Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -43,7 +43,7 @@ 43 43 **Hardware System:** 44 44 45 45 * STM32L072CZT6 MCU 46 -* SX1276/78 Wireless Chip 46 +* SX1276/78 Wireless Chip 47 47 * Power Consumption: 48 48 ** Idle: 4mA@12v 49 49 ** 20dB Transmit: 34mA@12v ... ... @@ -55,7 +55,7 @@ 55 55 * 2 x Relay Output (5A@250VAC / 30VDC) 56 56 * 2 x 0~~20mA Analog Input (res:0.01mA) 57 57 * 2 x 0~~30V Analog Input (res:0.01v) 58 -* Power Input 7~~ 24V DC. 58 +* Power Input 7~~ 24V DC. 59 59 60 60 **LoRa Spec:** 61 61 ... ... @@ -99,7 +99,7 @@ 99 99 100 100 == 1.5 Hardware Variants == 101 101 102 -(% border="1" style="background-color:#f7faff; width:5 40px" %)102 +(% border="1" style="background-color:#f7faff; width:500px" %) 103 103 |(% style="width:103px" %)**Model**|(% style="width:131px" %)**Photo**|(% style="width:334px" %)**Description** 104 104 |(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)[[image:1653296302983-697.png]]|(% style="width:334px" %)((( 105 105 * 2 x Digital Input (Bi-direction) ... ... @@ -122,7 +122,7 @@ 122 122 123 123 = 3. Operation Mode = 124 124 125 -== 3.1 How it works? 125 +== 3.1 How it works? == 126 126 127 127 The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED** will be on for 1 second. 128 128 ... ... @@ -130,7 +130,7 @@ 130 130 131 131 3.2 Example to join LoRaWAN network 132 132 133 -This chapter shows an example for how to join the TTN LoRaWAN Network. Below is the network structure, we use our LG308 as LoRaWAN gateway here. 133 +This chapter shows an example for how to join the TTN LoRaWAN Network. Below is the network structure, we use our LG308 as LoRaWAN gateway here. 134 134 135 135 [[image:image-20220523172350-1.png||height="266" width="864"]] 136 136 ... ... @@ -153,7 +153,7 @@ 153 153 154 154 Add APP EUI in the application. 155 155 156 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image007.png]][[image:1653297955910-247.png||height="321" width="716"]]156 +[[image:1653297955910-247.png||height="321" width="716"]] 157 157 158 158 Add APP KEY and DEV EUI 159 159 ... ... @@ -165,7 +165,7 @@ 165 165 166 166 [[image:1653298044601-602.png||height="405" width="709"]] 167 167 168 -== [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image009.png]]3.3Uplink Payload ==168 +== 3.3 Uplink Payload == 169 169 170 170 There are five working modes + one interrupt mode on LT for different type application: 171 171 ... ... @@ -182,9 +182,10 @@ 182 182 183 183 [[image:image-20220523174024-3.png]] 184 184 185 +((( 186 +(% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 187 +))) 185 185 186 -**DIDORO** is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 187 - 188 188 [[image:image-20220523174254-4.png]] 189 189 190 190 * RO is for relay. ROx=1 : close,ROx=0 always open. ... ... @@ -191,13 +191,12 @@ 191 191 * DI is for digital input. DIx=1: high or float, DIx=0: low. 192 192 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 193 193 194 -Note: DI3 and DO3 bit are not valid for LT-22222-L 195 +(% style="color:red" %)Note: DI3 and DO3 bit are not valid for LT-22222-L 195 195 197 +For example if payload is: [[image:image-20220523175847-2.png]] 196 196 197 - Forexampleifpayloadis:04 AB 04 AC 13 10 13 00 AA FF 01199 +**The value for the interface is: ** 198 198 199 -The value for the interface is: 200 - 201 201 AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V 202 202 203 203 AVI2 channel voltage is 0x04AC/1000=1.196V ... ... @@ -211,18 +211,11 @@ 211 211 * [1] RO1 relay channel is close and the RO1 LED is ON. 212 212 * [0] RO2 relay channel is open and RO2 LED is OFF; 213 213 214 -LT 33222-L:214 +**LT22222-L:** 215 215 216 -* [1] DI3 channel is high input and DI3 LED is OFF; 217 -* [0] DI2 channel is low input; 218 -* [1] DI1 channel is high input and DI1 LED is OFF; 219 - 220 -LT22222-L: 221 - 222 222 * [1] DI2 channel is high input and DI2 LED is ON; 223 223 * [0] DI1 channel is low input; 224 224 225 - 226 226 * [0] DO3 channel output state 227 227 ** DO3 is float in case no load between DO3 and V+.; 228 228 ** DO3 is high in case there is load between DO3 and V+. ... ... @@ -233,68 +233,61 @@ 233 233 ** DO1 is high in case there is load between DO1 and V+. 234 234 ** DO1 LED is off in both case 235 235 229 +=== 3.3.2 AT+MOD~=2, (Double DI Counting) === 236 236 237 - 238 -1. 239 -11. 240 -111. AT+MOD=2, (Double DI Counting) 241 - 242 -**For LT-33222-L**: this mode the **DI3** is used as a counting pin. Counting on DI3 reflect in COUNT1. 243 - 244 244 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. 245 245 246 - 247 247 Total : 11 bytes payload 248 248 249 -(% border="1" style="background-color:#f7faff" %) 250 -|Size(bytes)|4|4|1|1|1 251 -|Value|COUNT1|COUNT2 |DIDORO*|((( 252 -Reserve 235 +[[image:image-20220523180452-3.png]] 253 253 254 - 255 -)))|MOD 237 +((( 238 +(% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 239 +))) 256 256 241 +[[image:image-20220523180506-4.png]] 257 257 258 -**DIDORO** is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 259 - 260 -(% border="1" style="background-color:#f7faff" %) 261 -|bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 262 -|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 263 - 264 264 * RO is for relay. ROx=1 : close,ROx=0 always open. 265 265 * FIRST: Indicate this is the first packet after join network. 266 266 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 267 267 268 -Note: DO3 bit is not valid for LT-22222-L. 247 +(% style="color:red" %)Note: DO3 bit is not valid for LT-22222-L. 269 269 270 - 271 271 To use counting mode, please run: 272 272 273 -AT+MOD=2 251 +(% class="box infomessage" %) 252 +((( 253 +**AT+MOD=2** 254 +))) 274 274 275 -ATZ 256 +(% class="box infomessage" %) 257 +((( 258 +**ATZ** 259 +))) 276 276 277 - 278 278 AT Commands for counting: 279 279 280 -**For LT33222-L:** 281 - 282 -AT+TRIG1=0,100 (set DI3 port to trigger on low level, valid signal is 100ms) 283 - 284 -AT+TRIG1=1,100 (set DI3 port to trigger on high level, valid signal is 100ms ) 285 - 286 -AT+SETCNT=1,60 (Set COUNT1 value to 60) 287 - 288 - 289 289 **For LT22222-L:** 290 290 291 -AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) 265 +(% class="box infomessage" %) 266 +((( 267 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 268 +))) 292 292 293 -AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 270 +(% class="box infomessage" %) 271 +((( 272 +**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 273 +))) 294 294 295 -AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) 275 +(% class="box infomessage" %) 276 +((( 277 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 278 +))) 296 296 297 -AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) 280 +(% class="box infomessage" %) 281 +((( 282 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 283 +))) 298 298 299 299 300 300 AT+SETCNT=1,60 (Set COUNT1 value to 60) ... ... @@ -310,8 +310,8 @@ 310 310 311 311 312 312 313 -1. 314 -11. 299 +1. 300 +11. 315 315 111. AT+MOD=3, Single DI Counting + 2 x ACI 316 316 317 317 **LT33222-L**: This mode the DI3 is used as a counting pin. ... ... @@ -331,7 +331,6 @@ 331 331 Current 332 332 )))|DIDORO*|Reserve|MOD 333 333 334 - 335 335 **DIDORO** is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 336 336 337 337 (% border="1" style="background-color:#f7faff" %) ... ... @@ -357,8 +357,8 @@ 357 357 358 358 359 359 360 -1. 361 -11. 345 +1. 346 +11. 362 362 111. AT+MOD=4, Single DI Counting + 1 x Voltage Counting 363 363 364 364 **LT33222-L**: This mode the DI3 is used as a counting pin. ... ... @@ -377,7 +377,6 @@ 377 377 378 378 )))|MOD 379 379 380 - 381 381 **DIDORO** is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 382 382 383 383 (% border="1" style="background-color:#f7faff" %) ... ... @@ -413,11 +413,10 @@ 413 413 414 414 415 415 416 -1. 417 -11. 400 +1. 401 +11. 418 418 111. AT+MOD=5, Single DI Counting + 2 x AVI + 1 x ACI 419 419 420 - 421 421 **LT33222-L**: This mode the DI3 is used as a counting pin. 422 422 423 423 **LT22222-L**: This mode the DI1 is used as a counting pin. ... ... @@ -443,8 +443,6 @@ 443 443 444 444 )))|MOD 445 445 446 - 447 - 448 448 **DIDORO** is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 449 449 450 450 (% border="1" style="background-color:#f7faff" %) ... ... @@ -471,11 +471,10 @@ 471 471 472 472 473 473 474 -1. 475 -11. 455 +1. 456 +11. 476 476 111. AT+ADDMOD=6. (Trigger Mode, Optional) 477 477 478 - 479 479 **This mode is an optional mode for trigger purpose. It can run together with other mode.** 480 480 481 481 For example, if user has configured below commands: ... ... @@ -483,13 +483,11 @@ 483 483 * AT+MOD=1 à The normal working mode 484 484 * AT+ADDMOD6=1 à Enable trigger 485 485 486 - 487 487 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 488 488 489 489 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN **unconfirmed** data type 490 490 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN **CONFIRMED data type.** 491 491 492 - 493 493 **AT Command to set Trigger Condition**: 494 494 495 495 **Trigger base on voltage**: ... ... @@ -580,8 +580,6 @@ 580 580 (6) 581 581 ))) 582 582 583 - 584 - 585 585 **TRI FLAG1** is a combination to show if trigger is set for this part. Totally 1byte as below 586 586 587 587 (% border="1" style="background-color:#f7faff" %) ... ... @@ -699,11 +699,10 @@ 699 699 When device got this command, it will send the MOD6 payload. 700 700 701 701 702 -1. 703 -11. 678 +1. 679 +11. 704 704 111. Payload Decoder 705 705 706 - 707 707 **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 708 708 709 709 ... ... @@ -712,7 +712,7 @@ 712 712 713 713 714 714 715 -1. 690 +1. 716 716 11. Configure LT via AT or Downlink 717 717 718 718 User can configure LT I/O Controller via [[AT Commands >>path:#_Using_the_AT]]or LoRaWAN Downlink Commands ... ... @@ -723,20 +723,17 @@ 723 723 724 724 * **Sensor Related Commands**: These commands are special designed for LT-22222-L. User can see these commands below: 725 725 726 - 727 -1. 728 -11. 701 +1. 702 +11. 729 729 111. Common Commands: 730 730 731 - 732 732 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands 733 733 734 734 735 -1. 736 -11. 708 +1. 709 +11. 737 737 111. Sensor related commands: 738 738 739 - 740 740 ==== Set Transmit Interval ==== 741 741 742 742 Set device uplink interval. ... ... @@ -980,7 +980,6 @@ 980 980 |0x00|DO1 set to high 981 981 |0x11|DO1 NO Action 982 982 983 - 984 984 **Fourth Byte**: Control Method and Ports status: 985 985 986 986 (% border="1" style="background-color:#f7faff" %) ... ... @@ -989,7 +989,6 @@ 989 989 |0x00|DO2 set to high 990 990 |0x11|DO2 NO Action 991 991 992 - 993 993 **Fifth Byte**: Control Method and Ports status: 994 994 995 995 (% border="1" style="background-color:#f7faff" %) ... ... @@ -1094,7 +1094,6 @@ 1094 1094 |0x02|RO1 to NC, RO2 No Action 1095 1095 |0x12|RO1 to NO, RO2 No Action 1096 1096 1097 - 1098 1098 **Fourth / Fifth Bytes (cc)**: Latching time. Unit: ms 1099 1099 1100 1100 Device will upload a packet if downlink code executes successfully. ... ... @@ -1196,10 +1196,9 @@ 1196 1196 1197 1197 1198 1198 1199 -1. 1168 +1. 1200 1200 11. Integrate with Mydevice 1201 1201 1202 - 1203 1203 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: 1204 1204 1205 1205 ... ... @@ -1244,7 +1244,7 @@ 1244 1244 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image018.png]] 1245 1245 1246 1246 1247 -1. 1215 +1. 1248 1248 11. Interface Detail 1249 1249 111. Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) 1250 1250 ... ... @@ -1254,8 +1254,8 @@ 1254 1254 1255 1255 1256 1256 1257 -1. 1258 -11. 1225 +1. 1226 +11. 1259 1259 111. Digital Input Port: DI1/DI2 ( For LT-22222-L) 1260 1260 1261 1261 The DI port of LT-22222-L can support NPN or PNP output sensor. ... ... @@ -1297,7 +1297,7 @@ 1297 1297 1298 1298 **Example3**: Connect to a 220v high active sensor.公司测试一下 1299 1299 1300 -Assume user want to monitor an active signal higher than 220v, to make sure not burn the photocoupler 1268 +Assume user want to monitor an active signal higher than 220v, to make sure not burn the photocoupler 1301 1301 1302 1302 * Connect sensor’s output to DI1+ with a serial 50K resistor 1303 1303 * Connect sensor’s GND DI1-. ... ... @@ -1309,8 +1309,8 @@ 1309 1309 If sensor output is 220v, the //IF//[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]] = 4.3mA , So the LT-22222-L will be able to detect this high active signal safely. 1310 1310 1311 1311 1312 -1. 1313 -11. 1280 +1. 1281 +11. 1314 1314 111. Digital Output Port: DO1/DO2 /DO3 1315 1315 1316 1316 NPN output: GND or Float. Max voltage can apply to output pin is 36v. ... ... @@ -1320,8 +1320,8 @@ 1320 1320 1321 1321 1322 1322 1323 -1. 1324 -11. 1291 +1. 1292 +11. 1325 1325 111. Analog Input Interface 1326 1326 1327 1327 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: ... ... @@ -1353,8 +1353,8 @@ 1353 1353 1354 1354 1355 1355 1356 -1. 1357 -11. 1324 +1. 1325 +11. 1358 1358 111. Relay Output 1359 1359 1360 1360 The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device’s Power Line to in serial of RO1_1 and RO_2. Such as below: ... ... @@ -1368,10 +1368,9 @@ 1368 1368 1369 1369 1370 1370 1371 -1. 1339 +1. 1372 1372 11. LEDs Indicators 1373 1373 1374 - 1375 1375 (% border="1" style="background-color:#f7faff" %) 1376 1376 |**LEDs**|**Feature** 1377 1377 |**PWR**|Always on if there is power ... ... @@ -1406,9 +1406,6 @@ 1406 1406 |**RO1**| 1407 1407 |**RO2**| 1408 1408 1409 - 1410 - 1411 - 1412 1412 1. Use AT Command 1413 1413 11. Access AT Command 1414 1414 ... ... @@ -1518,7 +1518,7 @@ 1518 1518 1519 1519 1520 1520 1521 -1. 1485 +1. 1522 1522 11. Common AT Command Sequence 1523 1523 111. Multi-channel ABP mode (Use with SX1301/LG308) 1524 1524 ... ... @@ -1541,8 +1541,8 @@ 1541 1541 1542 1542 ATZ 1543 1543 1544 -1. 1545 -11. 1508 +1. 1509 +11. 1546 1546 111. Single-channel ABP mode (Use with LG01/LG02) 1547 1547 1548 1548 123456 Enter Password to have AT access. ... ... @@ -1581,11 +1581,10 @@ 1581 1581 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image031.png]] 1582 1582 1583 1583 1584 -1. 1585 -11. 1548 +1. 1549 +11. 1586 1586 111. Change to Class A 1587 1587 1588 - 1589 1589 If sensor JOINED 1590 1590 1591 1591 AT+CLASS=A ... ... @@ -1598,8 +1598,7 @@ 1598 1598 1599 1599 1. FAQ 1600 1600 1601 - 1602 -1. 1564 +1. 1603 1603 11. How to upgrade the image? 1604 1604 1605 1605 The LT LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to LT to: ... ... @@ -1608,7 +1608,6 @@ 1608 1608 * For bug fix 1609 1609 * Change LoRaWAN bands. 1610 1610 1611 - 1612 1612 Below shows the hardware connection for how to upload an image to the LT: 1613 1613 1614 1614 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image029.png]] ... ... @@ -1653,13 +1653,13 @@ 1653 1653 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image038.png]] 1654 1654 1655 1655 1656 -1. 1617 +1. 1657 1657 11. How to change the LoRa Frequency Bands/Region? 1658 1658 1659 1659 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. 1660 1660 1661 1661 1662 -1. 1623 +1. 1663 1663 11. How to set up LT to work with Single Channel Gateway such as LG01/LG02? 1664 1664 1665 1665 In this case, users need to set LT-33222-L to work in ABP mode & transmit in only one frequency. ... ... @@ -1702,7 +1702,7 @@ 1702 1702 1703 1703 1704 1704 1705 -1. 1666 +1. 1706 1706 11. Can I see counting event in Serial? 1707 1707 1708 1708 User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn’t support AT+DEBUG. User can update to latest firmware first. ... ... @@ -1718,7 +1718,7 @@ 1718 1718 [[http:~~/~~/wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#How_it_work>>url:http://wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#How_it_work]] 1719 1719 1720 1720 1721 -1. 1682 +1. 1722 1722 11. Have trouble to upload image. 1723 1723 1724 1724 See this link for trouble shooting: ... ... @@ -1726,7 +1726,7 @@ 1726 1726 [[http:~~/~~/wiki.dragino.com/index.php?title=Firmware_Upgrade_Trouble_Shooting#UART_upgrade_trouble_shooting>>url:http://wiki.dragino.com/index.php?title=Firmware_Upgrade_Trouble_Shooting#UART_upgrade_trouble_shooting]] 1727 1727 1728 1728 1729 -1. 1690 +1. 1730 1730 11. Why I can’t join TTN in US915 /AU915 bands? 1731 1731 1732 1732 It might be about the channels mapping. Please see this link for detail: ... ... @@ -1738,7 +1738,6 @@ 1738 1738 1739 1739 1. Order Info 1740 1740 1741 - 1742 1742 **For LT-33222-L-XXX or LT-22222-L-XXX:** 1743 1743 1744 1744 **XXX:** ... ... @@ -1753,7 +1753,6 @@ 1753 1753 * **IN865**: LT with frequency bands IN865 1754 1754 * **CN779**: LT with frequency bands CN779 1755 1755 1756 - 1757 1757 1. Packing Info 1758 1758 1759 1759 **Package Includes**: ... ... @@ -1763,7 +1763,6 @@ 1763 1763 * Bracket for controller x1 1764 1764 * Program cable x 1 1765 1765 1766 - 1767 1767 **Dimension and weight**: 1768 1768 1769 1769 * Device Size: 13.5 x 7 x 3 cm ... ... @@ -1771,7 +1771,6 @@ 1771 1771 * Package Size / pcs : 14.5 x 8 x 5 cm 1772 1772 * Weight / pcs : 170g 1773 1773 1774 - 1775 1775 1. Support 1776 1776 1777 1777 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
- image-20220523175754-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.8 KB - Content
- image-20220523175847-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.0 KB - Content
- image-20220523180452-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +4.5 KB - Content
- image-20220523180506-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +4.5 KB - Content
- image-20220523181246-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +5.5 KB - Content