Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -189,6 +189,8 @@ 189 189 190 190 * Counting 191 191 192 + 193 + 192 192 == 1.4 Applications == 193 193 194 194 ... ... @@ -204,6 +204,8 @@ 204 204 205 205 * Smart Factory 206 206 209 + 210 + 207 207 == 1.5 Hardware Variants == 208 208 209 209 ... ... @@ -221,6 +221,8 @@ 221 221 * 1 x Counting Port 222 222 ))) 223 223 228 + 229 + 224 224 = 2. Power ON Device = 225 225 226 226 ... ... @@ -308,12 +308,19 @@ 308 308 There are five working modes + one interrupt mode on LT for different type application: 309 309 310 310 * (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO 317 + 311 311 * (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO 319 + 312 312 * (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO 321 + 313 313 * (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO 323 + 314 314 * (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 325 + 315 315 * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 316 316 328 + 329 + 317 317 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 318 318 319 319 ... ... @@ -321,31 +321,20 @@ 321 321 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. (% style="display:none" %) 322 322 323 323 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 324 -|Size(bytes)(% style="d isplay:none" %)|2|2|2|2|1|1|1337 +|(% style="background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1** 325 325 |Value|((( 326 -AVI1 327 - 328 -voltage 339 +AVI1 voltage 329 329 )))|((( 330 -AVI2 331 - 332 -voltage 341 +AVI2 voltage 333 333 )))|((( 334 -ACI1 335 - 336 -Current 343 +ACI1 Current 337 337 )))|((( 338 -ACI2 339 - 340 -Current 345 +ACI2 Current 341 341 )))|DIDORO*|((( 342 342 Reserve 343 - 344 - 345 345 )))|MOD 346 346 ))) 347 347 348 - 349 349 ((( 350 350 351 351 ... ... @@ -352,7 +352,7 @@ 352 352 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 353 353 354 354 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 355 -|bit7|bit6|bit5|bit4|bit3|bit2|bit1|bit0 357 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 356 356 |RO1|RO2|DI3|DI2|DI1|DO3|DO2|DO1 357 357 ))) 358 358 ... ... @@ -405,18 +405,28 @@ 405 405 406 406 ((( 407 407 Total : 11 bytes payload 408 -))) 409 409 410 -[[image:image-20220523180452-3.png]] 411 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 412 +|**Size(bytes)**|**4**|**4**|**1**|**1**|**1** 413 +|Value|COUNT1|COUNT2 |DIDORO*|((( 414 +Reserve 411 411 416 + 417 +)))|MOD 418 +))) 412 412 413 413 ((( 421 + 422 + 414 414 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 415 -))) 416 416 417 -[[image:image-20220523180506-4.png]] 425 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 426 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 427 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 418 418 419 -* RO is for relay. ROx=1 : close,ROx=0 always open. 429 +RO is for relay. ROx=1 : close,ROx=0 always open. 430 +))) 431 + 420 420 * FIRST: Indicate this is the first packet after join network. 421 421 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 422 422 ... ... @@ -474,15 +474,24 @@ 474 474 475 475 **LT22222-L**: This mode the DI1 is used as a counting pin. 476 476 477 -[[image:image-20220523181246-5.png]] 489 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 490 +|**Size(bytes)**|**4**|**2**|**2**|**1**|**1**|**1** 491 +|Value|COUNT1|((( 492 +ACI1 Current 493 +)))|((( 494 +ACI2 Current 495 +)))|DIDORO*|Reserve|MOD 478 478 479 479 ((( 480 480 481 481 482 482 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 501 + 502 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 503 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 504 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 483 483 ))) 484 484 485 -[[image:image-20220523181301-6.png]] 486 486 487 487 * RO is for relay. ROx=1 : close,ROx=0 always open. 488 488 * FIRST: Indicate this is the first packet after join network. ... ... @@ -524,16 +524,25 @@ 524 524 525 525 ((( 526 526 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. 527 -))) 528 528 529 -[[image:image-20220523181903-8.png]] 549 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 550 +|**Size(bytes)**|**4**|**4**|**1**|**1**|**1** 551 +|Value|COUNT1|AVI1 Counting|DIDORO*|((( 552 +Reserve 530 530 554 + 555 +)))|MOD 556 +))) 531 531 558 + 532 532 ((( 533 533 (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 561 + 562 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 563 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 564 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 534 534 ))) 535 535 536 -[[image:image-20220523181727-7.png]] 537 537 538 538 * RO is for relay. ROx=1 : close,ROx=0 always open. 539 539 * FIRST: Indicate this is the first packet after join network. ... ... @@ -588,12 +588,29 @@ 588 588 589 589 **LT22222-L**: This mode the DI1 is used as a counting pin. 590 590 591 -[[image:image-20220523182334-9.png]] 621 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 622 +|**Size(bytes)**|**2**|**2**|**2**|**2**|**1**|**1**|**1** 623 +|Value|((( 624 +AVI1 625 +voltage 626 +)))|((( 627 +AVI2 628 +voltage 629 +)))|((( 630 +ACI1 631 +Current 632 +)))|COUNT1|DIDORO*|((( 633 +Reserve 634 +)))|MOD 592 592 593 593 ((( 594 594 595 595 596 596 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 640 + 641 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 642 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 643 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 597 597 ))) 598 598 599 599 * RO is for relay. ROx=1 : close,ROx=0 always open. ... ... @@ -718,12 +718,51 @@ 718 718 719 719 MOD6 Payload : total 11 bytes payload 720 720 721 -[[image:image-20220524085923-1.png]] 768 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 769 +|**Size(bytes)**|**1**|**1**|**1**|**6**|**1**|**1** 770 +|Value|((( 771 +TRI_A 772 +FLAG 773 +)))|((( 774 +TRI_A 775 +Status 776 +)))|((( 777 +TRI_DI 778 +FLAG+STA 779 +)))|Reserve|Enable/Disable MOD6|((( 780 +MOD 781 +(6) 782 +))) 722 722 723 - 724 724 (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below 725 725 726 -[[image:image-20220524090106-2.png]] 786 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 787 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 788 +|((( 789 +AV1_ 790 +LOW 791 +)))|((( 792 +AV1_ 793 +HIGH 794 +)))|((( 795 +AV2_ 796 +LOW 797 +)))|((( 798 +AV2_ 799 +HIGH 800 +)))|((( 801 +AC1_ 802 +LOW 803 +)))|((( 804 +AC1_ 805 +HIGH 806 +)))|((( 807 +AC2_ 808 +LOW 809 +)))|((( 810 +AC2_ 811 +HIGH 812 +))) 727 727 728 728 * Each bits shows if the corresponding trigger has been configured. 729 729 ... ... @@ -732,10 +732,35 @@ 732 732 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW 733 733 734 734 735 - 736 736 (% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1byte as below 737 737 738 -[[image:image-20220524090249-3.png]] 823 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 824 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 825 +|((( 826 +AV1_ 827 +LOW 828 +)))|((( 829 +AV1_ 830 +HIGH 831 +)))|((( 832 +AV2_ 833 +LOW 834 +)))|((( 835 +AV2_ 836 +HIGH 837 +)))|((( 838 +AC1_ 839 +LOW 840 +)))|((( 841 +AC1_ 842 +HIGH 843 +)))|((( 844 +AC2_ 845 +LOW 846 +)))|((( 847 +AC2_ 848 +HIGH 849 +))) 739 739 740 740 * Each bits shows which status has been trigger on this uplink. 741 741 ... ... @@ -746,7 +746,9 @@ 746 746 747 747 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 748 748 749 -[[image:image-20220524090456-4.png]] 860 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 861 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 862 +|N/A|N/A|N/A|N/A|DI2_STATUS|DI2_FLAG|DI1_STATUS|DI1_FLAG 750 750 751 751 * Each bits shows which status has been trigger on this uplink. 752 752 ... ... @@ -1034,9 +1034,14 @@ 1034 1034 1035 1035 ((( 1036 1036 01: Low, 00: High , 11: No action 1150 + 1151 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 1152 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Downlink Code**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO3** 1153 +|02 01 00 11|Low|High|No Action 1154 +|02 00 11 01|High|No Action|Low 1155 +|02 11 01 00|No Action|Low|High 1037 1037 ))) 1038 1038 1039 -[[image:image-20220524092754-5.png]] 1040 1040 1041 1041 ((( 1042 1042 (% style="color:red" %)**Note: For LT-22222-L, there is no DO3, the last byte can use any value.** ... ... @@ -1074,24 +1074,31 @@ 1074 1074 1075 1075 (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status: 1076 1076 1077 -[[image:image-20220524093238-6.png]] 1195 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1196 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status** 1197 +|0x01|DO1 set to low 1198 +|0x00|DO1 set to high 1199 +|0x11|DO1 NO Action 1078 1078 1079 - 1080 1080 (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status: 1081 1081 1082 -[[image:image-20220524093328-7.png]] 1203 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1204 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status** 1205 +|0x01|DO2 set to low 1206 +|0x00|DO2 set to high 1207 +|0x11|DO2 NO Action 1083 1083 1084 - 1085 1085 (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status: 1086 1086 1087 -[[image:image-20220524093351-8.png]] 1211 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1212 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status** 1213 +|0x01|DO3 set to low 1214 +|0x00|DO3 set to high 1215 +|0x11|DO3 NO Action 1088 1088 1217 +(% style="color:#4f81bd" %)**Sixth and Seventh and Eighth and Ninth Byte**:(%%) Latching time. Unit: ms 1089 1089 1090 -(% style="color:#4f81bd" %)**Sixth and Seventh and Eighth and Ninth Byte**: 1091 1091 1092 - Latching time. Unit: ms 1093 - 1094 - 1095 1095 (% style="color:red" %)**Note: ** 1096 1096 1097 1097 Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes ... ... @@ -1141,10 +1141,21 @@ 1141 1141 1142 1142 ((( 1143 1143 01: Close , 00: Open , 11: No action 1269 + 1270 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:320px" %) 1271 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Downlink Code**|(% style="background-color:#d9e2f3; color:#0070c0" %)**RO1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**RO2** 1272 +|03 00 11|Open|No Action 1273 +|03 01 11|Close|No Action 1274 +|03 11 00|No Action|Open 1275 +|03 11 01|No Action|Close 1276 +|03 00 00|Open|Open 1277 +|03 01 01|Close|Close 1278 +|03 01 00|Close|Open 1279 +|03 00 01|Open|Close 1144 1144 ))) 1145 1145 1146 1146 ((( 1147 - [[image:image-20230426161322-1.png]]1283 + 1148 1148 ))) 1149 1149 1150 1150 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** ... ... @@ -1408,7 +1408,7 @@ 1408 1408 1409 1409 (% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices. 1410 1410 1411 -(% style="color:blue" %)**Step 4**(%%): Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)1547 +(% style="color:blue" %)**Step 4**(%%): Search LT-22222-L(for both LT-22222-L) and add DevEUI.(% style="display:none" %) 1412 1412 1413 1413 Search under The things network 1414 1414 ... ... @@ -1593,7 +1593,6 @@ 1593 1593 1594 1594 **Black: GND** 1595 1595 1596 - 1597 1597 **Connection diagram:** 1598 1598 1599 1599 [[image:1653357640609-758.png]] ... ... @@ -1601,6 +1601,22 @@ 1601 1601 [[image:1653357648330-671.png||height="155" width="733"]] 1602 1602 1603 1603 1739 +Example connected to a regulated power supply to measure voltage 1740 + 1741 +[[image:image-20230608101532-1.png||height="606" width="447"]] 1742 + 1743 +[[image:image-20230608101608-2.jpeg||height="379" width="284"]] 1744 + 1745 +[[image:image-20230608101722-3.png||height="102" width="1139"]] 1746 + 1747 + 1748 +(% style="color:blue; font-weight:bold" %)**Specifications of the regulated power**(%%) (% style="color:blue" %)**:** 1749 + 1750 +(% style="color:red" %)**Red: 12~~24v** 1751 + 1752 +**Black: GND** 1753 + 1754 + 1604 1604 === 3.6.5 Relay Output === 1605 1605 1606 1606 ... ... @@ -1619,9 +1619,41 @@ 1619 1619 == 3.7 LEDs Indicators == 1620 1620 1621 1621 1622 -[[image:image-20220524100748-11.png]] 1773 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 1774 +|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**LEDs**|(% style="background-color:#d9e2f3; color:#0070c0; width:470px" %)**Feature** 1775 +|**PWR**|Always on if there is power 1776 +|**SYS**|((( 1777 +After device is powered on, the SYS will **fast blink in GREEN** for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be **on GREEN for 5 seconds. **SYS will **blink Blue** on every upload and **blink Green** once receive a downlink message. 1778 +))) 1779 +|**TX**|((( 1780 +((( 1781 +Device boot: TX blinks 5 times. 1782 +))) 1623 1623 1784 +((( 1785 +Successful join network: TX ON for 5 seconds. 1786 +))) 1624 1624 1788 +((( 1789 +Transmit a LoRa packet: TX blinks once 1790 +))) 1791 +))) 1792 +|**RX**|RX blinks once when receive a packet. 1793 +|**DO1**| 1794 +|**DO2**| 1795 +|**DO3**| 1796 +|**DI2**|((( 1797 +For LT-22222-L: ON when DI2 is high, LOW when DI2 is low 1798 +))) 1799 +|**DI2**|((( 1800 +For LT-22222-L: ON when DI2 is high, LOW when DI2 is low 1801 +))) 1802 +|**DI2**|((( 1803 +For LT-22222-L: ON when DI2 is high, LOW when DI2 is low 1804 +))) 1805 +|**RO1**| 1806 +|**RO2**| 1807 + 1625 1625 = 4. Use AT Command = 1626 1626 1627 1627 == 4.1 Access AT Command == ... ... @@ -2237,7 +2237,7 @@ 2237 2237 Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 2238 2238 ))) 2239 2239 * ((( 2240 -Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]2423 +Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]] 2241 2241 2242 2242 2243 2243
- image-20230608101532-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +563.0 KB - Content
- image-20230608101608-2.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +287.8 KB - Content
- image-20230608101722-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.4 KB - Content