From version < 128.7 >
edited by Xiaoling
on 2024/01/15 15:53
To version < 126.25 >
edited by Xiaoling
on 2023/06/19 16:41
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -53,7 +53,7 @@
53 53  
54 54  )))
55 55  
56 -== 1.2 Specifications ==
56 +== 1.2  Specifications ==
57 57  
58 58  (((
59 59  
... ... @@ -190,9 +190,10 @@
190 190  * Counting
191 191  
192 192  
193 -== 1.4 Applications ==
194 194  
194 +== 1.4  Applications ==
195 195  
196 +
196 196  * Smart Buildings & Home Automation
197 197  
198 198  * Logistics and Supply Chain Management
... ... @@ -206,11 +206,12 @@
206 206  * Smart Factory
207 207  
208 208  
210 +
209 209  == 1.5 Hardware Variants ==
210 210  
211 211  
212 212  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %)
213 -|(% style="background-color:#4F81BD;color:white; width:103px" %)**Model**|(% style="background-color:#4F81BD;color:white; width:131px" %)**Photo**|(% style="background-color:#4F81BD;color:white; width:266px" %)**Description**
215 +|(% style="background-color:#d9e2f3; color:#0070c0; width:103px" %)**Model**|(% style="background-color:#d9e2f3; color:#0070c0; width:131px" %)**Photo**|(% style="background-color:#d9e2f3; color:#0070c0; width:266px" %)**Description**
214 214  |(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)(((
215 215  (% style="text-align:center" %)
216 216  [[image:image-20230424115112-1.png||height="106" width="58"]]
... ... @@ -224,6 +224,7 @@
224 224  )))
225 225  
226 226  
229 +
227 227  = 2. Power ON Device =
228 228  
229 229  
... ... @@ -322,6 +322,7 @@
322 322  * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
323 323  
324 324  
328 +
325 325  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
326 326  
327 327  
... ... @@ -329,7 +329,7 @@
329 329  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. (% style="display:none" %)
330 330  
331 331  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
332 -|(% style="background-color:#4F81BD;color:white" %)**Size(bytes)**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**
336 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**
333 333  |Value|(((
334 334  AVI1 voltage
335 335  )))|(((
... ... @@ -391,6 +391,7 @@
391 391  ** DO1 LED is off in both case
392 392  
393 393  
398 +
394 394  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
395 395  
396 396  
... ... @@ -402,7 +402,7 @@
402 402  Total : 11 bytes payload
403 403  
404 404  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
405 -|(% style="background-color:#4F81BD;color:white" %)**Size(bytes)**|(% style="background-color:#4F81BD;color:white" %)**4**|(% style="background-color:#4F81BD;color:white" %)**4**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**
410 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**
406 406  |Value|COUNT1|COUNT2 |DIDORO*|(((
407 407  Reserve
408 408  )))|MOD
... ... @@ -469,7 +469,7 @@
469 469  **LT22222-L**: This mode the DI1 is used as a counting pin.
470 470  
471 471  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
472 -|(% style="background-color:#4F81BD;color:white" %)**Size(bytes)**|(% style="background-color:#4F81BD;color:white" %)**4**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**
477 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**
473 473  |Value|COUNT1|(((
474 474  ACI1 Current
475 475  )))|(((
... ... @@ -484,7 +484,7 @@
484 484  |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
485 485  )))
486 486  
487 -* RO is for relay. ROx=1 : close, ROx=0 always open.
492 +* RO is for relay. ROx=1 : closeROx=0 always open.
488 488  * FIRST: Indicate this is the first packet after join network.
489 489  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
490 490  
... ... @@ -522,7 +522,7 @@
522 522  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
523 523  
524 524  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
525 -|(% style="background-color:#4F81BD;color:white" %)**Size(bytes)**|(% style="background-color:#4F81BD;color:white" %)**4**|(% style="background-color:#4F81BD;color:white" %)**4**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**
530 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**
526 526  |Value|COUNT1|AVI1 Counting|DIDORO*|(((
527 527  Reserve
528 528  )))|MOD
... ... @@ -536,7 +536,7 @@
536 536  |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
537 537  )))
538 538  
539 -* RO is for relay. ROx=1 : close, ROx=0 always open.
544 +* RO is for relay. ROx=1 : closeROx=0 always open.
540 540  * FIRST: Indicate this is the first packet after join network.
541 541  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
542 542  
... ... @@ -582,7 +582,7 @@
582 582  **LT22222-L**: This mode the DI1 is used as a counting pin.
583 583  
584 584  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
585 -|(% style="background-color:#4F81BD;color:white" %)**Size(bytes)**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**2**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**|(% style="background-color:#4F81BD;color:white" %)**1**
590 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**
586 586  |Value|(((
587 587  AVI1 voltage
588 588  )))|(((
... ... @@ -601,7 +601,7 @@
601 601  |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
602 602  )))
603 603  
604 -* RO is for relay. ROx=1 : close, ROx=0 always open.
609 +* RO is for relay. ROx=1 : closeROx=0 always open.
605 605  * FIRST: Indicate this is the first packet after join network.
606 606  * (((
607 607  DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
... ... @@ -718,7 +718,7 @@
718 718  MOD6 Payload : total 11 bytes payload
719 719  
720 720  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
721 -|(% style="background-color:#4F81BD;color:white; width:60px" %)**Size(bytes)**|(% style="background-color:#4F81BD;color:white; width:69px" %)**1**|(% style="background-color:#4F81BD;color:white; width:69px" %)**1**|(% style="background-color:#4F81BD;color:white; width:109px" %)**1**|(% style="background-color:#4F81BD;color:white; width:49px" %)**6**|(% style="background-color:#4F81BD;color:white; width:109px" %)**1**|(% style="background-color:#4F81BD;color:white; width:50px" %)**1**
726 +|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:69px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:69px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:109px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:49px" %)**6**|(% style="background-color:#d9e2f3; color:#0070c0; width:109px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**1**
722 722  |Value|(((
723 723  TRI_A FLAG
724 724  )))|(((
... ... @@ -838,6 +838,7 @@
838 838  * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
839 839  
840 840  
846 +
841 841  === 3.4.1 Common Commands ===
842 842  
843 843  
... ... @@ -1047,7 +1047,7 @@
1047 1047  01: Low,  00: High ,  11: No action
1048 1048  
1049 1049  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1050 -|(% style="background-color:#4F81BD;color:white" %)**Downlink Code**|(% style="background-color:#4F81BD;color:white" %)**DO1**|(% style="background-color:#4F81BD;color:white" %)**DO2**|(% style="background-color:#4F81BD;color:white" %)**DO3**
1056 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Downlink Code**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO3**
1051 1051  |02  01  00  11|Low|High|No Action
1052 1052  |02  00  11  01|High|No Action|Low
1053 1053  |02  11  01  00|No Action|Low|High
... ... @@ -1090,7 +1090,7 @@
1090 1090  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1091 1091  
1092 1092  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %)
1093 -|(% style="background-color:#4F81BD;color:white" %)**Second Byte**|(% style="background-color:#4F81BD;color:white" %)**Status**
1099 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status**
1094 1094  |0x01|DO1 set to low
1095 1095  |0x00|DO1 set to high
1096 1096  |0x11|DO1 NO Action
... ... @@ -1098,7 +1098,7 @@
1098 1098  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1099 1099  
1100 1100  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %)
1101 -|(% style="background-color:#4F81BD;color:white" %)**Second Byte**|(% style="background-color:#4F81BD;color:white" %)**Status**
1107 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status**
1102 1102  |0x01|DO2 set to low
1103 1103  |0x00|DO2 set to high
1104 1104  |0x11|DO2 NO Action
... ... @@ -1106,7 +1106,7 @@
1106 1106  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1107 1107  
1108 1108  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %)
1109 -|(% style="background-color:#4F81BD;color:white" %)**Second Byte**|(% style="background-color:#4F81BD;color:white" %)**Status**
1115 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status**
1110 1110  |0x01|DO3 set to low
1111 1111  |0x00|DO3 set to high
1112 1112  |0x11|DO3 NO Action
... ... @@ -1143,7 +1143,7 @@
1143 1143  
1144 1144  
1145 1145  
1146 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1152 +==== 3.4.2. 14 Relay ~-~- Control Relay Output RO1/RO2 ====
1147 1147  
1148 1148  
1149 1149  * (% style="color:#037691" %)**AT Command:**
... ... @@ -1164,7 +1164,7 @@
1164 1164  01: Close ,  00: Open , 11: No action
1165 1165  
1166 1166  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:320px" %)
1167 -|(% style="background-color:#4F81BD;color:white" %)**Downlink Code**|(% style="background-color:#4F81BD;color:white" %)**RO1**|(% style="background-color:#4F81BD;color:white" %)**RO2**
1173 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Downlink Code**|(% style="background-color:#d9e2f3; color:#0070c0" %)**RO1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**RO2**
1168 1168  |03  00  11|Open|No Action
1169 1169  |03  01  11|Close|No Action
1170 1170  |03  11  00|No Action|Open
... ... @@ -1663,7 +1663,7 @@
1663 1663  
1664 1664  
1665 1665  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
1666 -|(% style="background-color:#4F81BD;color:white; width:50px" %)**LEDs**|(% style="background-color:#4F81BD;color:white; width:470px" %)**Feature**
1672 +|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**LEDs**|(% style="background-color:#d9e2f3; color:#0070c0; width:470px" %)**Feature**
1667 1667  |**PWR**|Always on if there is power
1668 1668  |**SYS**|(((
1669 1669  After device is powered on, the SYS will **fast blink in GREEN** for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be **on GREEN for 5 seconds. **SYS will **blink Blue** on every upload and **blink Green** once receive a downlink message.
... ... @@ -1698,6 +1698,7 @@
1698 1698  |**RO2**|
1699 1699  
1700 1700  
1707 +
1701 1701  = 4. Use AT Command =
1702 1702  
1703 1703  == 4.1 Access AT Command ==
... ... @@ -2097,6 +2097,7 @@
2097 2097  
2098 2098  (% style="color:red" %)**Notice**(%%): In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
2099 2099  
2107 +
2100 2100  [[image:1653360054704-518.png||height="186" width="745"]]
2101 2101  
2102 2102  
... ... @@ -2186,7 +2186,7 @@
2186 2186  [[image:1653360498588-932.png||height="485" width="726"]]
2187 2187  
2188 2188  
2189 -== 6.4 How to change the uplink interval? ==
2197 +== 6.4 How to change the uplink interval ==
2190 2190  
2191 2191  
2192 2192  Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/]]
... ... @@ -2235,12 +2235,6 @@
2235 2235  Firmware version needs to be no less than 1.6.0.
2236 2236  
2237 2237  
2238 -== 6.10 Why does the LT22222 always report 15.585V when measuring AVI? ==
2239 -
2240 -
2241 -It is likely that the GND is not connected during the measurement, or the wire connected to the GND is loose.
2242 -
2243 -
2244 2244  = 7. Trouble Shooting =
2245 2245  )))
2246 2246  
... ... @@ -2281,13 +2281,6 @@
2281 2281  )))
2282 2282  
2283 2283  
2284 -== 7.4 Why can LT22222 perform Uplink normally, but cannot receive Downlink? ==
2285 -
2286 -
2287 -The FCD count of the gateway is inconsistent with the FCD count of the node, causing the downlink to remain in the queue state.
2288 -Use this command to bring their counts back together: [[Resets the downlink packet count>>||anchor="H3.4.2.23Resetsthedownlinkpacketcount"]]
2289 -
2290 -
2291 2291  = 8. Order Info =
2292 2292  
2293 2293  
... ... @@ -2306,6 +2306,7 @@
2306 2306  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2307 2307  
2308 2308  
2304 +
2309 2309  = 9. Packing Info =
2310 2310  
2311 2311  
... ... @@ -2324,6 +2324,7 @@
2324 2324  * Weight / pcs : 170g
2325 2325  
2326 2326  
2323 +
2327 2327  = 10. Support =
2328 2328  
2329 2329  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0