Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Edwin - Content
-
... ... @@ -15,6 +15,7 @@ 15 15 16 16 = 1.Introduction = 17 17 18 + 18 18 == 1.1 What is LT Series I/O Controller == 19 19 20 20 ((( ... ... @@ -53,6 +53,7 @@ 53 53 54 54 ))) 55 55 57 + 56 56 == 1.2 Specifications == 57 57 58 58 ((( ... ... @@ -169,6 +169,7 @@ 169 169 Packet engine up to 256 bytes with CRC. 170 170 171 171 174 + 172 172 173 173 ))) 174 174 ... ... @@ -183,8 +183,6 @@ 183 183 * Firmware upgradable via program port 184 184 * Counting 185 185 186 - 187 - 188 188 == 1.4 Applications == 189 189 190 190 ... ... @@ -195,8 +195,6 @@ 195 195 * Smart Cities 196 196 * Smart Factory 197 197 198 - 199 - 200 200 == 1.5 Hardware Variants == 201 201 202 202 ... ... @@ -211,8 +211,6 @@ 211 211 * 1 x Counting Port 212 212 ))) 213 213 214 - 215 - 216 216 = 2. Power ON Device = 217 217 218 218 ... ... @@ -229,8 +229,10 @@ 229 229 [[image:1653297104069-180.png]] 230 230 231 231 229 + 232 232 = 3. Operation Mode = 233 233 232 + 234 234 == 3.1 How it works? == 235 235 236 236 ... ... @@ -243,6 +243,7 @@ 243 243 ))) 244 244 245 245 245 + 246 246 == 3.2 Example to join LoRaWAN network == 247 247 248 248 ... ... @@ -294,6 +294,7 @@ 294 294 [[image:1653298044601-602.png||height="405" width="709"]] 295 295 296 296 297 + 297 297 == 3.3 Uplink Payload == 298 298 299 299 ... ... @@ -306,8 +306,6 @@ 306 306 * (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 307 307 * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 308 308 309 - 310 - 311 311 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 312 312 313 313 ... ... @@ -364,8 +364,6 @@ 364 364 ** DO1 is high in case there is load between DO1 and V+. 365 365 ** DO1 LED is off in both case 366 366 367 - 368 - 369 369 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 370 370 371 371 ... ... @@ -439,6 +439,7 @@ 439 439 ))) 440 440 441 441 439 + 442 442 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 443 443 444 444 ... ... @@ -485,6 +485,7 @@ 485 485 ))) 486 486 487 487 486 + 488 488 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 489 489 490 490 ... ... @@ -553,6 +553,7 @@ 553 553 ))) 554 554 555 555 555 + 556 556 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 557 557 558 558 ... ... @@ -600,6 +600,7 @@ 600 600 ))) 601 601 602 602 603 + 603 603 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 604 604 605 605 ... ... @@ -654,6 +654,7 @@ 654 654 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 655 655 656 656 658 + 657 657 (% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 658 658 659 659 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** ... ... @@ -714,6 +714,7 @@ 714 714 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. 715 715 716 716 719 + 717 717 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 718 718 719 719 [[image:image-20220524090456-4.png]] ... ... @@ -727,6 +727,7 @@ 727 727 00000101: Means both DI1 and DI2 trigger are enabled. 728 728 729 729 733 + 730 730 (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable. 731 731 732 732 Downlink command to poll MOD6 status: ... ... @@ -736,6 +736,7 @@ 736 736 When device got this command, it will send the MOD6 payload. 737 737 738 738 743 + 739 739 === 3.3.7 Payload Decoder === 740 740 741 741 ((( ... ... @@ -745,6 +745,7 @@ 745 745 ))) 746 746 747 747 753 + 748 748 == 3.4 Configure LT via AT or Downlink == 749 749 750 750 ... ... @@ -762,8 +762,6 @@ 762 762 763 763 * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 764 764 765 - 766 - 767 767 === 3.4.1 Common Commands === 768 768 769 769 ... ... @@ -772,8 +772,10 @@ 772 772 ))) 773 773 774 774 779 + 775 775 === 3.4.2 Sensor related commands === 776 776 782 + 777 777 ==== 3.4.2.1 Set Transmit Interval ==== 778 778 779 779 ... ... @@ -849,6 +849,7 @@ 849 849 850 850 851 851 858 + 852 852 ==== 3.4.2.5 Poll trigger settings ==== 853 853 854 854 ... ... @@ -931,7 +931,7 @@ 931 931 932 932 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 933 933 934 -(% style="color:blue" %)**0x09 02 aa bb cc ** (%%)~/~/ same as AT+TRIG 2=aa,0x(bb cc)941 +(% style="color:blue" %)**0x09 02 aa bb cc ** (%%)~/~/ same as AT+TRIG1=aa,0x(bb cc) 935 935 936 936 937 937 ... ... @@ -1063,14 +1063,6 @@ 1063 1063 1064 1064 Latching time. Unit: ms 1065 1065 1066 - 1067 -(% style="color:red" %)**Note: ** 1068 - 1069 - Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1070 - 1071 - Before Firmwre v1.6.0 the latch time only suport 2 bytes. 1072 - 1073 - 1074 1074 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1075 1075 1076 1076 ... ... @@ -1094,7 +1094,7 @@ 1094 1094 1095 1095 1096 1096 1097 -==== 3.4.2. 1096 +==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1098 1098 1099 1099 1100 1100 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1123,6 +1123,7 @@ 1123 1123 1124 1124 1125 1125 1125 + 1126 1126 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1127 1127 1128 1128 ... ... @@ -1154,20 +1154,12 @@ 1154 1154 1155 1155 (% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms 1156 1156 1157 - 1158 -(% style="color:red" %)**Note:** 1159 - 1160 - Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1161 - 1162 - Before Firmwre v1.6.0 the latch time only suport 2 bytes. 1163 - 1164 - 1165 1165 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1166 1166 1167 1167 1168 1168 **Example payload:** 1169 1169 1170 -**~1. 05 01 11 07 D 0**1162 +**~1. 05 01 11 07 D** 1171 1171 1172 1172 Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state. 1173 1173 ... ... @@ -1302,6 +1302,7 @@ 1302 1302 1303 1303 1304 1304 1297 + 1305 1305 ==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ==== 1306 1306 1307 1307 ... ... @@ -1318,6 +1318,7 @@ 1318 1318 1319 1319 1320 1320 1314 + 1321 1321 ==== 3.4.2.25 Copy downlink to uplink ==== 1322 1322 1323 1323 ... ... @@ -1356,6 +1356,7 @@ 1356 1356 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]] 1357 1357 1358 1358 1353 + 1359 1359 == 3.5 Integrate with Mydevice == 1360 1360 1361 1361 ... ... @@ -1405,8 +1405,10 @@ 1405 1405 [[image:image-20220524094909-5.png||height="341" width="734"]] 1406 1406 1407 1407 1403 + 1408 1408 == 3.6 Interface Detail == 1409 1409 1406 + 1410 1410 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === 1411 1411 1412 1412 ... ... @@ -1415,6 +1415,7 @@ 1415 1415 [[image:1653356991268-289.png]] 1416 1416 1417 1417 1415 + 1418 1418 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1419 1419 1420 1420 ... ... @@ -1471,6 +1471,8 @@ 1471 1471 1472 1472 ((( 1473 1473 1472 + 1473 + 1474 1474 ))) 1475 1475 1476 1476 ((( ... ... @@ -1502,6 +1502,8 @@ 1502 1502 1503 1503 ((( 1504 1504 1505 + 1506 + 1505 1505 ))) 1506 1506 1507 1507 ((( ... ... @@ -1532,6 +1532,7 @@ 1532 1532 ))) 1533 1533 1534 1534 1537 + 1535 1535 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1536 1536 1537 1537 ... ... @@ -1542,6 +1542,7 @@ 1542 1542 [[image:1653357531600-905.png]] 1543 1543 1544 1544 1548 + 1545 1545 === 3.6.4 Analog Input Interface === 1546 1546 1547 1547 ... ... @@ -1573,6 +1573,7 @@ 1573 1573 [[image:1653357648330-671.png||height="155" width="733"]] 1574 1574 1575 1575 1580 + 1576 1576 === 3.6.5 Relay Output === 1577 1577 1578 1578 ... ... @@ -1588,6 +1588,7 @@ 1588 1588 [[image:image-20220524100215-10.png||height="382" width="723"]] 1589 1589 1590 1590 1596 + 1591 1591 == 3.7 LEDs Indicators == 1592 1592 1593 1593 ... ... @@ -1594,8 +1594,10 @@ 1594 1594 [[image:image-20220524100748-11.png]] 1595 1595 1596 1596 1603 + 1597 1597 = 4. Use AT Command = 1598 1598 1606 + 1599 1599 == 4.1 Access AT Command == 1600 1600 1601 1601 ... ... @@ -1806,8 +1806,10 @@ 1806 1806 ))) 1807 1807 1808 1808 1817 + 1809 1809 == 4.2 Common AT Command Sequence == 1810 1810 1820 + 1811 1811 === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1812 1812 1813 1813 ((( ... ... @@ -1852,6 +1852,7 @@ 1852 1852 ))) 1853 1853 1854 1854 1865 + 1855 1855 === 4.2.2 Single-channel ABP mode (Use with LG01/LG02) === 1856 1856 1857 1857 ((( ... ... @@ -1937,6 +1937,7 @@ 1937 1937 1938 1938 ))) 1939 1939 1951 + 1940 1940 === 4.2.3 Change to Class A === 1941 1941 1942 1942 ... ... @@ -1948,8 +1948,10 @@ 1948 1948 ))) 1949 1949 1950 1950 1963 + 1951 1951 = 5. FAQ = 1952 1952 1966 + 1953 1953 == 5.1 How to upgrade the image? == 1954 1954 1955 1955 ... ... @@ -1993,6 +1993,8 @@ 1993 1993 1994 1994 ((( 1995 1995 ((( 2010 + 2011 + 1996 1996 == 5.2 How to change the LoRa Frequency Bands/Region? == 1997 1997 1998 1998 ... ... @@ -2006,6 +2006,7 @@ 2006 2006 ((( 2007 2007 2008 2008 2025 + 2009 2009 == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 2010 2010 2011 2011 ... ... @@ -2069,6 +2069,7 @@ 2069 2069 [[image:1653360498588-932.png||height="485" width="726"]] 2070 2070 2071 2071 2089 + 2072 2072 == 5.4 Can I see counting event in Serial? == 2073 2073 2074 2074 ... ... @@ -2076,11 +2076,13 @@ 2076 2076 User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 2077 2077 2078 2078 2097 + 2079 2079 == 5.5 Can i use point to point communication for LT-22222-L? == 2080 2080 2081 2081 2082 2082 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https://github.com/dragino/LT-22222-L/releases]]. 2083 2083 2103 + 2084 2084 2085 2085 ))) 2086 2086 ... ... @@ -2097,6 +2097,7 @@ 2097 2097 After restart, the status before power failure will be read from flash. 2098 2098 2099 2099 2120 + 2100 2100 == 5.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? == 2101 2101 2102 2102 ... ... @@ -2112,7 +2112,10 @@ 2112 2112 Firmware version needs to be no less than 1.6.0. 2113 2113 2114 2114 2136 + 2115 2115 = 6. Trouble Shooting = 2138 + 2139 + 2116 2116 ))) 2117 2117 2118 2118 ((( ... ... @@ -2130,6 +2130,7 @@ 2130 2130 ((( 2131 2131 2132 2132 2157 + 2133 2133 == 6.2 Have trouble to upload image. == 2134 2134 2135 2135 ... ... @@ -2142,6 +2142,7 @@ 2142 2142 ((( 2143 2143 2144 2144 2170 + 2145 2145 == 6.3 Why I can't join TTN in US915 /AU915 bands? == 2146 2146 2147 2147 ... ... @@ -2152,6 +2152,7 @@ 2152 2152 ))) 2153 2153 2154 2154 2181 + 2155 2155 = 7. Order Info = 2156 2156 2157 2157 ... ... @@ -2169,8 +2169,6 @@ 2169 2169 * (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 2170 2170 * (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 2171 2171 2172 - 2173 - 2174 2174 = 8. Packing Info = 2175 2175 2176 2176 ... ... @@ -2188,8 +2188,6 @@ 2188 2188 * Package Size / pcs : 14.5 x 8 x 5 cm 2189 2189 * Weight / pcs : 170g 2190 2190 2191 - 2192 - 2193 2193 = 9. Support = 2194 2194 2195 2195 ... ... @@ -2209,5 +2209,3 @@ 2209 2209 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2210 2210 * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 2211 2211 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 2212 - 2213 -