<
From version < 126.20 >
edited by Xiaoling
on 2023/06/19 16:20
To version < 126.10 >
edited by Xiaoling
on 2023/06/19 15:55
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -205,6 +205,8 @@
205 205  * Smart Factory
206 206  
207 207  
208 +
209 +
208 208  == 1.5 Hardware Variants ==
209 209  
210 210  
... ... @@ -389,6 +389,8 @@
389 389  ** DO1 LED is off in both case
390 390  
391 391  
394 +
395 +
392 392  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
393 393  
394 394  
... ... @@ -427,16 +427,17 @@
427 427  **To use counting mode, please run:**
428 428  )))
429 429  
434 +(% class="box infomessage" %)
430 430  
431 431  (((
432 -(% class="box infomessage" %)
433 -(((
434 434  **AT+MOD=2**
438 +)))
435 435  
440 +(((
436 436  **ATZ**
437 437  )))
438 -)))
439 439  
444 +
440 440  (((
441 441  
442 442  
... ... @@ -494,15 +494,17 @@
494 494  **To use counting mode, please run:**
495 495  )))
496 496  
497 -(((
498 498  (% class="box infomessage" %)
503 +
499 499  (((
500 500  **AT+MOD=3**
506 +)))
501 501  
508 +(((
502 502  **ATZ**
503 503  )))
504 -)))
505 505  
512 +
506 506  (((
507 507  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
508 508  )))
... ... @@ -539,23 +539,26 @@
539 539  
540 540  (((
541 541  (% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.**
542 -
543 -
544 544  )))
545 545  
546 546  (((
552 +
553 +
547 547  **To use this mode, please run:**
548 548  )))
549 549  
550 -(((
551 551  (% class="box infomessage" %)
558 +
552 552  (((
553 553  **AT+MOD=4**
561 +)))
554 554  
563 +(((
555 555  **ATZ**
556 556  )))
557 -)))
558 558  
567 +
568 +
559 559  (((
560 560  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
561 561  )))
... ... @@ -609,18 +609,22 @@
609 609  )))
610 610  
611 611  (((
622 +
623 +
612 612  **To use this mode, please run:**
613 613  )))
614 614  
615 -(((
616 616  (% class="box infomessage" %)
628 +
617 617  (((
618 618  **AT+MOD=5**
631 +)))
619 619  
633 +(((
620 620  **ATZ**
621 621  )))
622 -)))
623 623  
637 +
624 624  (((
625 625  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
626 626  )))
... ... @@ -641,7 +641,6 @@
641 641  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
642 642  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
643 643  
644 -
645 645  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
646 646  
647 647  
... ... @@ -2028,6 +2028,7 @@
2028 2028  
2029 2029  **4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5.**
2030 2030  
2044 +
2031 2031  )))
2032 2032  
2033 2033  (((
... ... @@ -2034,6 +2034,9 @@
2034 2034  [[image:1653359097980-169.png||height="188" width="729"]]
2035 2035  )))
2036 2036  
2051 +(((
2052 +
2053 +)))
2037 2037  
2038 2038  === 4.2.3 Change to Class A ===
2039 2039  
... ... @@ -2041,9 +2041,8 @@
2041 2041  (((
2042 2042  (% style="color:blue" %)**If sensor JOINED:**
2043 2043  
2044 -(% style="background-color:#dcdcdc" %)**AT+CLASS=A**
2045 -
2046 -(% style="background-color:#dcdcdc" %)**ATZ**
2061 +(% style="background-color:#dcdcdc" %)**AT+CLASS=A
2062 +ATZ**
2047 2047  )))
2048 2048  
2049 2049  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0