Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -LT-22222-L LoRa IO Controller User Manual 1 +LT-22222-L -- LoRa IO Controller User Manual - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -3,6 +3,10 @@ 3 3 4 4 5 5 6 + 7 + 8 + 9 + 6 6 **Table of Contents:** 7 7 8 8 {{toc/}} ... ... @@ -1155,7 +1155,7 @@ 1155 1155 ))) 1156 1156 1157 1157 ((( 1158 -0 1: Close , 00: Open , 11: No action1162 +00: Close , 01: Open , 11: No action 1159 1159 1160 1160 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:320px" %) 1161 1161 |(% style="background-color:#4f81bd; color:white" %)**Downlink Code**|(% style="background-color:#4f81bd; color:white" %)**RO1**|(% style="background-color:#4f81bd; color:white" %)**RO2** ... ... @@ -1586,7 +1586,6 @@ 1586 1586 [[image:image-20240219115718-1.png]] 1587 1587 1588 1588 1589 - 1590 1590 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1591 1591 1592 1592 ... ... @@ -1661,8 +1661,8 @@ 1661 1661 == 3.7 LEDs Indicators == 1662 1662 1663 1663 1664 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:520px" %)1665 -|(% style="background-color:#4f81bd; color:white; width:50px" %)**LEDs**|(% style="background-color:#4f81bd; color:white; width:4 70px" %)**Feature**1667 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 1668 +|(% style="background-color:#4f81bd; color:white; width:50px" %)**LEDs**|(% style="background-color:#4f81bd; color:white; width:460px" %)**Feature** 1666 1666 |**PWR**|Always on if there is power 1667 1667 |**SYS**|((( 1668 1668 After device is powered on, the SYS will **fast blink in GREEN** for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be **on GREEN for 5 seconds. **SYS will **blink Blue** on every upload and **blink Green** once receive a downlink message. ... ... @@ -1705,10 +1705,6 @@ 1705 1705 LT supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to LT for using AT command, as below. 1706 1706 ))) 1707 1707 1708 -((( 1709 - 1710 -))) 1711 - 1712 1712 [[image:1653358238933-385.png]] 1713 1713 1714 1714 ... ... @@ -2339,4 +2339,3 @@ 2339 2339 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2340 2340 * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 2341 2341 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 2342 -