Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
Uploaded new attachment "image-20230608101608-2.jpeg", version {1}
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -314,15 +314,10 @@ 314 314 There are five working modes + one interrupt mode on LT for different type application: 315 315 316 316 * (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO 317 - 318 318 * (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO 319 - 320 320 * (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO 321 - 322 322 * (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO 323 - 324 324 * (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 325 - 326 326 * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 327 327 328 328 ... ... @@ -334,15 +334,19 @@ 334 334 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. (% style="display:none" %) 335 335 336 336 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 337 -| (% style="background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**332 +|**Size(bytes)(% style="display:none" %) (%%)**|**2**|**2**|**2**|**2**|**1**|**1**|**1** 338 338 |Value|((( 339 -AVI1 voltage 334 +AVI1 335 +voltage 340 340 )))|((( 341 -AVI2 voltage 337 +AVI2 338 +voltage 342 342 )))|((( 343 -ACI1 Current 340 +ACI1 341 +Current 344 344 )))|((( 345 -ACI2 Current 343 +ACI2 344 +Current 346 346 )))|DIDORO*|((( 347 347 Reserve 348 348 )))|MOD ... ... @@ -398,6 +398,8 @@ 398 398 ** DO1 is high in case there is load between DO1 and V+. 399 399 ** DO1 LED is off in both case 400 400 400 + 401 + 401 401 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 402 402 403 403 ... ... @@ -409,9 +409,11 @@ 409 409 Total : 11 bytes payload 410 410 411 411 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 412 -| (% style="background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="background-color:#D9E2F3;color:#0070C0" %)**4**|(% style="background-color:#D9E2F3;color:#0070C0" %)**4**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**413 +|**Size(bytes)**|**4**|**4**|**1**|**1**|**1** 413 413 |Value|COUNT1|COUNT2 |DIDORO*|((( 414 -Reserve 415 +Reserve 416 + 417 + 415 415 )))|MOD 416 416 ))) 417 417 ... ... @@ -485,7 +485,7 @@ 485 485 **LT22222-L**: This mode the DI1 is used as a counting pin. 486 486 487 487 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 488 -| (% style="background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="background-color:#D9E2F3;color:#0070C0" %)**4**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**491 +|**Size(bytes)**|**4**|**2**|**2**|**1**|**1**|**1** 489 489 |Value|COUNT1|((( 490 490 ACI1 Current 491 491 )))|((( ... ... @@ -545,9 +545,12 @@ 545 545 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. 546 546 547 547 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 548 -| (% style="background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="background-color:#D9E2F3;color:#0070C0" %)**4**|(% style="background-color:#D9E2F3;color:#0070C0" %)**4**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**551 +|**Size(bytes)**|**4**|**4**|**1**|**1**|**1** 549 549 |Value|COUNT1|AVI1 Counting|DIDORO*|((( 550 -Reserve)))|MOD 553 +Reserve 554 + 555 + 556 +)))|MOD 551 551 ))) 552 552 553 553 ... ... @@ -614,13 +614,16 @@ 614 614 **LT22222-L**: This mode the DI1 is used as a counting pin. 615 615 616 616 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 617 -| (% style="background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**623 +|**Size(bytes)**|**2**|**2**|**2**|**2**|**1**|**1**|**1** 618 618 |Value|((( 619 -AVI1 voltage 625 +AVI1 626 +voltage 620 620 )))|((( 621 -AVI2 voltage 628 +AVI2 629 +voltage 622 622 )))|((( 623 -ACI1 Current 631 +ACI1 632 +Current 624 624 )))|COUNT1|DIDORO*|((( 625 625 Reserve 626 626 )))|MOD ... ... @@ -773,6 +773,7 @@ 773 773 (6) 774 774 ))) 775 775 785 + 776 776 (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below 777 777 778 778 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) ... ... @@ -897,6 +897,8 @@ 897 897 898 898 * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 899 899 910 + 911 + 900 900 === 3.4.1 Common Commands === 901 901 902 902 ... ... @@ -1721,6 +1721,7 @@ 1721 1721 1722 1722 **Black: GND** 1723 1723 1736 + 1724 1724 **Connection diagram:** 1725 1725 1726 1726 [[image:1653357640609-758.png]] ... ... @@ -1728,22 +1728,6 @@ 1728 1728 [[image:1653357648330-671.png||height="155" width="733"]] 1729 1729 1730 1730 1731 -Example connected to a regulated power supply to measure voltage 1732 - 1733 -[[image:image-20230608101532-1.png||height="606" width="447"]] 1734 - 1735 -[[image:image-20230608101608-2.jpeg||height="379" width="284"]] 1736 - 1737 -[[image:image-20230608101722-3.png||height="102" width="1139"]] 1738 - 1739 - 1740 -(% style="color:blue; font-weight:bold" %)**Specifications of the regulated power**(%%) (% style="color:blue" %)**:** 1741 - 1742 -(% style="color:red" %)**Red: 12~~24v** 1743 - 1744 -**Black: GND** 1745 - 1746 - 1747 1747 === 3.6.5 Relay Output === 1748 1748 1749 1749 ... ... @@ -1797,6 +1797,8 @@ 1797 1797 |**RO1**| 1798 1798 |**RO2**| 1799 1799 1797 + 1798 + 1800 1800 = 4. Use AT Command = 1801 1801 1802 1802 == 4.1 Access AT Command == ... ... @@ -2388,6 +2388,8 @@ 2388 2388 * (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 2389 2389 * (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 2390 2390 2390 + 2391 + 2391 2391 = 9. Packing Info = 2392 2392 2393 2393 ... ... @@ -2405,6 +2405,8 @@ 2405 2405 * Package Size / pcs : 14.5 x 8 x 5 cm 2406 2406 * Weight / pcs : 170g 2407 2407 2409 + 2410 + 2408 2408 = 10. Support = 2409 2409 2410 2410
- image-20230608101722-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -25.4 KB - Content