From version < 126.9 >
edited by Xiaoling
on 2023/06/19 15:54
To version < 126.16 >
edited by Xiaoling
on 2023/06/19 16:16
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -205,8 +205,6 @@
205 205  * Smart Factory
206 206  
207 207  
208 -
209 -
210 210  == 1.5 Hardware Variants ==
211 211  
212 212  
... ... @@ -391,8 +391,6 @@
391 391  ** DO1 LED is off in both case
392 392  
393 393  
394 -
395 -
396 396  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
397 397  
398 398  
... ... @@ -431,17 +431,16 @@
431 431  **To use counting mode, please run:**
432 432  )))
433 433  
434 -(% class="box infomessage" %)
435 435  
436 436  (((
432 +(% class="box infomessage" %)
433 +(((
437 437  **AT+MOD=2**
438 -)))
439 439  
440 -(((
441 441  **ATZ**
442 442  )))
438 +)))
443 443  
444 -
445 445  (((
446 446  
447 447  
... ... @@ -499,17 +499,15 @@
499 499  **To use counting mode, please run:**
500 500  )))
501 501  
497 +(((
502 502  (% class="box infomessage" %)
503 -
504 504  (((
505 505  **AT+MOD=3**
506 -)))
507 507  
508 -(((
509 509  **ATZ**
510 510  )))
504 +)))
511 511  
512 -
513 513  (((
514 514  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
515 515  )))
... ... @@ -546,26 +546,23 @@
546 546  
547 547  (((
548 548  (% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.**
549 -)))
550 550  
551 -(((
552 552  
544 +)))
553 553  
546 +(((
554 554  **To use this mode, please run:**
555 555  )))
556 556  
550 +(((
557 557  (% class="box infomessage" %)
558 -
559 559  (((
560 560  **AT+MOD=4**
561 -)))
562 562  
563 -(((
564 564  **ATZ**
565 565  )))
557 +)))
566 566  
567 -
568 -
569 569  (((
570 570  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
571 571  )))
... ... @@ -619,22 +619,18 @@
619 619  )))
620 620  
621 621  (((
622 -
623 -
624 624  **To use this mode, please run:**
625 625  )))
626 626  
615 +(((
627 627  (% class="box infomessage" %)
628 -
629 629  (((
630 630  **AT+MOD=5**
631 -)))
632 632  
633 -(((
634 634  **ATZ**
635 635  )))
622 +)))
636 636  
637 -
638 638  (((
639 639  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
640 640  )))
... ... @@ -655,6 +655,7 @@
655 655  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
656 656  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
657 657  
644 +
658 658  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
659 659  
660 660  
... ... @@ -742,7 +742,7 @@
742 742  
743 743  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
744 744  
745 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
732 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
746 746  |**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0**
747 747  |(((
748 748  AV1_LOW
... ... @@ -771,7 +771,7 @@
771 771  
772 772  (% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1byte as below
773 773  
774 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
761 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
775 775  |**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0**
776 776  |(((
777 777  AV1_LOW
... ... @@ -800,7 +800,7 @@
800 800  
801 801  (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below
802 802  
803 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
790 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
804 804  |**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0**
805 805  |N/A|N/A|N/A|N/A|DI2_STATUS|DI2_FLAG|DI1_STATUS|DI1_FLAG
806 806  
... ... @@ -2057,10 +2057,13 @@
2057 2057  
2058 2058  (((
2059 2059  (% style="color:blue" %)**If sensor JOINED:**
2047 +(((
2048 +(% class="box infomessage" %)
2049 +**AT+CLASS=A**
2060 2060  
2061 -(% style="background-color:#dcdcdc" %)**AT+CLASS=A
2062 -ATZ**
2051 +**ATZ**
2063 2063  )))
2053 +)))
2064 2064  
2065 2065  
2066 2066  = 5. Case Study =
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0