... ... @@ -314,15 +314,10 @@ 314 314 There are five working modes + one interrupt mode on LT for different type application: 315 315 316 316 * (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO 317 - 318 318 * (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO 319 - 320 320 * (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO 321 - 322 322 * (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO 323 - 324 324 * (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 325 - 326 326 * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 327 327 328 328 ... ... @@ -334,15 +334,19 @@ 334 334 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. (% style="display:none" %) 335 335 336 336 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 337 -| (% style="background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**332 +|**Size(bytes)(% style="display:none" %) (%%)**|**2**|**2**|**2**|**2**|**1**|**1**|**1** 338 338 |Value|((( 339 -AVI1 voltage 334 +AVI1 335 +voltage 340 340 )))|((( 341 -AVI2 voltage 337 +AVI2 338 +voltage 342 342 )))|((( 343 -ACI1 Current 340 +ACI1 341 +Current 344 344 )))|((( 345 -ACI2 Current 343 +ACI2 344 +Current 346 346 )))|DIDORO*|((( 347 347 Reserve 348 348 )))|MOD ... ... @@ -398,6 +398,8 @@ 398 398 ** DO1 is high in case there is load between DO1 and V+. 399 399 ** DO1 LED is off in both case 400 400 400 + 401 + 401 401 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 402 402 403 403 ... ... @@ -409,9 +409,11 @@ 409 409 Total : 11 bytes payload 410 410 411 411 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 412 -| (% style="background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="background-color:#D9E2F3;color:#0070C0" %)**4**|(% style="background-color:#D9E2F3;color:#0070C0" %)**4**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**413 +|**Size(bytes)**|**4**|**4**|**1**|**1**|**1** 413 413 |Value|COUNT1|COUNT2 |DIDORO*|((( 414 -Reserve 415 +Reserve 416 + 417 + 415 415 )))|MOD 416 416 ))) 417 417 ... ... @@ -485,7 +485,7 @@ 485 485 **LT22222-L**: This mode the DI1 is used as a counting pin. 486 486 487 487 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 488 -| (% style="background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="background-color:#D9E2F3;color:#0070C0" %)**4**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**491 +|**Size(bytes)**|**4**|**2**|**2**|**1**|**1**|**1** 489 489 |Value|COUNT1|((( 490 490 ACI1 Current 491 491 )))|((( ... ... @@ -779,6 +779,7 @@ 779 779 (6) 780 780 ))) 781 781 785 + 782 782 (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below 783 783 784 784 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) ... ... @@ -903,6 +903,8 @@ 903 903 904 904 * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 905 905 910 + 911 + 906 906 === 3.4.1 Common Commands === 907 907 908 908 ... ... @@ -1196,6 +1196,7 @@ 1196 1196 |0x00|DO1 set to high 1197 1197 |0x11|DO1 NO Action 1198 1198 1205 + 1199 1199 (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status: 1200 1200 1201 1201 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) ... ... @@ -1204,6 +1204,7 @@ 1204 1204 |0x00|DO2 set to high 1205 1205 |0x11|DO2 NO Action 1206 1206 1214 + 1207 1207 (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status: 1208 1208 1209 1209 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) ... ... @@ -1212,9 +1212,12 @@ 1212 1212 |0x00|DO3 set to high 1213 1213 |0x11|DO3 NO Action 1214 1214 1215 -(% style="color:#4f81bd" %)**Sixth and Seventh and Eighth and Ninth Byte**:(%%) Latching time. Unit: ms 1216 1216 1224 +(% style="color:#4f81bd" %)**Sixth and Seventh and Eighth and Ninth Byte**: 1217 1217 1226 + Latching time. Unit: ms 1227 + 1228 + 1218 1218 (% style="color:red" %)**Note: ** 1219 1219 1220 1220 Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes ... ... @@ -1542,7 +1542,7 @@ 1542 1542 1543 1543 (% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices. 1544 1544 1545 -(% style="color:blue" %)**Step 4**(%%): Search LT-22222-L(for both LT-22222-L) and add DevEUI.(% style="display:none" %) 1556 +(% style="color:blue" %)**Step 4**(%%): Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %) 1546 1546 1547 1547 Search under The things network 1548 1548 ... ... @@ -1727,6 +1727,7 @@ 1727 1727 1728 1728 **Black: GND** 1729 1729 1741 + 1730 1730 **Connection diagram:** 1731 1731 1732 1732 [[image:1653357640609-758.png]] ... ... @@ -1734,22 +1734,6 @@ 1734 1734 [[image:1653357648330-671.png||height="155" width="733"]] 1735 1735 1736 1736 1737 -Example connected to a regulated power supply to measure voltage 1738 - 1739 -[[image:image-20230608101532-1.png||height="606" width="447"]] 1740 - 1741 -[[image:image-20230608101608-2.jpeg||height="379" width="284"]] 1742 - 1743 -[[image:image-20230608101722-3.png||height="102" width="1139"]] 1744 - 1745 - 1746 -(% style="color:blue; font-weight:bold" %)**Specifications of the regulated power**(%%) (% style="color:blue" %)**:** 1747 - 1748 -(% style="color:red" %)**Red: 12~~24v** 1749 - 1750 -**Black: GND** 1751 - 1752 - 1753 1753 === 3.6.5 Relay Output === 1754 1754 1755 1755 ... ... @@ -1769,7 +1769,7 @@ 1769 1769 1770 1770 1771 1771 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 1772 -|(% style="background-color:#d9e2f3; color:#0070c0; 1768 +|(% style="background-color:#d9e2f3; color:#0070c0;width:50px" %)**LEDs**|(% style="background-color:#d9e2f3; color:#0070c0;width:470px" %)**Feature** 1773 1773 |**PWR**|Always on if there is power 1774 1774 |**SYS**|((( 1775 1775 After device is powered on, the SYS will **fast blink in GREEN** for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be **on GREEN for 5 seconds. **SYS will **blink Blue** on every upload and **blink Green** once receive a downlink message. ... ... @@ -1803,6 +1803,9 @@ 1803 1803 |**RO1**| 1804 1804 |**RO2**| 1805 1805 1802 + 1803 + 1804 + 1806 1806 = 4. Use AT Command = 1807 1807 1808 1808 == 4.1 Access AT Command == ... ... @@ -2418,7 +2418,7 @@ 2418 2418 Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 2419 2419 ))) 2420 2420 * ((( 2421 -Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to Support@dragino.cc>>mailto:Support@dragino.cc]]2420 +Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 2422 2422 2423 2423 2424 2424
- image-20230608101532-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -563.0 KB - Content
- image-20230608101608-2.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -287.8 KB - Content
- image-20230608101722-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -25.4 KB - Content