From version < 128.7 >
edited by Xiaoling
on 2024/01/15 15:53
To version < 128.3 >
edited by Xiaoling
on 2023/11/17 08:44
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -53,7 +53,7 @@
53 53  
54 54  )))
55 55  
56 -== 1.2 Specifications ==
56 +== 1.2  Specifications ==
57 57  
58 58  (((
59 59  
... ... @@ -189,10 +189,9 @@
189 189  
190 190  * Counting
191 191  
192 +== 1.4  Applications ==
192 192  
193 -== 1.4 Applications ==
194 194  
195 -
196 196  * Smart Buildings & Home Automation
197 197  
198 198  * Logistics and Supply Chain Management
... ... @@ -205,12 +205,11 @@
205 205  
206 206  * Smart Factory
207 207  
208 -
209 209  == 1.5 Hardware Variants ==
210 210  
211 211  
212 212  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %)
213 -|(% style="background-color:#4F81BD;color:white; width:103px" %)**Model**|(% style="background-color:#4F81BD;color:white; width:131px" %)**Photo**|(% style="background-color:#4F81BD;color:white; width:266px" %)**Description**
211 +|(% style="background-color:#d9e2f3; color:#0070c0; width:103px" %)**Model**|(% style="background-color:#d9e2f3; color:#0070c0; width:131px" %)**Photo**|(% style="background-color:#d9e2f3; color:#0070c0; width:266px" %)**Description**
214 214  |(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)(((
215 215  (% style="text-align:center" %)
216 216  [[image:image-20230424115112-1.png||height="106" width="58"]]
... ... @@ -223,7 +223,6 @@
223 223  * 1 x Counting Port
224 224  )))
225 225  
226 -
227 227  = 2. Power ON Device =
228 228  
229 229  
... ... @@ -321,7 +321,6 @@
321 321  
322 322  * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
323 323  
324 -
325 325  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
326 326  
327 327  
... ... @@ -329,7 +329,7 @@
329 329  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. (% style="display:none" %)
330 330  
331 331  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
332 -|(% style="background-color:#4F81BD;color:white" %)**Size(bytes)**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**
328 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**
333 333  |Value|(((
334 334  AVI1 voltage
335 335  )))|(((
... ... @@ -390,7 +390,6 @@
390 390  ** DO1 is high in case there is load between DO1 and V+.
391 391  ** DO1 LED is off in both case
392 392  
393 -
394 394  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
395 395  
396 396  
... ... @@ -402,7 +402,7 @@
402 402  Total : 11 bytes payload
403 403  
404 404  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
405 -|(% style="background-color:#4F81BD;color:white" %)**Size(bytes)**|(% style="background-color:#4F81BD;color:white" %)**4**|(% style="background-color:#4F81BD;color:white" %)**4**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**
400 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**
406 406  |Value|COUNT1|COUNT2 |DIDORO*|(((
407 407  Reserve
408 408  )))|MOD
... ... @@ -469,7 +469,7 @@
469 469  **LT22222-L**: This mode the DI1 is used as a counting pin.
470 470  
471 471  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
472 -|(% style="background-color:#4F81BD;color:white" %)**Size(bytes)**|(% style="background-color:#4F81BD;color:white" %)**4**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**
467 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**
473 473  |Value|COUNT1|(((
474 474  ACI1 Current
475 475  )))|(((
... ... @@ -522,7 +522,7 @@
522 522  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
523 523  
524 524  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
525 -|(% style="background-color:#4F81BD;color:white" %)**Size(bytes)**|(% style="background-color:#4F81BD;color:white" %)**4**|(% style="background-color:#4F81BD;color:white" %)**4**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**
520 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**
526 526  |Value|COUNT1|AVI1 Counting|DIDORO*|(((
527 527  Reserve
528 528  )))|MOD
... ... @@ -582,7 +582,7 @@
582 582  **LT22222-L**: This mode the DI1 is used as a counting pin.
583 583  
584 584  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
585 -|(% style="background-color:#4F81BD;color:white" %)**Size(bytes)**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**
580 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**
586 586  |Value|(((
587 587  AVI1 voltage
588 588  )))|(((
... ... @@ -718,7 +718,7 @@
718 718  MOD6 Payload : total 11 bytes payload
719 719  
720 720  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
721 -|(% style="background-color:#4F81BD;color:white; width:60px" %)**Size(bytes)**|(% style="background-color:#4F81BD;color:white; width:69px" %)**1**|(% style="background-color:#4F81BD;color:white; width:69px" %)**1**|(% style="background-color:#4F81BD;color:white; width:109px" %)**1**|(% style="background-color:#4F81BD;color:white; width:49px" %)**6**|(% style="background-color:#4F81BD;color:white; width:109px" %)**1**|(% style="background-color:#4F81BD;color:white; width:50px" %)**1**
716 +|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:69px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:69px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:109px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:49px" %)**6**|(% style="background-color:#d9e2f3; color:#0070c0; width:109px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**1**
722 722  |Value|(((
723 723  TRI_A FLAG
724 724  )))|(((
... ... @@ -837,7 +837,6 @@
837 837  
838 838  * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
839 839  
840 -
841 841  === 3.4.1 Common Commands ===
842 842  
843 843  
... ... @@ -1047,7 +1047,7 @@
1047 1047  01: Low,  00: High ,  11: No action
1048 1048  
1049 1049  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1050 -|(% style="background-color:#4F81BD;color:white" %)**Downlink Code**|(% style="background-color:#4F81BD;color:white" %)**DO1**|(% style="background-color:#4F81BD;color:white" %)**DO2**|(% style="background-color:#4F81BD;color:white" %)**DO3**
1044 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Downlink Code**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO3**
1051 1051  |02  01  00  11|Low|High|No Action
1052 1052  |02  00  11  01|High|No Action|Low
1053 1053  |02  11  01  00|No Action|Low|High
... ... @@ -1090,7 +1090,7 @@
1090 1090  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1091 1091  
1092 1092  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %)
1093 -|(% style="background-color:#4F81BD;color:white" %)**Second Byte**|(% style="background-color:#4F81BD;color:white" %)**Status**
1087 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status**
1094 1094  |0x01|DO1 set to low
1095 1095  |0x00|DO1 set to high
1096 1096  |0x11|DO1 NO Action
... ... @@ -1098,7 +1098,7 @@
1098 1098  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1099 1099  
1100 1100  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %)
1101 -|(% style="background-color:#4F81BD;color:white" %)**Second Byte**|(% style="background-color:#4F81BD;color:white" %)**Status**
1095 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status**
1102 1102  |0x01|DO2 set to low
1103 1103  |0x00|DO2 set to high
1104 1104  |0x11|DO2 NO Action
... ... @@ -1106,7 +1106,7 @@
1106 1106  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1107 1107  
1108 1108  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %)
1109 -|(% style="background-color:#4F81BD;color:white" %)**Second Byte**|(% style="background-color:#4F81BD;color:white" %)**Status**
1103 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status**
1110 1110  |0x01|DO3 set to low
1111 1111  |0x00|DO3 set to high
1112 1112  |0x11|DO3 NO Action
... ... @@ -1164,7 +1164,7 @@
1164 1164  01: Close ,  00: Open , 11: No action
1165 1165  
1166 1166  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:320px" %)
1167 -|(% style="background-color:#4F81BD;color:white" %)**Downlink Code**|(% style="background-color:#4F81BD;color:white" %)**RO1**|(% style="background-color:#4F81BD;color:white" %)**RO2**
1161 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Downlink Code**|(% style="background-color:#d9e2f3; color:#0070c0" %)**RO1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**RO2**
1168 1168  |03  00  11|Open|No Action
1169 1169  |03  01  11|Close|No Action
1170 1170  |03  11  00|No Action|Open
... ... @@ -1663,7 +1663,7 @@
1663 1663  
1664 1664  
1665 1665  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
1666 -|(% style="background-color:#4F81BD;color:white; width:50px" %)**LEDs**|(% style="background-color:#4F81BD;color:white; width:470px" %)**Feature**
1660 +|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**LEDs**|(% style="background-color:#d9e2f3; color:#0070c0; width:470px" %)**Feature**
1667 1667  |**PWR**|Always on if there is power
1668 1668  |**SYS**|(((
1669 1669  After device is powered on, the SYS will **fast blink in GREEN** for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be **on GREEN for 5 seconds. **SYS will **blink Blue** on every upload and **blink Green** once receive a downlink message.
... ... @@ -1697,7 +1697,6 @@
1697 1697  |**RO1**|
1698 1698  |**RO2**|
1699 1699  
1700 -
1701 1701  = 4. Use AT Command =
1702 1702  
1703 1703  == 4.1 Access AT Command ==
... ... @@ -2281,11 +2281,11 @@
2281 2281  )))
2282 2282  
2283 2283  
2284 -== 7.4 Why can LT22222 perform Uplink normally, but cannot receive Downlink? ==
2277 +== 7.4  Why can LT22222 perform Uplink normally, but cannot receive Downlink? ==
2285 2285  
2286 2286  
2287 2287  The FCD count of the gateway is inconsistent with the FCD count of the node, causing the downlink to remain in the queue state.
2288 -Use this command to bring their counts back together: [[Resets the downlink packet count>>||anchor="H3.4.2.23Resetsthedownlinkpacketcount"]]
2281 +Use this command to bring their counts back together: [[Resets the downlink packet count>>||anchor="3.4.2.23Resetsthedownlinkpacketcount"]]
2289 2289  
2290 2290  
2291 2291  = 8. Order Info =
... ... @@ -2305,7 +2305,6 @@
2305 2305  * (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
2306 2306  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2307 2307  
2308 -
2309 2309  = 9. Packing Info =
2310 2310  
2311 2311  
... ... @@ -2323,7 +2323,6 @@
2323 2323  * Package Size / pcs : 14.5 x 8 x 5 cm
2324 2324  * Weight / pcs : 170g
2325 2325  
2326 -
2327 2327  = 10. Support =
2328 2328  
2329 2329  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0