From version < 126.17 >
edited by Xiaoling
on 2023/06/19 16:16
To version < 126.21 >
edited by Xiaoling
on 2023/06/19 16:22
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -204,7 +204,6 @@
204 204  
205 205  * Smart Factory
206 206  
207 -
208 208  == 1.5 Hardware Variants ==
209 209  
210 210  
... ... @@ -388,7 +388,6 @@
388 388  ** DO1 is high in case there is load between DO1 and V+.
389 389  ** DO1 LED is off in both case
390 390  
391 -
392 392  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
393 393  
394 394  
... ... @@ -641,7 +641,6 @@
641 641  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
642 642  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
643 643  
644 -
645 645  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
646 646  
647 647  
... ... @@ -2027,7 +2027,6 @@
2027 2027  dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.**
2028 2028  
2029 2029  **4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5.**
2030 -
2031 2031  )))
2032 2032  
2033 2033  (((
... ... @@ -2040,13 +2040,11 @@
2040 2040  
2041 2041  (((
2042 2042  (% style="color:blue" %)**If sensor JOINED:**
2043 -(((
2044 -(% class="box infomessage" %)
2045 -**AT+CLASS=A**
2046 2046  
2047 -**ATZ**
2040 +(% style="background-color:#dcdcdc" %)**AT+CLASS=A**
2041 +
2042 +(% style="background-color:#dcdcdc" %)**ATZ**
2048 2048  )))
2049 -)))
2050 2050  
2051 2051  
2052 2052  = 5. Case Study =
... ... @@ -2162,13 +2162,21 @@
2162 2162  
2163 2163  (((
2164 2164  (% style="background-color:#dcdcdc" %)**123456** (%%) :  Enter Password to have AT access.
2159 +
2165 2165  (% style="background-color:#dcdcdc" %)**AT+FDR**(%%)  :  Reset Parameters to Factory Default, Keys Reserve
2161 +
2166 2166  (% style="background-color:#dcdcdc" %)**AT+NJM=0** (%%) :  Set to ABP mode
2163 +
2167 2167  (% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) :  Set the Adaptive Data Rate Off
2165 +
2168 2168  (% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) :  Set Data Rate (Set AT+DR=3 for 915 band)
2167 +
2169 2169  (% style="background-color:#dcdcdc" %)**AT+TDC=60000 **(%%) :  Set transmit interval to 60 seconds
2169 +
2170 2170  (% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) : Set transmit frequency to 868.4Mhz
2171 +
2171 2171  (% style="background-color:#dcdcdc" %)**AT+DADDR=26 01 1A F1**(%%)  :  Set Device Address to 26 01 1A F1
2173 +
2172 2172  (% style="background-color:#dcdcdc" %)**ATZ**        (%%) :  Reset MCU
2173 2173  )))
2174 2174  
... ... @@ -2286,6 +2286,8 @@
2286 2286  * (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
2287 2287  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2288 2288  
2291 +
2292 +
2289 2289  = 9. Packing Info =
2290 2290  
2291 2291  
... ... @@ -2303,6 +2303,8 @@
2303 2303  * Package Size / pcs : 14.5 x 8 x 5 cm
2304 2304  * Weight / pcs : 170g
2305 2305  
2310 +
2311 +
2306 2306  = 10. Support =
2307 2307  
2308 2308  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0