Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -15,6 +15,7 @@ 15 15 16 16 = 1.Introduction = 17 17 18 + 18 18 == 1.1 What is LT Series I/O Controller == 19 19 20 20 ((( ... ... @@ -53,6 +53,7 @@ 53 53 54 54 ))) 55 55 57 + 56 56 == 1.2 Specifications == 57 57 58 58 ((( ... ... @@ -62,7 +62,7 @@ 62 62 ))) 63 63 64 64 * ((( 65 -STM32L072 xxxxMCU67 +STM32L072CZT6 MCU 66 66 ))) 67 67 * ((( 68 68 SX1276/78 Wireless Chip ... ... @@ -169,6 +169,7 @@ 169 169 Packet engine up to 256 bytes with CRC. 170 170 171 171 174 + 172 172 173 173 ))) 174 174 ... ... @@ -183,8 +183,6 @@ 183 183 * Firmware upgradable via program port 184 184 * Counting 185 185 186 - 187 - 188 188 == 1.4 Applications == 189 189 190 190 ... ... @@ -195,8 +195,6 @@ 195 195 * Smart Cities 196 196 * Smart Factory 197 197 198 - 199 - 200 200 == 1.5 Hardware Variants == 201 201 202 202 ... ... @@ -211,8 +211,6 @@ 211 211 * 1 x Counting Port 212 212 ))) 213 213 214 - 215 - 216 216 = 2. Power ON Device = 217 217 218 218 ... ... @@ -229,8 +229,10 @@ 229 229 [[image:1653297104069-180.png]] 230 230 231 231 229 + 232 232 = 3. Operation Mode = 233 233 232 + 234 234 == 3.1 How it works? == 235 235 236 236 ... ... @@ -243,6 +243,7 @@ 243 243 ))) 244 244 245 245 245 + 246 246 == 3.2 Example to join LoRaWAN network == 247 247 248 248 ... ... @@ -294,6 +294,7 @@ 294 294 [[image:1653298044601-602.png||height="405" width="709"]] 295 295 296 296 297 + 297 297 == 3.3 Uplink Payload == 298 298 299 299 ... ... @@ -307,7 +307,6 @@ 307 307 * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 308 308 309 309 310 - 311 311 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 312 312 313 313 ... ... @@ -365,7 +365,6 @@ 365 365 ** DO1 LED is off in both case 366 366 367 367 368 - 369 369 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 370 370 371 371 ... ... @@ -439,6 +439,7 @@ 439 439 ))) 440 440 441 441 441 + 442 442 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 443 443 444 444 ... ... @@ -485,6 +485,7 @@ 485 485 ))) 486 486 487 487 488 + 488 488 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 489 489 490 490 ... ... @@ -553,6 +553,7 @@ 553 553 ))) 554 554 555 555 557 + 556 556 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 557 557 558 558 ... ... @@ -600,6 +600,7 @@ 600 600 ))) 601 601 602 602 605 + 603 603 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 604 604 605 605 ... ... @@ -654,6 +654,7 @@ 654 654 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 655 655 656 656 660 + 657 657 (% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 658 658 659 659 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** ... ... @@ -714,6 +714,7 @@ 714 714 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. 715 715 716 716 721 + 717 717 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 718 718 719 719 [[image:image-20220524090456-4.png]] ... ... @@ -727,6 +727,7 @@ 727 727 00000101: Means both DI1 and DI2 trigger are enabled. 728 728 729 729 735 + 730 730 (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable. 731 731 732 732 Downlink command to poll MOD6 status: ... ... @@ -736,6 +736,7 @@ 736 736 When device got this command, it will send the MOD6 payload. 737 737 738 738 745 + 739 739 === 3.3.7 Payload Decoder === 740 740 741 741 ((( ... ... @@ -745,6 +745,7 @@ 745 745 ))) 746 746 747 747 755 + 748 748 == 3.4 Configure LT via AT or Downlink == 749 749 750 750 ... ... @@ -762,8 +762,6 @@ 762 762 763 763 * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 764 764 765 - 766 - 767 767 === 3.4.1 Common Commands === 768 768 769 769 ... ... @@ -772,8 +772,10 @@ 772 772 ))) 773 773 774 774 781 + 775 775 === 3.4.2 Sensor related commands === 776 776 784 + 777 777 ==== 3.4.2.1 Set Transmit Interval ==== 778 778 779 779 ... ... @@ -849,6 +849,7 @@ 849 849 850 850 851 851 860 + 852 852 ==== 3.4.2.5 Poll trigger settings ==== 853 853 854 854 ... ... @@ -931,7 +931,7 @@ 931 931 932 932 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 933 933 934 -(% style="color:blue" %)**0x09 02 aa bb cc ** (%%)~/~/ same as AT+TRIG 2=aa,0x(bb cc)943 +(% style="color:blue" %)**0x09 02 aa bb cc ** (%%)~/~/ same as AT+TRIG1=aa,0x(bb cc) 935 935 936 936 937 937 ... ... @@ -1063,14 +1063,6 @@ 1063 1063 1064 1064 Latching time. Unit: ms 1065 1065 1066 - 1067 -(% style="color:red" %)**Note: ** 1068 - 1069 - Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1070 - 1071 - Before Firmwre v1.6.0 the latch time only suport 2 bytes. 1072 - 1073 - 1074 1074 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1075 1075 1076 1076 ... ... @@ -1094,7 +1094,7 @@ 1094 1094 1095 1095 1096 1096 1097 -==== 3.4.2. 1098 +==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1098 1098 1099 1099 1100 1100 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1123,6 +1123,7 @@ 1123 1123 1124 1124 1125 1125 1127 + 1126 1126 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1127 1127 1128 1128 ... ... @@ -1154,20 +1154,12 @@ 1154 1154 1155 1155 (% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms 1156 1156 1157 - 1158 -(% style="color:red" %)**Note:** 1159 - 1160 - Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1161 - 1162 - Before Firmwre v1.6.0 the latch time only suport 2 bytes. 1163 - 1164 - 1165 1165 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1166 1166 1167 1167 1168 1168 **Example payload:** 1169 1169 1170 -**~1. 05 01 11 07 D 0**1164 +**~1. 05 01 11 07 D** 1171 1171 1172 1172 Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state. 1173 1173 ... ... @@ -1253,14 +1253,14 @@ 1253 1253 1254 1254 1255 1255 1256 -==== 3.4.2.20 Reset save R ODO state ====1250 +==== 3.4.2.20 Reset save DR DO state ==== 1257 1257 1258 1258 1259 1259 * (% style="color:#037691" %)**AT Command:** 1260 1260 1261 -(% style="color:blue" %)**AT+RODORE SET=1 **(%%)~/~/ RODO will close when the device joining the network. (default)1255 +(% style="color:blue" %)**AT+RODORET=1 **(%%)~/~/ RODO will close when the device joining the network. (default) 1262 1262 1263 -(% style="color:blue" %)**AT+RODORE SET=0 **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network.1257 +(% style="color:blue" %)**AT+RODORET=0 **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network. 1264 1264 1265 1265 1266 1266 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):** ... ... @@ -1302,6 +1302,7 @@ 1302 1302 1303 1303 1304 1304 1299 + 1305 1305 ==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ==== 1306 1306 1307 1307 ... ... @@ -1318,6 +1318,7 @@ 1318 1318 1319 1319 1320 1320 1316 + 1321 1321 ==== 3.4.2.25 Copy downlink to uplink ==== 1322 1322 1323 1323 ... ... @@ -1356,6 +1356,7 @@ 1356 1356 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]] 1357 1357 1358 1358 1355 + 1359 1359 == 3.5 Integrate with Mydevice == 1360 1360 1361 1361 ... ... @@ -1405,8 +1405,10 @@ 1405 1405 [[image:image-20220524094909-5.png||height="341" width="734"]] 1406 1406 1407 1407 1405 + 1408 1408 == 3.6 Interface Detail == 1409 1409 1408 + 1410 1410 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === 1411 1411 1412 1412 ... ... @@ -1415,6 +1415,7 @@ 1415 1415 [[image:1653356991268-289.png]] 1416 1416 1417 1417 1417 + 1418 1418 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1419 1419 1420 1420 ... ... @@ -1471,6 +1471,8 @@ 1471 1471 1472 1472 ((( 1473 1473 1474 + 1475 + 1474 1474 ))) 1475 1475 1476 1476 ((( ... ... @@ -1502,6 +1502,8 @@ 1502 1502 1503 1503 ((( 1504 1504 1507 + 1508 + 1505 1505 ))) 1506 1506 1507 1507 ((( ... ... @@ -1532,16 +1532,16 @@ 1532 1532 ))) 1533 1533 1534 1534 1539 + 1535 1535 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1536 1536 1537 1537 1538 - **NPN output**: GND or Float. Max voltage can apply to output pin is 36v.1543 +NPN output: GND or Float. Max voltage can apply to output pin is 36v. 1539 1539 1540 -Note: DO pins go to float when device is power off. 1541 - 1542 1542 [[image:1653357531600-905.png]] 1543 1543 1544 1544 1548 + 1545 1545 === 3.6.4 Analog Input Interface === 1546 1546 1547 1547 ... ... @@ -1573,13 +1573,12 @@ 1573 1573 [[image:1653357648330-671.png||height="155" width="733"]] 1574 1574 1575 1575 1580 + 1576 1576 === 3.6.5 Relay Output === 1577 1577 1578 1578 1579 1579 ((( 1580 -The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device's Power Line to in serial of RO1_1 and RO_2. Such as below: 1581 - 1582 -**Note**: RO pins go to Open(NO) when device is power off. 1585 +The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device’s Power Line to in serial of RO1_1 and RO_2. Such as below: 1583 1583 ))) 1584 1584 1585 1585 [[image:image-20220524100215-9.png]] ... ... @@ -1588,6 +1588,7 @@ 1588 1588 [[image:image-20220524100215-10.png||height="382" width="723"]] 1589 1589 1590 1590 1594 + 1591 1591 == 3.7 LEDs Indicators == 1592 1592 1593 1593 ... ... @@ -1594,8 +1594,10 @@ 1594 1594 [[image:image-20220524100748-11.png]] 1595 1595 1596 1596 1601 + 1597 1597 = 4. Use AT Command = 1598 1598 1604 + 1599 1599 == 4.1 Access AT Command == 1600 1600 1601 1601 ... ... @@ -1806,8 +1806,10 @@ 1806 1806 ))) 1807 1807 1808 1808 1815 + 1809 1809 == 4.2 Common AT Command Sequence == 1810 1810 1818 + 1811 1811 === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1812 1812 1813 1813 ((( ... ... @@ -1852,6 +1852,7 @@ 1852 1852 ))) 1853 1853 1854 1854 1863 + 1855 1855 === 4.2.2 Single-channel ABP mode (Use with LG01/LG02) === 1856 1856 1857 1857 ((( ... ... @@ -1937,6 +1937,7 @@ 1937 1937 1938 1938 ))) 1939 1939 1949 + 1940 1940 === 4.2.3 Change to Class A === 1941 1941 1942 1942 ... ... @@ -1948,8 +1948,10 @@ 1948 1948 ))) 1949 1949 1950 1950 1961 + 1951 1951 = 5. FAQ = 1952 1952 1964 + 1953 1953 == 5.1 How to upgrade the image? == 1954 1954 1955 1955 ... ... @@ -1993,6 +1993,8 @@ 1993 1993 1994 1994 ((( 1995 1995 ((( 2008 + 2009 + 1996 1996 == 5.2 How to change the LoRa Frequency Bands/Region? == 1997 1997 1998 1998 ... ... @@ -2006,6 +2006,7 @@ 2006 2006 ((( 2007 2007 2008 2008 2023 + 2009 2009 == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 2010 2010 2011 2011 ... ... @@ -2069,6 +2069,7 @@ 2069 2069 [[image:1653360498588-932.png||height="485" width="726"]] 2070 2070 2071 2071 2087 + 2072 2072 == 5.4 Can I see counting event in Serial? == 2073 2073 2074 2074 ... ... @@ -2076,11 +2076,13 @@ 2076 2076 User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 2077 2077 2078 2078 2095 + 2079 2079 == 5.5 Can i use point to point communication for LT-22222-L? == 2080 2080 2081 2081 2082 -Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https:// github.com/dragino/LT-22222-L/releases]].2099 +Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AADKXQ2v5ZT-S3sxdmbvE7UAa/LT-22222-L/image?dl=0&subfolder_nav_tracking=1]]. 2083 2083 2101 + 2084 2084 2085 2085 ))) 2086 2086 ... ... @@ -2097,6 +2097,7 @@ 2097 2097 After restart, the status before power failure will be read from flash. 2098 2098 2099 2099 2118 + 2100 2100 == 5.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? == 2101 2101 2102 2102 ... ... @@ -2106,13 +2106,14 @@ 2106 2106 [[image:image-20221006170630-1.png||height="610" width="945"]] 2107 2107 2108 2108 2109 -== 5.8 Can LT22222 -Lsave RO state? ==2128 +== 5.8 Can LT22222 save RO state? == 2110 2110 2111 - 2112 2112 Firmware version needs to be no less than 1.6.0. 2113 2113 2114 2114 2115 2115 = 6. Trouble Shooting = 2134 + 2135 + 2116 2116 ))) 2117 2117 2118 2118 ((( ... ... @@ -2130,6 +2130,7 @@ 2130 2130 ((( 2131 2131 2132 2132 2153 + 2133 2133 == 6.2 Have trouble to upload image. == 2134 2134 2135 2135 ... ... @@ -2142,6 +2142,7 @@ 2142 2142 ((( 2143 2143 2144 2144 2166 + 2145 2145 == 6.3 Why I can't join TTN in US915 /AU915 bands? == 2146 2146 2147 2147 ... ... @@ -2152,6 +2152,7 @@ 2152 2152 ))) 2153 2153 2154 2154 2177 + 2155 2155 = 7. Order Info = 2156 2156 2157 2157 ... ... @@ -2169,8 +2169,6 @@ 2169 2169 * (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 2170 2170 * (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 2171 2171 2172 - 2173 - 2174 2174 = 8. Packing Info = 2175 2175 2176 2176 ... ... @@ -2188,8 +2188,8 @@ 2188 2188 * Package Size / pcs : 14.5 x 8 x 5 cm 2189 2189 * Weight / pcs : 170g 2190 2190 2212 + 2191 2191 2192 - 2193 2193 = 9. Support = 2194 2194 2195 2195 ... ... @@ -2200,6 +2200,7 @@ 2200 2200 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 2201 2201 2202 2202 2224 + 2203 2203 2204 2204 ))) 2205 2205 ... ... @@ -2209,5 +2209,3 @@ 2209 2209 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2210 2210 * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 2211 2211 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 2212 - 2213 -
- image-20221112174847-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -102.6 KB - Content