... ... @@ -26,7 +26,7 @@
26 26  )))
27 27  
28 28  (((
29 -The LT I/O Controllers allows the user to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, building automation, and so on.
29 +The LT I/O Controllers allows the user to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on.
30 30  )))
31 31  
32 32  (((
... ... @@ -189,6 +189,8 @@
189 189  
190 190  * Counting
191 191  
192 +
193 +
192 192  == 1.4  Applications ==
193 193  
194 194  
... ... @@ -204,6 +204,8 @@
204 204  
205 205  * Smart Factory
206 206  
209 +
210 +
207 207  == 1.5 Hardware Variants ==
208 208  
209 209  
... ... @@ -221,6 +221,8 @@
221 221  * 1 x Counting Port
222 222  )))
223 223  
228 +
229 +
224 224  = 2. Power ON Device =
225 225  
226 226  
... ... @@ -277,7 +277,7 @@
277 277  Each LT is shipped with a sticker with the default device EUI as below:
278 278  )))
279 279  
280 -[[image:image-20230425173427-2.png||height="246" width="530"]]
286 +[[image:image-20230425173427-2.png]]
281 281  
282 282  
283 283  Input these keys in the LoRaWAN Server portal. Below is TTN screen shot:
... ... @@ -314,42 +314,23 @@
314 314  * (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
315 315  * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
316 316  
323 +
317 317  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
318 318  
319 319  
320 320  (((
321 -The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. (% style="display:none" %)
322 -
323 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
324 -|Size(bytes)(% style="display:none" %) |2|2|2|2|1|1|1
325 -|Value|(((
326 -AVI1
327 -voltage
328 -)))|(((
329 -AVI2
330 -voltage
331 -)))|(((
332 -ACI1
333 -Current
334 -)))|(((
335 -ACI2
336 -Current
337 -)))|DIDORO*|(((
338 -Reserve
339 -)))|MOD
328 +The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
340 340  )))
341 341  
331 +[[image:image-20220523174024-3.png]]
342 342  
343 343  (((
344 344  
345 345  
346 346  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
347 -
348 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
349 -|bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0
350 -|RO1|RO2|DI3|DI2|DI1|DO3|DO2|DO1
351 351  )))
352 352  
339 +[[image:image-20220523174254-4.png]]
353 353  
354 354  * RO is for relay. ROx=1 : close,ROx=0 always open.
355 355  * DI is for digital input. DIx=1: high or float, DIx=0: low.
... ... @@ -390,6 +390,7 @@
390 390  ** DO1 is high in case there is load between DO1 and V+.
391 391  ** DO1 LED is off in both case
392 392  
380 +
393 393  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
394 394  
395 395  
... ... @@ -399,28 +399,18 @@
399 399  
400 400  (((
401 401  Total : 11 bytes payload
390 +)))
402 402  
403 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
404 -|Size(bytes)|4|4|1|1|1
405 -|Value|COUNT1|COUNT2 |DIDORO*|(((
406 -Reserve
392 +[[image:image-20220523180452-3.png]]
407 407  
408 -
409 -)))|MOD
410 -)))
411 411  
412 412  (((
413 -
414 -
415 415  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below
416 -
417 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
418 -|bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0
419 -|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
420 -
421 -RO is for relay. ROx=1 : close,ROx=0 always open.
422 422  )))
423 423  
399 +[[image:image-20220523180506-4.png]]
400 +
401 +* RO is for relay. ROx=1 : close,ROx=0 always open.
424 424  * FIRST: Indicate this is the first packet after join network.
425 425  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
426 426  
... ... @@ -478,14 +478,6 @@
478 478  
479 479  **LT22222-L**: This mode the DI1 is used as a counting pin.
480 480  
481 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
482 -|Size(bytes)|4|2|2|1|1|1
483 -|Value|COUNT1|(((
484 -ACI1 Current
485 -)))|(((
486 -ACI2 Current
487 -)))|DIDORO*|Reserve|MOD
488 -
489 489  [[image:image-20220523181246-5.png]]
490 490  
491 491  (((
... ... @@ -804,6 +804,7 @@
804 804  
805 805  * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
806 806  
777 +
807 807  === 3.4.1 Common Commands ===
808 808  
809 809  
... ... @@ -1156,7 +1156,7 @@
1156 1156  )))
1157 1157  
1158 1158  (((
1159 -[[image:image-20230426161322-1.png]]
1130 +[[image:image-20220524093724-9.png]]
1160 1160  )))
1161 1161  
1162 1162  (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
... ... @@ -2119,20 +2119,14 @@
2119 2119  [[image:1653360498588-932.png||height="485" width="726"]]
2120 2120  
2121 2121  
2122 -== 6.4 How to change the uplink interval ==
2093 +== 6.4 Can I see counting event in Serial? ==
2123 2123  
2124 2124  
2125 -Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/]]
2126 -
2127 -
2128 -== 6.5 Can I see counting event in Serial? ==
2129 -
2130 -
2131 2131  (((
2132 2132  User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first.
2133 2133  
2134 2134  
2135 -== 6.6 Can i use point to point communication for LT-22222-L? ==
2100 +== 6.5 Can i use point to point communication for LT-22222-L? ==
2136 2136  
2137 2137  
2138 2138  Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]  ,this is [[firmware>>https://github.com/dragino/LT-22222-L/releases]].
... ... @@ -2141,7 +2141,7 @@
2141 2141  )))
2142 2142  
2143 2143  (((
2144 -== 6.7 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
2109 +== 6.Why does the relay output become the default and open relay after the lt22222 is powered off? ==
2145 2145  
2146 2146  
2147 2147  If the device is not shut down, but directly powered off.
... ... @@ -2153,7 +2153,7 @@
2153 2153  After restart, the status before power failure will be read from flash.
2154 2154  
2155 2155  
2156 -== 6.8 Can i set up LT-22222-L as a NC(Normal Close) Relay? ==
2121 +== 6.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? ==
2157 2157  
2158 2158  
2159 2159  LT-22222-L built-in relay is NO (Normal Open). User can use an external relay to achieve Normal Close purpose. Diagram as below:
... ... @@ -2162,7 +2162,7 @@
2162 2162  [[image:image-20221006170630-1.png||height="610" width="945"]]
2163 2163  
2164 2164  
2165 -== 6.9 Can LT22222-L save RO state? ==
2130 +== 6.Can LT22222-L save RO state? ==
2166 2166  
2167 2167  
2168 2168  Firmware version needs to be no less than 1.6.0.
... ... @@ -2225,6 +2225,8 @@
2225 2225  * (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
2226 2226  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2227 2227  
2193 +
2194 +
2228 2228  = 9. Packing Info =
2229 2229  
2230 2230  
... ... @@ -2242,6 +2242,8 @@
2242 2242  * Package Size / pcs : 14.5 x 8 x 5 cm
2243 2243  * Weight / pcs : 170g
2244 2244  
2212 +
2213 +
2245 2245  = 10. Support =
2246 2246  
2247 2247  
... ... @@ -2261,3 +2261,5 @@
2261 2261  * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
2262 2262  * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]]
2263 2263  * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]]
2233 +
2234 +
image-20230426161322-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -15.2 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0