Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -205,8 +205,6 @@ 205 205 * Smart Factory 206 206 207 207 208 - 209 - 210 210 == 1.5 Hardware Variants == 211 211 212 212 ... ... @@ -391,8 +391,6 @@ 391 391 ** DO1 LED is off in both case 392 392 393 393 394 - 395 - 396 396 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 397 397 398 398 ... ... @@ -431,17 +431,16 @@ 431 431 **To use counting mode, please run:** 432 432 ))) 433 433 434 -(% class="box infomessage" %) 435 435 436 436 ((( 432 +(% class="box infomessage" %) 433 +((( 437 437 **AT+MOD=2** 438 -))) 439 439 440 -((( 441 441 **ATZ** 442 442 ))) 438 +))) 443 443 444 - 445 445 ((( 446 446 447 447 ... ... @@ -499,17 +499,15 @@ 499 499 **To use counting mode, please run:** 500 500 ))) 501 501 497 +((( 502 502 (% class="box infomessage" %) 503 - 504 504 ((( 505 505 **AT+MOD=3** 506 -))) 507 507 508 -((( 509 509 **ATZ** 510 510 ))) 504 +))) 511 511 512 - 513 513 ((( 514 514 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 515 515 ))) ... ... @@ -546,26 +546,23 @@ 546 546 547 547 ((( 548 548 (% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.** 549 -))) 550 550 551 -((( 552 552 544 +))) 553 553 546 +((( 554 554 **To use this mode, please run:** 555 555 ))) 556 556 550 +((( 557 557 (% class="box infomessage" %) 558 - 559 559 ((( 560 560 **AT+MOD=4** 561 -))) 562 562 563 -((( 564 564 **ATZ** 565 565 ))) 557 +))) 566 566 567 - 568 - 569 569 ((( 570 570 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 571 571 ))) ... ... @@ -619,22 +619,18 @@ 619 619 ))) 620 620 621 621 ((( 622 - 623 - 624 624 **To use this mode, please run:** 625 625 ))) 626 626 615 +((( 627 627 (% class="box infomessage" %) 628 - 629 629 ((( 630 630 **AT+MOD=5** 631 -))) 632 632 633 -((( 634 634 **ATZ** 635 635 ))) 622 +))) 636 636 637 - 638 638 ((( 639 639 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 640 640 ))) ... ... @@ -655,6 +655,7 @@ 655 655 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 656 656 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 657 657 644 + 658 658 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 659 659 660 660 ... ... @@ -2041,7 +2041,6 @@ 2041 2041 2042 2042 **4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5.** 2043 2043 2044 - 2045 2045 ))) 2046 2046 2047 2047 ((( ... ... @@ -2048,9 +2048,6 @@ 2048 2048 [[image:1653359097980-169.png||height="188" width="729"]] 2049 2049 ))) 2050 2050 2051 -((( 2052 - 2053 -))) 2054 2054 2055 2055 === 4.2.3 Change to Class A === 2056 2056 ... ... @@ -2057,10 +2057,13 @@ 2057 2057 2058 2058 ((( 2059 2059 (% style="color:blue" %)**If sensor JOINED:** 2043 +((( 2044 +(% class="box infomessage" %) 2045 +**AT+CLASS=A** 2060 2060 2061 -(% style="background-color:#dcdcdc" %)**AT+CLASS=A 2062 -ATZ** 2047 +**ATZ** 2063 2063 ))) 2049 +))) 2064 2064 2065 2065 2066 2066 = 5. Case Study =