From version < 126.18 >
edited by Xiaoling
on 2023/06/19 16:17
To version < 126.22 >
edited by Xiaoling
on 2023/06/19 16:35
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -189,6 +189,8 @@
189 189  
190 190  * Counting
191 191  
192 +
193 +
192 192  == 1.4  Applications ==
193 193  
194 194  
... ... @@ -205,6 +205,7 @@
205 205  * Smart Factory
206 206  
207 207  
210 +
208 208  == 1.5 Hardware Variants ==
209 209  
210 210  
... ... @@ -222,6 +222,8 @@
222 222  * 1 x Counting Port
223 223  )))
224 224  
228 +
229 +
225 225  = 2. Power ON Device =
226 226  
227 227  
... ... @@ -293,7 +293,6 @@
293 293  [[image:1653298023685-319.png]]
294 294  
295 295  
296 -
297 297  (((
298 298  (% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
299 299  
... ... @@ -320,6 +320,8 @@
320 320  
321 321  * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
322 322  
327 +
328 +
323 323  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
324 324  
325 325  
... ... @@ -389,6 +389,7 @@
389 389  ** DO1 LED is off in both case
390 390  
391 391  
398 +
392 392  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
393 393  
394 394  
... ... @@ -421,6 +421,8 @@
421 421  
422 422  (((
423 423  (% style="color:red" %)**Note: DO3 bit is not valid for LT-22222-L.**
431 +
432 +
424 424  )))
425 425  
426 426  (((
... ... @@ -427,7 +427,6 @@
427 427  **To use counting mode, please run:**
428 428  )))
429 429  
430 -
431 431  (((
432 432  (% class="box infomessage" %)
433 433  (((
... ... @@ -641,7 +641,6 @@
641 641  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
642 642  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
643 643  
644 -
645 645  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
646 646  
647 647  
... ... @@ -835,6 +835,8 @@
835 835  
836 836  * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
837 837  
845 +
846 +
838 838  === 3.4.1 Common Commands ===
839 839  
840 840  
... ... @@ -1432,7 +1432,6 @@
1432 1432  [[image:1653356838789-523.png||height="337" width="740"]]
1433 1433  
1434 1434  
1435 -
1436 1436  After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
1437 1437  
1438 1438  [[image:image-20220524094909-1.png||height="335" width="729"]]
... ... @@ -1586,7 +1586,6 @@
1586 1586  [[image:image-20230616235145-1.png]]
1587 1587  
1588 1588  
1589 -
1590 1590  === 3.6.3 Digital Output Port: DO1/DO2 /DO3 ===
1591 1591  
1592 1592  
... ... @@ -1696,6 +1696,8 @@
1696 1696  |**RO1**|
1697 1697  |**RO2**|
1698 1698  
1706 +
1707 +
1699 1699  = 4. Use AT Command =
1700 1700  
1701 1701  == 4.1 Access AT Command ==
... ... @@ -2027,7 +2027,6 @@
2027 2027  dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.**
2028 2028  
2029 2029  **4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5.**
2030 -
2031 2031  )))
2032 2032  
2033 2033  (((
... ... @@ -2040,13 +2040,11 @@
2040 2040  
2041 2041  (((
2042 2042  (% style="color:blue" %)**If sensor JOINED:**
2043 -(((
2044 -(% class="box infomessage" %)
2045 -**AT+CLASS=A**
2046 2046  
2047 -**ATZ**
2052 +(% style="background-color:#dcdcdc" %)**AT+CLASS=A**
2053 +
2054 +(% style="background-color:#dcdcdc" %)**ATZ**
2048 2048  )))
2049 -)))
2050 2050  
2051 2051  
2052 2052  = 5. Case Study =
... ... @@ -2162,13 +2162,21 @@
2162 2162  
2163 2163  (((
2164 2164  (% style="background-color:#dcdcdc" %)**123456** (%%) :  Enter Password to have AT access.
2171 +
2165 2165  (% style="background-color:#dcdcdc" %)**AT+FDR**(%%)  :  Reset Parameters to Factory Default, Keys Reserve
2173 +
2166 2166  (% style="background-color:#dcdcdc" %)**AT+NJM=0** (%%) :  Set to ABP mode
2175 +
2167 2167  (% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) :  Set the Adaptive Data Rate Off
2177 +
2168 2168  (% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) :  Set Data Rate (Set AT+DR=3 for 915 band)
2179 +
2169 2169  (% style="background-color:#dcdcdc" %)**AT+TDC=60000 **(%%) :  Set transmit interval to 60 seconds
2181 +
2170 2170  (% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) : Set transmit frequency to 868.4Mhz
2183 +
2171 2171  (% style="background-color:#dcdcdc" %)**AT+DADDR=26 01 1A F1**(%%)  :  Set Device Address to 26 01 1A F1
2185 +
2172 2172  (% style="background-color:#dcdcdc" %)**ATZ**        (%%) :  Reset MCU
2173 2173  )))
2174 2174  
... ... @@ -2286,6 +2286,8 @@
2286 2286  * (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
2287 2287  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2288 2288  
2303 +
2304 +
2289 2289  = 9. Packing Info =
2290 2290  
2291 2291  
... ... @@ -2303,6 +2303,8 @@
2303 2303  * Package Size / pcs : 14.5 x 8 x 5 cm
2304 2304  * Weight / pcs : 170g
2305 2305  
2322 +
2323 +
2306 2306  = 10. Support =
2307 2307  
2308 2308  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0