19 Counting ~-~- Change counting mode tosave time ====1228 +==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1236 1236 1237 1237 1238 1238 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1418,26 +1418,26 @@ 1418 1418 [[image:thingseye-io-step-6.png||height="625" width="1000"]] 1419 1419 1420 1420 1421 -== 3.6 Interface Detail s==1414 +== 3.6 Interface Detail == 1422 1422 1423 1423 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === 1424 1424 1425 1425 1426 -Support NPN -type sensor1419 +Support NPN Type sensor 1427 1427 1428 1428 [[image:1653356991268-289.png]] 1429 1429 1430 1430 1431 -=== 3.6.2 Digital Input Port s: DI1/DI2 ( For LT-22222-L) ===1424 +=== 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1432 1432 1433 1433 1434 1434 ((( 1435 -The DI port softheLT-22222-L can support **NPN**,**PNP**,or **drycontact** output sensors.1428 +The DI port of LT-22222-L can support **NPN** or **PNP** or **Dry Contact** output sensor. 1436 1436 ))) 1437 1437 1438 1438 ((( 1439 1439 ((( 1440 - The part of the internal circuitof the LT-22222-Lshownbelowincludesthe NEC2501 photocoupler.Theactive current from NEC2501 pin 1 to pin 2 is 1A,withamaximumallowablecurrentof50flowsfromNEC2501 pin,the DI becomesactiveHIGHandtheDI LED status changes.1433 +Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA). (% class="mark" %)When there is active current pass NEC2501 pin1 to pin2. The DI will be active high and DI LED status will change. 1441 1441 1442 1442 1443 1443 ))) ... ... @@ -1447,7 +1447,7 @@ 1447 1447 1448 1448 ((( 1449 1449 ((( 1450 - (% style="color:#000000; font-family:Arial,sans-serif;font-size:11pt; font-style:normal; font-variant-alternates:normal; font-variant-east-asian:normal; font-variant-ligatures:normal; font-variant-numeric:normal;font-variant-position:normal; font-weight:400; text-decoration:none;white-space:pre-wrap" %)When connectinga device to the DI port, both DI1+ and DI1- must be connected.1443 +When use need to connect a device to the DI port, both DI1+ and DI1- must be connected. 1451 1451 ))) 1452 1452 ))) 1453 1453 ... ... @@ -1456,22 +1456,22 @@ 1456 1456 ))) 1457 1457 1458 1458 ((( 1459 -(% style="color: #0000ff" %)**Exampleingto alow-active sensor.1452 +(% style="color:blue" %)**Example1**(%%): Connect to a Low active sensor. 1460 1460 ))) 1461 1461 1462 1462 ((( 1463 -This type of sensor output sa low(GND)signal when active.1456 +This type of sensor will output a low signal GND when active. 1464 1464 ))) 1465 1465 1466 1466 * ((( 1467 -Connect thesensor's output to DI1-1460 +Connect sensor's output to DI1- 1468 1468 ))) 1469 1469 * ((( 1470 -Connect thesensor's VCC to DI1+.1463 +Connect sensor's VCC to DI1+. 1471 1471 ))) 1472 1472 1473 1473 ((( 1474 - Whenthesensorisactive, the current between NEC2501 pinwill be:1467 +So when sensor active, the current between NEC2501 pin1 and pin2 is: 1475 1475 ))) 1476 1476 1477 1477 ((( ... ... @@ -1479,7 +1479,7 @@ 1479 1479 ))) 1480 1480 1481 1481 ((( 1482 - For example, if** DI1+ **= **12V**, theresulting current is[[image:1653968155772-850.png||height="23" width="19"]]= 12mA.Therefore, the LT-22222-L will be able to detect this active signal.1475 +If** DI1+ **= **12v**, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal. 1483 1483 ))) 1484 1484 1485 1485 ((( ... ... @@ -1487,22 +1487,22 @@ 1487 1487 ))) 1488 1488 1489 1489 ((( 1490 -(% style="color: #0000ff" %)**Exampleingto ahigh-active sensor.1483 +(% style="color:blue" %)**Example2**(%%): Connect to a High active sensor. 1491 1491 ))) 1492 1492 1493 1493 ((( 1494 -This type of sensor output sa high signal (e.g.,24V) when active.1487 +This type of sensor will output a high signal (example 24v) when active. 1495 1495 ))) 1496 1496 1497 1497 * ((( 1498 -Connect thesensor's output to DI1+1491 +Connect sensor's output to DI1+ 1499 1499 ))) 1500 1500 * ((( 1501 -Connect thesensor's GND DI1-.1494 +Connect sensor's GND DI1-. 1502 1502 ))) 1503 1503 1504 1504 ((( 1505 - Whenthesensorisactive, the current between NEC2501 pin1 and pin2will be:1498 +So when sensor active, the current between NEC2501 pin1 and pin2 is: 1506 1506 ))) 1507 1507 1508 1508 ((( ... ... @@ -1510,7 +1510,7 @@ 1510 1510 ))) 1511 1511 1512 1512 ((( 1513 -If **DI1+ = 24 V**, theresulting current[[image:1653968155772-850.png||height="23" width="19"]]is24mA,Therefore,the LT-22222-L will detect this high-active signal.1506 +If **DI1+ = 24v**, the[[image:1653968155772-850.png||height="23" width="19"]] 24mA , So the LT-22222-L will be able to detect this high active signal. 1514 1514 ))) 1515 1515 1516 1516 ((( ... ... @@ -1518,22 +1518,22 @@ 1518 1518 ))) 1519 1519 1520 1520 ((( 1521 -(% style="color: #0000ff" %)**Exampleingto a 220Vhigh-active sensor.1514 +(% style="color:blue" %)**Example3**(%%): Connect to a 220v high active sensor. 1522 1522 ))) 1523 1523 1524 1524 ((( 1525 -Assume that you want to monitor an active signal higher than 220Vwithoutdamagingthe photocoupler1518 +Assume user want to monitor an active signal higher than 220v, to make sure not burn the photocoupler 1526 1526 ))) 1527 1527 1528 1528 * ((( 1529 -Connect thesensor's output to DI1+ with a 50K resistorin series.1522 +Connect sensor's output to DI1+ with a serial 50K resistor 1530 1530 ))) 1531 1531 * ((( 1532 -Connect thesensor's GND DI1-.1525 +Connect sensor's GND DI1-. 1533 1533 ))) 1534 1534 1535 1535 ((( 1536 - Whenthesensorisactive, the current between NEC2501 pin1 and pin2will be:1529 +So when sensor active, the current between NEC2501 pin1 and pin2 is: 1537 1537 ))) 1538 1538 1539 1539 ((( ... ... @@ -1541,37 +1541,37 @@ 1541 1541 ))) 1542 1542 1543 1543 ((( 1544 -If thesensor output is 220V, then[[image:1653968155772-850.png||height="23" width="19"]](% id="cke_bm_243359S" style="display:none"wfd-invisible="true"%)[[image:image-20220524095628-8.png]](%%) = DI1+ / 51K = 4.3mA.Therefore, the LT-22222-L will be able tosafelydetect this high-active signal.1537 +If sensor output is 220v, the [[image:1653968155772-850.png||height="23" width="19"]](% id="cke_bm_243359S" style="display:none" %)[[image:image-20220524095628-8.png]](%%) = DI1+ / 51K. = 4.3mA , So the LT-22222-L will be able to detect this high active signal safely. 1545 1545 ))) 1546 1546 1547 1547 1548 -(% style="color:blue" %)**Example4**(%%): Connect ingto Dry Contact sensor1541 +(% style="color:blue" %)**Example4**(%%): Connect to Dry Contact sensor 1549 1549 1550 -From the DI port circuitabove,youcan see that activatingthe photocouplerrequiresa voltage difference betweentheDI+ and DI- ports.However,the Dry Contact sensor is a passive componentandcannot provide this voltage difference.1543 +From above DI ports circuit, we can see that active the photocoupler will need to have a voltage difference between DI+ and DI- port. While the Dry Contact sensor is a passive component which can't provide this voltage difference. 1551 1551 1552 -To detect a Dry Contact, youcansupplya power source to one pin of the Dry Contact. Below is a reference circuitdiagram.1545 +To detect a Dry Contact, we can provide a power source to one pin of the Dry Contact. Below is a reference connection. 1553 1553 1554 1554 [[image:image-20230616235145-1.png]] 1555 1555 1556 -(% style="color:blue" %)**Example5**(%%): Connect ingtoanOpen Collector1549 +(% style="color:blue" %)**Example5**(%%): Connect to Open Colleactor 1557 1557 1558 1558 [[image:image-20240219115718-1.png]] 1559 1559 1560 1560 1561 -=== 3.6.3 Digital Output Port s: DO1/DO2 /DO3 ===1554 +=== 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1562 1562 1563 1563 1564 -(% style="color:blue" %)**NPN output**(%%): GND or Float. The maximumvoltagethatcanbeappliedtotheoutput pin is 36V.1557 +(% style="color:blue" %)**NPN output**(%%): GND or Float. Max voltage can apply to output pin is 36v. 1565 1565 1566 -(% style="color:red" %)**Note: TheDO pinswillfloat whenthedevice is poweredoff.**1559 +(% style="color:red" %)**Note: DO pins go to float when device is power off.** 1567 1567 1568 1568 [[image:1653357531600-905.png]] 1569 1569 1570 1570 1571 -=== 3.6.4 Analog Input Interface s===1564 +=== 3.6.4 Analog Input Interface === 1572 1572 1573 1573 1574 -The analog input interface is s hownbelow. The LT-22222-Lwill measure the IN2 voltage to calculate the current passingthrough theload. The formula is:1567 +The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: 1575 1575 1576 1576 1577 1577 (% style="color:blue" %)**AC2 = (IN2 voltage )/12** ... ... @@ -1578,14 +1578,14 @@ 1578 1578 1579 1579 [[image:1653357592296-182.png]] 1580 1580 1581 -Example :Connectinga 4~~20mA sensor1574 +Example to connect a 4~~20mA sensor 1582 1582 1583 -We will use the wind speed sensor as an example for reference only.1576 +We take the wind speed sensor as an example for reference only. 1584 1584 1585 1585 1586 1586 (% style="color:blue" %)**Specifications of the wind speed sensor:** 1587 1587 1588 -(% style="color:red" %)**Red: 12~~24 V**1581 +(% style="color:red" %)**Red: 12~~24v** 1589 1589 1590 1590 (% style="color:#ffc000" %)**Yellow: 4~~20mA** 1591 1591 ... ... @@ -1598,7 +1598,7 @@ 1598 1598 [[image:1653357648330-671.png||height="155" width="733"]] 1599 1599 1600 1600 1601 -Example :Connectingto a regulated power supply to measure voltage1594 +Example connected to a regulated power supply to measure voltage 1602 1602 1603 1603 [[image:image-20230608101532-1.png||height="606" width="447"]] 1604 1604 ... ... @@ -1607,7 +1607,7 @@ 1607 1607 [[image:image-20230608101722-3.png||height="102" width="1139"]] 1608 1608 1609 1609 1610 -(% style="color:blue; font-weight:bold" %)**Specifications of the regulated power supply**(% style="color:blue" %)**:**1603 +(% style="color:blue; font-weight:bold" %)**Specifications of the regulated power**(%%) (% style="color:blue" %)**:** 1611 1611 1612 1612 (% style="color:red" %)**Red: 12~~24v** 1613 1613 ... ... @@ -1618,9 +1618,9 @@ 1618 1618 1619 1619 1620 1620 ((( 1621 -The LT -22222-Lhas two relay interfaces,RO1andRO2,eachusingtwo pins of the screw terminal(ROx-1 and ROx-2 where x istheportnumber, 1 or 2). Youcan connectadevice'spowerline in serieswithone ofthe relay interfaces (e.g.,RO1-1 and RO1-2screw terminals). See theexamplebelow:1614 +The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device's Power Line to in serial of RO1_1 and RO_2. Such as below: 1622 1622 1623 -**Note**: TheROxpinswillbe intheOpenstatewhentheLT-22222-Lis poweredoff.1616 +**Note**: RO pins go to Open(NO) when device is power off. 1624 1624 ))) 1625 1625 1626 1626 [[image:image-20220524100215-9.png]] ... ... @@ -1648,25 +1648,25 @@ 1648 1648 Transmit a LoRa packet: TX blinks once 1649 1649 ))) 1650 1650 ))) 1651 -|**RX**|RX blinks once when receiv inga packet.1652 -|**DO1**|For LT-22222-L: ON when DO1 is low, O FFwhen DO1 is high1653 -|**DO2**|For LT-22222-L: ON when DO2 is low, O FFwhen DO2 is high1644 +|**RX**|RX blinks once when receive a packet. 1645 +|**DO1**|For LT-22222-L: ON when DO1 is low, LOW when DO1 is high 1646 +|**DO2**|For LT-22222-L: ON when DO2 is low, LOW when DO2 is high 1654 1654 |**DI1**|((( 1655 -For LT-22222-L: ON when DI1 is high, O FFwhen DI1 is low1648 +For LT-22222-L: ON when DI1 is high, LOW when DI1 is low 1656 1656 ))) 1657 1657 |**DI2**|((( 1658 -For LT-22222-L: ON when DI2 is high, O FFwhen DI2 is low1651 +For LT-22222-L: ON when DI2 is high, LOW when DI2 is low 1659 1659 ))) 1660 -|**RO1**|For LT-22222-L: ON when RO1 is closed, O FFwhen RO1 is open1661 -|**RO2**|For LT-22222-L: ON when RO2 is closed, O FFwhen RO2 is open1653 +|**RO1**|For LT-22222-L: ON when RO1 is closed, LOW when RO1 is open 1654 +|**RO2**|For LT-22222-L: ON when RO2 is closed, LOW when RO2 is open 1662 1662 1663 -= 4. Us ingAT Command =1656 += 4. Use AT Command = 1664 1664 1665 -== 4.1 Connecting theLT-22222-Ltocomputer==1658 +== 4.1 Access AT Command == 1666 1666 1667 1667 1668 1668 ((( 1669 - TheLT-22222-Lsupportsprogramming usingAT Commands.Youcan use a USB-to-TTL adapteralongwitha3.5mm Program Cable to connect theLT-22222-Ltoacomputer, asshownbelow.1662 +LT supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to LT for using AT command, as below. 1670 1670 ))) 1671 1671 1672 1672 [[image:1653358238933-385.png]] ... ... @@ -1673,7 +1673,7 @@ 1673 1673 1674 1674 1675 1675 ((( 1676 - OnthePC,the user needs to setthe(% style="color:#4f81bd" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT)to abaud rate of(% style="color:green" %)**9600**(%%) to access to access serial consoleof LT-22222-L. The AT commands are disabledby default,andapassword (default:(% style="color:green" %)**123456**)(%%)mustbe entered to active them,as shown below:1669 +In PC, User needs to set (% style="color:#4f81bd" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for LT. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**)(%%) to active it. As shown below: 1677 1677 ))) 1678 1678 1679 1679 [[image:1653358355238-883.png]] ... ... @@ -1680,12 +1680,10 @@ 1680 1680 1681 1681 1682 1682 ((( 1683 - You can find more detailsinthe1676 +More detail AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 1684 1684 ))) 1685 1685 1686 1686 ((( 1687 -The following table lists all the AT commands related to the LT-22222-L, except for those used for switching between modes. 1688 - 1689 1689 AT+<CMD>? : Help on <CMD> 1690 1690 ))) 1691 1691 ... ... @@ -2010,10 +2010,10 @@ 2010 2010 2011 2011 = 5. Case Study = 2012 2012 2013 -== 5.1 Counting how many objects pass throughthe flow Line ==2004 +== 5.1 Counting how many objects pass in Flow Line == 2014 2014 2015 2015 2016 -Reference Link: [[How to set up to setupcountingfor objects passingthrough theflow line>>How to set up to count objects pass in flow line]]?2007 +Reference Link: [[How to set up to count objects pass in flow line>>How to set up to count objects pass in flow line]]? 2017 2017 2018 2018 2019 2019 = 6. FAQ = ... ... @@ -2021,26 +2021,26 @@ 2021 2021 == 6.1 How to upgrade the image? == 2022 2022 2023 2023 2024 -The LT -22222-LI/OController is shipped with a 3.5mm cable,whichis used to uploadanimage to LTin orderto:2015 +The LT LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to LT to: 2025 2025 2026 -* Support new features .2027 -* F ixbugs.2017 +* Support new features 2018 +* For bug fix 2028 2028 * Change LoRaWAN bands. 2029 2029 2030 -Below is the hardware connectionsetupfor uploadingan image to the LT:2021 +Below shows the hardware connection for how to upload an image to the LT: 2031 2031 2032 2032 [[image:1653359603330-121.png]] 2033 2033 2034 2034 2035 2035 ((( 2036 -(% style="color: #0000ff" %)**Stepthe F[[lashLoader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].2037 -(% style="color: #0000ff" %)**Step2038 -(% style="color: #0000ff" %)**Stepthe FlashLoaderandchoose the correct COM port to update.2027 +(% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 2028 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AACrbrDN0AqLHbBat0ViWx5Da/LT-22222-L/Firmware?dl=0&subfolder_nav_tracking=1]]. 2029 +(% style="color:blue" %)**Step3**(%%)**:** Open flashloader; choose the correct COM port to update. 2039 2039 2040 2040 2041 2041 ((( 2042 2042 (% style="color:blue" %)**For LT-22222-L**(%%): 2043 -Hold down the PRO button ,then momentarily press the RST reset button.The (% style="color:red" %)**DO1LED**(%%)the(% style="color:red" %)**DO1 LED**(%%) isON, itindicates that the device is in download mode.2034 +Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode. 2044 2044 ))) 2045 2045 2046 2046 ... ... @@ -2055,7 +2055,7 @@ 2055 2055 [[image:image-20220524104033-15.png]] 2056 2056 2057 2057 2058 -(% style="color:red" %)**Note**(%%): I fyou havelost the programmingcable,youcan make one from a 3.5mm cable. The pin mapping isas follows:2049 +(% style="color:red" %)**Notice**(%%): In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 2059 2059 2060 2060 [[image:1653360054704-518.png||height="186" width="745"]] 2061 2061 ... ... @@ -2069,13 +2069,13 @@ 2069 2069 ))) 2070 2070 2071 2071 ((( 2072 - Youcan follow the introductionson[[how to upgrade image>>||anchor="H5.1Howtoupgradetheimage3F"]]. When downloading, selectthe required image file.2063 +User can follow the introduction for [[how to upgrade image>>||anchor="H5.1Howtoupgradetheimage3F"]]. When download the images, choose the required image file for download. 2073 2073 ))) 2074 2074 2075 2075 ((( 2076 2076 2077 2077 2078 -== 6.3 How to set up LT to work with aSingle Channel Gateway,such as LG01/LG02? ==2069 +== 6.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 2079 2079 2080 2080 2081 2081 ))) ... ... @@ -2082,13 +2082,13 @@ 2082 2082 2083 2083 ((( 2084 2084 ((( 2085 -In this case, you need to settheLT-33222-L to work in ABP modeandtransmiton only one frequency.2076 +In this case, users need to set LT-33222-L to work in ABP mode & transmit in only one frequency. 2086 2086 ))) 2087 2087 ))) 2088 2088 2089 2089 ((( 2090 2090 ((( 2091 -Assume youhave anLG02 workingon the frequency 868400000.Belowarethe steps.2082 +Assume we have a LG02 working in the frequency 868400000 now , below is the step. 2092 2092 2093 2093 2094 2094 ))) ... ... @@ -2095,7 +2095,7 @@ 2095 2095 ))) 2096 2096 2097 2097 ((( 2098 -(% style="color: #0000ff" %)**SteptoTheThings Stack SANDBOX,create an ABP device in the application,and input theNetworkSession key (NwkSKey),App session key (AppSKey)of the device.2089 +(% style="color:blue" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device. 2099 2099 2100 2100 2101 2101 ))) ... ... @@ -2152,7 +2152,7 @@ 2152 2152 Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/]] 2153 2153 2154 2154 2155 -== 6.5 Can I see thecounting event in Serial? ==2146 +== 6.5 Can I see counting event in Serial? == 2156 2156 2157 2157 2158 2158 ((( ... ... @@ -2159,10 +2159,10 @@ 2159 2159 User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 2160 2160 2161 2161 2162 -== 6.6 Can Iuse point-to-point communicationwithLT-22222-L? ==2153 +== 6.6 Can i use point to point communication for LT-22222-L? == 2163 2163 2164 2164 2165 -Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] .this is [[firmware>>https://github.com/dragino/LT-22222-L/releases]].2156 +Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https://github.com/dragino/LT-22222-L/releases]]. 2166 2166 2167 2167 2168 2168 )))
- lt-22222-l-manually-p1.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 -30 6.6KB1 +310.3 KB - Content
- lt-22222-l-manually-p2.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 - 279.1 KB1 +301.5 KB - Content