<
From version < 112.3 >
edited by Xiaoling
on 2023/03/31 09:39
To version < 110.2 >
edited by Xiaoling
on 2022/12/23 08:41
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -183,6 +183,8 @@
183 183  * Firmware upgradable via program port
184 184  * Counting
185 185  
186 +
187 +
186 186  == 1.4  Applications ==
187 187  
188 188  
... ... @@ -193,6 +193,8 @@
193 193  * Smart Cities
194 194  * Smart Factory
195 195  
198 +
199 +
196 196  == 1.5 Hardware Variants ==
197 197  
198 198  
... ... @@ -207,6 +207,8 @@
207 207  * 1 x Counting Port
208 208  )))
209 209  
214 +
215 +
210 210  = 2. Power ON Device =
211 211  
212 212  
... ... @@ -300,6 +300,8 @@
300 300  * (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
301 301  * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
302 302  
309 +
310 +
303 303  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
304 304  
305 305  
... ... @@ -356,6 +356,8 @@
356 356  ** DO1 is high in case there is load between DO1 and V+.
357 357  ** DO1 LED is off in both case
358 358  
367 +
368 +
359 359  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
360 360  
361 361  
... ... @@ -644,6 +644,7 @@
644 644  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
645 645  
646 646  
657 +
647 647  (% style="color:#037691" %)**Downlink Command to set Trigger Condition:**
648 648  
649 649  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
... ... @@ -704,6 +704,7 @@
704 704  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
705 705  
706 706  
718 +
707 707  (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below
708 708  
709 709  [[image:image-20220524090456-4.png]]
... ... @@ -717,6 +717,7 @@
717 717  00000101: Means both DI1 and DI2 trigger are enabled.
718 718  
719 719  
732 +
720 720  (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable.
721 721  
722 722  Downlink command to poll MOD6 status:
... ... @@ -752,6 +752,8 @@
752 752  
753 753  * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
754 754  
768 +
769 +
755 755  === 3.4.1 Common Commands ===
756 756  
757 757  
... ... @@ -1051,9 +1051,8 @@
1051 1051  
1052 1052   Latching time. Unit: ms
1053 1053  
1069 +Note:
1054 1054  
1055 -(% style="color:red" %)**Note: **
1056 -
1057 1057   Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes
1058 1058  
1059 1059   Before Firmwre v1.6.0 the latch time only suport 2 bytes.
... ... @@ -1082,7 +1082,7 @@
1082 1082  
1083 1083  
1084 1084  
1085 -==== 3.4.2. 14 Relay ~-~- Control Relay Output RO1/RO2 ====
1099 +==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1086 1086  
1087 1087  
1088 1088  * (% style="color:#037691" %)**AT Command:**
... ... @@ -1142,9 +1142,8 @@
1142 1142  
1143 1143  (% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms
1144 1144  
1159 +Note:
1145 1145  
1146 -(% style="color:red" %)**Note:**
1147 -
1148 1148   Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes
1149 1149  
1150 1150   Before Firmwre v1.6.0 the latch time only suport 2 bytes.
... ... @@ -1155,7 +1155,7 @@
1155 1155  
1156 1156  **Example payload:**
1157 1157  
1158 -**~1. 05 01 11 07 D0**
1171 +**~1. 05 01 11 07 D**
1159 1159  
1160 1160  Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state.
1161 1161  
... ... @@ -1523,9 +1523,9 @@
1523 1523  === 3.6.3 Digital Output Port: DO1/DO2 /DO3 ===
1524 1524  
1525 1525  
1526 -**(% style="color:blue" %)NPN output**: GND or Float. Max voltage can apply to output pin is 36v.
1539 +**NPN output**: GND or Float. Max voltage can apply to output pin is 36v.
1527 1527  
1528 -**(% style="color:red" %)Note: DO pins go to float when device is power off.**
1541 +Note: DO pins go to float when device is power off.
1529 1529  
1530 1530  [[image:1653357531600-905.png]]
1531 1531  
... ... @@ -1912,7 +1912,7 @@
1912 1912  **3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?
1913 1913  dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.**
1914 1914  
1915 -**4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5.**
1928 +**4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5**
1916 1916  
1917 1917  
1918 1918  )))
... ... @@ -1936,19 +1936,11 @@
1936 1936  )))
1937 1937  
1938 1938  
1939 -= 5. Case Study =
1952 += 5. FAQ =
1940 1940  
1941 -== 5.1 Counting how many objects pass in Flow Line ==
1954 +== 5.1 How to upgrade the image? ==
1942 1942  
1943 1943  
1944 -Reference Link: [[How to set up to count objects pass in flow line>>How to set up to count objects pass in flow line]]?
1945 -
1946 -
1947 -= 6. FAQ =
1948 -
1949 -== 6.1 How to upgrade the image? ==
1950 -
1951 -
1952 1952  The LT LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to LT to:
1953 1953  
1954 1954  * Support new features
... ... @@ -1976,10 +1976,8 @@
1976 1976  
1977 1977   [[image:image-20220524103407-12.png]]
1978 1978  
1979 -
1980 1980  [[image:image-20220524103429-13.png]]
1981 1981  
1982 -
1983 1983  [[image:image-20220524104033-15.png]]
1984 1984  
1985 1985  
... ... @@ -1991,7 +1991,7 @@
1991 1991  
1992 1992  (((
1993 1993  (((
1994 -== 6.2 How to change the LoRa Frequency Bands/Region? ==
1997 +== 5.2 How to change the LoRa Frequency Bands/Region? ==
1995 1995  
1996 1996  
1997 1997  )))
... ... @@ -2004,7 +2004,7 @@
2004 2004  (((
2005 2005  
2006 2006  
2007 -== 6.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? ==
2010 +== 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? ==
2008 2008  
2009 2009  
2010 2010  )))
... ... @@ -2067,7 +2067,7 @@
2067 2067  [[image:1653360498588-932.png||height="485" width="726"]]
2068 2068  
2069 2069  
2070 -== 6.4 Can I see counting event in Serial? ==
2073 +== 5.4 Can I see counting event in Serial? ==
2071 2071  
2072 2072  
2073 2073  (((
... ... @@ -2074,7 +2074,7 @@
2074 2074  User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first.
2075 2075  
2076 2076  
2077 -== 6.5 Can i use point to point communication for LT-22222-L? ==
2080 +== 5.5 Can i use point to point communication for LT-22222-L? ==
2078 2078  
2079 2079  
2080 2080  Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]  ,this is [[firmware>>https://github.com/dragino/LT-22222-L/releases]].
... ... @@ -2083,7 +2083,7 @@
2083 2083  )))
2084 2084  
2085 2085  (((
2086 -== 6.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
2089 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
2087 2087  
2088 2088  
2089 2089  If the device is not shut down, but directly powered off.
... ... @@ -2095,7 +2095,7 @@
2095 2095  After restart, the status before power failure will be read from flash.
2096 2096  
2097 2097  
2098 -== 6.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? ==
2101 +== 5.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? ==
2099 2099  
2100 2100  
2101 2101  LT-22222-L built-in relay is NO (Normal Open). User can use an external relay to achieve Normal Close purpose. Diagram as below:
... ... @@ -2104,18 +2104,18 @@
2104 2104  [[image:image-20221006170630-1.png||height="610" width="945"]]
2105 2105  
2106 2106  
2107 -== 6.8 Can LT22222-L save RO state? ==
2110 +== 5.8 Can LT22222-L save RO state? ==
2108 2108  
2109 2109  
2110 2110  Firmware version needs to be no less than 1.6.0.
2111 2111  
2112 2112  
2113 -= 7. Trouble Shooting =
2116 += 6. Trouble Shooting =
2114 2114  )))
2115 2115  
2116 2116  (((
2117 2117  (((
2118 -== 7.1 Downlink doesn't work, how to solve it? ==
2121 +== 6.1 Downlink doesn't work, how to solve it? ==
2119 2119  
2120 2120  
2121 2121  )))
... ... @@ -2128,7 +2128,7 @@
2128 2128  (((
2129 2129  
2130 2130  
2131 -== 7.2 Have trouble to upload image. ==
2134 +== 6.2 Have trouble to upload image. ==
2132 2132  
2133 2133  
2134 2134  )))
... ... @@ -2140,7 +2140,7 @@
2140 2140  (((
2141 2141  
2142 2142  
2143 -== 7.3 Why I can't join TTN in US915 /AU915 bands? ==
2146 +== 6.3 Why I can't join TTN in US915 /AU915 bands? ==
2144 2144  
2145 2145  
2146 2146  )))
... ... @@ -2150,7 +2150,7 @@
2150 2150  )))
2151 2151  
2152 2152  
2153 -= 8. Order Info =
2156 += 7. Order Info =
2154 2154  
2155 2155  
2156 2156  (% style="color:#4f81bd" %)**LT-22222-L-XXX:**
... ... @@ -2169,7 +2169,7 @@
2169 2169  
2170 2170  
2171 2171  
2172 -= 9. Packing Info =
2175 += 8. Packing Info =
2173 2173  
2174 2174  
2175 2175  **Package Includes**:
... ... @@ -2179,7 +2179,6 @@
2179 2179  * Bracket for controller x1
2180 2180  * Program cable x 1
2181 2181  
2182 -
2183 2183  **Dimension and weight**:
2184 2184  
2185 2185  * Device Size: 13.5 x 7 x 3 cm
... ... @@ -2189,7 +2189,7 @@
2189 2189  
2190 2190  
2191 2191  
2192 -= 10. Support =
2194 += 9. Support =
2193 2193  
2194 2194  
2195 2195  * (((
... ... @@ -2202,7 +2202,7 @@
2202 2202  
2203 2203  )))
2204 2204  
2205 -= 11. Reference​​​​​ =
2207 += 10. Reference​​​​​ =
2206 2206  
2207 2207  
2208 2208  * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
... ... @@ -2209,4 +2209,5 @@
2209 2209  * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]]
2210 2210  * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]]
2211 2211  
2214 +
2212 2212  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0