From version < 126.21 >
edited by Xiaoling
on 2023/06/19 16:22
To version < 126.28 >
edited by Xiaoling
on 2023/06/19 16:43
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -189,6 +189,8 @@
189 189  
190 190  * Counting
191 191  
192 +
193 +
192 192  == 1.4  Applications ==
193 193  
194 194  
... ... @@ -204,6 +204,8 @@
204 204  
205 205  * Smart Factory
206 206  
209 +
210 +
207 207  == 1.5 Hardware Variants ==
208 208  
209 209  
... ... @@ -221,6 +221,8 @@
221 221  * 1 x Counting Port
222 222  )))
223 223  
228 +
229 +
224 224  = 2. Power ON Device =
225 225  
226 226  
... ... @@ -292,7 +292,6 @@
292 292  [[image:1653298023685-319.png]]
293 293  
294 294  
295 -
296 296  (((
297 297  (% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
298 298  
... ... @@ -319,6 +319,8 @@
319 319  
320 320  * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
321 321  
327 +
328 +
322 322  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
323 323  
324 324  
... ... @@ -348,7 +348,7 @@
348 348  |RO1|RO2|DI3|DI2|DI1|DO3|DO2|DO1
349 349  )))
350 350  
351 -* RO is for relay. ROx=1 : closeROx=0 always open.
358 +* RO is for relay. ROx=1 : close, ROx=0 always open.
352 352  * DI is for digital input. DIx=1: high or float, DIx=0: low.
353 353  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
354 354  
... ... @@ -359,7 +359,7 @@
359 359  
360 360  **The value for the interface is:  **
361 361  
362 -AVI1 channel voltage is 0x04AB/1000=1195DEC/1000=1.195V
369 +AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
363 363  
364 364  AVI2 channel voltage is 0x04AC/1000=1.196V
365 365  
... ... @@ -387,6 +387,8 @@
387 387  ** DO1 is high in case there is load between DO1 and V+.
388 388  ** DO1 LED is off in both case
389 389  
397 +
398 +
390 390  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
391 391  
392 392  
... ... @@ -411,7 +411,7 @@
411 411  |**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0**
412 412  |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
413 413  
414 -RO is for relay. ROx=1 : closeROx=0 always open.
423 +RO is for relay. ROx=1 : close , ROx=0 always open.
415 415  )))
416 416  
417 417  * FIRST: Indicate this is the first packet after join network.
... ... @@ -419,6 +419,8 @@
419 419  
420 420  (((
421 421  (% style="color:red" %)**Note: DO3 bit is not valid for LT-22222-L.**
431 +
432 +
422 422  )))
423 423  
424 424  (((
... ... @@ -425,7 +425,6 @@
425 425  **To use counting mode, please run:**
426 426  )))
427 427  
428 -
429 429  (((
430 430  (% class="box infomessage" %)
431 431  (((
... ... @@ -479,7 +479,7 @@
479 479  |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
480 480  )))
481 481  
482 -* RO is for relay. ROx=1 : closeROx=0 always open.
492 +* RO is for relay. ROx=1 : close, ROx=0 always open.
483 483  * FIRST: Indicate this is the first packet after join network.
484 484  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
485 485  
... ... @@ -531,7 +531,7 @@
531 531  |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
532 532  )))
533 533  
534 -* RO is for relay. ROx=1 : closeROx=0 always open.
544 +* RO is for relay. ROx=1 : close, ROx=0 always open.
535 535  * FIRST: Indicate this is the first packet after join network.
536 536  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
537 537  
... ... @@ -596,7 +596,7 @@
596 596  |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
597 597  )))
598 598  
599 -* RO is for relay. ROx=1 : closeROx=0 always open.
609 +* RO is for relay. ROx=1 : close, ROx=0 always open.
600 600  * FIRST: Indicate this is the first packet after join network.
601 601  * (((
602 602  DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
... ... @@ -832,6 +832,8 @@
832 832  
833 833  * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
834 834  
845 +
846 +
835 835  === 3.4.1 Common Commands ===
836 836  
837 837  
... ... @@ -1429,7 +1429,6 @@
1429 1429  [[image:1653356838789-523.png||height="337" width="740"]]
1430 1430  
1431 1431  
1432 -
1433 1433  After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
1434 1434  
1435 1435  [[image:image-20220524094909-1.png||height="335" width="729"]]
... ... @@ -1583,7 +1583,6 @@
1583 1583  [[image:image-20230616235145-1.png]]
1584 1584  
1585 1585  
1586 -
1587 1587  === 3.6.3 Digital Output Port: DO1/DO2 /DO3 ===
1588 1588  
1589 1589  
... ... @@ -1693,6 +1693,8 @@
1693 1693  |**RO1**|
1694 1694  |**RO2**|
1695 1695  
1706 +
1707 +
1696 1696  = 4. Use AT Command =
1697 1697  
1698 1698  == 4.1 Access AT Command ==
... ... @@ -2182,7 +2182,7 @@
2182 2182  [[image:1653360498588-932.png||height="485" width="726"]]
2183 2183  
2184 2184  
2185 -== 6.4 How to change the uplink interval ==
2197 +== 6.4 How to change the uplink interval? ==
2186 2186  
2187 2187  
2188 2188  Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved