Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
From version 111.1
edited by Bei Jinggeng
on 2023/01/10 17:26
on 2023/01/10 17:26
Change comment:
There is no comment for this version
To version 123.1
edited by Bei Jinggeng
on 2023/06/16 16:46
on 2023/06/16 16:46
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -26,7 +26,7 @@ 26 26 ))) 27 27 28 28 ((( 29 -The LT I/O Controllers allows the user to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection,building automation, and so on.29 +The LT I/O Controllers allows the user to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, building automation, and so on. 30 30 ))) 31 31 32 32 ((( ... ... @@ -176,11 +176,17 @@ 176 176 177 177 178 178 * LoRaWAN Class A & Class C protocol 179 + 179 179 * Optional Customized LoRa Protocol 181 + 180 180 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865/MA869 183 + 181 181 * AT Commands to change parameters 185 + 182 182 * Remote configure parameters via LoRa Downlink 187 + 183 183 * Firmware upgradable via program port 189 + 184 184 * Counting 185 185 186 186 ... ... @@ -188,10 +188,15 @@ 188 188 189 189 190 190 * Smart Buildings & Home Automation 197 + 191 191 * Logistics and Supply Chain Management 199 + 192 192 * Smart Metering 201 + 193 193 * Smart Agriculture 203 + 194 194 * Smart Cities 205 + 195 195 * Smart Factory 196 196 197 197 ... ... @@ -198,9 +198,12 @@ 198 198 == 1.5 Hardware Variants == 199 199 200 200 201 -(% border="1" style="background-color:#f7faff; width:500px" %) 202 -|(% style="width:103px" %)**Model**|(% style="width:131px" %)**Photo**|(% style="width:334px" %)**Description** 203 -|(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)[[image:1653296302983-697.png]]|(% style="width:334px" %)((( 212 +(% border="1" style="background-color:#f2f2f2; width:500px" %) 213 +|(% style="background-color:#d9e2f3; color:#0070c0; width:103px" %)**Model**|(% style="background-color:#d9e2f3; color:#0070c0; width:131px" %)**Photo**|(% style="background-color:#d9e2f3; color:#0070c0; width:334px" %)**Description** 214 +|(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)((( 215 +(% style="text-align:center" %) 216 +[[image:image-20230424115112-1.png||height="106" width="58"]] 217 +)))|(% style="width:334px" %)((( 204 204 * 2 x Digital Input (Bi-direction) 205 205 * 2 x Digital Output 206 206 * 2 x Relay Output (5A@250VAC / 30VDC) ... ... @@ -266,7 +266,7 @@ 266 266 Each LT is shipped with a sticker with the default device EUI as below: 267 267 ))) 268 268 269 -[[image: 1653297924498-393.png]]283 +[[image:image-20230425173427-2.png||height="246" width="530"]] 270 270 271 271 272 272 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: ... ... @@ -297,10 +297,15 @@ 297 297 There are five working modes + one interrupt mode on LT for different type application: 298 298 299 299 * (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO 314 + 300 300 * (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO 316 + 301 301 * (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO 318 + 302 302 * (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO 320 + 303 303 * (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 322 + 304 304 * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 305 305 306 306 ... ... @@ -308,19 +308,31 @@ 308 308 309 309 310 310 ((( 311 -The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. 330 +The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. (% style="display:none" %) 331 + 332 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 333 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1** 334 +|Value|((( 335 +AVI1 voltage 336 +)))|((( 337 +AVI2 voltage 338 +)))|((( 339 +ACI1 Current 340 +)))|((( 341 +ACI2 Current 342 +)))|DIDORO*|((( 343 +Reserve 344 +)))|MOD 312 312 ))) 313 313 314 -[[image:image-20220523174024-3.png]] 315 - 316 316 ((( 317 - 318 - 319 319 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 349 + 350 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 351 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 352 +|RO1|RO2|DI3|DI2|DI1|DO3|DO2|DO1 320 320 ))) 321 321 322 -[[image:image-20220523174254-4.png]] 323 - 324 324 * RO is for relay. ROx=1 : close,ROx=0 always open. 325 325 * DI is for digital input. DIx=1: high or float, DIx=0: low. 326 326 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. ... ... @@ -370,18 +370,24 @@ 370 370 371 371 ((( 372 372 Total : 11 bytes payload 404 + 405 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 406 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1** 407 +|Value|COUNT1|COUNT2 |DIDORO*|((( 408 +Reserve 409 +)))|MOD 373 373 ))) 374 374 375 -[[image:image-20220523180452-3.png]] 376 - 377 - 378 378 ((( 379 379 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 380 -))) 381 381 382 -[[image:image-20220523180506-4.png]] 415 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 416 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 417 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 383 383 384 -* RO is for relay. ROx=1 : close,ROx=0 always open. 419 +RO is for relay. ROx=1 : close,ROx=0 always open. 420 +))) 421 + 385 385 * FIRST: Indicate this is the first packet after join network. 386 386 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 387 387 ... ... @@ -412,14 +412,11 @@ 412 412 413 413 414 414 (% style="color:#4f81bd" %)**AT Commands for counting:** 415 - 416 - 417 417 ))) 418 418 419 419 ((( 420 420 **For LT22222-L:** 421 421 422 - 423 423 (% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger on low level, valid signal is 100ms) ** 424 424 425 425 (% style="color:blue" %)**AT+TRIG1=1,100**(%%)** (set DI1 port to trigger on high level, valid signal is 100ms ) ** ... ... @@ -439,16 +439,22 @@ 439 439 440 440 **LT22222-L**: This mode the DI1 is used as a counting pin. 441 441 442 -[[image:image-20220523181246-5.png]] 476 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 477 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1** 478 +|Value|COUNT1|((( 479 +ACI1 Current 480 +)))|((( 481 +ACI2 Current 482 +)))|DIDORO*|Reserve|MOD 443 443 444 444 ((( 445 - 446 - 447 447 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 486 + 487 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 488 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 489 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 448 448 ))) 449 449 450 -[[image:image-20220523181301-6.png]] 451 - 452 452 * RO is for relay. ROx=1 : close,ROx=0 always open. 453 453 * FIRST: Indicate this is the first packet after join network. 454 454 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. ... ... @@ -489,17 +489,22 @@ 489 489 490 490 ((( 491 491 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. 532 + 533 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 534 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1** 535 +|Value|COUNT1|AVI1 Counting|DIDORO*|((( 536 +Reserve 537 +)))|MOD 492 492 ))) 493 493 494 -[[image:image-20220523181903-8.png]] 495 - 496 - 497 497 ((( 498 498 (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 542 + 543 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 544 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 545 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 499 499 ))) 500 500 501 -[[image:image-20220523181727-7.png]] 502 - 503 503 * RO is for relay. ROx=1 : close,ROx=0 always open. 504 504 * FIRST: Indicate this is the first packet after join network. 505 505 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. ... ... @@ -533,11 +533,8 @@ 533 533 ))) 534 534 535 535 ((( 536 - 537 - 538 538 **Plus below command for AVI1 Counting:** 539 539 540 - 541 541 (% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 542 542 543 543 (% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** ... ... @@ -553,12 +553,24 @@ 553 553 554 554 **LT22222-L**: This mode the DI1 is used as a counting pin. 555 555 556 -[[image:image-20220523182334-9.png]] 598 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 599 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1** 600 +|Value|((( 601 +AVI1 voltage 602 +)))|((( 603 +AVI2 voltage 604 +)))|((( 605 +ACI1 Current 606 +)))|COUNT1|DIDORO*|((( 607 +Reserve 608 +)))|MOD 557 557 558 558 ((( 559 - 560 - 561 561 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 612 + 613 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 614 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 615 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 562 562 ))) 563 563 564 564 * RO is for relay. ROx=1 : close,ROx=0 always open. ... ... @@ -649,7 +649,6 @@ 649 649 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 650 650 651 651 652 - 653 653 (% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 654 654 655 655 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** ... ... @@ -684,12 +684,39 @@ 684 684 685 685 MOD6 Payload : total 11 bytes payload 686 686 687 -[[image:image-20220524085923-1.png]] 740 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 741 +|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:110px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**6**|(% style="background-color:#d9e2f3; color:#0070c0; width:110px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**1** 742 +|Value|((( 743 +TRI_A FLAG 744 +)))|((( 745 +TRI_A Status 746 +)))|((( 747 +TRI_DI FLAG+STA 748 +)))|Reserve|Enable/Disable MOD6|((( 749 +MOD(6) 750 +))) 688 688 689 - 690 690 (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below 691 691 692 -[[image:image-20220524090106-2.png]] 754 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 755 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 756 +|((( 757 +AV1_LOW 758 +)))|((( 759 +AV1_HIGH 760 +)))|((( 761 +AV2_LOW 762 +)))|((( 763 +AV2_HIGH 764 +)))|((( 765 +AC1_LOW 766 +)))|((( 767 +AC1_HIGH 768 +)))|((( 769 +AC2_LOW 770 +)))|((( 771 +AC2_HIGH 772 +))) 693 693 694 694 * Each bits shows if the corresponding trigger has been configured. 695 695 ... ... @@ -698,10 +698,27 @@ 698 698 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW 699 699 700 700 701 - 702 702 (% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1byte as below 703 703 704 -[[image:image-20220524090249-3.png]] 783 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 784 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 785 +|((( 786 +AV1_LOW 787 +)))|((( 788 +AV1_HIGH 789 +)))|((( 790 +AV2_LOW 791 +)))|((( 792 +AV2_HIGH 793 +)))|((( 794 +AC1_LOW 795 +)))|((( 796 +AC1_HIGH 797 +)))|((( 798 +AC2_LOW 799 +)))|((( 800 +AC2_HIGH 801 +))) 705 705 706 706 * Each bits shows which status has been trigger on this uplink. 707 707 ... ... @@ -710,10 +710,11 @@ 710 710 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. 711 711 712 712 713 - 714 714 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 715 715 716 -[[image:image-20220524090456-4.png]] 812 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 813 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 814 +|N/A|N/A|N/A|N/A|DI2_STATUS|DI2_FLAG|DI1_STATUS|DI1_FLAG 717 717 718 718 * Each bits shows which status has been trigger on this uplink. 719 719 ... ... @@ -724,7 +724,6 @@ 724 724 00000101: Means both DI1 and DI2 trigger are enabled. 725 725 726 726 727 - 728 728 (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable. 729 729 730 730 Downlink command to poll MOD6 status: ... ... @@ -795,14 +795,10 @@ 795 795 796 796 Set work mode. 797 797 798 -* (% style="color:#037691" %)**AT Command:** 895 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+MOD=N ** 799 799 800 -(% style="color:blue" %)**AT+MOD=N ** 801 - 802 - 803 803 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 804 804 805 - 806 806 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 807 807 808 808 (% style="color:blue" %)**0x0A aa **(%%)** ** ~/~/ Same as AT+MOD=aa ... ... @@ -812,16 +812,12 @@ 812 812 ==== 3.4.2.3 Poll an uplink ==== 813 813 814 814 815 -* (% style="color:#037691" %)**AT Command:** 908 +* (% style="color:#037691" %)**AT Command:**(%%) There is no AT Command to poll uplink 816 816 817 -There is no AT Command to poll uplink 818 - 819 - 820 820 * (% style="color:#037691" %)**Downlink Payload (prefix 0x08):** 821 821 822 822 (% style="color:blue" %)**0x08 FF **(%%)** **~/~/ Poll an uplink 823 823 824 - 825 825 **Example**: 0x08FF, ask device to send an Uplink 826 826 827 827 ... ... @@ -831,10 +831,8 @@ 831 831 832 832 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 833 833 834 -* (% style="color:#037691" %)**AT Command:** 923 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+ADDMOD6=1 or 0** 835 835 836 -(% style="color:blue" %)**AT+ADDMOD6=1 or 0** 837 - 838 838 (% style="color:red" %)**1:** (%%)Enable Trigger Mode 839 839 840 840 (% style="color:red" %)**0: **(%%)Disable Trigger Mode ... ... @@ -849,13 +849,12 @@ 849 849 ==== 3.4.2.5 Poll trigger settings ==== 850 850 851 851 852 -Poll trigger settings ,939 +Poll trigger settings 853 853 854 854 * (% style="color:#037691" %)**AT Command:** 855 855 856 856 There is no AT Command for this feature. 857 857 858 - 859 859 * (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 860 860 861 861 (% style="color:blue" %)**0xAB 06 ** (%%) ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command ... ... @@ -867,15 +867,11 @@ 867 867 868 868 Enable Disable DI1/DI2/DI2 as trigger, 869 869 870 -* (% style="color:#037691" %)**AT Command:** 956 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 871 871 872 - (% style="color:blue" %)**Format:AT+DTRI=<DI1_TIRGGER_FlAG>,<DI2_TIRGGER_FlAG>**958 +**Example:** AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 873 873 874 874 875 -**Example:** 876 - 877 -AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 878 - 879 879 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 880 880 881 881 (% style="color:blue" %)**0xAA 02 aa bb ** (%%) ~/~/ Same as AT+DTRI=aa,bb ... ... @@ -887,20 +887,15 @@ 887 887 888 888 Set DI1 or DI3(for LT-33222-L) trigger. 889 889 890 -* (% style="color:#037691" %)**AT Command:** 972 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+TRIG1=a,b** 891 891 892 -(% style="color:blue" %)**AT+TRIG1=a,b** 893 - 894 894 (% style="color:red" %)**a :** (%%)Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 895 895 896 896 (% style="color:red" %)**b :** (%%)delay timing. 897 897 978 +**Example:** AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 898 898 899 -**Example:** 900 900 901 -AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 902 - 903 - 904 904 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 905 905 906 906 (% style="color:blue" %)**0x09 01 aa bb cc ** (%%) ~/~/ same as AT+TRIG1=aa,0x(bb cc) ... ... @@ -912,20 +912,15 @@ 912 912 913 913 Set DI2 trigger. 914 914 915 -* (% style="color:#037691" %)**AT Command:** 992 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+TRIG2=a,b** 916 916 917 -(% style="color:blue" %)**AT+TRIG2=a,b** 918 - 919 919 (% style="color:red" %)**a :** (%%)Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 920 920 921 921 (% style="color:red" %)**b :** (%%)delay timing. 922 922 998 +**Example:** AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 923 923 924 -**Example:** 925 925 926 -AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 927 - 928 - 929 929 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 930 930 931 931 (% style="color:blue" %)**0x09 02 aa bb cc ** (%%)~/~/ same as AT+TRIG2=aa,0x(bb cc) ... ... @@ -937,11 +937,8 @@ 937 937 938 938 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 939 939 940 -* (% style="color:#037691" %)**AT Command** 1012 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+ACLIM** 941 941 942 -(% style="color:blue" %)**AT+ACLIM** 943 - 944 - 945 945 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )** 946 946 947 947 (% style="color:blue" %)**0x AA 01 aa bb cc dd ee ff gg hh ** (%%) ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -953,11 +953,8 @@ 953 953 954 954 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 955 955 956 -* (% style="color:#037691" %)**AT Command** 1025 +* (% style="color:#037691" %)**AT Command**(%%): (% style="color:blue" %)**AT+AVLIM **(%%)** See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 957 957 958 -(% style="color:blue" %)**AT+AVLIM **(%%)** See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 959 - 960 - 961 961 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )** 962 962 963 963 (% style="color:blue" %)**0x AA 00 aa bb cc dd ee ff gg hh ** (%%) ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -969,18 +969,13 @@ 969 969 970 970 Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 971 971 972 -* (% style="color:#037691" %)**AT Command** 1038 +* (% style="color:#037691" %)**AT Command**(%%): (% style="color:blue" %)**AT+ATDC=5 ** ~/~/ (%%)Device won't response the second trigger within 5 minute after the first trigger. 973 973 974 -(% style="color:blue" %)**AT+ATDC=5 ** (%%)Device won't response the second trigger within 5 minute after the first trigger. 975 - 976 - 977 977 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** 978 978 979 979 (% style="color:blue" %)**0x AC aa bb **(%%) ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 980 980 981 981 ((( 982 - 983 - 984 984 (% style="color:red" %)**Note: ATDC setting must be more than 5min** 985 985 ))) 986 986 ... ... @@ -995,8 +995,9 @@ 995 995 996 996 997 997 * (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 998 -* (% style="color:blue" %)**0x02 aa bb cc ** (%%)~/~/ Set DO1/DO2/DO3 output 999 999 1060 +(% style="color:blue" %)**0x02 aa bb cc ** (%%)~/~/ Set DO1/DO2/DO3 output 1061 + 1000 1000 ((( 1001 1001 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 1002 1002 ))) ... ... @@ -1003,10 +1003,14 @@ 1003 1003 1004 1004 ((( 1005 1005 01: Low, 00: High , 11: No action 1068 + 1069 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 1070 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Downlink Code**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO3** 1071 +|02 01 00 11|Low|High|No Action 1072 +|02 00 11 01|High|No Action|Low 1073 +|02 11 01 00|No Action|Low|High 1006 1006 ))) 1007 1007 1008 -[[image:image-20220524092754-5.png]] 1009 - 1010 1010 ((( 1011 1011 (% style="color:red" %)**Note: For LT-22222-L, there is no DO3, the last byte can use any value.** 1012 1012 ))) ... ... @@ -1043,30 +1043,37 @@ 1043 1043 1044 1044 (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status: 1045 1045 1046 -[[image:image-20220524093238-6.png]] 1112 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1113 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status** 1114 +|0x01|DO1 set to low 1115 +|0x00|DO1 set to high 1116 +|0x11|DO1 NO Action 1047 1047 1048 - 1049 1049 (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status: 1050 1050 1051 -[[image:image-20220524093328-7.png]] 1120 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1121 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status** 1122 +|0x01|DO2 set to low 1123 +|0x00|DO2 set to high 1124 +|0x11|DO2 NO Action 1052 1052 1053 - 1054 1054 (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status: 1055 1055 1056 -[[image:image-20220524093351-8.png]] 1128 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1129 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status** 1130 +|0x01|DO3 set to low 1131 +|0x00|DO3 set to high 1132 +|0x11|DO3 NO Action 1057 1057 1134 +(% style="color:#4f81bd" %)**Sixth and Seventh and Eighth and Ninth Byte**:(%%) Latching time. Unit: ms 1058 1058 1059 -(% style="color:#4f81bd" %)**Sixth and Seventh and Eighth and Ninth Byte**: 1060 1060 1061 - Latching time.Unit:ms1137 +(% style="color:red" %)**Note: ** 1062 1062 1063 -Note: 1064 - 1065 1065 Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1066 1066 1067 1067 Before Firmwre v1.6.0 the latch time only suport 2 bytes. 1068 1068 1069 - 1070 1070 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1071 1071 1072 1072 ... ... @@ -1090,7 +1090,7 @@ 1090 1090 1091 1091 1092 1092 1093 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1166 +==== 3.4.2. 14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1094 1094 1095 1095 1096 1096 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1109,10 +1109,17 @@ 1109 1109 1110 1110 ((( 1111 1111 01: Close , 00: Open , 11: No action 1112 -))) 1113 1113 1114 -((( 1115 -[[image:image-20220524093724-9.png]] 1186 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:320px" %) 1187 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Downlink Code**|(% style="background-color:#d9e2f3; color:#0070c0" %)**RO1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**RO2** 1188 +|03 00 11|Open|No Action 1189 +|03 01 11|Close|No Action 1190 +|03 11 00|No Action|Open 1191 +|03 11 01|No Action|Close 1192 +|03 00 00|Open|Open 1193 +|03 01 01|Close|Close 1194 +|03 01 00|Close|Open 1195 +|03 00 01|Open|Close 1116 1116 ))) 1117 1117 1118 1118 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** ... ... @@ -1150,8 +1150,9 @@ 1150 1150 1151 1151 (% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms 1152 1152 1153 -Note: 1154 1154 1234 +(% style="color:red" %)**Note:** 1235 + 1155 1155 Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1156 1156 1157 1157 Before Firmwre v1.6.0 the latch time only suport 2 bytes. ... ... @@ -1185,11 +1185,8 @@ 1185 1185 1186 1186 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1187 1187 1188 -* (% style="color:#037691" %)**AT Command:** 1269 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+VOLMAX ** (%%)~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1189 1189 1190 -(% style="color:blue" %)**AT+VOLMAX ** (%%)~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1191 - 1192 - 1193 1193 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1194 1194 1195 1195 (% style="color:blue" %)**0xA5 aa bb cc ** (%%)~/~/ Same as AT+VOLMAX=(aa bb),cc ... ... @@ -1199,10 +1199,8 @@ 1199 1199 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1200 1200 1201 1201 1202 -* (% style="color:#037691" %)**AT Command:** 1280 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+SETCNT=aa,(bb cc dd ee) ** 1203 1203 1204 -(% style="color:blue" %)**AT+SETCNT=aa,(bb cc dd ee) ** 1205 - 1206 1206 (% style="color:red" %)**aa:**(%%) 1: Set count1; 2: Set count2; 3: Set AV1 count 1207 1207 1208 1208 (% style="color:red" %)**bb cc dd ee: **(%%)number to be set ... ... @@ -1219,11 +1219,8 @@ 1219 1219 1220 1220 Clear counting for counting mode 1221 1221 1222 -* (% style="color:#037691" %)**AT Command:** 1298 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+CLRCOUNT **(%%) ~/~/ clear all counting 1223 1223 1224 -(% style="color:blue" %)**AT+CLRCOUNT **(%%) ~/~/ clear all counting 1225 - 1226 - 1227 1227 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1228 1228 1229 1229 (% style="color:blue" %)**0x A6 01 ** (%%)~/~/ clear all counting ... ... @@ -1375,7 +1375,7 @@ 1375 1375 1376 1376 (% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices. 1377 1377 1378 -(% style="color:blue" %)**Step 4**(%%): Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)1451 +(% style="color:blue" %)**Step 4**(%%): Search LT-22222-L(for both LT-22222-L) and add DevEUI.(% style="display:none" %) 1379 1379 1380 1380 Search under The things network 1381 1381 ... ... @@ -1530,9 +1530,9 @@ 1530 1530 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1531 1531 1532 1532 1533 -**NPN output**: GND or Float. Max voltage can apply to output pin is 36v. 1606 +(% style="color:blue" %)**NPN output**(%%): GND or Float. Max voltage can apply to output pin is 36v. 1534 1534 1535 -Note: DO pins go to float when device is power off. 1608 +(% style="color:red" %)**Note: DO pins go to float when device is power off.** 1536 1536 1537 1537 [[image:1653357531600-905.png]] 1538 1538 ... ... @@ -1554,13 +1554,12 @@ 1554 1554 1555 1555 (% style="color:blue" %)**Specifications of the wind speed sensor:** 1556 1556 1557 -**Red: 12~~24v** 1630 +(% style="color:red" %)**Red: 12~~24v** 1558 1558 1559 -**Yellow: 4~~20mA** 1632 +(% style="color:#ffc000" %)**Yellow: 4~~20mA** 1560 1560 1561 1561 **Black: GND** 1562 1562 1563 - 1564 1564 **Connection diagram:** 1565 1565 1566 1566 [[image:1653357640609-758.png]] ... ... @@ -1568,6 +1568,22 @@ 1568 1568 [[image:1653357648330-671.png||height="155" width="733"]] 1569 1569 1570 1570 1643 +Example connected to a regulated power supply to measure voltage 1644 + 1645 +[[image:image-20230608101532-1.png||height="606" width="447"]] 1646 + 1647 +[[image:image-20230608101608-2.jpeg||height="379" width="284"]] 1648 + 1649 +[[image:image-20230608101722-3.png||height="102" width="1139"]] 1650 + 1651 + 1652 +(% style="color:blue; font-weight:bold" %)**Specifications of the regulated power**(%%) (% style="color:blue" %)**:** 1653 + 1654 +(% style="color:red" %)**Red: 12~~24v** 1655 + 1656 +**Black: GND** 1657 + 1658 + 1571 1571 === 3.6.5 Relay Output === 1572 1572 1573 1573 ... ... @@ -1586,9 +1586,42 @@ 1586 1586 == 3.7 LEDs Indicators == 1587 1587 1588 1588 1589 -[[image:image-20220524100748-11.png]] 1677 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 1678 +|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**LEDs**|(% style="background-color:#d9e2f3; color:#0070c0; width:470px" %)**Feature** 1679 +|**PWR**|Always on if there is power 1680 +|**SYS**|((( 1681 +After device is powered on, the SYS will **fast blink in GREEN** for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be **on GREEN for 5 seconds. **SYS will **blink Blue** on every upload and **blink Green** once receive a downlink message. 1682 +))) 1683 +|**TX**|((( 1684 +((( 1685 +Device boot: TX blinks 5 times. 1686 +))) 1590 1590 1688 +((( 1689 +Successful join network: TX ON for 5 seconds. 1690 +))) 1591 1591 1692 +((( 1693 +Transmit a LoRa packet: TX blinks once 1694 +))) 1695 +))) 1696 +|**RX**|RX blinks once when receive a packet. 1697 +|**DO1**| 1698 +|**DO2**| 1699 +|**DO3**| 1700 +|**DI2**|((( 1701 +For LT-22222-L: ON when DI2 is high, LOW when DI2 is low 1702 +))) 1703 +|**DI2**|((( 1704 +For LT-22222-L: ON when DI2 is high, LOW when DI2 is low 1705 +))) 1706 +|**DI2**|((( 1707 +For LT-22222-L: ON when DI2 is high, LOW when DI2 is low 1708 +))) 1709 +|**RO1**| 1710 +|**RO2**| 1711 + 1712 + 1592 1592 = 4. Use AT Command = 1593 1593 1594 1594 == 4.1 Access AT Command == ... ... @@ -1919,7 +1919,7 @@ 1919 1919 **3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php? 1920 1920 dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.** 1921 1921 1922 -**4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5** 2043 +**4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5.** 1923 1923 1924 1924 1925 1925 ))) ... ... @@ -1943,11 +1943,19 @@ 1943 1943 ))) 1944 1944 1945 1945 1946 -= 5. FAQ=2067 += 5. Case Study = 1947 1947 1948 -== 5.1 Howtoupgradetheimage?==2069 +== 5.1 Counting how many objects pass in Flow Line == 1949 1949 1950 1950 2072 +Reference Link: [[How to set up to count objects pass in flow line>>How to set up to count objects pass in flow line]]? 2073 + 2074 + 2075 += 6. FAQ = 2076 + 2077 +== 6.1 How to upgrade the image? == 2078 + 2079 + 1951 1951 The LT LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to LT to: 1952 1952 1953 1953 * Support new features ... ... @@ -1961,7 +1961,7 @@ 1961 1961 1962 1962 ((( 1963 1963 (% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1964 -(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>> url:https://www.dropbox.com/sh/g99v0fxcltn9r1y/AADKXQ2v5ZT-S3sxdmbvE7UAa/LT-22222-L/image?dl=0&subfolder_nav_tracking=1]].2093 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AACrbrDN0AqLHbBat0ViWx5Da/LT-22222-L/Firmware?dl=0&subfolder_nav_tracking=1]]. 1965 1965 (% style="color:blue" %)**Step3**(%%)**:** Open flashloader; choose the correct COM port to update. 1966 1966 1967 1967 ... ... @@ -1975,8 +1975,10 @@ 1975 1975 1976 1976 [[image:image-20220524103407-12.png]] 1977 1977 2107 + 1978 1978 [[image:image-20220524103429-13.png]] 1979 1979 2110 + 1980 1980 [[image:image-20220524104033-15.png]] 1981 1981 1982 1982 ... ... @@ -1988,7 +1988,7 @@ 1988 1988 1989 1989 ((( 1990 1990 ((( 1991 -== 5.2 How to change the LoRa Frequency Bands/Region? ==2122 +== 6.2 How to change the LoRa Frequency Bands/Region? == 1992 1992 1993 1993 1994 1994 ))) ... ... @@ -2001,7 +2001,7 @@ 2001 2001 ((( 2002 2002 2003 2003 2004 -== 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? ==2135 +== 6.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 2005 2005 2006 2006 2007 2007 ))) ... ... @@ -2064,14 +2064,20 @@ 2064 2064 [[image:1653360498588-932.png||height="485" width="726"]] 2065 2065 2066 2066 2067 -== 5.4CanIseecountingvent inSerial?==2198 +== 6.4 How to change the uplink interval? == 2068 2068 2069 2069 2201 +Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/]] 2202 + 2203 + 2204 +== 6.5 Can I see counting event in Serial? == 2205 + 2206 + 2070 2070 ((( 2071 2071 User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 2072 2072 2073 2073 2074 -== 5.5Can i use point to point communication for LT-22222-L? ==2211 +== 6.6 Can i use point to point communication for LT-22222-L? == 2075 2075 2076 2076 2077 2077 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https://github.com/dragino/LT-22222-L/releases]]. ... ... @@ -2080,7 +2080,7 @@ 2080 2080 ))) 2081 2081 2082 2082 ((( 2083 -== 5.62220 +== 6.7 Why does the relay output become the default and open relay after the lt22222 is powered off? == 2084 2084 2085 2085 2086 2086 If the device is not shut down, but directly powered off. ... ... @@ -2092,7 +2092,7 @@ 2092 2092 After restart, the status before power failure will be read from flash. 2093 2093 2094 2094 2095 -== 5.7Can i set up LT-22222-L as a NC(Normal Close) Relay? ==2232 +== 6.8 Can i set up LT-22222-L as a NC(Normal Close) Relay? == 2096 2096 2097 2097 2098 2098 LT-22222-L built-in relay is NO (Normal Open). User can use an external relay to achieve Normal Close purpose. Diagram as below: ... ... @@ -2101,18 +2101,18 @@ 2101 2101 [[image:image-20221006170630-1.png||height="610" width="945"]] 2102 2102 2103 2103 2104 -== 5.8Can LT22222-L save RO state? ==2241 +== 6.9 Can LT22222-L save RO state? == 2105 2105 2106 2106 2107 2107 Firmware version needs to be no less than 1.6.0. 2108 2108 2109 2109 2110 -= 6. Trouble Shooting =2247 += 7. Trouble Shooting = 2111 2111 ))) 2112 2112 2113 2113 ((( 2114 2114 ((( 2115 -== 6.1 Downlink doesn't work, how to solve it? ==2252 +== 7.1 Downlink doesn't work, how to solve it? == 2116 2116 2117 2117 2118 2118 ))) ... ... @@ -2125,7 +2125,7 @@ 2125 2125 ((( 2126 2126 2127 2127 2128 -== 6.2 Have trouble to upload image. ==2265 +== 7.2 Have trouble to upload image. == 2129 2129 2130 2130 2131 2131 ))) ... ... @@ -2137,7 +2137,7 @@ 2137 2137 ((( 2138 2138 2139 2139 2140 -== 6.3 Why I can't join TTN in US915 /AU915 bands? ==2277 +== 7.3 Why I can't join TTN in US915 /AU915 bands? == 2141 2141 2142 2142 2143 2143 ))) ... ... @@ -2147,7 +2147,7 @@ 2147 2147 ))) 2148 2148 2149 2149 2150 -= 7. Order Info =2287 += 8. Order Info = 2151 2151 2152 2152 2153 2153 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** ... ... @@ -2165,7 +2165,7 @@ 2165 2165 * (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 2166 2166 2167 2167 2168 -= 8. Packing Info =2305 += 9. Packing Info = 2169 2169 2170 2170 2171 2171 **Package Includes**: ... ... @@ -2183,7 +2183,7 @@ 2183 2183 * Weight / pcs : 170g 2184 2184 2185 2185 2186 -= 9. Support =2323 += 10. Support = 2187 2187 2188 2188 2189 2189 * ((( ... ... @@ -2190,13 +2190,13 @@ 2190 2190 Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 2191 2191 ))) 2192 2192 * ((( 2193 -Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]2330 +Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]] 2194 2194 2195 2195 2196 2196 2197 2197 ))) 2198 2198 2199 -= 1 0. Reference =2336 += 11. Reference = 2200 2200 2201 2201 2202 2202 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
- image-20230424115112-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.1 KB - Content
- image-20230425173351-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +207.8 KB - Content
- image-20230425173427-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +150.1 KB - Content
- image-20230426161322-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.2 KB - Content
- image-20230608101532-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +563.0 KB - Content
- image-20230608101608-2.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +287.8 KB - Content
- image-20230608101722-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.4 KB - Content