From version < 126.10 >
edited by Xiaoling
on 2023/06/19 15:55
To version < 126.18 >
edited by Xiaoling
on 2023/06/19 16:17
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -205,8 +205,6 @@
205 205  * Smart Factory
206 206  
207 207  
208 -
209 -
210 210  == 1.5 Hardware Variants ==
211 211  
212 212  
... ... @@ -391,8 +391,6 @@
391 391  ** DO1 LED is off in both case
392 392  
393 393  
394 -
395 -
396 396  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
397 397  
398 398  
... ... @@ -431,17 +431,16 @@
431 431  **To use counting mode, please run:**
432 432  )))
433 433  
434 -(% class="box infomessage" %)
435 435  
436 436  (((
432 +(% class="box infomessage" %)
433 +(((
437 437  **AT+MOD=2**
438 -)))
439 439  
440 -(((
441 441  **ATZ**
442 442  )))
438 +)))
443 443  
444 -
445 445  (((
446 446  
447 447  
... ... @@ -499,17 +499,15 @@
499 499  **To use counting mode, please run:**
500 500  )))
501 501  
497 +(((
502 502  (% class="box infomessage" %)
503 -
504 504  (((
505 505  **AT+MOD=3**
506 -)))
507 507  
508 -(((
509 509  **ATZ**
510 510  )))
504 +)))
511 511  
512 -
513 513  (((
514 514  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
515 515  )))
... ... @@ -546,26 +546,23 @@
546 546  
547 547  (((
548 548  (% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.**
549 -)))
550 550  
551 -(((
552 552  
544 +)))
553 553  
546 +(((
554 554  **To use this mode, please run:**
555 555  )))
556 556  
550 +(((
557 557  (% class="box infomessage" %)
558 -
559 559  (((
560 560  **AT+MOD=4**
561 -)))
562 562  
563 -(((
564 564  **ATZ**
565 565  )))
557 +)))
566 566  
567 -
568 -
569 569  (((
570 570  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
571 571  )))
... ... @@ -619,22 +619,18 @@
619 619  )))
620 620  
621 621  (((
622 -
623 -
624 624  **To use this mode, please run:**
625 625  )))
626 626  
615 +(((
627 627  (% class="box infomessage" %)
628 -
629 629  (((
630 630  **AT+MOD=5**
631 -)))
632 632  
633 -(((
634 634  **ATZ**
635 635  )))
622 +)))
636 636  
637 -
638 638  (((
639 639  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
640 640  )))
... ... @@ -655,6 +655,7 @@
655 655  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
656 656  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
657 657  
644 +
658 658  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
659 659  
660 660  
... ... @@ -2041,7 +2041,6 @@
2041 2041  
2042 2042  **4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5.**
2043 2043  
2044 -
2045 2045  )))
2046 2046  
2047 2047  (((
... ... @@ -2048,9 +2048,6 @@
2048 2048  [[image:1653359097980-169.png||height="188" width="729"]]
2049 2049  )))
2050 2050  
2051 -(((
2052 -
2053 -)))
2054 2054  
2055 2055  === 4.2.3 Change to Class A ===
2056 2056  
... ... @@ -2057,10 +2057,13 @@
2057 2057  
2058 2058  (((
2059 2059  (% style="color:blue" %)**If sensor JOINED:**
2043 +(((
2044 +(% class="box infomessage" %)
2045 +**AT+CLASS=A**
2060 2060  
2061 -(% style="background-color:#dcdcdc" %)**AT+CLASS=A
2062 -ATZ**
2047 +**ATZ**
2063 2063  )))
2049 +)))
2064 2064  
2065 2065  
2066 2066  = 5. Case Study =
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0