From version < 126.22 >
edited by Xiaoling
on 2023/06/19 16:35
To version < 127.1 >
edited by Bei Jinggeng
on 2023/08/21 09:08
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Bei
Content
... ... @@ -190,7 +190,6 @@
190 190  * Counting
191 191  
192 192  
193 -
194 194  == 1.4  Applications ==
195 195  
196 196  
... ... @@ -207,7 +207,6 @@
207 207  * Smart Factory
208 208  
209 209  
210 -
211 211  == 1.5 Hardware Variants ==
212 212  
213 213  
... ... @@ -226,7 +226,6 @@
226 226  )))
227 227  
228 228  
229 -
230 230  = 2. Power ON Device =
231 231  
232 232  
... ... @@ -325,7 +325,6 @@
325 325  * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
326 326  
327 327  
328 -
329 329  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
330 330  
331 331  
... ... @@ -355,7 +355,7 @@
355 355  |RO1|RO2|DI3|DI2|DI1|DO3|DO2|DO1
356 356  )))
357 357  
358 -* RO is for relay. ROx=1 : closeROx=0 always open.
354 +* RO is for relay. ROx=1 : close, ROx=0 always open.
359 359  * DI is for digital input. DIx=1: high or float, DIx=0: low.
360 360  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
361 361  
... ... @@ -366,7 +366,7 @@
366 366  
367 367  **The value for the interface is:  **
368 368  
369 -AVI1 channel voltage is 0x04AB/1000=1195DEC/1000=1.195V
365 +AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
370 370  
371 371  AVI2 channel voltage is 0x04AC/1000=1.196V
372 372  
... ... @@ -395,7 +395,6 @@
395 395  ** DO1 LED is off in both case
396 396  
397 397  
398 -
399 399  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
400 400  
401 401  
... ... @@ -420,7 +420,7 @@
420 420  |**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0**
421 421  |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
422 422  
423 -RO is for relay. ROx=1 : closeROx=0 always open.
418 +RO is for relay. ROx=1 : close , ROx=0 always open.
424 424  )))
425 425  
426 426  * FIRST: Indicate this is the first packet after join network.
... ... @@ -489,7 +489,7 @@
489 489  |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
490 490  )))
491 491  
492 -* RO is for relay. ROx=1 : closeROx=0 always open.
487 +* RO is for relay. ROx=1 : close, ROx=0 always open.
493 493  * FIRST: Indicate this is the first packet after join network.
494 494  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
495 495  
... ... @@ -541,7 +541,7 @@
541 541  |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
542 542  )))
543 543  
544 -* RO is for relay. ROx=1 : closeROx=0 always open.
539 +* RO is for relay. ROx=1 : close, ROx=0 always open.
545 545  * FIRST: Indicate this is the first packet after join network.
546 546  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
547 547  
... ... @@ -606,7 +606,7 @@
606 606  |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
607 607  )))
608 608  
609 -* RO is for relay. ROx=1 : closeROx=0 always open.
604 +* RO is for relay. ROx=1 : close, ROx=0 always open.
610 610  * FIRST: Indicate this is the first packet after join network.
611 611  * (((
612 612  DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
... ... @@ -843,7 +843,6 @@
843 843  * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
844 844  
845 845  
846 -
847 847  === 3.4.1 Common Commands ===
848 848  
849 849  
... ... @@ -1704,7 +1704,6 @@
1704 1704  |**RO2**|
1705 1705  
1706 1706  
1707 -
1708 1708  = 4. Use AT Command =
1709 1709  
1710 1710  == 4.1 Access AT Command ==
... ... @@ -2194,7 +2194,7 @@
2194 2194  [[image:1653360498588-932.png||height="485" width="726"]]
2195 2195  
2196 2196  
2197 -== 6.4 How to change the uplink interval ==
2190 +== 6.4 How to change the uplink interval? ==
2198 2198  
2199 2199  
2200 2200  Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/]]
... ... @@ -2242,7 +2242,13 @@
2242 2242  
2243 2243  Firmware version needs to be no less than 1.6.0.
2244 2244  
2238 +== 6.10 Why does the LT22222 always report 15.585V when measuring AVI? ==
2245 2245  
2240 +
2241 +It is likely that the GND is not connected during the measurement, or the wire connected to the GND is loose.
2242 +
2243 +
2244 +
2246 2246  = 7. Trouble Shooting =
2247 2247  )))
2248 2248  
... ... @@ -2283,6 +2283,8 @@
2283 2283  )))
2284 2284  
2285 2285  
2285 +== ==
2286 +
2286 2286  = 8. Order Info =
2287 2287  
2288 2288  
... ... @@ -2301,7 +2301,6 @@
2301 2301  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2302 2302  
2303 2303  
2304 -
2305 2305  = 9. Packing Info =
2306 2306  
2307 2307  
... ... @@ -2320,7 +2320,6 @@
2320 2320  * Weight / pcs : 170g
2321 2321  
2322 2322  
2323 -
2324 2324  = 10. Support =
2325 2325  
2326 2326  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0