<
From version < 110.1 >
edited by Bei Jinggeng
on 2022/12/22 09:19
To version < 111.1 >
edited by Bei Jinggeng
on 2023/01/10 17:26
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -15,7 +15,6 @@
15 15  
16 16  = 1.Introduction =
17 17  
18 -
19 19  == 1.1 What is LT Series I/O Controller ==
20 20  
21 21  (((
... ... @@ -54,7 +54,6 @@
54 54  
55 55  )))
56 56  
57 -
58 58  == 1.2  Specifications ==
59 59  
60 60  (((
... ... @@ -171,7 +171,6 @@
171 171  Packet engine up to 256 bytes with CRC.
172 172  
173 173  
174 -
175 175  
176 176  )))
177 177  
... ... @@ -294,7 +294,6 @@
294 294  [[image:1653298044601-602.png||height="405" width="709"]]
295 295  
296 296  
297 -
298 298  == 3.3 Uplink Payload ==
299 299  
300 300  
... ... @@ -850,7 +850,6 @@
850 850  
851 851  
852 852  
853 -
854 854  ==== 3.4.2.5 Poll trigger settings ====
855 855  
856 856  
... ... @@ -1124,7 +1124,6 @@
1124 1124  
1125 1125  
1126 1126  
1127 -
1128 1128  ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
1129 1129  
1130 1130  
... ... @@ -1168,7 +1168,7 @@
1168 1168  
1169 1169  **Example payload:**
1170 1170  
1171 -**~1. 05 01 11 07 D**
1165 +**~1. 05 01 11 07 D0**
1172 1172  
1173 1173  Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state.
1174 1174  
... ... @@ -1303,7 +1303,6 @@
1303 1303  
1304 1304  
1305 1305  
1306 -
1307 1307  ==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ====
1308 1308  
1309 1309  
... ... @@ -1320,7 +1320,6 @@
1320 1320  
1321 1321  
1322 1322  
1323 -
1324 1324  ==== 3.4.2.25 Copy downlink to uplink ====
1325 1325  
1326 1326  
... ... @@ -1474,8 +1474,6 @@
1474 1474  
1475 1475  (((
1476 1476  
1477 -
1478 -
1479 1479  )))
1480 1480  
1481 1481  (((
... ... @@ -1507,8 +1507,6 @@
1507 1507  
1508 1508  (((
1509 1509  
1510 -
1511 -
1512 1512  )))
1513 1513  
1514 1514  (((
... ... @@ -1601,7 +1601,6 @@
1601 1601  [[image:image-20220524100748-11.png]]
1602 1602  
1603 1603  
1604 -
1605 1605  = 4. Use AT Command =
1606 1606  
1607 1607  == 4.1 Access AT Command ==
... ... @@ -1945,7 +1945,6 @@
1945 1945  
1946 1946  )))
1947 1947  
1948 -
1949 1949  === 4.2.3 Change to Class A ===
1950 1950  
1951 1951  
... ... @@ -2216,3 +2216,5 @@
2216 2216  * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
2217 2217  * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]]
2218 2218  * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]]
2205 +
2206 +
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0