<
From version < 126.14 >
edited by Xiaoling
on 2023/06/19 16:08
To version < 126.21 >
edited by Xiaoling
on 2023/06/19 16:22
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -204,7 +204,6 @@
204 204  
205 205  * Smart Factory
206 206  
207 -
208 208  == 1.5 Hardware Variants ==
209 209  
210 210  
... ... @@ -388,7 +388,6 @@
388 388  ** DO1 is high in case there is load between DO1 and V+.
389 389  ** DO1 LED is off in both case
390 390  
391 -
392 392  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
393 393  
394 394  
... ... @@ -609,8 +609,6 @@
609 609  )))
610 610  
611 611  (((
612 -
613 -
614 614  **To use this mode, please run:**
615 615  )))
616 616  
... ... @@ -643,7 +643,6 @@
643 643  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
644 644  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
645 645  
646 -
647 647  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
648 648  
649 649  
... ... @@ -2029,8 +2029,6 @@
2029 2029  dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.**
2030 2030  
2031 2031  **4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5.**
2032 -
2033 -
2034 2034  )))
2035 2035  
2036 2036  (((
... ... @@ -2037,9 +2037,6 @@
2037 2037  [[image:1653359097980-169.png||height="188" width="729"]]
2038 2038  )))
2039 2039  
2040 -(((
2041 -
2042 -)))
2043 2043  
2044 2044  === 4.2.3 Change to Class A ===
2045 2045  
... ... @@ -2047,8 +2047,9 @@
2047 2047  (((
2048 2048  (% style="color:blue" %)**If sensor JOINED:**
2049 2049  
2050 -(% style="background-color:#dcdcdc" %)**AT+CLASS=A
2051 -ATZ**
2040 +(% style="background-color:#dcdcdc" %)**AT+CLASS=A**
2041 +
2042 +(% style="background-color:#dcdcdc" %)**ATZ**
2052 2052  )))
2053 2053  
2054 2054  
... ... @@ -2165,13 +2165,21 @@
2165 2165  
2166 2166  (((
2167 2167  (% style="background-color:#dcdcdc" %)**123456** (%%) :  Enter Password to have AT access.
2159 +
2168 2168  (% style="background-color:#dcdcdc" %)**AT+FDR**(%%)  :  Reset Parameters to Factory Default, Keys Reserve
2161 +
2169 2169  (% style="background-color:#dcdcdc" %)**AT+NJM=0** (%%) :  Set to ABP mode
2163 +
2170 2170  (% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) :  Set the Adaptive Data Rate Off
2165 +
2171 2171  (% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) :  Set Data Rate (Set AT+DR=3 for 915 band)
2167 +
2172 2172  (% style="background-color:#dcdcdc" %)**AT+TDC=60000 **(%%) :  Set transmit interval to 60 seconds
2169 +
2173 2173  (% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) : Set transmit frequency to 868.4Mhz
2171 +
2174 2174  (% style="background-color:#dcdcdc" %)**AT+DADDR=26 01 1A F1**(%%)  :  Set Device Address to 26 01 1A F1
2173 +
2175 2175  (% style="background-color:#dcdcdc" %)**ATZ**        (%%) :  Reset MCU
2176 2176  )))
2177 2177  
... ... @@ -2289,6 +2289,8 @@
2289 2289  * (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
2290 2290  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2291 2291  
2291 +
2292 +
2292 2292  = 9. Packing Info =
2293 2293  
2294 2294  
... ... @@ -2306,6 +2306,8 @@
2306 2306  * Package Size / pcs : 14.5 x 8 x 5 cm
2307 2307  * Weight / pcs : 170g
2308 2308  
2310 +
2311 +
2309 2309  = 10. Support =
2310 2310  
2311 2311  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0