Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 6 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -LT-22222-L LoRa IO Controller User Manual 1 +LT-22222-L -- LoRa IO Controller User Manual - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.pradeeka - Content
-
... ... @@ -3,6 +3,10 @@ 3 3 4 4 5 5 6 + 7 + 8 + 9 + 6 6 **Table of Contents:** 7 7 8 8 {{toc/}} ... ... @@ -15,36 +15,30 @@ 15 15 16 16 = 1.Introduction = 17 17 18 -== 1.1 What is LT SeriesI/O Controller ==22 +== 1.1 What is the LT-22222-L I/O Controller? == 19 19 20 20 ((( 21 - 22 - 23 23 ((( 24 -The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 25 -))) 26 -))) 26 +The Dragino (% style="color:blue" %)**LT-22222-L I/O Controller**(%%) is an advanced LoRaWAN device designed to provide seamless wireless long-range connectivity with various I/O options, including analog current and voltage inputs, digital inputs and outputs, and relay outputs. 27 27 28 -((( 29 -The LT I/O Controllers allows the user to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, building automation, and so on. 28 +The LT-22222-L I/O Controller simplifies and enhances I/O monitoring and controlling. It is ideal for professional applications in wireless sensor networks, including irrigation systems, smart metering, smart cities, building automation, and more. These controllers are designed for easy, cost-effective deployment using LoRa wireless technology. 30 30 ))) 31 - 32 -((( 33 -The LT I/O Controllers is aiming to provide an (% style="color:blue" %)**easy and low cost installation** (%%)by using LoRa wireless technology. 34 34 ))) 35 35 36 36 ((( 37 - The useenvironment includes:33 +With the LT-22222-L I/O Controller, users can transmit data over ultra-long distances with low power consumption using LoRa, a spread-spectrum modulation technique derived from chirp spread spectrum (CSS) technology that operates on license-free ISM bands. 38 38 ))) 39 39 40 -((( 41 -1) If user's area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless. 42 -))) 36 +> The LT Series I/O Controllers are designed for easy, low-cost installation on LoRaWAN networks. 43 43 44 44 ((( 45 - 2) User can setupa LoRaWAN gateway locally andconfigure thecontroller toconnecttothegatewayviawireless.39 +You can connect the LT-22222-L I/O Controller to a LoRaWAN network service provider in several ways: 46 46 47 - 41 +* If there is public LoRaWAN network coverage in the area where you plan to install the device (e.g., The Things Network), you can select a network and register the LT-22222-L I/O controller with it. 42 +* If there is no public LoRaWAN coverage in your area, you can set up a LoRaWAN gateway, or multiple gateways, and connect them to a LoRaWAN network server to create adequate coverage. Then, register the LT-22222-L I/O controller with this network. 43 +* Setup your own private LoRaWAN network. 44 + 45 +> You can use the Dragino LG308 gateway to expand or create LoRaWAN coverage in your area. 48 48 ))) 49 49 50 50 ((( ... ... @@ -53,162 +53,71 @@ 53 53 54 54 ))) 55 55 56 -== 1.2 54 +== 1.2 Specifications == 57 57 58 -((( 59 - 60 - 61 61 (% style="color:#037691" %)**Hardware System:** 62 -))) 63 63 64 -* ((( 65 -STM32L072xxxx MCU 66 -))) 67 -* ((( 68 -SX1276/78 Wireless Chip 69 -))) 70 -* ((( 71 -((( 72 -Power Consumption: 73 -))) 58 +* STM32L072xxxx MCU 59 +* SX1276/78 Wireless Chip 60 +* Power Consumption: 61 +** Idle: 4mA@12v 62 +** 20dB Transmit: 34mA@12v 63 +* Operating Temperature: -40 ~~ 85 Degree, No Dew 74 74 75 -* ((( 76 -Idle: 4mA@12v 77 -))) 78 -* ((( 79 -20dB Transmit: 34mA@12v 80 -))) 81 -))) 82 - 83 -((( 84 - 85 - 86 86 (% style="color:#037691" %)**Interface for Model: LT22222-L:** 87 -))) 88 88 89 -* ((( 90 -2 x Digital dual direction Input (Detect High/Low signal, Max: 50v, or 220v with optional external resistor) 91 -))) 92 -* ((( 93 -2 x Digital Output (NPN output. Max pull up voltage 36V,450mA) 94 -))) 95 -* ((( 96 -2 x Relay Output (5A@250VAC / 30VDC) 97 -))) 98 -* ((( 99 -2 x 0~~20mA Analog Input (res:0.01mA) 100 -))) 101 -* ((( 102 -2 x 0~~30V Analog Input (res:0.01v) 103 -))) 104 -* ((( 105 -Power Input 7~~ 24V DC. 106 -))) 67 +* 2 x Digital dual direction Input (Detect High/Low signal, Max: 50v, or 220v with optional external resistor) 68 +* 2 x Digital Output (NPN output. Max pull up voltage 36V,450mA) 69 +* 2 x Relay Output (5A@250VAC / 30VDC) 70 +* 2 x 0~~20mA Analog Input (res:0.01mA) 71 +* 2 x 0~~30V Analog Input (res:0.01v) 72 +* Power Input 7~~ 24V DC. 107 107 108 -((( 109 - 110 - 111 111 (% style="color:#037691" %)**LoRa Spec:** 112 -))) 113 113 114 -* ((( 115 -((( 116 -Frequency Range: 117 -))) 76 +* Frequency Range: 77 +** Band 1 (HF): 862 ~~ 1020 Mhz 78 +** Band 2 (LF): 410 ~~ 528 Mhz 79 +* 168 dB maximum link budget. 80 +* +20 dBm - 100 mW constant RF output vs. 81 +* +14 dBm high efficiency PA. 82 +* Programmable bit rate up to 300 kbps. 83 +* High sensitivity: down to -148 dBm. 84 +* Bullet-proof front end: IIP3 = -12.5 dBm. 85 +* Excellent blocking immunity. 86 +* Low RX current of 10.3 mA, 200 nA register retention. 87 +* Fully integrated synthesizer with a resolution of 61 Hz. 88 +* FSK, GFSK, MSK, GMSK, LoRaTM and OOK modulation. 89 +* Built-in bit synchronizer for clock recovery. 90 +* Preamble detection. 91 +* 127 dB Dynamic Range RSSI. 92 +* Automatic RF Sense and CAD with ultra-fast AFC. 93 +* Packet engine up to 256 bytes with CRC. 118 118 119 -* ((( 120 -Band 1 (HF): 862 ~~ 1020 Mhz 121 -))) 122 -* ((( 123 -Band 2 (LF): 410 ~~ 528 Mhz 124 -))) 125 -))) 126 -* ((( 127 -168 dB maximum link budget. 128 -))) 129 -* ((( 130 -+20 dBm - 100 mW constant RF output vs. 131 -))) 132 -* ((( 133 -+14 dBm high efficiency PA. 134 -))) 135 -* ((( 136 -Programmable bit rate up to 300 kbps. 137 -))) 138 -* ((( 139 -High sensitivity: down to -148 dBm. 140 -))) 141 -* ((( 142 -Bullet-proof front end: IIP3 = -12.5 dBm. 143 -))) 144 -* ((( 145 -Excellent blocking immunity. 146 -))) 147 -* ((( 148 -Low RX current of 10.3 mA, 200 nA register retention. 149 -))) 150 -* ((( 151 -Fully integrated synthesizer with a resolution of 61 Hz. 152 -))) 153 -* ((( 154 -FSK, GFSK, MSK, GMSK, LoRaTM and OOK modulation. 155 -))) 156 -* ((( 157 -Built-in bit synchronizer for clock recovery. 158 -))) 159 -* ((( 160 -Preamble detection. 161 -))) 162 -* ((( 163 -127 dB Dynamic Range RSSI. 164 -))) 165 -* ((( 166 -Automatic RF Sense and CAD with ultra-fast AFC. 167 -))) 168 -* ((( 169 -Packet engine up to 256 bytes with CRC. 170 - 171 - 172 - 173 -))) 174 - 175 175 == 1.3 Features == 176 176 177 - 178 178 * LoRaWAN Class A & Class C protocol 179 - 180 180 * Optional Customized LoRa Protocol 181 - 182 182 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865/MA869 183 - 184 184 * AT Commands to change parameters 185 - 186 186 * Remote configure parameters via LoRa Downlink 187 - 188 188 * Firmware upgradable via program port 189 - 190 190 * Counting 191 191 192 -== 1.4 105 +== 1.4 Applications == 193 193 194 - 195 195 * Smart Buildings & Home Automation 196 - 197 197 * Logistics and Supply Chain Management 198 - 199 199 * Smart Metering 200 - 201 201 * Smart Agriculture 202 - 203 203 * Smart Cities 204 - 205 205 * Smart Factory 206 206 207 207 == 1.5 Hardware Variants == 208 208 209 209 210 -(% border="1" style="background-color:#f2f2f2; width:500px" %) 211 -|(% style="background-color:# d9e2f3; color:#0070c0; width:103px" %)**Model**|(% style="background-color:#d9e2f3; color:#0070c0; width:131px" %)**Photo**|(% style="background-color:#d9e2f3; color:#0070c0; width:334px" %)**Description**117 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %) 118 +|(% style="background-color:#4f81bd; color:white; width:103px" %)**Model**|(% style="background-color:#4f81bd; color:white; width:131px" %)**Photo**|(% style="background-color:#4f81bd; color:white; width:266px" %)**Description** 212 212 |(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)((( 213 213 (% style="text-align:center" %) 214 214 [[image:image-20230424115112-1.png||height="106" width="58"]] ... ... @@ -221,84 +221,124 @@ 221 221 * 1 x Counting Port 222 222 ))) 223 223 224 -= 2. PowerONDevice =131 += 2. Assembling the Device = 225 225 133 +== 2.1 What is included in the package? == 226 226 227 -((( 228 -The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. 229 -))) 135 +The package includes the following items: 230 230 231 -((( 232 -PWR will on when device is properly powered. 137 +* 1 x LT-22222-L I/O Controller 138 +* 1 x LoRaWAN antenna matched to the frequency of the LT-22222-L 139 +* 1 x bracket for wall mounting 140 +* 1 x programming cable 233 233 234 - 235 -))) 142 +Attach the LoRaWAN antenna to the connector labeled **ANT** (located on the top right side of the device, next to the upper terminal block). Secure the antenna by tightening it clockwise. 236 236 237 - [[image:1653297104069-180.png]]144 +== 2.2 Terminals == 238 238 146 +Upper screw terminal block (from left to right): 239 239 240 -= 3. Operation Mode = 148 +(% style="width:634px" %) 149 +|=(% style="width: 295px;" %)Terminal|=(% style="width: 338px;" %)Function 150 +|(% style="width:295px" %)GND|(% style="width:338px" %)Ground 151 +|(% style="width:295px" %)VIN|(% style="width:338px" %)Input Voltage 152 +|(% style="width:295px" %)AVI2|(% style="width:338px" %)Analog Voltage Input Terminal 2 153 +|(% style="width:295px" %)AVI1|(% style="width:338px" %)Analog Voltage Input Terminal 1 154 +|(% style="width:295px" %)ACI2|(% style="width:338px" %)Analog Current Input Terminal 2 155 +|(% style="width:295px" %)ACI1|(% style="width:338px" %)Analog Current Input Terminal 1 241 241 242 - == 3.1 Howitworks?==157 +Lower screw terminal block (from left to right): 243 243 159 +(% style="width:633px" %) 160 +|=(% style="width: 296px;" %)Terminal|=(% style="width: 334px;" %)Function 161 +|(% style="width:296px" %)RO1-2|(% style="width:334px" %)Relay Output 1 162 +|(% style="width:296px" %)RO1-1|(% style="width:334px" %)Relay Output 1 163 +|(% style="width:296px" %)RO2-2|(% style="width:334px" %)Relay Output 2 164 +|(% style="width:296px" %)RO2-1|(% style="width:334px" %)Relay Output 2 165 +|(% style="width:296px" %)DI2+|(% style="width:334px" %)Digital Input 2 166 +|(% style="width:296px" %)DI2-|(% style="width:334px" %)Digital Input 2 167 +|(% style="width:296px" %)DI1+|(% style="width:334px" %)Digital Input 1 168 +|(% style="width:296px" %)DI1-|(% style="width:334px" %)Digital Input 1 169 +|(% style="width:296px" %)DO2|(% style="width:334px" %)Digital Output 2 170 +|(% style="width:296px" %)DO1|(% style="width:334px" %)Digital Output 1 244 244 245 -((( 246 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 247 -))) 172 +== 2.3 Powering == 248 248 249 -((( 250 -In case user can't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 251 -))) 174 +The LT-22222-L I/O Controller can be powered by a 7–24V DC power source. Connect the power supply’s positive wire to the VIN screw terminal and the negative wire to the GND screw terminal. The power indicator (PWR) LED will turn on when the device is properly powered. 252 252 253 253 254 - ==3.2Example to joinLoRaWAN network ==177 +[[image:1653297104069-180.png]] 255 255 256 256 257 -((( 258 -This chapter shows an example for how to join the TTN LoRaWAN Network. Below is the network structure, we use our LG308 as LoRaWAN gateway here. 180 += 3. Operation Mode = 259 259 260 - 261 -))) 182 +== 3.1 How does it work? == 262 262 263 - [[image:image-20220523172350-1.png||height="266"width="864"]]184 +The LT-22222-L is configured to operate in LoRaWAN Class C mode by default. It supports OTAA (Over-the-Air Activation), which is the most secure method for activating a device with a LoRaWAN network server. The LT-22222-L comes with device registration information that allows you to register it with a LoRaWAN network, enabling the device to perform OTAA activation with the network server upon initial power-up and after any subsequent reboots. 264 264 186 +For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 265 265 266 -((( 267 -The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 188 +In case you can't set the root key and other identifiers in the network server and must use them from the server, you can use [[AT Commands>>||anchor="H4.UseATCommand"]] to configure them on the device. 268 268 269 - 270 -))) 190 +== 3.2 Registering with a LoRaWAN network server == 271 271 272 -((( 273 -(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller. 274 -))) 192 +The diagram below shows how the LT-22222-L connects to a typical LoRaWAN network. 275 275 276 -((( 277 -Each LT is shipped with a sticker with the default device EUI as below: 278 -))) 194 +[[image:image-20220523172350-1.png||height="266" width="864"]] 279 279 196 +=== 3.2.1 Prerequisites === 197 + 198 +Make sure you have the device registration information such as DevEUI, AppEUI, and AppKey with you. The registration information can be found on a sticker that can be found inside the package. Please keep the **registration information** sticker in a safe place for future reference. 199 + 280 280 [[image:image-20230425173427-2.png||height="246" width="530"]] 281 281 202 +The following subsections explain how to register the LT-22222-L with different LoRaWAN network server providers. 282 282 283 - Inputthesekeysin the LoRaWANServer portal. BelowisTTNscreen shot:204 +=== 3.2.2 The Things Stack Sandbox (TTSS) === 284 284 285 -**Add APP EUI in the application.** 206 +* Log in to your [[The Things Stack Sandbox>>https://eu1.cloud.thethings.network]] account. 207 +* Create an application if you do not have one yet. 208 +* Register LT-22222-L with that application. Two registration options available: 286 286 287 - [[image:1653297955910-247.png||height="321"width="716"]]210 +==== Using the LoRaWAN Device Repository: ==== 288 288 212 +* Go to your application and click on the **Register end device** button. 213 +* On the **Register end device** page: 214 +** Select the option **Select the end device in the LoRaWAN Device Repository**. 215 +** Choose the **End device brand**, **Model**, **Hardware version**, **Firmware version**, and **Profile (Region)**. 216 +** Select the **Frequency plan** that matches with your device. 289 289 290 - **Add APP KEYandDEV EUI**218 +[[image:lt-22222-l-dev-repo-reg-p1.png||height="625" width="1000"]] 291 291 292 -[[image:1653298023685-319.png]] 220 +* 221 +** Enter the **AppEUI** in the **JoinEUI** field and click **Confirm** button. 222 +** Enter the **DevEUI** in the **DevEUI** field. 223 +** Enter the **AppKey** in the **AppKey** field. 224 +** In the **End device ID** field, enter a unique name within this application for your LT-22222-N. 225 +** Under **After registration**, select the **View registered end device** option. 293 293 227 +[[image:lt-22222-l-dev-repo-reg-p2.png||height="625" width="1000"]] 294 294 229 +==== Entering device information manually: ==== 295 295 296 -((( 297 -(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 231 +* On the **Register end device** page: 232 +** Select the **Enter end device specified manually** option. 233 +** Select the **Frequency plan** that matches with your device. 234 +** Select the **LoRaWAN version**. 235 +** Select the **Regional Parameters version**. 236 +** Click **Show advanced activation, LoRaWAN class and cluster settings** option. 237 +** Select **Over the air activation (OTAA)** option under **Activation mode** 238 +** Select **Class C (Continuous)** from the **Additional LoRaWAN class capabilities**. 239 +** Enter **AppEUI** in the **JoinEUI** field and click **Confirm** button. 240 +** Enter **DevEUI** in the **DevEUI** field. 241 +** Enter **AppKey** in the **AppKey** field. 242 +** In the **End device ID** field, enter a unique name within this application for your LT-22222-N. 243 +** Under **After registration**, select the **View registered end device** option. 298 298 299 - 300 -))) 245 +==== Joining ==== 301 301 247 +Click on **Live Data** in the left navigation. Then, power on the device, and it will join The Things Stack Sandbox. You can see the join request, join accept, followed by uplink messages form the device showing in the Live Data panel. 248 + 302 302 [[image:1653298044601-602.png||height="405" width="709"]] 303 303 304 304 ... ... @@ -325,8 +325,8 @@ 325 325 ((( 326 326 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. (% style="display:none" %) 327 327 328 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:5 20px" %)329 -|(% style="background-color:# d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**275 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 276 +|(% style="background-color:#4f81bd; color:white" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1** 330 330 |Value|((( 331 331 AVI1 voltage 332 332 )))|((( ... ... @@ -343,12 +343,12 @@ 343 343 ((( 344 344 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 345 345 346 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:5 20px" %)293 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 347 347 |**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 348 348 |RO1|RO2|DI3|DI2|DI1|DO3|DO2|DO1 349 349 ))) 350 350 351 -* RO is for relay. ROx=1 : close ,ROx=0 always open.298 +* RO is for relay. ROx=1 : close, ROx=0 always open. 352 352 * DI is for digital input. DIx=1: high or float, DIx=0: low. 353 353 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 354 354 ... ... @@ -359,7 +359,7 @@ 359 359 360 360 **The value for the interface is: ** 361 361 362 -AVI1 channel voltage is 0x04AB/1000=1195 (DEC)/1000=1.195V309 +AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V 363 363 364 364 AVI2 channel voltage is 0x04AC/1000=1.196V 365 365 ... ... @@ -397,8 +397,8 @@ 397 397 ((( 398 398 Total : 11 bytes payload 399 399 400 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:5 20px" %)401 -|(% style="background-color:# d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**347 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 348 +|(% style="background-color:#4f81bd; color:white" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white" %)**4**|(% style="background-color:#4f81bd; color:white" %)**4**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1** 402 402 |Value|COUNT1|COUNT2 |DIDORO*|((( 403 403 Reserve 404 404 )))|MOD ... ... @@ -407,11 +407,11 @@ 407 407 ((( 408 408 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 409 409 410 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:5 20px" %)357 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 411 411 |**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 412 412 |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 413 413 414 -RO is for relay. ROx=1 : close ,ROx=0 always open.361 +RO is for relay. ROx=1 : close , ROx=0 always open. 415 415 ))) 416 416 417 417 * FIRST: Indicate this is the first packet after join network. ... ... @@ -419,26 +419,22 @@ 419 419 420 420 ((( 421 421 (% style="color:red" %)**Note: DO3 bit is not valid for LT-22222-L.** 422 -))) 423 423 424 -((( 425 425 371 +))) 426 426 373 +((( 427 427 **To use counting mode, please run:** 428 428 ))) 429 429 377 +((( 430 430 (% class="box infomessage" %) 431 431 ((( 432 -((( 433 -((( 434 434 **AT+MOD=2** 435 -))) 436 436 437 -((( 438 438 **ATZ** 439 439 ))) 440 440 ))) 441 -))) 442 442 443 443 ((( 444 444 ... ... @@ -468,8 +468,8 @@ 468 468 469 469 **LT22222-L**: This mode the DI1 is used as a counting pin. 470 470 471 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:5 20px" %)472 -|(% style="background-color:# d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**414 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 415 +|(% style="background-color:#4f81bd; color:white" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white" %)**4**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1** 473 473 |Value|COUNT1|((( 474 474 ACI1 Current 475 475 )))|((( ... ... @@ -479,12 +479,12 @@ 479 479 ((( 480 480 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 481 481 482 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:5 20px" %)425 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 483 483 |**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 484 484 |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 485 485 ))) 486 486 487 -* RO is for relay. ROx=1 : close ,ROx=0 always open.430 +* RO is for relay. ROx=1 : close, ROx=0 always open. 488 488 * FIRST: Indicate this is the first packet after join network. 489 489 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 490 490 ... ... @@ -497,18 +497,14 @@ 497 497 **To use counting mode, please run:** 498 498 ))) 499 499 443 +((( 500 500 (% class="box infomessage" %) 501 501 ((( 502 -((( 503 -((( 504 504 **AT+MOD=3** 505 -))) 506 506 507 -((( 508 508 **ATZ** 509 509 ))) 510 510 ))) 511 -))) 512 512 513 513 ((( 514 514 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. ... ... @@ -525,8 +525,8 @@ 525 525 ((( 526 526 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. 527 527 528 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:5 20px" %)529 -|(% style="background-color:# d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**467 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 468 +|(% style="background-color:#4f81bd; color:white" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white" %)**4**|(% style="background-color:#4f81bd; color:white" %)**4**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1** 530 530 |Value|COUNT1|AVI1 Counting|DIDORO*|((( 531 531 Reserve 532 532 )))|MOD ... ... @@ -535,39 +535,34 @@ 535 535 ((( 536 536 (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 537 537 538 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:5 20px" %)477 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 539 539 |**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 540 540 |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 541 541 ))) 542 542 543 -* RO is for relay. ROx=1 : close ,ROx=0 always open.482 +* RO is for relay. ROx=1 : close, ROx=0 always open. 544 544 * FIRST: Indicate this is the first packet after join network. 545 545 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 546 546 547 547 ((( 548 548 (% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.** 549 -))) 550 550 551 -((( 552 552 490 +))) 553 553 492 +((( 554 554 **To use this mode, please run:** 555 555 ))) 556 556 496 +((( 557 557 (% class="box infomessage" %) 558 558 ((( 559 -((( 560 -((( 561 561 **AT+MOD=4** 562 -))) 563 563 564 -((( 565 565 **ATZ** 566 566 ))) 567 567 ))) 568 -))) 569 569 570 - 571 571 ((( 572 572 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 573 573 ))) ... ... @@ -590,8 +590,8 @@ 590 590 591 591 **LT22222-L**: This mode the DI1 is used as a counting pin. 592 592 593 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:5 20px" %)594 -|(% style="background-color:# d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**527 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 528 +|(% style="background-color:#4f81bd; color:white" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**2**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1**|(% style="background-color:#4f81bd; color:white" %)**1** 595 595 |Value|((( 596 596 AVI1 voltage 597 597 )))|((( ... ... @@ -605,12 +605,12 @@ 605 605 ((( 606 606 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 607 607 608 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:5 20px" %)542 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 609 609 |**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 610 610 |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 611 611 ))) 612 612 613 -* RO is for relay. ROx=1 : close ,ROx=0 always open.547 +* RO is for relay. ROx=1 : close, ROx=0 always open. 614 614 * FIRST: Indicate this is the first packet after join network. 615 615 * ((( 616 616 DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. ... ... @@ -621,23 +621,17 @@ 621 621 ))) 622 622 623 623 ((( 624 - 625 - 626 626 **To use this mode, please run:** 627 627 ))) 628 628 561 +((( 629 629 (% class="box infomessage" %) 630 630 ((( 631 -((( 632 -((( 633 633 **AT+MOD=5** 634 -))) 635 635 636 -((( 637 637 **ATZ** 638 638 ))) 639 639 ))) 640 -))) 641 641 642 642 ((( 643 643 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. ... ... @@ -732,8 +732,8 @@ 732 732 733 733 MOD6 Payload : total 11 bytes payload 734 734 735 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:5 20px" %)736 -|(% style="background-color:# d9e2f3; color:#0070c0; width:60px" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:110px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**6**|(% style="background-color:#d9e2f3; color:#0070c0; width:110px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**1**663 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 664 +|(% style="background-color:#4f81bd; color:white; width:60px" %)**Size(bytes)**|(% style="background-color:#4f81bd; color:white; width:69px" %)**1**|(% style="background-color:#4f81bd; color:white; width:69px" %)**1**|(% style="background-color:#4f81bd; color:white; width:109px" %)**1**|(% style="background-color:#4f81bd; color:white; width:49px" %)**6**|(% style="background-color:#4f81bd; color:white; width:109px" %)**1**|(% style="background-color:#4f81bd; color:white; width:50px" %)**1** 737 737 |Value|((( 738 738 TRI_A FLAG 739 739 )))|((( ... ... @@ -746,7 +746,7 @@ 746 746 747 747 (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below 748 748 749 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:5 20px" %)677 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 750 750 |**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 751 751 |((( 752 752 AV1_LOW ... ... @@ -775,7 +775,7 @@ 775 775 776 776 (% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1byte as below 777 777 778 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:5 20px" %)706 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 779 779 |**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 780 780 |((( 781 781 AV1_LOW ... ... @@ -804,7 +804,7 @@ 804 804 805 805 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 806 806 807 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:5 20px" %)735 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 808 808 |**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 809 809 |N/A|N/A|N/A|N/A|DI2_STATUS|DI2_FLAG|DI1_STATUS|DI1_FLAG 810 810 ... ... @@ -1061,7 +1061,7 @@ 1061 1061 01: Low, 00: High , 11: No action 1062 1062 1063 1063 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 1064 -|(% style="background-color:# d9e2f3; color:#0070c0" %)**Downlink Code**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO3**992 +|(% style="background-color:#4f81bd; color:white" %)**Downlink Code**|(% style="background-color:#4f81bd; color:white" %)**DO1**|(% style="background-color:#4f81bd; color:white" %)**DO2**|(% style="background-color:#4f81bd; color:white" %)**DO3** 1065 1065 |02 01 00 11|Low|High|No Action 1066 1066 |02 00 11 01|High|No Action|Low 1067 1067 |02 11 01 00|No Action|Low|High ... ... @@ -1104,7 +1104,7 @@ 1104 1104 (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status: 1105 1105 1106 1106 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1107 -|(% style="background-color:# d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status**1035 +|(% style="background-color:#4f81bd; color:white" %)**Second Byte**|(% style="background-color:#4f81bd; color:white" %)**Status** 1108 1108 |0x01|DO1 set to low 1109 1109 |0x00|DO1 set to high 1110 1110 |0x11|DO1 NO Action ... ... @@ -1112,7 +1112,7 @@ 1112 1112 (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status: 1113 1113 1114 1114 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1115 -|(% style="background-color:# d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status**1043 +|(% style="background-color:#4f81bd; color:white" %)**Second Byte**|(% style="background-color:#4f81bd; color:white" %)**Status** 1116 1116 |0x01|DO2 set to low 1117 1117 |0x00|DO2 set to high 1118 1118 |0x11|DO2 NO Action ... ... @@ -1120,7 +1120,7 @@ 1120 1120 (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status: 1121 1121 1122 1122 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1123 -|(% style="background-color:# d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status**1051 +|(% style="background-color:#4f81bd; color:white" %)**Second Byte**|(% style="background-color:#4f81bd; color:white" %)**Status** 1124 1124 |0x01|DO3 set to low 1125 1125 |0x00|DO3 set to high 1126 1126 |0x11|DO3 NO Action ... ... @@ -1157,7 +1157,7 @@ 1157 1157 1158 1158 1159 1159 1160 -==== 3.4.2. 1088 +==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1161 1161 1162 1162 1163 1163 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1175,10 +1175,10 @@ 1175 1175 ))) 1176 1176 1177 1177 ((( 1178 -0 1: Close , 00: Open , 11: No action1106 +00: Close , 01: Open , 11: No action 1179 1179 1180 1180 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:320px" %) 1181 -|(% style="background-color:# d9e2f3; color:#0070c0" %)**Downlink Code**|(% style="background-color:#d9e2f3; color:#0070c0" %)**RO1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**RO2**1109 +|(% style="background-color:#4f81bd; color:white" %)**Downlink Code**|(% style="background-color:#4f81bd; color:white" %)**RO1**|(% style="background-color:#4f81bd; color:white" %)**RO2** 1182 1182 |03 00 11|Open|No Action 1183 1183 |03 01 11|Close|No Action 1184 1184 |03 11 00|No Action|Open ... ... @@ -1449,7 +1449,6 @@ 1449 1449 [[image:1653356838789-523.png||height="337" width="740"]] 1450 1450 1451 1451 1452 - 1453 1453 After added, the sensor data arrive TTN, it will also arrive and show in Mydevices. 1454 1454 1455 1455 [[image:image-20220524094909-1.png||height="335" width="729"]] ... ... @@ -1602,8 +1602,11 @@ 1602 1602 1603 1603 [[image:image-20230616235145-1.png]] 1604 1604 1532 +(% style="color:blue" %)**Example5**(%%): Connect to Open Colleactor 1605 1605 1534 +[[image:image-20240219115718-1.png]] 1606 1606 1536 + 1607 1607 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1608 1608 1609 1609 ... ... @@ -1678,12 +1678,9 @@ 1678 1678 == 3.7 LEDs Indicators == 1679 1679 1680 1680 1681 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:520px" %)1682 -|(% style="background-color:# d9e2f3; color:#0070c0; width:50px" %)**LEDs**|(% style="background-color:#d9e2f3; color:#0070c0; width:470px" %)**Feature**1611 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 1612 +|(% style="background-color:#4f81bd; color:white; width:50px" %)**LEDs**|(% style="background-color:#4f81bd; color:white; width:460px" %)**Feature** 1683 1683 |**PWR**|Always on if there is power 1684 -|**SYS**|((( 1685 -After device is powered on, the SYS will **fast blink in GREEN** for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be **on GREEN for 5 seconds. **SYS will **blink Blue** on every upload and **blink Green** once receive a downlink message. 1686 -))) 1687 1687 |**TX**|((( 1688 1688 ((( 1689 1689 Device boot: TX blinks 5 times. ... ... @@ -1698,20 +1698,16 @@ 1698 1698 ))) 1699 1699 ))) 1700 1700 |**RX**|RX blinks once when receive a packet. 1701 -|**DO1**| 1702 -|**DO2**| 1703 -|**DO3**| 1704 -|**DI2**|((( 1705 -For LT-22222-L: ON when DI2 is high, LOW when DI2 is low 1628 +|**DO1**|For LT-22222-L: ON when DO1 is low, LOW when DO1 is high 1629 +|**DO2**|For LT-22222-L: ON when DO2 is low, LOW when DO2 is high 1630 +|**DI1**|((( 1631 +For LT-22222-L: ON when DI1 is high, LOW when DI1 is low 1706 1706 ))) 1707 1707 |**DI2**|((( 1708 -For LT-22222-L: ON when DI2 is high, LOW 1634 +For LT-22222-L: ON when DI2 is high, LOW when DI2 is low 1709 1709 ))) 1710 -|**DI2**|((( 1711 -For LT-22222-L: ON when DI2 is high, LOW when DI2 is low 1712 -))) 1713 -|**RO1**| 1714 -|**RO2**| 1636 +|**RO1**|For LT-22222-L: ON when RO1 is closed, LOW when RO1 is open 1637 +|**RO2**|For LT-22222-L: ON when RO2 is closed, LOW when RO2 is open 1715 1715 1716 1716 = 4. Use AT Command = 1717 1717 ... ... @@ -1722,10 +1722,6 @@ 1722 1722 LT supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to LT for using AT command, as below. 1723 1723 ))) 1724 1724 1725 -((( 1726 - 1727 -))) 1728 - 1729 1729 [[image:1653358238933-385.png]] 1730 1730 1731 1731 ... ... @@ -2044,8 +2044,6 @@ 2044 2044 dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.** 2045 2045 2046 2046 **4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5.** 2047 - 2048 - 2049 2049 ))) 2050 2050 2051 2051 ((( ... ... @@ -2052,9 +2052,6 @@ 2052 2052 [[image:1653359097980-169.png||height="188" width="729"]] 2053 2053 ))) 2054 2054 2055 -((( 2056 - 2057 -))) 2058 2058 2059 2059 === 4.2.3 Change to Class A === 2060 2060 ... ... @@ -2062,8 +2062,9 @@ 2062 2062 ((( 2063 2063 (% style="color:blue" %)**If sensor JOINED:** 2064 2064 2065 -(% style="background-color:#dcdcdc" %)**AT+CLASS=A 2066 -ATZ** 1979 +(% style="background-color:#dcdcdc" %)**AT+CLASS=A** 1980 + 1981 +(% style="background-color:#dcdcdc" %)**ATZ** 2067 2067 ))) 2068 2068 2069 2069 ... ... @@ -2116,7 +2116,6 @@ 2116 2116 2117 2117 (% style="color:red" %)**Notice**(%%): In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 2118 2118 2119 - 2120 2120 [[image:1653360054704-518.png||height="186" width="745"]] 2121 2121 2122 2122 ... ... @@ -2180,13 +2180,21 @@ 2180 2180 2181 2181 ((( 2182 2182 (% style="background-color:#dcdcdc" %)**123456** (%%) : Enter Password to have AT access. 2097 + 2183 2183 (% style="background-color:#dcdcdc" %)**AT+FDR**(%%) : Reset Parameters to Factory Default, Keys Reserve 2099 + 2184 2184 (% style="background-color:#dcdcdc" %)**AT+NJM=0** (%%) : Set to ABP mode 2101 + 2185 2185 (% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) : Set the Adaptive Data Rate Off 2103 + 2186 2186 (% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) : Set Data Rate (Set AT+DR=3 for 915 band) 2105 + 2187 2187 (% style="background-color:#dcdcdc" %)**AT+TDC=60000 **(%%) : Set transmit interval to 60 seconds 2107 + 2188 2188 (% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) : Set transmit frequency to 868.4Mhz 2109 + 2189 2189 (% style="background-color:#dcdcdc" %)**AT+DADDR=26 01 1A F1**(%%) : Set Device Address to 26 01 1A F1 2111 + 2190 2190 (% style="background-color:#dcdcdc" %)**ATZ** (%%) : Reset MCU 2191 2191 ))) 2192 2192 ... ... @@ -2198,7 +2198,7 @@ 2198 2198 [[image:1653360498588-932.png||height="485" width="726"]] 2199 2199 2200 2200 2201 -== 6.4 How to change the uplink interval ?==2123 +== 6.4 How to change the uplink interval? == 2202 2202 2203 2203 2204 2204 Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/]] ... ... @@ -2247,6 +2247,12 @@ 2247 2247 Firmware version needs to be no less than 1.6.0. 2248 2248 2249 2249 2172 +== 6.10 Why does the LT22222 always report 15.585V when measuring AVI? == 2173 + 2174 + 2175 +It is likely that the GND is not connected during the measurement, or the wire connected to the GND is loose. 2176 + 2177 + 2250 2250 = 7. Trouble Shooting = 2251 2251 ))) 2252 2252 ... ... @@ -2287,6 +2287,13 @@ 2287 2287 ))) 2288 2288 2289 2289 2218 +== 7.4 Why can LT22222 perform Uplink normally, but cannot receive Downlink? == 2219 + 2220 + 2221 +The FCD count of the gateway is inconsistent with the FCD count of the node, causing the downlink to remain in the queue state. 2222 +Use this command to bring their counts back together: [[Resets the downlink packet count>>||anchor="H3.4.2.23Resetsthedownlinkpacketcount"]] 2223 + 2224 + 2290 2290 = 8. Order Info = 2291 2291 2292 2292 ... ... @@ -2340,5 +2340,3 @@ 2340 2340 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2341 2341 * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 2342 2342 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 2343 - 2344 -
- image-20240219115718-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.7 KB - Content
- lt-22222-l-dev-repo-p1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.pradeeka - Size
-
... ... @@ -1,0 +1,1 @@ 1 +391.8 KB - Content
- lt-22222-l-dev-repo-reg-p1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.pradeeka - Size
-
... ... @@ -1,0 +1,1 @@ 1 +391.7 KB - Content
- lt-22222-l-dev-repo-reg-p2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.pradeeka - Size
-
... ... @@ -1,0 +1,1 @@ 1 +319.1 KB - Content
- thingseye-io-step-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.pradeeka - Size
-
... ... @@ -1,0 +1,1 @@ 1 +191.8 KB - Content
- thingseye-io-step-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.pradeeka - Size
-
... ... @@ -1,0 +1,1 @@ 1 +260.3 KB - Content