... ... @@ -183,8 +183,6 @@
183 183  * Firmware upgradable via program port
184 184  * Counting
185 185  
186 -
187 -
188 188  == 1.4  Applications ==
189 189  
190 190  
... ... @@ -195,8 +195,6 @@
195 195  * Smart Cities
196 196  * Smart Factory
197 197  
198 -
199 -
200 200  == 1.5 Hardware Variants ==
201 201  
202 202  
... ... @@ -211,8 +211,6 @@
211 211  * 1 x Counting Port
212 212  )))
213 213  
214 -
215 -
216 216  = 2. Power ON Device =
217 217  
218 218  
... ... @@ -306,8 +306,6 @@
306 306  * (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
307 307  * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
308 308  
309 -
310 -
311 311  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
312 312  
313 313  
... ... @@ -364,8 +364,6 @@
364 364  ** DO1 is high in case there is load between DO1 and V+.
365 365  ** DO1 LED is off in both case
366 366  
367 -
368 -
369 369  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
370 370  
371 371  
... ... @@ -654,7 +654,6 @@
654 654  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
655 655  
656 656  
657 -
658 658  (% style="color:#037691" %)**Downlink Command to set Trigger Condition:**
659 659  
660 660  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
... ... @@ -715,7 +715,6 @@
715 715  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
716 716  
717 717  
718 -
719 719  (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below
720 720  
721 721  [[image:image-20220524090456-4.png]]
... ... @@ -729,7 +729,6 @@
729 729  00000101: Means both DI1 and DI2 trigger are enabled.
730 730  
731 731  
732 -
733 733  (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable.
734 734  
735 735  Downlink command to poll MOD6 status:
... ... @@ -765,8 +765,6 @@
765 765  
766 766  * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
767 767  
768 -
769 -
770 770  === 3.4.1 Common Commands ===
771 771  
772 772  
... ... @@ -1066,8 +1066,9 @@
1066 1066  
1067 1067   Latching time. Unit: ms
1068 1068  
1069 -Note:
1070 1070  
1055 +(% style="color:red" %)**Note: **
1056 +
1071 1071   Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes
1072 1072  
1073 1073   Before Firmwre v1.6.0 the latch time only suport 2 bytes.
... ... @@ -1096,7 +1096,7 @@
1096 1096  
1097 1097  
1098 1098  
1099 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1085 +==== 3.4.2. 14 Relay ~-~- Control Relay Output RO1/RO2 ====
1100 1100  
1101 1101  
1102 1102  * (% style="color:#037691" %)**AT Command:**
... ... @@ -1156,8 +1156,9 @@
1156 1156  
1157 1157  (% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms
1158 1158  
1159 -Note:
1160 1160  
1146 +(% style="color:red" %)**Note:**
1147 +
1161 1161   Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes
1162 1162  
1163 1163   Before Firmwre v1.6.0 the latch time only suport 2 bytes.
... ... @@ -1168,7 +1168,7 @@
1168 1168  
1169 1169  **Example payload:**
1170 1170  
1171 -**~1. 05 01 11 07 D**
1158 +**~1. 05 01 11 07 D0**
1172 1172  
1173 1173  Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state.
1174 1174  
... ... @@ -1949,11 +1949,19 @@
1949 1949  )))
1950 1950  
1951 1951  
1952 -= 5. FAQ =
1939 += 5. Case Study =
1953 1953  
1954 -== 5.1 How to upgrade the image? ==
1941 +== 5.1 Counting how many objects pass in Flow Line ==
1955 1955  
1956 1956  
1944 +Reference Link: [[How to set up to count objects pass in flow line>>How to set up to count objects pass in flow line]]?
1945 +
1946 +
1947 += 6. FAQ =
1948 +
1949 +== 6.1 How to upgrade the image? ==
1950 +
1951 +
1957 1957  The LT LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to LT to:
1958 1958  
1959 1959  * Support new features
... ... @@ -1994,7 +1994,7 @@
1994 1994  
1995 1995  (((
1996 1996  (((
1997 -== 5.2 How to change the LoRa Frequency Bands/Region? ==
1992 +== 6.2 How to change the LoRa Frequency Bands/Region? ==
1998 1998  
1999 1999  
2000 2000  )))
... ... @@ -2007,7 +2007,7 @@
2007 2007  (((
2008 2008  
2009 2009  
2010 -== 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? ==
2005 +== 6.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? ==
2011 2011  
2012 2012  
2013 2013  )))
... ... @@ -2070,7 +2070,7 @@
2070 2070  [[image:1653360498588-932.png||height="485" width="726"]]
2071 2071  
2072 2072  
2073 -== 5.4 Can I see counting event in Serial? ==
2068 +== 6.4 Can I see counting event in Serial? ==
2074 2074  
2075 2075  
2076 2076  (((
... ... @@ -2077,7 +2077,7 @@
2077 2077  User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first.
2078 2078  
2079 2079  
2080 -== 5.5 Can i use point to point communication for LT-22222-L? ==
2075 +== 6.5 Can i use point to point communication for LT-22222-L? ==
2081 2081  
2082 2082  
2083 2083  Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]  ,this is [[firmware>>https://github.com/dragino/LT-22222-L/releases]].
... ... @@ -2086,7 +2086,7 @@
2086 2086  )))
2087 2087  
2088 2088  (((
2089 -== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
2084 +== 6.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
2090 2090  
2091 2091  
2092 2092  If the device is not shut down, but directly powered off.
... ... @@ -2098,7 +2098,7 @@
2098 2098  After restart, the status before power failure will be read from flash.
2099 2099  
2100 2100  
2101 -== 5.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? ==
2096 +== 6.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? ==
2102 2102  
2103 2103  
2104 2104  LT-22222-L built-in relay is NO (Normal Open). User can use an external relay to achieve Normal Close purpose. Diagram as below:
... ... @@ -2107,18 +2107,18 @@
2107 2107  [[image:image-20221006170630-1.png||height="610" width="945"]]
2108 2108  
2109 2109  
2110 -== 5.8 Can LT22222-L save RO state? ==
2105 +== 6.8 Can LT22222-L save RO state? ==
2111 2111  
2112 2112  
2113 2113  Firmware version needs to be no less than 1.6.0.
2114 2114  
2115 2115  
2116 -= 6. Trouble Shooting =
2111 += 7. Trouble Shooting =
2117 2117  )))
2118 2118  
2119 2119  (((
2120 2120  (((
2121 -== 6.1 Downlink doesn't work, how to solve it? ==
2116 +== 7.1 Downlink doesn't work, how to solve it? ==
2122 2122  
2123 2123  
2124 2124  )))
... ... @@ -2131,7 +2131,7 @@
2131 2131  (((
2132 2132  
2133 2133  
2134 -== 6.2 Have trouble to upload image. ==
2129 +== 7.2 Have trouble to upload image. ==
2135 2135  
2136 2136  
2137 2137  )))
... ... @@ -2143,7 +2143,7 @@
2143 2143  (((
2144 2144  
2145 2145  
2146 -== 6.3 Why I can't join TTN in US915 /AU915 bands? ==
2141 +== 7.3 Why I can't join TTN in US915 /AU915 bands? ==
2147 2147  
2148 2148  
2149 2149  )))
... ... @@ -2153,7 +2153,7 @@
2153 2153  )))
2154 2154  
2155 2155  
2156 -= 7. Order Info =
2151 += 8. Order Info =
2157 2157  
2158 2158  
2159 2159  (% style="color:#4f81bd" %)**LT-22222-L-XXX:**
... ... @@ -2170,11 +2170,9 @@
2170 2170  * (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
2171 2171  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2172 2172  
2168 += 9. Packing Info =
2173 2173  
2174 2174  
2175 -= 8. Packing Info =
2176 -
2177 -
2178 2178  **Package Includes**:
2179 2179  
2180 2180  * LT-22222-L I/O Controller x 1
... ... @@ -2189,11 +2189,9 @@
2189 2189  * Package Size / pcs : 14.5 x 8 x 5 cm
2190 2190  * Weight / pcs : 170g
2191 2191  
2185 += 10. Support =
2192 2192  
2193 2193  
2194 -= 9. Support =
2195 -
2196 -
2197 2197  * (((
2198 2198  Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
2199 2199  )))
... ... @@ -2204,7 +2204,7 @@
2204 2204  
2205 2205  )))
2206 2206  
2207 -= 10. Reference​​​​​ =
2198 += 11. Reference​​​​​ =
2208 2208  
2209 2209  
2210 2210  * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
... ... @@ -2211,5 +2211,4 @@
2211 2211  * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]]
2212 2212  * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]]
2213 2213  
2214 -
2215 2215