<
From version < 126.13 >
edited by Xiaoling
on 2023/06/19 16:05
To version < 127.1 >
edited by Bei Jinggeng
on 2023/08/21 09:08
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Bei
Content
... ... @@ -189,6 +189,7 @@
189 189  
190 190  * Counting
191 191  
192 +
192 192  == 1.4  Applications ==
193 193  
194 194  
... ... @@ -205,7 +205,6 @@
205 205  * Smart Factory
206 206  
207 207  
208 -
209 209  == 1.5 Hardware Variants ==
210 210  
211 211  
... ... @@ -223,6 +223,7 @@
223 223  * 1 x Counting Port
224 224  )))
225 225  
226 +
226 226  = 2. Power ON Device =
227 227  
228 228  
... ... @@ -294,7 +294,6 @@
294 294  [[image:1653298023685-319.png]]
295 295  
296 296  
297 -
298 298  (((
299 299  (% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
300 300  
... ... @@ -321,6 +321,7 @@
321 321  
322 322  * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
323 323  
324 +
324 324  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
325 325  
326 326  
... ... @@ -350,7 +350,7 @@
350 350  |RO1|RO2|DI3|DI2|DI1|DO3|DO2|DO1
351 351  )))
352 352  
353 -* RO is for relay. ROx=1 : closeROx=0 always open.
354 +* RO is for relay. ROx=1 : close, ROx=0 always open.
354 354  * DI is for digital input. DIx=1: high or float, DIx=0: low.
355 355  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
356 356  
... ... @@ -361,7 +361,7 @@
361 361  
362 362  **The value for the interface is:  **
363 363  
364 -AVI1 channel voltage is 0x04AB/1000=1195DEC/1000=1.195V
365 +AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
365 365  
366 366  AVI2 channel voltage is 0x04AC/1000=1.196V
367 367  
... ... @@ -390,7 +390,6 @@
390 390  ** DO1 LED is off in both case
391 391  
392 392  
393 -
394 394  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
395 395  
396 396  
... ... @@ -415,7 +415,7 @@
415 415  |**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0**
416 416  |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
417 417  
418 -RO is for relay. ROx=1 : closeROx=0 always open.
418 +RO is for relay. ROx=1 : close , ROx=0 always open.
419 419  )))
420 420  
421 421  * FIRST: Indicate this is the first packet after join network.
... ... @@ -423,6 +423,8 @@
423 423  
424 424  (((
425 425  (% style="color:red" %)**Note: DO3 bit is not valid for LT-22222-L.**
426 +
427 +
426 426  )))
427 427  
428 428  (((
... ... @@ -429,7 +429,6 @@
429 429  **To use counting mode, please run:**
430 430  )))
431 431  
432 -
433 433  (((
434 434  (% class="box infomessage" %)
435 435  (((
... ... @@ -483,7 +483,7 @@
483 483  |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
484 484  )))
485 485  
486 -* RO is for relay. ROx=1 : closeROx=0 always open.
487 +* RO is for relay. ROx=1 : close, ROx=0 always open.
487 487  * FIRST: Indicate this is the first packet after join network.
488 488  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
489 489  
... ... @@ -505,7 +505,6 @@
505 505  )))
506 506  )))
507 507  
508 -
509 509  (((
510 510  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
511 511  )))
... ... @@ -536,12 +536,14 @@
536 536  |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
537 537  )))
538 538  
539 -* RO is for relay. ROx=1 : closeROx=0 always open.
539 +* RO is for relay. ROx=1 : close, ROx=0 always open.
540 540  * FIRST: Indicate this is the first packet after join network.
541 541  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
542 542  
543 543  (((
544 544  (% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.**
545 +
546 +
545 545  )))
546 546  
547 547  (((
... ... @@ -557,7 +557,6 @@
557 557  )))
558 558  )))
559 559  
560 -
561 561  (((
562 562  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
563 563  )))
... ... @@ -600,7 +600,7 @@
600 600  |RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
601 601  )))
602 602  
603 -* RO is for relay. ROx=1 : closeROx=0 always open.
604 +* RO is for relay. ROx=1 : close, ROx=0 always open.
604 604  * FIRST: Indicate this is the first packet after join network.
605 605  * (((
606 606  DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
... ... @@ -611,12 +611,9 @@
611 611  )))
612 612  
613 613  (((
614 -
615 -
616 616  **To use this mode, please run:**
617 617  )))
618 618  
619 -
620 620  (((
621 621  (% class="box infomessage" %)
622 622  (((
... ... @@ -626,7 +626,6 @@
626 626  )))
627 627  )))
628 628  
629 -
630 630  (((
631 631  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
632 632  )))
... ... @@ -840,6 +840,7 @@
840 840  
841 841  * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
842 842  
840 +
843 843  === 3.4.1 Common Commands ===
844 844  
845 845  
... ... @@ -1437,7 +1437,6 @@
1437 1437  [[image:1653356838789-523.png||height="337" width="740"]]
1438 1438  
1439 1439  
1440 -
1441 1441  After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
1442 1442  
1443 1443  [[image:image-20220524094909-1.png||height="335" width="729"]]
... ... @@ -1591,7 +1591,6 @@
1591 1591  [[image:image-20230616235145-1.png]]
1592 1592  
1593 1593  
1594 -
1595 1595  === 3.6.3 Digital Output Port: DO1/DO2 /DO3 ===
1596 1596  
1597 1597  
... ... @@ -1701,6 +1701,7 @@
1701 1701  |**RO1**|
1702 1702  |**RO2**|
1703 1703  
1700 +
1704 1704  = 4. Use AT Command =
1705 1705  
1706 1706  == 4.1 Access AT Command ==
... ... @@ -2032,8 +2032,6 @@
2032 2032  dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.**
2033 2033  
2034 2034  **4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5.**
2035 -
2036 -
2037 2037  )))
2038 2038  
2039 2039  (((
... ... @@ -2040,9 +2040,6 @@
2040 2040  [[image:1653359097980-169.png||height="188" width="729"]]
2041 2041  )))
2042 2042  
2043 -(((
2044 -
2045 -)))
2046 2046  
2047 2047  === 4.2.3 Change to Class A ===
2048 2048  
... ... @@ -2050,8 +2050,9 @@
2050 2050  (((
2051 2051  (% style="color:blue" %)**If sensor JOINED:**
2052 2052  
2053 -(% style="background-color:#dcdcdc" %)**AT+CLASS=A
2054 -ATZ**
2045 +(% style="background-color:#dcdcdc" %)**AT+CLASS=A**
2046 +
2047 +(% style="background-color:#dcdcdc" %)**ATZ**
2055 2055  )))
2056 2056  
2057 2057  
... ... @@ -2168,13 +2168,21 @@
2168 2168  
2169 2169  (((
2170 2170  (% style="background-color:#dcdcdc" %)**123456** (%%) :  Enter Password to have AT access.
2164 +
2171 2171  (% style="background-color:#dcdcdc" %)**AT+FDR**(%%)  :  Reset Parameters to Factory Default, Keys Reserve
2166 +
2172 2172  (% style="background-color:#dcdcdc" %)**AT+NJM=0** (%%) :  Set to ABP mode
2168 +
2173 2173  (% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) :  Set the Adaptive Data Rate Off
2170 +
2174 2174  (% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) :  Set Data Rate (Set AT+DR=3 for 915 band)
2172 +
2175 2175  (% style="background-color:#dcdcdc" %)**AT+TDC=60000 **(%%) :  Set transmit interval to 60 seconds
2174 +
2176 2176  (% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) : Set transmit frequency to 868.4Mhz
2176 +
2177 2177  (% style="background-color:#dcdcdc" %)**AT+DADDR=26 01 1A F1**(%%)  :  Set Device Address to 26 01 1A F1
2178 +
2178 2178  (% style="background-color:#dcdcdc" %)**ATZ**        (%%) :  Reset MCU
2179 2179  )))
2180 2180  
... ... @@ -2186,7 +2186,7 @@
2186 2186  [[image:1653360498588-932.png||height="485" width="726"]]
2187 2187  
2188 2188  
2189 -== 6.4 How to change the uplink interval ==
2190 +== 6.4 How to change the uplink interval? ==
2190 2190  
2191 2191  
2192 2192  Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/]]
... ... @@ -2234,7 +2234,13 @@
2234 2234  
2235 2235  Firmware version needs to be no less than 1.6.0.
2236 2236  
2238 +== 6.10 Why does the LT22222 always report 15.585V when measuring AVI? ==
2237 2237  
2240 +
2241 +It is likely that the GND is not connected during the measurement, or the wire connected to the GND is loose.
2242 +
2243 +
2244 +
2238 2238  = 7. Trouble Shooting =
2239 2239  )))
2240 2240  
... ... @@ -2275,6 +2275,8 @@
2275 2275  )))
2276 2276  
2277 2277  
2285 +== ==
2286 +
2278 2278  = 8. Order Info =
2279 2279  
2280 2280  
... ... @@ -2292,6 +2292,7 @@
2292 2292  * (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
2293 2293  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2294 2294  
2304 +
2295 2295  = 9. Packing Info =
2296 2296  
2297 2297  
... ... @@ -2309,6 +2309,7 @@
2309 2309  * Package Size / pcs : 14.5 x 8 x 5 cm
2310 2310  * Weight / pcs : 170g
2311 2311  
2322 +
2312 2312  = 10. Support =
2313 2313  
2314 2314  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0