<
From version < 126.21 >
edited by Xiaoling
on 2023/06/19 16:22
To version < 126.18 >
edited by Xiaoling
on 2023/06/19 16:17
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -204,6 +204,7 @@
204 204  
205 205  * Smart Factory
206 206  
207 +
207 207  == 1.5 Hardware Variants ==
208 208  
209 209  
... ... @@ -387,6 +387,7 @@
387 387  ** DO1 is high in case there is load between DO1 and V+.
388 388  ** DO1 LED is off in both case
389 389  
391 +
390 390  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
391 391  
392 392  
... ... @@ -639,6 +639,7 @@
639 639  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
640 640  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
641 641  
644 +
642 642  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
643 643  
644 644  
... ... @@ -2024,6 +2024,7 @@
2024 2024  dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.**
2025 2025  
2026 2026  **4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5.**
2030 +
2027 2027  )))
2028 2028  
2029 2029  (((
... ... @@ -2036,11 +2036,13 @@
2036 2036  
2037 2037  (((
2038 2038  (% style="color:blue" %)**If sensor JOINED:**
2043 +(((
2044 +(% class="box infomessage" %)
2045 +**AT+CLASS=A**
2039 2039  
2040 -(% style="background-color:#dcdcdc" %)**AT+CLASS=A**
2041 -
2042 -(% style="background-color:#dcdcdc" %)**ATZ**
2047 +**ATZ**
2043 2043  )))
2049 +)))
2044 2044  
2045 2045  
2046 2046  = 5. Case Study =
... ... @@ -2156,21 +2156,13 @@
2156 2156  
2157 2157  (((
2158 2158  (% style="background-color:#dcdcdc" %)**123456** (%%) :  Enter Password to have AT access.
2159 -
2160 2160  (% style="background-color:#dcdcdc" %)**AT+FDR**(%%)  :  Reset Parameters to Factory Default, Keys Reserve
2161 -
2162 2162  (% style="background-color:#dcdcdc" %)**AT+NJM=0** (%%) :  Set to ABP mode
2163 -
2164 2164  (% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) :  Set the Adaptive Data Rate Off
2165 -
2166 2166  (% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) :  Set Data Rate (Set AT+DR=3 for 915 band)
2167 -
2168 2168  (% style="background-color:#dcdcdc" %)**AT+TDC=60000 **(%%) :  Set transmit interval to 60 seconds
2169 -
2170 2170  (% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) : Set transmit frequency to 868.4Mhz
2171 -
2172 2172  (% style="background-color:#dcdcdc" %)**AT+DADDR=26 01 1A F1**(%%)  :  Set Device Address to 26 01 1A F1
2173 -
2174 2174  (% style="background-color:#dcdcdc" %)**ATZ**        (%%) :  Reset MCU
2175 2175  )))
2176 2176  
... ... @@ -2288,8 +2288,6 @@
2288 2288  * (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
2289 2289  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2290 2290  
2291 -
2292 -
2293 2293  = 9. Packing Info =
2294 2294  
2295 2295  
... ... @@ -2307,8 +2307,6 @@
2307 2307  * Package Size / pcs : 14.5 x 8 x 5 cm
2308 2308  * Weight / pcs : 170g
2309 2309  
2310 -
2311 -
2312 2312  = 10. Support =
2313 2313  
2314 2314  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0