Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -15,6 +15,7 @@ 15 15 16 16 = 1.Introduction = 17 17 18 + 18 18 == 1.1 What is LT Series I/O Controller == 19 19 20 20 ((( ... ... @@ -53,6 +53,7 @@ 53 53 54 54 ))) 55 55 57 + 56 56 == 1.2 Specifications == 57 57 58 58 ((( ... ... @@ -169,6 +169,7 @@ 169 169 Packet engine up to 256 bytes with CRC. 170 170 171 171 174 + 172 172 173 173 ))) 174 174 ... ... @@ -176,17 +176,11 @@ 176 176 177 177 178 178 * LoRaWAN Class A & Class C protocol 179 - 180 180 * Optional Customized LoRa Protocol 181 - 182 182 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865/MA869 183 - 184 184 * AT Commands to change parameters 185 - 186 186 * Remote configure parameters via LoRa Downlink 187 - 188 188 * Firmware upgradable via program port 189 - 190 190 * Counting 191 191 192 192 ... ... @@ -194,15 +194,10 @@ 194 194 195 195 196 196 * Smart Buildings & Home Automation 197 - 198 198 * Logistics and Supply Chain Management 199 - 200 200 * Smart Metering 201 - 202 202 * Smart Agriculture 203 - 204 204 * Smart Cities 205 - 206 206 * Smart Factory 207 207 208 208 ... ... @@ -209,8 +209,8 @@ 209 209 == 1.5 Hardware Variants == 210 210 211 211 212 -(% border="1" style="background-color:#f 2f2f2; width:500px" %)213 -|(% style="width:103px ;background-color:#D9E2F3;color:#0070C0" %)**Model**|(% style="width:131px;background-color:#D9E2F3;color:#0070C0" %)**Photo**|(% style="width:334px;background-color:#D9E2F3;color:#0070C0" %)**Description**204 +(% border="1" style="background-color:#f7faff; width:500px" %) 205 +|(% style="width:103px" %)**Model**|(% style="width:131px" %)**Photo**|(% style="width:334px" %)**Description** 214 214 |(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)[[image:1653296302983-697.png]]|(% style="width:334px" %)((( 215 215 * 2 x Digital Input (Bi-direction) 216 216 * 2 x Digital Output ... ... @@ -302,6 +302,7 @@ 302 302 [[image:1653298044601-602.png||height="405" width="709"]] 303 303 304 304 297 + 305 305 == 3.3 Uplink Payload == 306 306 307 307 ... ... @@ -371,6 +371,7 @@ 371 371 ** DO1 is high in case there is load between DO1 and V+. 372 372 ** DO1 LED is off in both case 373 373 367 + 374 374 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 375 375 376 376 ... ... @@ -659,6 +659,7 @@ 659 659 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 660 660 661 661 656 + 662 662 (% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 663 663 664 664 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** ... ... @@ -719,6 +719,7 @@ 719 719 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. 720 720 721 721 717 + 722 722 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 723 723 724 724 [[image:image-20220524090456-4.png]] ... ... @@ -732,6 +732,7 @@ 732 732 00000101: Means both DI1 and DI2 trigger are enabled. 733 733 734 734 731 + 735 735 (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable. 736 736 737 737 Downlink command to poll MOD6 status: ... ... @@ -778,7 +778,6 @@ 778 778 779 779 === 3.4.2 Sensor related commands === 780 780 781 - 782 782 ==== 3.4.2.1 Set Transmit Interval ==== 783 783 784 784 ... ... @@ -854,6 +854,7 @@ 854 854 855 855 856 856 853 + 857 857 ==== 3.4.2.5 Poll trigger settings ==== 858 858 859 859 ... ... @@ -1068,9 +1068,8 @@ 1068 1068 1069 1069 Latching time. Unit: ms 1070 1070 1068 +Note: 1071 1071 1072 -(% style="color:red" %)**Note: ** 1073 - 1074 1074 Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1075 1075 1076 1076 Before Firmwre v1.6.0 the latch time only suport 2 bytes. ... ... @@ -1099,7 +1099,7 @@ 1099 1099 1100 1100 1101 1101 1102 -==== 3.4.2. 1098 +==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1103 1103 1104 1104 1105 1105 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1128,6 +1128,7 @@ 1128 1128 1129 1129 1130 1130 1127 + 1131 1131 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1132 1132 1133 1133 ... ... @@ -1159,9 +1159,8 @@ 1159 1159 1160 1160 (% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms 1161 1161 1159 +Note: 1162 1162 1163 -(% style="color:red" %)**Note:** 1164 - 1165 1165 Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1166 1166 1167 1167 Before Firmwre v1.6.0 the latch time only suport 2 bytes. ... ... @@ -1172,7 +1172,7 @@ 1172 1172 1173 1173 **Example payload:** 1174 1174 1175 -**~1. 05 01 11 07 D 0**1171 +**~1. 05 01 11 07 D** 1176 1176 1177 1177 Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state. 1178 1178 ... ... @@ -1307,6 +1307,7 @@ 1307 1307 1308 1308 1309 1309 1306 + 1310 1310 ==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ==== 1311 1311 1312 1312 ... ... @@ -1323,6 +1323,7 @@ 1323 1323 1324 1324 1325 1325 1323 + 1326 1326 ==== 3.4.2.25 Copy downlink to uplink ==== 1327 1327 1328 1328 ... ... @@ -1476,6 +1476,8 @@ 1476 1476 1477 1477 ((( 1478 1478 1477 + 1478 + 1479 1479 ))) 1480 1480 1481 1481 ((( ... ... @@ -1507,6 +1507,8 @@ 1507 1507 1508 1508 ((( 1509 1509 1510 + 1511 + 1510 1510 ))) 1511 1511 1512 1512 ((( ... ... @@ -1540,9 +1540,9 @@ 1540 1540 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1541 1541 1542 1542 1543 - (% style="color:blue" %)**NPN output**(%%): GND or Float. Max voltage can apply to output pin is 36v.1545 +**NPN output**: GND or Float. Max voltage can apply to output pin is 36v. 1544 1544 1545 - (% style="color:red" %)**Note: DO pins go to float when device is power off.**1547 +Note: DO pins go to float when device is power off. 1546 1546 1547 1547 [[image:1653357531600-905.png]] 1548 1548 ... ... @@ -1564,9 +1564,9 @@ 1564 1564 1565 1565 (% style="color:blue" %)**Specifications of the wind speed sensor:** 1566 1566 1567 - (% style="color:red" %)**Red: 12~~24v**1569 +**Red: 12~~24v** 1568 1568 1569 - (% style="color:#ffc000" %)**Yellow: 4~~20mA**1571 +**Yellow: 4~~20mA** 1570 1570 1571 1571 **Black: GND** 1572 1572 ... ... @@ -1599,6 +1599,7 @@ 1599 1599 [[image:image-20220524100748-11.png]] 1600 1600 1601 1601 1604 + 1602 1602 = 4. Use AT Command = 1603 1603 1604 1604 == 4.1 Access AT Command == ... ... @@ -1929,7 +1929,7 @@ 1929 1929 **3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php? 1930 1930 dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.** 1931 1931 1932 -**4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 .**1935 +**4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5** 1933 1933 1934 1934 1935 1935 ))) ... ... @@ -1942,6 +1942,7 @@ 1942 1942 1943 1943 ))) 1944 1944 1948 + 1945 1945 === 4.2.3 Change to Class A === 1946 1946 1947 1947 ... ... @@ -1953,19 +1953,11 @@ 1953 1953 ))) 1954 1954 1955 1955 1956 -= 5. CaseStudy=1960 += 5. FAQ = 1957 1957 1958 -== 5.1 Counting howmany objectspassinFlow Line ==1962 +== 5.1 How to upgrade the image? == 1959 1959 1960 1960 1961 -Reference Link: [[How to set up to count objects pass in flow line>>How to set up to count objects pass in flow line]]? 1962 - 1963 - 1964 -= 6. FAQ = 1965 - 1966 -== 6.1 How to upgrade the image? == 1967 - 1968 - 1969 1969 The LT LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to LT to: 1970 1970 1971 1971 * Support new features ... ... @@ -1993,10 +1993,8 @@ 1993 1993 1994 1994 [[image:image-20220524103407-12.png]] 1995 1995 1996 - 1997 1997 [[image:image-20220524103429-13.png]] 1998 1998 1999 - 2000 2000 [[image:image-20220524104033-15.png]] 2001 2001 2002 2002 ... ... @@ -2008,7 +2008,7 @@ 2008 2008 2009 2009 ((( 2010 2010 ((( 2011 -== 6.2 How to change the LoRa Frequency Bands/Region? ==2005 +== 5.2 How to change the LoRa Frequency Bands/Region? == 2012 2012 2013 2013 2014 2014 ))) ... ... @@ -2021,7 +2021,7 @@ 2021 2021 ((( 2022 2022 2023 2023 2024 -== 6.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? ==2018 +== 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 2025 2025 2026 2026 2027 2027 ))) ... ... @@ -2084,7 +2084,7 @@ 2084 2084 [[image:1653360498588-932.png||height="485" width="726"]] 2085 2085 2086 2086 2087 -== 6.4 Can I see counting event in Serial? ==2081 +== 5.4 Can I see counting event in Serial? == 2088 2088 2089 2089 2090 2090 ((( ... ... @@ -2091,7 +2091,7 @@ 2091 2091 User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 2092 2092 2093 2093 2094 -== 6.5 Can i use point to point communication for LT-22222-L? ==2088 +== 5.5 Can i use point to point communication for LT-22222-L? == 2095 2095 2096 2096 2097 2097 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https://github.com/dragino/LT-22222-L/releases]]. ... ... @@ -2100,7 +2100,7 @@ 2100 2100 ))) 2101 2101 2102 2102 ((( 2103 -== 6.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==2097 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 2104 2104 2105 2105 2106 2106 If the device is not shut down, but directly powered off. ... ... @@ -2112,7 +2112,7 @@ 2112 2112 After restart, the status before power failure will be read from flash. 2113 2113 2114 2114 2115 -== 6.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? ==2109 +== 5.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? == 2116 2116 2117 2117 2118 2118 LT-22222-L built-in relay is NO (Normal Open). User can use an external relay to achieve Normal Close purpose. Diagram as below: ... ... @@ -2121,18 +2121,18 @@ 2121 2121 [[image:image-20221006170630-1.png||height="610" width="945"]] 2122 2122 2123 2123 2124 -== 6.8 Can LT22222-L save RO state? ==2118 +== 5.8 Can LT22222-L save RO state? == 2125 2125 2126 2126 2127 2127 Firmware version needs to be no less than 1.6.0. 2128 2128 2129 2129 2130 -= 7. Trouble Shooting =2124 += 6. Trouble Shooting = 2131 2131 ))) 2132 2132 2133 2133 ((( 2134 2134 ((( 2135 -== 7.1 Downlink doesn't work, how to solve it? ==2129 +== 6.1 Downlink doesn't work, how to solve it? == 2136 2136 2137 2137 2138 2138 ))) ... ... @@ -2145,7 +2145,7 @@ 2145 2145 ((( 2146 2146 2147 2147 2148 -== 7.2 Have trouble to upload image. ==2142 +== 6.2 Have trouble to upload image. == 2149 2149 2150 2150 2151 2151 ))) ... ... @@ -2157,7 +2157,7 @@ 2157 2157 ((( 2158 2158 2159 2159 2160 -== 7.3 Why I can't join TTN in US915 /AU915 bands? ==2154 +== 6.3 Why I can't join TTN in US915 /AU915 bands? == 2161 2161 2162 2162 2163 2163 ))) ... ... @@ -2167,7 +2167,7 @@ 2167 2167 ))) 2168 2168 2169 2169 2170 -= 8. Order Info =2164 += 7. Order Info = 2171 2171 2172 2172 2173 2173 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** ... ... @@ -2185,7 +2185,7 @@ 2185 2185 * (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 2186 2186 2187 2187 2188 -= 9. Packing Info =2182 += 8. Packing Info = 2189 2189 2190 2190 2191 2191 **Package Includes**: ... ... @@ -2203,7 +2203,7 @@ 2203 2203 * Weight / pcs : 170g 2204 2204 2205 2205 2206 -= 10. Support =2200 += 9. Support = 2207 2207 2208 2208 2209 2209 * ((( ... ... @@ -2216,11 +2216,9 @@ 2216 2216 2217 2217 ))) 2218 2218 2219 -= 1 1. Reference =2213 += 10. Reference = 2220 2220 2221 2221 2222 2222 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2223 2223 * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 2224 2224 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 2225 - 2226 -