Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -15,6 +15,7 @@ 15 15 16 16 = 1.Introduction = 17 17 18 + 18 18 == 1.1 What is LT Series I/O Controller == 19 19 20 20 ((( ... ... @@ -26,7 +26,7 @@ 26 26 ))) 27 27 28 28 ((( 29 -The LT I/O Controllers allows the user to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, building automation, and so on. 30 +The LT I/O Controllers allows the user to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on. 30 30 ))) 31 31 32 32 ((( ... ... @@ -53,6 +53,7 @@ 53 53 54 54 ))) 55 55 57 + 56 56 == 1.2 Specifications == 57 57 58 58 ((( ... ... @@ -169,6 +169,7 @@ 169 169 Packet engine up to 256 bytes with CRC. 170 170 171 171 174 + 172 172 173 173 ))) 174 174 ... ... @@ -176,47 +176,31 @@ 176 176 177 177 178 178 * LoRaWAN Class A & Class C protocol 179 - 180 180 * Optional Customized LoRa Protocol 181 - 182 182 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865/MA869 183 - 184 184 * AT Commands to change parameters 185 - 186 186 * Remote configure parameters via LoRa Downlink 187 - 188 188 * Firmware upgradable via program port 189 - 190 190 * Counting 191 191 192 192 193 - 194 194 == 1.4 Applications == 195 195 196 196 197 197 * Smart Buildings & Home Automation 198 - 199 199 * Logistics and Supply Chain Management 200 - 201 201 * Smart Metering 202 - 203 203 * Smart Agriculture 204 - 205 205 * Smart Cities 206 - 207 207 * Smart Factory 208 208 209 209 210 - 211 211 == 1.5 Hardware Variants == 212 212 213 213 214 -(% border="1" style="background-color:#f2f2f2; width:500px" %) 215 -|(% style="background-color:#d9e2f3; color:#0070c0; width:103px" %)**Model**|(% style="background-color:#d9e2f3; color:#0070c0; width:131px" %)**Photo**|(% style="background-color:#d9e2f3; color:#0070c0; width:334px" %)**Description** 216 -|(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)((( 217 -(% style="text-align:center" %) 218 -[[image:image-20230424115112-1.png||height="106" width="58"]] 219 -)))|(% style="width:334px" %)((( 204 +(% border="1" style="background-color:#f7faff; width:500px" %) 205 +|(% style="width:103px" %)**Model**|(% style="width:131px" %)**Photo**|(% style="width:334px" %)**Description** 206 +|(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)[[image:1653296302983-697.png]]|(% style="width:334px" %)((( 220 220 * 2 x Digital Input (Bi-direction) 221 221 * 2 x Digital Output 222 222 * 2 x Relay Output (5A@250VAC / 30VDC) ... ... @@ -226,7 +226,6 @@ 226 226 ))) 227 227 228 228 229 - 230 230 = 2. Power ON Device = 231 231 232 232 ... ... @@ -283,7 +283,7 @@ 283 283 Each LT is shipped with a sticker with the default device EUI as below: 284 284 ))) 285 285 286 -[[image: image-20230425173427-2.png]]272 +[[image:1653297924498-393.png]] 287 287 288 288 289 289 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: ... ... @@ -308,6 +308,7 @@ 308 308 [[image:1653298044601-602.png||height="405" width="709"]] 309 309 310 310 297 + 311 311 == 3.3 Uplink Payload == 312 312 313 313 ... ... @@ -321,7 +321,6 @@ 321 321 * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 322 322 323 323 324 - 325 325 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 326 326 327 327 ... ... @@ -379,7 +379,6 @@ 379 379 ** DO1 LED is off in both case 380 380 381 381 382 - 383 383 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 384 384 385 385 ... ... @@ -668,6 +668,7 @@ 668 668 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 669 669 670 670 656 + 671 671 (% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 672 672 673 673 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** ... ... @@ -728,6 +728,7 @@ 728 728 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. 729 729 730 730 717 + 731 731 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 732 732 733 733 [[image:image-20220524090456-4.png]] ... ... @@ -741,6 +741,7 @@ 741 741 00000101: Means both DI1 and DI2 trigger are enabled. 742 742 743 743 731 + 744 744 (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable. 745 745 746 746 Downlink command to poll MOD6 status: ... ... @@ -777,7 +777,6 @@ 777 777 * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 778 778 779 779 780 - 781 781 === 3.4.1 Common Commands === 782 782 783 783 ... ... @@ -863,6 +863,7 @@ 863 863 864 864 865 865 853 + 866 866 ==== 3.4.2.5 Poll trigger settings ==== 867 867 868 868 ... ... @@ -1077,9 +1077,8 @@ 1077 1077 1078 1078 Latching time. Unit: ms 1079 1079 1068 +Note: 1080 1080 1081 -(% style="color:red" %)**Note: ** 1082 - 1083 1083 Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1084 1084 1085 1085 Before Firmwre v1.6.0 the latch time only suport 2 bytes. ... ... @@ -1108,7 +1108,7 @@ 1108 1108 1109 1109 1110 1110 1111 -==== 3.4.2. 1098 +==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1112 1112 1113 1113 1114 1114 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1130,7 +1130,7 @@ 1130 1130 ))) 1131 1131 1132 1132 ((( 1133 -[[image:image-202 30426161322-1.png]]1120 +[[image:image-20220524093724-9.png]] 1134 1134 ))) 1135 1135 1136 1136 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** ... ... @@ -1137,6 +1137,7 @@ 1137 1137 1138 1138 1139 1139 1127 + 1140 1140 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1141 1141 1142 1142 ... ... @@ -1168,9 +1168,8 @@ 1168 1168 1169 1169 (% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms 1170 1170 1159 +Note: 1171 1171 1172 -(% style="color:red" %)**Note:** 1173 - 1174 1174 Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1175 1175 1176 1176 Before Firmwre v1.6.0 the latch time only suport 2 bytes. ... ... @@ -1181,7 +1181,7 @@ 1181 1181 1182 1182 **Example payload:** 1183 1183 1184 -**~1. 05 01 11 07 D 0**1171 +**~1. 05 01 11 07 D** 1185 1185 1186 1186 Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state. 1187 1187 ... ... @@ -1316,6 +1316,7 @@ 1316 1316 1317 1317 1318 1318 1306 + 1319 1319 ==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ==== 1320 1320 1321 1321 ... ... @@ -1332,6 +1332,7 @@ 1332 1332 1333 1333 1334 1334 1323 + 1335 1335 ==== 3.4.2.25 Copy downlink to uplink ==== 1336 1336 1337 1337 ... ... @@ -1485,6 +1485,8 @@ 1485 1485 1486 1486 ((( 1487 1487 1477 + 1478 + 1488 1488 ))) 1489 1489 1490 1490 ((( ... ... @@ -1516,6 +1516,8 @@ 1516 1516 1517 1517 ((( 1518 1518 1510 + 1511 + 1519 1519 ))) 1520 1520 1521 1521 ((( ... ... @@ -1549,9 +1549,9 @@ 1549 1549 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1550 1550 1551 1551 1552 - (% style="color:blue" %)**NPN output**(%%): GND or Float. Max voltage can apply to output pin is 36v.1545 +**NPN output**: GND or Float. Max voltage can apply to output pin is 36v. 1553 1553 1554 - (% style="color:red" %)**Note: DO pins go to float when device is power off.**1547 +Note: DO pins go to float when device is power off. 1555 1555 1556 1556 [[image:1653357531600-905.png]] 1557 1557 ... ... @@ -1573,9 +1573,9 @@ 1573 1573 1574 1574 (% style="color:blue" %)**Specifications of the wind speed sensor:** 1575 1575 1576 - (% style="color:red" %)**Red: 12~~24v**1569 +**Red: 12~~24v** 1577 1577 1578 - (% style="color:#ffc000" %)**Yellow: 4~~20mA**1571 +**Yellow: 4~~20mA** 1579 1579 1580 1580 **Black: GND** 1581 1581 ... ... @@ -1608,6 +1608,7 @@ 1608 1608 [[image:image-20220524100748-11.png]] 1609 1609 1610 1610 1604 + 1611 1611 = 4. Use AT Command = 1612 1612 1613 1613 == 4.1 Access AT Command == ... ... @@ -1938,7 +1938,7 @@ 1938 1938 **3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php? 1939 1939 dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.** 1940 1940 1941 -**4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 .**1935 +**4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5** 1942 1942 1943 1943 1944 1944 ))) ... ... @@ -1951,6 +1951,7 @@ 1951 1951 1952 1952 ))) 1953 1953 1948 + 1954 1954 === 4.2.3 Change to Class A === 1955 1955 1956 1956 ... ... @@ -1962,19 +1962,11 @@ 1962 1962 ))) 1963 1963 1964 1964 1965 -= 5. CaseStudy=1960 += 5. FAQ = 1966 1966 1967 -== 5.1 Counting howmany objectspassinFlow Line ==1962 +== 5.1 How to upgrade the image? == 1968 1968 1969 1969 1970 -Reference Link: [[How to set up to count objects pass in flow line>>How to set up to count objects pass in flow line]]? 1971 - 1972 - 1973 -= 6. FAQ = 1974 - 1975 -== 6.1 How to upgrade the image? == 1976 - 1977 - 1978 1978 The LT LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to LT to: 1979 1979 1980 1980 * Support new features ... ... @@ -2002,10 +2002,8 @@ 2002 2002 2003 2003 [[image:image-20220524103407-12.png]] 2004 2004 2005 - 2006 2006 [[image:image-20220524103429-13.png]] 2007 2007 2008 - 2009 2009 [[image:image-20220524104033-15.png]] 2010 2010 2011 2011 ... ... @@ -2017,7 +2017,7 @@ 2017 2017 2018 2018 ((( 2019 2019 ((( 2020 -== 6.2 How to change the LoRa Frequency Bands/Region? ==2005 +== 5.2 How to change the LoRa Frequency Bands/Region? == 2021 2021 2022 2022 2023 2023 ))) ... ... @@ -2030,7 +2030,7 @@ 2030 2030 ((( 2031 2031 2032 2032 2033 -== 6.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? ==2018 +== 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 2034 2034 2035 2035 2036 2036 ))) ... ... @@ -2093,7 +2093,7 @@ 2093 2093 [[image:1653360498588-932.png||height="485" width="726"]] 2094 2094 2095 2095 2096 -== 6.4 Can I see counting event in Serial? ==2081 +== 5.4 Can I see counting event in Serial? == 2097 2097 2098 2098 2099 2099 ((( ... ... @@ -2100,7 +2100,7 @@ 2100 2100 User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 2101 2101 2102 2102 2103 -== 6.5 Can i use point to point communication for LT-22222-L? ==2088 +== 5.5 Can i use point to point communication for LT-22222-L? == 2104 2104 2105 2105 2106 2106 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https://github.com/dragino/LT-22222-L/releases]]. ... ... @@ -2109,7 +2109,7 @@ 2109 2109 ))) 2110 2110 2111 2111 ((( 2112 -== 6.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==2097 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 2113 2113 2114 2114 2115 2115 If the device is not shut down, but directly powered off. ... ... @@ -2121,7 +2121,7 @@ 2121 2121 After restart, the status before power failure will be read from flash. 2122 2122 2123 2123 2124 -== 6.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? ==2109 +== 5.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? == 2125 2125 2126 2126 2127 2127 LT-22222-L built-in relay is NO (Normal Open). User can use an external relay to achieve Normal Close purpose. Diagram as below: ... ... @@ -2130,18 +2130,18 @@ 2130 2130 [[image:image-20221006170630-1.png||height="610" width="945"]] 2131 2131 2132 2132 2133 -== 6.8 Can LT22222-L save RO state? ==2118 +== 5.8 Can LT22222-L save RO state? == 2134 2134 2135 2135 2136 2136 Firmware version needs to be no less than 1.6.0. 2137 2137 2138 2138 2139 -= 7. Trouble Shooting =2124 += 6. Trouble Shooting = 2140 2140 ))) 2141 2141 2142 2142 ((( 2143 2143 ((( 2144 -== 7.1 Downlink doesn't work, how to solve it? ==2129 +== 6.1 Downlink doesn't work, how to solve it? == 2145 2145 2146 2146 2147 2147 ))) ... ... @@ -2154,7 +2154,7 @@ 2154 2154 ((( 2155 2155 2156 2156 2157 -== 7.2 Have trouble to upload image. ==2142 +== 6.2 Have trouble to upload image. == 2158 2158 2159 2159 2160 2160 ))) ... ... @@ -2166,7 +2166,7 @@ 2166 2166 ((( 2167 2167 2168 2168 2169 -== 7.3 Why I can't join TTN in US915 /AU915 bands? ==2154 +== 6.3 Why I can't join TTN in US915 /AU915 bands? == 2170 2170 2171 2171 2172 2172 ))) ... ... @@ -2176,7 +2176,7 @@ 2176 2176 ))) 2177 2177 2178 2178 2179 -= 8. Order Info =2164 += 7. Order Info = 2180 2180 2181 2181 2182 2182 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** ... ... @@ -2194,10 +2194,9 @@ 2194 2194 * (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 2195 2195 2196 2196 2182 += 8. Packing Info = 2197 2197 2198 -= 9. Packing Info = 2199 2199 2200 - 2201 2201 **Package Includes**: 2202 2202 2203 2203 * LT-22222-L I/O Controller x 1 ... ... @@ -2213,10 +2213,9 @@ 2213 2213 * Weight / pcs : 170g 2214 2214 2215 2215 2200 += 9. Support = 2216 2216 2217 -= 10. Support = 2218 2218 2219 - 2220 2220 * ((( 2221 2221 Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 2222 2222 ))) ... ... @@ -2227,7 +2227,7 @@ 2227 2227 2228 2228 ))) 2229 2229 2230 -= 1 1. Reference =2213 += 10. Reference = 2231 2231 2232 2232 2233 2233 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
- image-20230424115112-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -27.1 KB - Content
- image-20230425173351-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -207.8 KB - Content
- image-20230425173427-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -150.1 KB - Content
- image-20230426161322-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -15.2 KB - Content