... ... @@ -1420,7 +1420,7 @@
1420 1420  [[image:thingseye-io-step-6.png||height="625" width="1000"]]
1421 1421  
1422 1422  
1423 -== 3.6 Interface Details ==
1423 +== 3.6 Interface Detail ==
1424 1424  
1425 1425  === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) ===
1426 1426  
... ... @@ -1430,16 +1430,16 @@
1430 1430  [[image:1653356991268-289.png]]
1431 1431  
1432 1432  
1433 -=== 3.6.2 Digital Input Ports: DI1/DI2 ( For LT-22222-L) ===
1433 +=== 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) ===
1434 1434  
1435 1435  
1436 1436  (((
1437 -The DI ports of the LT-22222-L can support **NPN**, **PNP**, or **dry contact** output sensors.
1437 +The DI port of LT-22222-L can support **NPN** or **PNP** or **Dry Contact** output sensor.
1438 1438  )))
1439 1439  
1440 1440  (((
1441 1441  (((
1442 -The part of the internal circuit of the LT-22222-L shown below includes the NEC2501 photocoupler. The active current from NEC2501 pin 1 to pin 2 is 1 mA, with a maximum allowable current of 50 mA. When active current flows from NEC2501 pin 1 to pin 2, the DI becomes active HIGH, and the DI LED status changes.
1442 +Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA). (% class="mark" %)When there is active current pass NEC2501 pin1 to pin2. The DI will be active high and DI LED status will change.
1443 1443  
1444 1444  
1445 1445  )))
... ... @@ -1449,7 +1449,7 @@
1449 1449  
1450 1450  (((
1451 1451  (((
1452 -(% style="color:#000000; font-family:Arial,sans-serif; font-size:11pt; font-style:normal; font-variant-alternates:normal; font-variant-east-asian:normal; font-variant-ligatures:normal; font-variant-numeric:normal; font-variant-position:normal; font-weight:400; text-decoration:none; white-space:pre-wrap" %)When connecting a device to the DI port, both DI1+ and DI1- must be connected.
1452 +When use need to connect a device to the DI port, both DI1+ and DI1- must be connected.
1453 1453  )))
1454 1454  )))
1455 1455  
... ... @@ -1458,22 +1458,22 @@
1458 1458  )))
1459 1459  
1460 1460  (((
1461 -(% style="color:blue" %)**Example1**(%%): Connecting to a low-active sensor.
1461 +(% style="color:blue" %)**Example1**(%%): Connect to a Low active sensor.
1462 1462  )))
1463 1463  
1464 1464  (((
1465 -This type of sensors outputs a low (GND) signal when active.
1465 +This type of sensor will output a low signal GND when active.
1466 1466  )))
1467 1467  
1468 1468  * (((
1469 -Connect the sensor's output to DI1-
1469 +Connect sensor's output to DI1-
1470 1470  )))
1471 1471  * (((
1472 -Connect the sensor's VCC to DI1+.
1472 +Connect sensor's VCC to DI1+.
1473 1473  )))
1474 1474  
1475 1475  (((
1476 -When the sensor is active, the current between NEC2501 pin 1 and pin 2 will be
1476 +So when sensor active, the current between NEC2501 pin1 and pin2 is
1477 1477  )))
1478 1478  
1479 1479  (((
... ... @@ -1481,7 +1481,7 @@
1481 1481  )))
1482 1482  
1483 1483  (((
1484 -For example, if** DI1+ **= **12V**, the resulting current is [[image:1653968155772-850.png||height="23" width="19"]]= 12mA. Therefore, the LT-22222-L will be able to detect this active signal.
1484 +If** DI1+ **= **12v**, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal.
1485 1485  )))
1486 1486  
1487 1487  (((
... ... @@ -1489,22 +1489,22 @@
1489 1489  )))
1490 1490  
1491 1491  (((
1492 -(% style="color:blue" %)**Example2**(%%): Connecting to a high-active sensor.
1492 +(% style="color:blue" %)**Example2**(%%): Connect to a High active sensor.
1493 1493  )))
1494 1494  
1495 1495  (((
1496 -This type of sensors outputs a high signal (e.g., 24V) when active.
1496 +This type of sensor will output a high signal (example 24v) when active.
1497 1497  )))
1498 1498  
1499 1499  * (((
1500 -Connect the sensor's output to DI1+
1500 +Connect sensor's output to DI1+
1501 1501  )))
1502 1502  * (((
1503 -Connect the sensor's GND DI1-.
1503 +Connect sensor's GND DI1-.
1504 1504  )))
1505 1505  
1506 1506  (((
1507 -When the sensor is active, the current between NEC2501 pin1 and pin2 will be:
1507 +So when sensor active, the current between NEC2501 pin1 and pin2 is:
1508 1508  )))
1509 1509  
1510 1510  (((
... ... @@ -1512,7 +1512,7 @@
1512 1512  )))
1513 1513  
1514 1514  (((
1515 -If **DI1+ = 24V**, the resulting current[[image:1653968155772-850.png||height="23" width="19"]] 24mA , Therefore, the LT-22222-L will detect this high-active signal.
1515 +If **DI1+ = 24v**, the[[image:1653968155772-850.png||height="23" width="19"]] 24mA , So the LT-22222-L will be able to detect this high active signal.
1516 1516  )))
1517 1517  
1518 1518  (((
... ... @@ -1520,22 +1520,22 @@
1520 1520  )))
1521 1521  
1522 1522  (((
1523 -(% style="color:blue" %)**Example3**(%%): Connecting to a 220V high-active sensor.
1523 +(% style="color:blue" %)**Example3**(%%): Connect to a 220v high active sensor.
1524 1524  )))
1525 1525  
1526 1526  (((
1527 -Assume that you want to monitor an active signal higher than 220V without damaging the photocoupler  
1527 +Assume user want to monitor an active signal higher than 220v, to make sure not burn the photocoupler  
1528 1528  )))
1529 1529  
1530 1530  * (((
1531 -Connect the sensor's output to DI1+ with a 50K resistor in series.
1531 +Connect sensor's output to DI1+ with a serial 50K resistor
1532 1532  )))
1533 1533  * (((
1534 -Connect the sensor's GND DI1-.
1534 +Connect sensor's GND DI1-.
1535 1535  )))
1536 1536  
1537 1537  (((
1538 -When the sensor is active, the current between NEC2501 pin1 and pin2 will be:
1538 +So when sensor active, the current between NEC2501 pin1 and pin2 is:
1539 1539  )))
1540 1540  
1541 1541  (((
... ... @@ -1543,37 +1543,37 @@
1543 1543  )))
1544 1544  
1545 1545  (((
1546 -If the sensor output is 220V, the[[image:1653968155772-850.png||height="23" width="19"]](% id="cke_bm_243359S" style="display:none" %)[[image:image-20220524095628-8.png]](%%) = DI1+ / 51K.  = 4.3mA. Therefore, the LT-22222-L will be able to safely detect this high-active signal.
1546 +If sensor output is 220v, the [[image:1653968155772-850.png||height="23" width="19"]](% id="cke_bm_243359S" style="display:none" %)[[image:image-20220524095628-8.png]](%%) = DI1+ / 51K.  = 4.3mA , So the LT-22222-L will be able to detect this high active signal safely.
1547 1547  )))
1548 1548  
1549 1549  
1550 -(% style="color:blue" %)**Example4**(%%): Connecting to Dry Contact sensor
1550 +(% style="color:blue" %)**Example4**(%%): Connect to Dry Contact sensor
1551 1551  
1552 -From DI port circuit above, you can see that activating the photocoupler requires a voltage difference between the DI+ and DI- ports. However, the Dry Contact sensor is a passive component and cannot provide this voltage difference.
1552 +From above DI ports circuit, we can see that active the photocoupler will need to have a voltage difference between DI+ and DI- port. While the Dry Contact sensor is a passive component which can't provide this voltage difference.
1553 1553  
1554 -To detect a Dry Contact, you can supply a power source to one pin of the Dry Contact. Below is a reference circuit diagram.
1554 +To detect a Dry Contact, we can provide a power source to one pin of the Dry Contact. Below is a reference connection.
1555 1555  
1556 1556  [[image:image-20230616235145-1.png]]
1557 1557  
1558 -(% style="color:blue" %)**Example5**(%%): Connecting to an Open Collector
1558 +(% style="color:blue" %)**Example5**(%%): Connect to Open Colleactor
1559 1559  
1560 1560  [[image:image-20240219115718-1.png]]
1561 1561  
1562 1562  
1563 -=== 3.6.3 Digital Output Ports: DO1/DO2 /DO3 ===
1563 +=== 3.6.3 Digital Output Port: DO1/DO2 /DO3 ===
1564 1564  
1565 1565  
1566 -(% style="color:blue" %)**NPN output**(%%): GND or Float. The maximum voltage that can be applied to the output pin is 36V.
1566 +(% style="color:blue" %)**NPN output**(%%): GND or Float. Max voltage can apply to output pin is 36v.
1567 1567  
1568 -(% style="color:red" %)**Note: The DO pins will float when device is powered off.**
1568 +(% style="color:red" %)**Note: DO pins go to float when device is power off.**
1569 1569  
1570 1570  [[image:1653357531600-905.png]]
1571 1571  
1572 1572  
1573 -=== 3.6.4 Analog Input Interfaces ===
1573 +=== 3.6.4 Analog Input Interface ===
1574 1574  
1575 1575  
1576 -The analog input interface is shown below. The LT-22222-L will measure the IN2 voltage to calculate the current passing through the load. The formula is:
1576 +The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is:
1577 1577  
1578 1578  
1579 1579  (% style="color:blue" %)**AC2 = (IN2 voltage )/12**
... ... @@ -1580,14 +1580,14 @@
1580 1580  
1581 1581  [[image:1653357592296-182.png]]
1582 1582  
1583 -Example: Connecting a 4~~20mA sensor
1583 +Example to connect a 4~~20mA sensor
1584 1584  
1585 -We will use the wind speed sensor as an example for reference only.
1585 +We take the wind speed sensor as an example for reference only.
1586 1586  
1587 1587  
1588 1588  (% style="color:blue" %)**Specifications of the wind speed sensor:**
1589 1589  
1590 -(% style="color:red" %)**Red:  12~~24V**
1590 +(% style="color:red" %)**Red:  12~~24v**
1591 1591  
1592 1592  (% style="color:#ffc000" %)**Yellow:  4~~20mA**
1593 1593  
... ... @@ -1600,7 +1600,7 @@
1600 1600  [[image:1653357648330-671.png||height="155" width="733"]]
1601 1601  
1602 1602  
1603 -Example: Connecting to a regulated power supply to measure voltage
1603 +Example connected to a regulated power supply to measure voltage
1604 1604  
1605 1605  [[image:image-20230608101532-1.png||height="606" width="447"]]
1606 1606  
... ... @@ -1609,7 +1609,7 @@
1609 1609  [[image:image-20230608101722-3.png||height="102" width="1139"]]
1610 1610  
1611 1611  
1612 -(% style="color:blue; font-weight:bold" %)**Specifications of the regulated power supply**(% style="color:blue" %)**:**
1612 +(% style="color:blue; font-weight:bold" %)**Specifications of the regulated power**(%%) (% style="color:blue" %)**:**
1613 1613  
1614 1614  (% style="color:red" %)**Red:  12~~24v**
1615 1615  
... ... @@ -1620,9 +1620,9 @@
1620 1620  
1621 1621  
1622 1622  (((
1623 -The LT-22222-L has two relay interfaces, RO1 and RO2, each using two pins of the screw terminal (ROx-1 and ROx-2 where x is the port number, 1 or 2). You can connect a device's power line in series with one of the relay interfaces (e.g., RO1-1 and RO1-2 screw terminals). See the example below:
1623 +The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device's Power Line to in serial of RO1_1 and RO_2. Such as below:
1624 1624  
1625 -**Note**: The ROx pins will be in the Open (NO) state when the LT-22222-L is powered off.
1625 +**Note**: RO pins go to Open(NO) when device is power off.
1626 1626  )))
1627 1627  
1628 1628  [[image:image-20220524100215-9.png]]
... ... @@ -1662,13 +1662,13 @@
1662 1662  |**RO1**|For LT-22222-L: ON when RO1 is closed, LOW when RO1 is open
1663 1663  |**RO2**|For LT-22222-L: ON when RO2 is closed, LOW when RO2 is open
1664 1664  
1665 -= 4. Using AT Command =
1665 += 4. Use AT Command =
1666 1666  
1667 -== 4.1 Connecting the LT-22222-L to a computer ==
1667 +== 4.1 Access AT Command ==
1668 1668  
1669 1669  
1670 1670  (((
1671 -The LT-22222-L supports programming using AT Commands. You can use a USB-to-TTL adapter along with a 3.5mm Program Cable to connect the LT-22222-L to a computer, as shown below.
1671 +LT supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to LT for using AT command, as below.
1672 1672  )))
1673 1673  
1674 1674  [[image:1653358238933-385.png]]
... ... @@ -1675,7 +1675,7 @@
1675 1675  
1676 1676  
1677 1677  (((
1678 -On the PC, the user needs to set the (% style="color:#4f81bd" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) to a baud rate o(% style="color:green" %)**9600**(%%) to access to access serial console of LT-22222-L. The AT commands are disabled by default, and a password (default:(% style="color:green" %)**123456**)(%%) must be entered to active them, as shown below:
1678 +In PC, User needs to set (% style="color:#4f81bd" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for LT. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**)(%%) to active it. As shown below:
1679 1679  )))
1680 1680  
1681 1681  [[image:1653358355238-883.png]]
... ... @@ -1682,12 +1682,10 @@
1682 1682  
1683 1683  
1684 1684  (((
1685 -You can find more details in the [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1685 +More detail AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
1686 1686  )))
1687 1687  
1688 1688  (((
1689 -The following table lists all the AT commands related to the LT-22222-L, except for those used for switching between modes.
1690 -
1691 1691  AT+<CMD>?        : Help on <CMD>
1692 1692  )))
1693 1693  