From version < 112.1 >
edited by Edwin Chen
on 2023/03/30 16:18
To version < 111.1 >
edited by Bei Jinggeng
on 2023/01/10 17:26
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Bei
Content
... ... @@ -649,6 +649,7 @@
649 649  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
650 650  
651 651  
652 +
652 652  (% style="color:#037691" %)**Downlink Command to set Trigger Condition:**
653 653  
654 654  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
... ... @@ -709,6 +709,7 @@
709 709  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
710 710  
711 711  
713 +
712 712  (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below
713 713  
714 714  [[image:image-20220524090456-4.png]]
... ... @@ -722,6 +722,7 @@
722 722  00000101: Means both DI1 and DI2 trigger are enabled.
723 723  
724 724  
727 +
725 725  (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable.
726 726  
727 727  Downlink command to poll MOD6 status:
... ... @@ -1057,9 +1057,8 @@
1057 1057  
1058 1058   Latching time. Unit: ms
1059 1059  
1063 +Note:
1060 1060  
1061 -(% style="color:red" %)**Note: **
1062 -
1063 1063   Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes
1064 1064  
1065 1065   Before Firmwre v1.6.0 the latch time only suport 2 bytes.
... ... @@ -1088,7 +1088,7 @@
1088 1088  
1089 1089  
1090 1090  
1091 -==== 3.4.2. 14 Relay ~-~- Control Relay Output RO1/RO2 ====
1093 +==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1092 1092  
1093 1093  
1094 1094  * (% style="color:#037691" %)**AT Command:**
... ... @@ -1148,9 +1148,8 @@
1148 1148  
1149 1149  (% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms
1150 1150  
1153 +Note:
1151 1151  
1152 -(% style="color:red" %)**Note:**
1153 -
1154 1154   Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes
1155 1155  
1156 1156   Before Firmwre v1.6.0 the latch time only suport 2 bytes.
... ... @@ -1942,14 +1942,6 @@
1942 1942  )))
1943 1943  
1944 1944  
1945 -= 5. Case Study =
1946 -
1947 -== 5.1 Counting how many objects pass in Flow Line ==
1948 -
1949 -
1950 -Reference Link: [[How to set up to count objects pass in flow line>>How to set up to count objects pass in flow line]]?
1951 -
1952 -
1953 1953  = 5. FAQ =
1954 1954  
1955 1955  == 5.1 How to upgrade the image? ==
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0