From version < 127.2 >
edited by Xiaoling
on 2023/08/21 15:27
To version < 128.5 >
edited by Xiaoling
on 2023/11/17 08:46
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -53,7 +53,7 @@
53 53  
54 54  )))
55 55  
56 -== 1.2  Specifications ==
56 +== 1.2 Specifications ==
57 57  
58 58  (((
59 59  
... ... @@ -189,11 +189,9 @@
189 189  
190 190  * Counting
191 191  
192 +== 1.4 Applications ==
192 192  
193 193  
194 -== 1.4  Applications ==
195 -
196 -
197 197  * Smart Buildings & Home Automation
198 198  
199 199  * Logistics and Supply Chain Management
... ... @@ -206,8 +206,6 @@
206 206  
207 207  * Smart Factory
208 208  
209 -
210 -
211 211  == 1.5 Hardware Variants ==
212 212  
213 213  
... ... @@ -225,8 +225,6 @@
225 225  * 1 x Counting Port
226 226  )))
227 227  
228 -
229 -
230 230  = 2. Power ON Device =
231 231  
232 232  
... ... @@ -324,8 +324,6 @@
324 324  
325 325  * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
326 326  
327 -
328 -
329 329  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
330 330  
331 331  
... ... @@ -394,8 +394,6 @@
394 394  ** DO1 is high in case there is load between DO1 and V+.
395 395  ** DO1 LED is off in both case
396 396  
397 -
398 -
399 399  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
400 400  
401 401  
... ... @@ -842,8 +842,6 @@
842 842  
843 843  * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
844 844  
845 -
846 -
847 847  === 3.4.1 Common Commands ===
848 848  
849 849  
... ... @@ -1149,7 +1149,7 @@
1149 1149  
1150 1150  
1151 1151  
1152 -==== 3.4.2. 14 Relay ~-~- Control Relay Output RO1/RO2 ====
1140 +==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1153 1153  
1154 1154  
1155 1155  * (% style="color:#037691" %)**AT Command:**
... ... @@ -1703,8 +1703,6 @@
1703 1703  |**RO1**|
1704 1704  |**RO2**|
1705 1705  
1706 -
1707 -
1708 1708  = 4. Use AT Command =
1709 1709  
1710 1710  == 4.1 Access AT Command ==
... ... @@ -2288,6 +2288,13 @@
2288 2288  )))
2289 2289  
2290 2290  
2277 +== 7.4 Why can LT22222 perform Uplink normally, but cannot receive Downlink? ==
2278 +
2279 +
2280 +The FCD count of the gateway is inconsistent with the FCD count of the node, causing the downlink to remain in the queue state.
2281 +Use this command to bring their counts back together: [[Resets the downlink packet count>>||anchor="H3.4.2.23Resetsthedownlinkpacketcount"]]
2282 +
2283 +
2291 2291  = 8. Order Info =
2292 2292  
2293 2293  
... ... @@ -2305,8 +2305,6 @@
2305 2305  * (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
2306 2306  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2307 2307  
2308 -
2309 -
2310 2310  = 9. Packing Info =
2311 2311  
2312 2312  
... ... @@ -2324,8 +2324,6 @@
2324 2324  * Package Size / pcs : 14.5 x 8 x 5 cm
2325 2325  * Weight / pcs : 170g
2326 2326  
2327 -
2328 -
2329 2329  = 10. Support =
2330 2330  
2331 2331  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0