... ... @@ -15,6 +15,7 @@
15 15  
16 16  = 1.Introduction =
17 17  
18 +
18 18  == 1.1 What is LT Series I/O Controller ==
19 19  
20 20  (((
... ... @@ -53,6 +53,7 @@
53 53  
54 54  )))
55 55  
57 +
56 56  == 1.2  Specifications ==
57 57  
58 58  (((
... ... @@ -62,7 +62,7 @@
62 62  )))
63 63  
64 64  * (((
65 -STM32L072xxxx MCU
67 +STM32L072CZT6 MCU
66 66  )))
67 67  * (((
68 68  SX1276/78 Wireless Chip 
... ... @@ -169,6 +169,7 @@
169 169  Packet engine up to 256 bytes with CRC.
170 170  
171 171  
174 +
172 172  
173 173  )))
174 174  
... ... @@ -223,8 +223,10 @@
223 223  [[image:1653297104069-180.png]]
224 224  
225 225  
229 +
226 226  = 3. Operation Mode =
227 227  
232 +
228 228  == 3.1 How it works? ==
229 229  
230 230  
... ... @@ -237,6 +237,7 @@
237 237  )))
238 238  
239 239  
245 +
240 240  == 3.2 Example to join LoRaWAN network ==
241 241  
242 242  
... ... @@ -288,6 +288,7 @@
288 288  [[image:1653298044601-602.png||height="405" width="709"]]
289 289  
290 290  
297 +
291 291  == 3.3 Uplink Payload ==
292 292  
293 293  
... ... @@ -300,6 +300,7 @@
300 300  * (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
301 301  * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
302 302  
310 +
303 303  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
304 304  
305 305  
... ... @@ -356,6 +356,7 @@
356 356  ** DO1 is high in case there is load between DO1 and V+.
357 357  ** DO1 LED is off in both case
358 358  
367 +
359 359  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
360 360  
361 361  
... ... @@ -429,6 +429,7 @@
429 429  )))
430 430  
431 431  
441 +
432 432  === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI ===
433 433  
434 434  
... ... @@ -475,6 +475,7 @@
475 475  )))
476 476  
477 477  
488 +
478 478  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
479 479  
480 480  
... ... @@ -543,6 +543,7 @@
543 543  )))
544 544  
545 545  
557 +
546 546  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
547 547  
548 548  
... ... @@ -590,6 +590,7 @@
590 590  )))
591 591  
592 592  
605 +
593 593  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
594 594  
595 595  
... ... @@ -644,6 +644,7 @@
644 644  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
645 645  
646 646  
660 +
647 647  (% style="color:#037691" %)**Downlink Command to set Trigger Condition:**
648 648  
649 649  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
... ... @@ -704,6 +704,7 @@
704 704  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
705 705  
706 706  
721 +
707 707  (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below
708 708  
709 709  [[image:image-20220524090456-4.png]]
... ... @@ -717,6 +717,7 @@
717 717  00000101: Means both DI1 and DI2 trigger are enabled.
718 718  
719 719  
735 +
720 720  (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable.
721 721  
722 722  Downlink command to poll MOD6 status:
... ... @@ -726,6 +726,7 @@
726 726  When device got this command, it will send the MOD6 payload.
727 727  
728 728  
745 +
729 729  === 3.3.7 Payload Decoder ===
730 730  
731 731  (((
... ... @@ -735,6 +735,7 @@
735 735  )))
736 736  
737 737  
755 +
738 738  == 3.4 ​Configure LT via AT or Downlink ==
739 739  
740 740  
... ... @@ -760,8 +760,10 @@
760 760  )))
761 761  
762 762  
781 +
763 763  === 3.4.2 Sensor related commands ===
764 764  
784 +
765 765  ==== 3.4.2.1 Set Transmit Interval ====
766 766  
767 767  
... ... @@ -837,6 +837,7 @@
837 837  
838 838  
839 839  
860 +
840 840  ==== 3.4.2.5 Poll trigger settings ====
841 841  
842 842  
... ... @@ -919,7 +919,7 @@
919 919  
920 920  * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):**
921 921  
922 -(% style="color:blue" %)**0x09 02 aa bb cc   ** (%%)~/~/ same as AT+TRIG2=aa,0x(bb cc)
943 +(% style="color:blue" %)**0x09 02 aa bb cc   ** (%%)~/~/ same as AT+TRIG1=aa,0x(bb cc)
923 923  
924 924  
925 925  
... ... @@ -1051,14 +1051,6 @@
1051 1051  
1052 1052   Latching time. Unit: ms
1053 1053  
1054 -
1055 -(% style="color:red" %)**Note: **
1056 -
1057 - Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes
1058 -
1059 - Before Firmwre v1.6.0 the latch time only suport 2 bytes.
1060 -
1061 -
1062 1062  (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
1063 1063  
1064 1064  
... ... @@ -1082,7 +1082,7 @@
1082 1082  
1083 1083  
1084 1084  
1085 -==== 3.4.2. 14 Relay ~-~- Control Relay Output RO1/RO2 ====
1098 +==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1086 1086  
1087 1087  
1088 1088  * (% style="color:#037691" %)**AT Command:**
... ... @@ -1111,6 +1111,7 @@
1111 1111  
1112 1112  
1113 1113  
1127 +
1114 1114  ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
1115 1115  
1116 1116  
... ... @@ -1142,20 +1142,12 @@
1142 1142  
1143 1143  (% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms
1144 1144  
1145 -
1146 -(% style="color:red" %)**Note:**
1147 -
1148 - Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes
1149 -
1150 - Before Firmwre v1.6.0 the latch time only suport 2 bytes.
1151 -
1152 -
1153 1153  (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
1154 1154  
1155 1155  
1156 1156  **Example payload:**
1157 1157  
1158 -**~1. 05 01 11 07 D0**
1164 +**~1. 05 01 11 07 D**
1159 1159  
1160 1160  Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state.
1161 1161  
... ... @@ -1241,14 +1241,14 @@
1241 1241  
1242 1242  
1243 1243  
1244 -==== 3.4.2.20 Reset save RO DO state ====
1250 +==== 3.4.2.20 Reset save DR DO state ====
1245 1245  
1246 1246  
1247 1247  * (% style="color:#037691" %)**AT Command:**
1248 1248  
1249 -(% style="color:blue" %)**AT+RODORESET=1    **(%%)~/~/ RODO will close when the device joining the network. (default)
1255 +(% style="color:blue" %)**AT+RODORET=1    **(%%)~/~/ RODO will close when the device joining the network. (default)
1250 1250  
1251 -(% style="color:blue" %)**AT+RODORESET=0    **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network.
1257 +(% style="color:blue" %)**AT+RODORET=0    **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network.
1252 1252  
1253 1253  
1254 1254  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):**
... ... @@ -1290,6 +1290,7 @@
1290 1290  
1291 1291  
1292 1292  
1299 +
1293 1293  ==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ====
1294 1294  
1295 1295  
... ... @@ -1306,6 +1306,7 @@
1306 1306  
1307 1307  
1308 1308  
1316 +
1309 1309  ==== 3.4.2.25 Copy downlink to uplink ====
1310 1310  
1311 1311  
... ... @@ -1344,6 +1344,7 @@
1344 1344  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]]
1345 1345  
1346 1346  
1355 +
1347 1347  == 3.5 Integrate with Mydevice ==
1348 1348  
1349 1349  
... ... @@ -1393,8 +1393,10 @@
1393 1393  [[image:image-20220524094909-5.png||height="341" width="734"]]
1394 1394  
1395 1395  
1405 +
1396 1396  == 3.6 Interface Detail ==
1397 1397  
1408 +
1398 1398  === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) ===
1399 1399  
1400 1400  
... ... @@ -1403,6 +1403,7 @@
1403 1403  [[image:1653356991268-289.png]]
1404 1404  
1405 1405  
1417 +
1406 1406  === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) ===
1407 1407  
1408 1408  
... ... @@ -1459,6 +1459,8 @@
1459 1459  
1460 1460  (((
1461 1461  
1474 +
1475 +
1462 1462  )))
1463 1463  
1464 1464  (((
... ... @@ -1490,6 +1490,8 @@
1490 1490  
1491 1491  (((
1492 1492  
1507 +
1508 +
1493 1493  )))
1494 1494  
1495 1495  (((
... ... @@ -1520,16 +1520,16 @@
1520 1520  )))
1521 1521  
1522 1522  
1539 +
1523 1523  === 3.6.3 Digital Output Port: DO1/DO2 /DO3 ===
1524 1524  
1525 1525  
1526 -**NPN output**: GND or Float. Max voltage can apply to output pin is 36v.
1543 +NPN output: GND or Float. Max voltage can apply to output pin is 36v.
1527 1527  
1528 -Note: DO pins go to float when device is power off.
1529 -
1530 1530  [[image:1653357531600-905.png]]
1531 1531  
1532 1532  
1548 +
1533 1533  === 3.6.4 Analog Input Interface ===
1534 1534  
1535 1535  
... ... @@ -1561,13 +1561,12 @@
1561 1561  [[image:1653357648330-671.png||height="155" width="733"]]
1562 1562  
1563 1563  
1580 +
1564 1564  === 3.6.5 Relay Output ===
1565 1565  
1566 1566  
1567 1567  (((
1568 -The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device's Power Line to in serial of RO1_1 and RO_2. Such as below:
1569 -
1570 -**Note**: RO pins go to Open(NO) when device is power off.
1585 +The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device’s Power Line to in serial of RO1_1 and RO_2. Such as below:
1571 1571  )))
1572 1572  
1573 1573  [[image:image-20220524100215-9.png]]
... ... @@ -1576,6 +1576,7 @@
1576 1576  [[image:image-20220524100215-10.png||height="382" width="723"]]
1577 1577  
1578 1578  
1594 +
1579 1579  == 3.7 LEDs Indicators ==
1580 1580  
1581 1581  
... ... @@ -1582,8 +1582,10 @@
1582 1582  [[image:image-20220524100748-11.png]]
1583 1583  
1584 1584  
1601 +
1585 1585  = 4. Use AT Command =
1586 1586  
1604 +
1587 1587  == 4.1 Access AT Command ==
1588 1588  
1589 1589  
... ... @@ -1794,8 +1794,10 @@
1794 1794  )))
1795 1795  
1796 1796  
1815 +
1797 1797  == 4.2 Common AT Command Sequence ==
1798 1798  
1818 +
1799 1799  === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1800 1800  
1801 1801  (((
... ... @@ -1840,6 +1840,7 @@
1840 1840  )))
1841 1841  
1842 1842  
1863 +
1843 1843  === 4.2.2 Single-channel ABP mode (Use with LG01/LG02) ===
1844 1844  
1845 1845  (((
... ... @@ -1925,6 +1925,7 @@
1925 1925  
1926 1926  )))
1927 1927  
1949 +
1928 1928  === 4.2.3 Change to Class A ===
1929 1929  
1930 1930  
... ... @@ -1936,19 +1936,13 @@
1936 1936  )))
1937 1937  
1938 1938  
1939 -= 5. Case Study =
1940 1940  
1941 -== 5.1 Counting how many objects pass in Flow Line ==
1962 += 5. FAQ =
1942 1942  
1943 1943  
1944 -Reference Link: [[How to set up to count objects pass in flow line>>How to set up to count objects pass in flow line]]?
1965 +== 5.1 How to upgrade the image? ==
1945 1945  
1946 1946  
1947 -= 6. FAQ =
1948 -
1949 -== 6.1 How to upgrade the image? ==
1950 -
1951 -
1952 1952  The LT LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to LT to:
1953 1953  
1954 1954  * Support new features
... ... @@ -1989,8 +1989,10 @@
1989 1989  
1990 1990  (((
1991 1991  (((
1992 -== 6.2 How to change the LoRa Frequency Bands/Region? ==
2008 +
1993 1993  
2010 +== 5.2 How to change the LoRa Frequency Bands/Region? ==
2011 +
1994 1994  
1995 1995  )))
1996 1996  )))
... ... @@ -2002,8 +2002,9 @@
2002 2002  (((
2003 2003  
2004 2004  
2005 -== 6.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? ==
2006 2006  
2024 +== 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? ==
2025 +
2007 2007  
2008 2008  )))
2009 2009  
... ... @@ -2065,23 +2065,26 @@
2065 2065  [[image:1653360498588-932.png||height="485" width="726"]]
2066 2066  
2067 2067  
2068 -== 6.4 Can I see counting event in Serial? ==
2069 2069  
2088 +== 5.4 Can I see counting event in Serial? ==
2070 2070  
2090 +
2071 2071  (((
2072 2072  User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first.
2073 2073  
2074 2074  
2075 -== 6.5 Can i use point to point communication for LT-22222-L? ==
2076 2076  
2096 +== 5.5 Can i use point to point communication for LT-22222-L? ==
2077 2077  
2078 -Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]  ,this is [[firmware>>https://github.com/dragino/LT-22222-L/releases]].
2079 2079  
2099 +Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]  ,this is [[firmware>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AADKXQ2v5ZT-S3sxdmbvE7UAa/LT-22222-L/image?dl=0&subfolder_nav_tracking=1]].
2100 +
2101 +
2080 2080  
2081 2081  )))
2082 2082  
2083 2083  (((
2084 -== 6.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
2106 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
2085 2085  
2086 2086  
2087 2087  If the device is not shut down, but directly powered off.
... ... @@ -2093,9 +2093,10 @@
2093 2093  After restart, the status before power failure will be read from flash.
2094 2094  
2095 2095  
2096 -== 6.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? ==
2097 2097  
2119 +== 5.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? ==
2098 2098  
2121 +
2099 2099  LT-22222-L built-in relay is NO (Normal Open). User can use an external relay to achieve Normal Close purpose. Diagram as below:
2100 2100  
2101 2101  
... ... @@ -2102,18 +2102,19 @@
2102 2102  [[image:image-20221006170630-1.png||height="610" width="945"]]
2103 2103  
2104 2104  
2105 -== 6.8 Can LT22222-L save RO state? ==
2128 +== 5.8 Can LT22222 save RO state? ==
2106 2106  
2107 -
2108 2108  Firmware version needs to be no less than 1.6.0.
2109 2109  
2110 2110  
2111 -= 7. Trouble Shooting =
2133 += 6. Trouble Shooting =
2134 +
2135 +
2112 2112  )))
2113 2113  
2114 2114  (((
2115 2115  (((
2116 -== 7.1 Downlink doesn't work, how to solve it? ==
2140 +== 6.1 Downlink doesn't work, how to solve it? ==
2117 2117  
2118 2118  
2119 2119  )))
... ... @@ -2126,8 +2126,9 @@
2126 2126  (((
2127 2127  
2128 2128  
2129 -== 7.2 Have trouble to upload image. ==
2130 2130  
2154 +== 6.2 Have trouble to upload image. ==
2155 +
2131 2131  
2132 2132  )))
2133 2133  
... ... @@ -2138,8 +2138,9 @@
2138 2138  (((
2139 2139  
2140 2140  
2141 -== 7.3 Why I can't join TTN in US915 /AU915 bands? ==
2142 2142  
2167 +== 6.3 Why I can't join TTN in US915 /AU915 bands? ==
2168 +
2143 2143  
2144 2144  )))
2145 2145  
... ... @@ -2148,9 +2148,10 @@
2148 2148  )))
2149 2149  
2150 2150  
2151 -= 8. Order Info =
2152 2152  
2178 += 7. Order Info =
2153 2153  
2180 +
2154 2154  (% style="color:#4f81bd" %)**LT-22222-L-XXX:**
2155 2155  
2156 2156  (% style="color:#4f81bd" %)**XXX:**
... ... @@ -2165,7 +2165,7 @@
2165 2165  * (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
2166 2166  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2167 2167  
2168 -= 9. Packing Info =
2195 += 8. Packing Info =
2169 2169  
2170 2170  
2171 2171  **Package Includes**:
... ... @@ -2182,9 +2182,11 @@
2182 2182  * Package Size / pcs : 14.5 x 8 x 5 cm
2183 2183  * Weight / pcs : 170g
2184 2184  
2185 -= 10. Support =
2212 +
2186 2186  
2214 += 9. Support =
2187 2187  
2216 +
2188 2188  * (((
2189 2189  Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
2190 2190  )))
... ... @@ -2192,14 +2192,13 @@
2192 2192  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
2193 2193  
2194 2194  
2224 +
2195 2195  
2196 2196  )))
2197 2197  
2198 -= 11. Reference​​​​​ =
2228 += 10. Reference​​​​​ =
2199 2199  
2200 2200  
2201 2201  * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
2202 2202  * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]]
2203 2203  * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]]
2204 -
2205 -
image-20221112174847-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -102.6 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved