From version < 117.2 >
edited by Xiaoling
on 2023/04/26 17:51
To version < 118.14 >
edited by Xiaoling
on 2023/05/17 11:39
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -283,7 +283,7 @@
283 283  Each LT is shipped with a sticker with the default device EUI as below:
284 284  )))
285 285  
286 -[[image:image-20230425173427-2.png]]
286 +[[image:image-20230425173427-2.png||height="246" width="530"]]
287 287  
288 288  
289 289  Input these keys in the LoRaWAN Server portal. Below is TTN screen shot:
... ... @@ -326,18 +326,37 @@
326 326  
327 327  
328 328  (((
329 -The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
329 +The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. (% style="display:none" %)
330 +
331 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
332 +|**Size(bytes)(% style="display:none" %) (%%)**|**2**|**2**|**2**|**2**|**1**|**1**|**1**
333 +|Value|(((
334 +AVI1
335 +voltage
336 +)))|(((
337 +AVI2
338 +voltage
339 +)))|(((
340 +ACI1
341 +Current
342 +)))|(((
343 +ACI2
344 +Current
345 +)))|DIDORO*|(((
346 +Reserve
347 +)))|MOD
330 330  )))
331 331  
332 -[[image:image-20220523174024-3.png]]
333 -
334 334  (((
335 335  
336 336  
337 337  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
354 +
355 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
356 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0**
357 +|RO1|RO2|DI3|DI2|DI1|DO3|DO2|DO1
338 338  )))
339 339  
340 -[[image:image-20220523174254-4.png]]
341 341  
342 342  * RO is for relay. ROx=1 : close,ROx=0 always open.
343 343  * DI is for digital input. DIx=1: high or float, DIx=0: low.
... ... @@ -389,18 +389,28 @@
389 389  
390 390  (((
391 391  Total : 11 bytes payload
392 -)))
393 393  
394 -[[image:image-20220523180452-3.png]]
412 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
413 +|**Size(bytes)**|**4**|**4**|**1**|**1**|**1**
414 +|Value|COUNT1|COUNT2 |DIDORO*|(((
415 +Reserve
395 395  
417 +
418 +)))|MOD
419 +)))
396 396  
397 397  (((
422 +
423 +
398 398  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below
399 -)))
400 400  
401 -[[image:image-20220523180506-4.png]]
426 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
427 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0**
428 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
402 402  
403 -* RO is for relay. ROx=1 : close,ROx=0 always open.
430 +RO is for relay. ROx=1 : close,ROx=0 always open.
431 +)))
432 +
404 404  * FIRST: Indicate this is the first packet after join network.
405 405  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
406 406  
... ... @@ -458,15 +458,24 @@
458 458  
459 459  **LT22222-L**: This mode the DI1 is used as a counting pin.
460 460  
461 -[[image:image-20220523181246-5.png]]
490 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
491 +|**Size(bytes)**|**4**|**2**|**2**|**1**|**1**|**1**
492 +|Value|COUNT1|(((
493 +ACI1 Current
494 +)))|(((
495 +ACI2 Current
496 +)))|DIDORO*|Reserve|MOD
462 462  
463 463  (((
464 464  
465 465  
466 466  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
502 +
503 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
504 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0**
505 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
467 467  )))
468 468  
469 -[[image:image-20220523181301-6.png]]
470 470  
471 471  * RO is for relay. ROx=1 : close,ROx=0 always open.
472 472  * FIRST: Indicate this is the first packet after join network.
... ... @@ -508,16 +508,25 @@
508 508  
509 509  (((
510 510  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
511 -)))
512 512  
513 -[[image:image-20220523181903-8.png]]
550 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
551 +|**Size(bytes)**|**4**|**4**|**1**|**1**|**1**
552 +|Value|COUNT1|AVI1 Counting|DIDORO*|(((
553 +Reserve
514 514  
555 +
556 +)))|MOD
557 +)))
515 515  
559 +
516 516  (((
517 517  (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
562 +
563 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
564 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0**
565 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
518 518  )))
519 519  
520 -[[image:image-20220523181727-7.png]]
521 521  
522 522  * RO is for relay. ROx=1 : close,ROx=0 always open.
523 523  * FIRST: Indicate this is the first packet after join network.
... ... @@ -572,12 +572,29 @@
572 572  
573 573  **LT22222-L**: This mode the DI1 is used as a counting pin.
574 574  
575 -[[image:image-20220523182334-9.png]]
622 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
623 +|**Size(bytes)**|**2**|**2**|**2**|**2**|**1**|**1**|**1**
624 +|Value|(((
625 +AVI1
626 +voltage
627 +)))|(((
628 +AVI2
629 +voltage
630 +)))|(((
631 +ACI1
632 +Current
633 +)))|COUNT1|DIDORO*|(((
634 +Reserve
635 +)))|MOD
576 576  
577 577  (((
578 578  
579 579  
580 580  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
641 +
642 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
643 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0**
644 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1
581 581  )))
582 582  
583 583  * RO is for relay. ROx=1 : close,ROx=0 always open.
... ... @@ -702,12 +702,52 @@
702 702  
703 703  MOD6 Payload : total 11 bytes payload
704 704  
705 -[[image:image-20220524085923-1.png]]
769 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
770 +|**Size(bytes)**|**1**|**1**|**1**|**6**|**1**|**1**
771 +|Value|(((
772 +TRI_A
773 +FLAG
774 +)))|(((
775 +TRI_A
776 +Status
777 +)))|(((
778 +TRI_DI
779 +FLAG+STA
780 +)))|Reserve|Enable/Disable MOD6|(((
781 +MOD
782 +(6)
783 +)))
706 706  
707 707  
708 708  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
709 709  
710 -[[image:image-20220524090106-2.png]]
788 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
789 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0**
790 +|(((
791 +AV1_
792 +LOW
793 +)))|(((
794 +AV1_
795 +HIGH
796 +)))|(((
797 +AV2_
798 +LOW
799 +)))|(((
800 +AV2_
801 +HIGH
802 +)))|(((
803 +AC1_
804 +LOW
805 +)))|(((
806 +AC1_
807 +HIGH
808 +)))|(((
809 +AC2_
810 +LOW
811 +)))|(((
812 +AC2_
813 +HIGH
814 +)))
711 711  
712 712  * Each bits shows if the corresponding trigger has been configured.
713 713  
... ... @@ -716,10 +716,35 @@
716 716  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
717 717  
718 718  
719 -
720 720  (% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1byte as below
721 721  
722 -[[image:image-20220524090249-3.png]]
825 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
826 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0**
827 +|(((
828 +AV1_
829 +LOW
830 +)))|(((
831 +AV1_
832 +HIGH
833 +)))|(((
834 +AV2_
835 +LOW
836 +)))|(((
837 +AV2_
838 +HIGH
839 +)))|(((
840 +AC1_
841 +LOW
842 +)))|(((
843 +AC1_
844 +HIGH
845 +)))|(((
846 +AC2_
847 +LOW
848 +)))|(((
849 +AC2_
850 +HIGH
851 +)))
723 723  
724 724  * Each bits shows which status has been trigger on this uplink.
725 725  
... ... @@ -730,7 +730,9 @@
730 730  
731 731  (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below
732 732  
733 -[[image:image-20220524090456-4.png]]
862 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
863 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0**
864 +|N/A|N/A|N/A|N/A|DI2_STATUS|DI2_FLAG|DI1_STATUS|DI1_FLAG
734 734  
735 735  * Each bits shows which status has been trigger on this uplink.
736 736  
... ... @@ -1020,9 +1020,14 @@
1020 1020  
1021 1021  (((
1022 1022  01: Low,  00: High ,  11: No action
1154 +
1155 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
1156 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Downlink Code**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO3**
1157 +|02  01  00  11|Low|High|No Action
1158 +|02  00  11  01|High|No Action|Low
1159 +|02  11  01  00|No Action|Low|High
1023 1023  )))
1024 1024  
1025 -[[image:image-20220524092754-5.png]]
1026 1026  
1027 1027  (((
1028 1028  (% style="color:red" %)**Note: For LT-22222-L, there is no DO3, the last byte can use any value.**
... ... @@ -1060,17 +1060,29 @@
1060 1060  
1061 1061  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1062 1062  
1063 -[[image:image-20220524093238-6.png]]
1199 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %)
1200 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status**
1201 +|0x01|DO1 set to low
1202 +|0x00|DO1 set to high
1203 +|0x11|DO1 NO Action
1064 1064  
1065 1065  
1066 1066  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1067 1067  
1068 -[[image:image-20220524093328-7.png]]
1208 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %)
1209 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status**
1210 +|0x01|DO2 set to low
1211 +|0x00|DO2 set to high
1212 +|0x11|DO2 NO Action
1069 1069  
1070 1070  
1071 1071  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1072 1072  
1073 -[[image:image-20220524093351-8.png]]
1217 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %)
1218 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status**
1219 +|0x01|DO3 set to low
1220 +|0x00|DO3 set to high
1221 +|0x11|DO3 NO Action
1074 1074  
1075 1075  
1076 1076  (% style="color:#4f81bd" %)**Sixth and Seventh and Eighth and Ninth Byte**:
... ... @@ -1127,10 +1127,21 @@
1127 1127  
1128 1128  (((
1129 1129  01: Close ,  00: Open , 11: No action
1278 +
1279 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:320px" %)
1280 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Downlink Code**|(% style="background-color:#d9e2f3; color:#0070c0" %)**RO1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**RO2**
1281 +|03  00  11|Open|No Action
1282 +|03  01  11|Close|No Action
1283 +|03  11  00|No Action|Open
1284 +|03  11  01|No Action|Close
1285 +|03  00  00|Open|Open
1286 +|03  01  01|Close|Close
1287 +|03  01  00|Close|Open
1288 +|03  00  01|Open|Close
1130 1130  )))
1131 1131  
1132 1132  (((
1133 -[[image:image-20230426161322-1.png]]
1292 +
1134 1134  )))
1135 1135  
1136 1136  (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
... ... @@ -1605,9 +1605,44 @@
1605 1605  == 3.7 LEDs Indicators ==
1606 1606  
1607 1607  
1608 -[[image:image-20220524100748-11.png]]
1767 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %)
1768 +|(% style="background-color:#d9e2f3; color:#0070c0;width:50px" %)**LEDs**|(% style="background-color:#d9e2f3; color:#0070c0;width:470px" %)**Feature**
1769 +|**PWR**|Always on if there is power
1770 +|**SYS**|(((
1771 +After device is powered on, the SYS will **fast blink in GREEN** for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be **on GREEN for 5 seconds. **SYS will **blink Blue** on every upload and **blink Green** once receive a downlink message.
1772 +)))
1773 +|**TX**|(((
1774 +(((
1775 +Device boot: TX blinks 5 times.
1776 +)))
1609 1609  
1778 +(((
1779 +Successful join network: TX ON for 5 seconds.
1780 +)))
1610 1610  
1782 +(((
1783 +Transmit a LoRa packet: TX blinks once
1784 +)))
1785 +)))
1786 +|**RX**|RX blinks once when receive a packet.
1787 +|**DO1**|
1788 +|**DO2**|
1789 +|**DO3**|
1790 +|**DI2**|(((
1791 +For LT-22222-L: ON when DI2 is high, LOW when DI2 is low
1792 +)))
1793 +|**DI2**|(((
1794 +For LT-22222-L: ON when DI2 is high, LOW when DI2 is low
1795 +)))
1796 +|**DI2**|(((
1797 +For LT-22222-L: ON when DI2 is high, LOW when DI2 is low
1798 +)))
1799 +|**RO1**|
1800 +|**RO2**|
1801 +
1802 +
1803 +
1804 +
1611 1611  = 4. Use AT Command =
1612 1612  
1613 1613  == 4.1 Access AT Command ==
... ... @@ -2093,14 +2093,20 @@
2093 2093  [[image:1653360498588-932.png||height="485" width="726"]]
2094 2094  
2095 2095  
2096 -== 6.4 Can I see counting event in Serial? ==
2290 +== 6.4 How to change the uplink interval ==
2097 2097  
2098 2098  
2293 +Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/]]
2294 +
2295 +
2296 +== 6.5 Can I see counting event in Serial? ==
2297 +
2298 +
2099 2099  (((
2100 2100  User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first.
2101 2101  
2102 2102  
2103 -== 6.5 Can i use point to point communication for LT-22222-L? ==
2303 +== 6.6 Can i use point to point communication for LT-22222-L? ==
2104 2104  
2105 2105  
2106 2106  Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]  ,this is [[firmware>>https://github.com/dragino/LT-22222-L/releases]].
... ... @@ -2109,7 +2109,7 @@
2109 2109  )))
2110 2110  
2111 2111  (((
2112 -== 6.Why does the relay output become the default and open relay after the lt22222 is powered off? ==
2312 +== 6.7 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
2113 2113  
2114 2114  
2115 2115  If the device is not shut down, but directly powered off.
... ... @@ -2121,7 +2121,7 @@
2121 2121  After restart, the status before power failure will be read from flash.
2122 2122  
2123 2123  
2124 -== 6.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? ==
2324 +== 6.8 Can i set up LT-22222-L as a NC(Normal Close) Relay? ==
2125 2125  
2126 2126  
2127 2127  LT-22222-L built-in relay is NO (Normal Open). User can use an external relay to achieve Normal Close purpose. Diagram as below:
... ... @@ -2130,7 +2130,7 @@
2130 2130  [[image:image-20221006170630-1.png||height="610" width="945"]]
2131 2131  
2132 2132  
2133 -== 6.Can LT22222-L save RO state? ==
2333 +== 6.9 Can LT22222-L save RO state? ==
2134 2134  
2135 2135  
2136 2136  Firmware version needs to be no less than 1.6.0.
... ... @@ -2193,8 +2193,6 @@
2193 2193  * (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
2194 2194  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2195 2195  
2196 -
2197 -
2198 2198  = 9. Packing Info =
2199 2199  
2200 2200  
... ... @@ -2212,8 +2212,6 @@
2212 2212  * Package Size / pcs : 14.5 x 8 x 5 cm
2213 2213  * Weight / pcs : 170g
2214 2214  
2215 -
2216 -
2217 2217  = 10. Support =
2218 2218  
2219 2219  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0