<
From version < 126.15 >
edited by Xiaoling
on 2023/06/19 16:14
To version < 126.21 >
edited by Xiaoling
on 2023/06/19 16:22
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -204,7 +204,6 @@
204 204  
205 205  * Smart Factory
206 206  
207 -
208 208  == 1.5 Hardware Variants ==
209 209  
210 210  
... ... @@ -388,7 +388,6 @@
388 388  ** DO1 is high in case there is load between DO1 and V+.
389 389  ** DO1 LED is off in both case
390 390  
391 -
392 392  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
393 393  
394 394  
... ... @@ -641,7 +641,6 @@
641 641  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
642 642  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
643 643  
644 -
645 645  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
646 646  
647 647  
... ... @@ -2027,8 +2027,6 @@
2027 2027  dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.**
2028 2028  
2029 2029  **4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5.**
2030 -
2031 -
2032 2032  )))
2033 2033  
2034 2034  (((
... ... @@ -2035,9 +2035,6 @@
2035 2035  [[image:1653359097980-169.png||height="188" width="729"]]
2036 2036  )))
2037 2037  
2038 -(((
2039 -
2040 -)))
2041 2041  
2042 2042  === 4.2.3 Change to Class A ===
2043 2043  
... ... @@ -2045,8 +2045,9 @@
2045 2045  (((
2046 2046  (% style="color:blue" %)**If sensor JOINED:**
2047 2047  
2048 -(% style="background-color:#dcdcdc" %)**AT+CLASS=A
2049 -ATZ**
2040 +(% style="background-color:#dcdcdc" %)**AT+CLASS=A**
2041 +
2042 +(% style="background-color:#dcdcdc" %)**ATZ**
2050 2050  )))
2051 2051  
2052 2052  
... ... @@ -2163,13 +2163,21 @@
2163 2163  
2164 2164  (((
2165 2165  (% style="background-color:#dcdcdc" %)**123456** (%%) :  Enter Password to have AT access.
2159 +
2166 2166  (% style="background-color:#dcdcdc" %)**AT+FDR**(%%)  :  Reset Parameters to Factory Default, Keys Reserve
2161 +
2167 2167  (% style="background-color:#dcdcdc" %)**AT+NJM=0** (%%) :  Set to ABP mode
2163 +
2168 2168  (% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) :  Set the Adaptive Data Rate Off
2165 +
2169 2169  (% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) :  Set Data Rate (Set AT+DR=3 for 915 band)
2167 +
2170 2170  (% style="background-color:#dcdcdc" %)**AT+TDC=60000 **(%%) :  Set transmit interval to 60 seconds
2169 +
2171 2171  (% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) : Set transmit frequency to 868.4Mhz
2171 +
2172 2172  (% style="background-color:#dcdcdc" %)**AT+DADDR=26 01 1A F1**(%%)  :  Set Device Address to 26 01 1A F1
2173 +
2173 2173  (% style="background-color:#dcdcdc" %)**ATZ**        (%%) :  Reset MCU
2174 2174  )))
2175 2175  
... ... @@ -2287,6 +2287,8 @@
2287 2287  * (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
2288 2288  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2289 2289  
2291 +
2292 +
2290 2290  = 9. Packing Info =
2291 2291  
2292 2292  
... ... @@ -2304,6 +2304,8 @@
2304 2304  * Package Size / pcs : 14.5 x 8 x 5 cm
2305 2305  * Weight / pcs : 170g
2306 2306  
2310 +
2311 +
2307 2307  = 10. Support =
2308 2308  
2309 2309  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0