Last modified by Mengting Qiu on 2025/06/04 18:42

From version 117.2
edited by Xiaoling
on 2023/04/26 17:51
Change comment: There is no comment for this version
To version 117.1
edited by Bei Jinggeng
on 2023/04/26 16:20
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Bei
Content
... ... @@ -26,7 +26,7 @@
26 26  )))
27 27  
28 28  (((
29 -The LT I/O Controllers allows the user to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, building automation, and so on.
29 +The LT I/O Controllers allows the user to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on.
30 30  )))
31 31  
32 32  (((
... ... @@ -190,7 +190,6 @@
190 190  * Counting
191 191  
192 192  
193 -
194 194  == 1.4  Applications ==
195 195  
196 196  
... ... @@ -207,7 +207,6 @@
207 207  * Smart Factory
208 208  
209 209  
210 -
211 211  == 1.5 Hardware Variants ==
212 212  
213 213  
... ... @@ -226,7 +226,6 @@
226 226  )))
227 227  
228 228  
229 -
230 230  = 2. Power ON Device =
231 231  
232 232  
... ... @@ -320,8 +320,6 @@
320 320  * (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
321 321  * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
322 322  
323 -
324 -
325 325  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
326 326  
327 327  
... ... @@ -378,8 +378,6 @@
378 378  ** DO1 is high in case there is load between DO1 and V+.
379 379  ** DO1 LED is off in both case
380 380  
381 -
382 -
383 383  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
384 384  
385 385  
... ... @@ -776,8 +776,6 @@
776 776  
777 777  * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
778 778  
779 -
780 -
781 781  === 3.4.1 Common Commands ===
782 782  
783 783  
... ... @@ -2194,7 +2194,6 @@
2194 2194  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2195 2195  
2196 2196  
2197 -
2198 2198  = 9. Packing Info =
2199 2199  
2200 2200  
... ... @@ -2213,7 +2213,6 @@
2213 2213  * Weight / pcs : 170g
2214 2214  
2215 2215  
2216 -
2217 2217  = 10. Support =
2218 2218  
2219 2219  
... ... @@ -2233,3 +2233,4 @@
2233 2233  * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
2234 2234  * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]]
2235 2235  * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]]
2225 +