From version < 126.11 >
edited by Xiaoling
on 2023/06/19 15:59
To version < 126.21 >
edited by Xiaoling
on 2023/06/19 16:22
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -204,8 +204,6 @@
204 204  
205 205  * Smart Factory
206 206  
207 -
208 -
209 209  == 1.5 Hardware Variants ==
210 210  
211 211  
... ... @@ -389,8 +389,6 @@
389 389  ** DO1 is high in case there is load between DO1 and V+.
390 390  ** DO1 LED is off in both case
391 391  
392 -
393 -
394 394  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
395 395  
396 396  
... ... @@ -431,14 +431,14 @@
431 431  
432 432  
433 433  (((
430 +(% class="box infomessage" %)
431 +(((
434 434  **AT+MOD=2**
435 -)))
436 436  
437 -(((
438 438  **ATZ**
439 439  )))
436 +)))
440 440  
441 -
442 442  (((
443 443  
444 444  
... ... @@ -505,7 +505,6 @@
505 505  )))
506 506  )))
507 507  
508 -
509 509  (((
510 510  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
511 511  )))
... ... @@ -542,25 +542,23 @@
542 542  
543 543  (((
544 544  (% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.**
545 -)))
546 546  
547 -(((
548 548  
542 +)))
549 549  
544 +(((
550 550  **To use this mode, please run:**
551 551  )))
552 552  
553 -
554 554  (((
549 +(% class="box infomessage" %)
550 +(((
555 555  **AT+MOD=4**
556 -)))
557 557  
558 -(((
559 559  **ATZ**
560 560  )))
555 +)))
561 561  
562 -
563 -
564 564  (((
565 565  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
566 566  )))
... ... @@ -614,21 +614,18 @@
614 614  )))
615 615  
616 616  (((
617 -
618 -
619 619  **To use this mode, please run:**
620 620  )))
621 621  
622 -
623 623  (((
614 +(% class="box infomessage" %)
615 +(((
624 624  **AT+MOD=5**
625 -)))
626 626  
627 -(((
628 628  **ATZ**
629 629  )))
620 +)))
630 630  
631 -
632 632  (((
633 633  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
634 634  )))
... ... @@ -2034,8 +2034,6 @@
2034 2034  dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.**
2035 2035  
2036 2036  **4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5.**
2037 -
2038 -
2039 2039  )))
2040 2040  
2041 2041  (((
... ... @@ -2042,9 +2042,6 @@
2042 2042  [[image:1653359097980-169.png||height="188" width="729"]]
2043 2043  )))
2044 2044  
2045 -(((
2046 -
2047 -)))
2048 2048  
2049 2049  === 4.2.3 Change to Class A ===
2050 2050  
... ... @@ -2052,8 +2052,9 @@
2052 2052  (((
2053 2053  (% style="color:blue" %)**If sensor JOINED:**
2054 2054  
2055 -(% style="background-color:#dcdcdc" %)**AT+CLASS=A
2056 -ATZ**
2040 +(% style="background-color:#dcdcdc" %)**AT+CLASS=A**
2041 +
2042 +(% style="background-color:#dcdcdc" %)**ATZ**
2057 2057  )))
2058 2058  
2059 2059  
... ... @@ -2170,13 +2170,21 @@
2170 2170  
2171 2171  (((
2172 2172  (% style="background-color:#dcdcdc" %)**123456** (%%) :  Enter Password to have AT access.
2159 +
2173 2173  (% style="background-color:#dcdcdc" %)**AT+FDR**(%%)  :  Reset Parameters to Factory Default, Keys Reserve
2161 +
2174 2174  (% style="background-color:#dcdcdc" %)**AT+NJM=0** (%%) :  Set to ABP mode
2163 +
2175 2175  (% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) :  Set the Adaptive Data Rate Off
2165 +
2176 2176  (% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) :  Set Data Rate (Set AT+DR=3 for 915 band)
2167 +
2177 2177  (% style="background-color:#dcdcdc" %)**AT+TDC=60000 **(%%) :  Set transmit interval to 60 seconds
2169 +
2178 2178  (% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) : Set transmit frequency to 868.4Mhz
2171 +
2179 2179  (% style="background-color:#dcdcdc" %)**AT+DADDR=26 01 1A F1**(%%)  :  Set Device Address to 26 01 1A F1
2173 +
2180 2180  (% style="background-color:#dcdcdc" %)**ATZ**        (%%) :  Reset MCU
2181 2181  )))
2182 2182  
... ... @@ -2294,6 +2294,8 @@
2294 2294  * (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
2295 2295  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2296 2296  
2291 +
2292 +
2297 2297  = 9. Packing Info =
2298 2298  
2299 2299  
... ... @@ -2311,6 +2311,8 @@
2311 2311  * Package Size / pcs : 14.5 x 8 x 5 cm
2312 2312  * Weight / pcs : 170g
2313 2313  
2310 +
2311 +
2314 2314  = 10. Support =
2315 2315  
2316 2316  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0