... ... @@ -68,6 +68,7 @@
68 68  ** 20dB Transmit: 34mA@12v
69 69  * Operating Temperature: -40 ~~ 85 Degree, No Dew
70 70  
71 +
71 71  (% style="color:#037691" %)**Interface for Model: LT22222-L:**
72 72  
73 73  * 2 x Digital dual direction Input (Detect High/Low signal, Max: 50v, or 220v with optional external resistor)
... ... @@ -77,6 +77,7 @@
77 77  * 2 x 0~~30V Analog Input (res:0.01v)
78 78  * Power Input 7~~ 24V DC. 
79 79  
81 +
80 80  (% style="color:#037691" %)**LoRa Spec:**
81 81  
82 82  * Frequency Range:
... ... @@ -1569,6 +1569,9 @@
1569 1569  (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
1570 1570  |(% style="background-color:#4f81bd; color:white; width:50px" %)**LEDs**|(% style="background-color:#4f81bd; color:white; width:460px" %)**Feature**
1571 1571  |**PWR**|Always on if there is power
1574 +|**SYS**|(((
1575 +After device is powered on, the SYS will **fast blink in GREEN** for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be **on GREEN for 5 seconds. **SYS will **blink Blue** on every upload and **blink Green** once receive a downlink message.
1576 +)))
1572 1572  |**TX**|(((
1573 1573  (((
1574 1574  Device boot: TX blinks 5 times.
... ... @@ -1583,16 +1583,20 @@
1583 1583  )))
1584 1584  )))
1585 1585  |**RX**|RX blinks once when receive a packet.
1586 -|**DO1**|For LT-22222-L: ON when DO1 is low, LOW when DO1 is high
1587 -|**DO2**|For LT-22222-L: ON when DO2 is low, LOW when DO2 is high
1588 -|**DI1**|(((
1589 -For LT-22222-L: ON when DI1 is high, LOW when DI1 is low
1591 +|**DO1**|
1592 +|**DO2**|
1593 +|**DO3**|
1594 +|**DI2**|(((
1595 +For LT-22222-L: ON when DI2 is high, LOW when DI2 is low
1590 1590  )))
1591 1591  |**DI2**|(((
1592 -For LT-22222-L: ON when DI2 is high, OFF when DI2 is low
1598 +For LT-22222-L: ON when DI2 is high, LOW when DI2 is low
1593 1593  )))
1594 -|**RO1**|For LT-22222-L: ON when RO1 is closed, LOW when RO1 is open
1595 -|**RO2**|For LT-22222-L: ON when RO2 is closed, LOW when RO2 is open
1600 +|**DI2**|(((
1601 +For LT-22222-L: ON when DI2 is high, LOW when DI2 is low
1602 +)))
1603 +|**RO1**|
1604 +|**RO2**|