... ... @@ -205,7 +205,6 @@
205 205  * Smart Factory
206 206  
207 207  
208 -
209 209  == 1.5 Hardware Variants ==
210 210  
211 211  
... ... @@ -390,7 +390,6 @@
390 390  ** DO1 LED is off in both case
391 391  
392 392  
393 -
394 394  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
395 395  
396 396  
... ... @@ -505,7 +505,6 @@
505 505  )))
506 506  )))
507 507  
508 -
509 509  (((
510 510  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
511 511  )))
... ... @@ -542,6 +542,8 @@
542 542  
543 543  (((
544 544  (% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.**
542 +
543 +
545 545  )))
546 546  
547 547  (((
... ... @@ -549,6 +549,7 @@
549 549  )))
550 550  
551 551  (((
551 +(% class="box infomessage" %)
552 552  (((
553 553  **AT+MOD=4**
554 554  
... ... @@ -556,7 +556,6 @@
556 556  )))
557 557  )))
558 558  
559 -
560 560  (((
561 561  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
562 562  )))
... ... @@ -610,12 +610,9 @@
610 610  )))
611 611  
612 612  (((
613 -
614 -
615 615  **To use this mode, please run:**
616 616  )))
617 617  
618 -
619 619  (((
620 620  (% class="box infomessage" %)
621 621  (((
... ... @@ -625,7 +625,6 @@
625 625  )))
626 626  )))
627 627  
628 -
629 629  (((
630 630  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
631 631  )))
... ... @@ -646,6 +646,7 @@
646 646  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
647 647  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
648 648  
644 +
649 649  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
650 650  
651 651  
... ... @@ -2032,7 +2032,6 @@
2032 2032  
2033 2033  **4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5.**
2034 2034  
2035 -
2036 2036  )))
2037 2037  
2038 2038  (((
... ... @@ -2039,9 +2039,6 @@
2039 2039  [[image:1653359097980-169.png||height="188" width="729"]]
2040 2040  )))
2041 2041  
2042 -(((
2043 -
2044 -)))
2045 2045  
2046 2046  === 4.2.3 Change to Class A ===
2047 2047  
... ... @@ -2049,8 +2049,9 @@
2049 2049  (((
2050 2050  (% style="color:blue" %)**If sensor JOINED:**
2051 2051  
2052 -(% style="background-color:#dcdcdc" %)**AT+CLASS=A
2053 -ATZ**
2044 +(% style="background-color:#dcdcdc" %)**AT+CLASS=A**
2045 +
2046 +(% style="background-color:#dcdcdc" %)**ATZ**
2054 2054  )))
2055 2055  
2056 2056  