Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -186,8 +186,6 @@ 186 186 * Firmware upgradable via program port 187 187 * Counting 188 188 189 - 190 - 191 191 == 1.4 Applications == 192 192 193 193 ... ... @@ -198,8 +198,6 @@ 198 198 * Smart Cities 199 199 * Smart Factory 200 200 201 - 202 - 203 203 == 1.5 Hardware Variants == 204 204 205 205 ... ... @@ -214,8 +214,6 @@ 214 214 * 1 x Counting Port 215 215 ))) 216 216 217 - 218 - 219 219 = 2. Power ON Device = 220 220 221 221 ... ... @@ -232,8 +232,10 @@ 232 232 [[image:1653297104069-180.png]] 233 233 234 234 229 + 235 235 = 3. Operation Mode = 236 236 232 + 237 237 == 3.1 How it works? == 238 238 239 239 ... ... @@ -246,6 +246,7 @@ 246 246 ))) 247 247 248 248 245 + 249 249 == 3.2 Example to join LoRaWAN network == 250 250 251 251 ... ... @@ -310,8 +310,6 @@ 310 310 * (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 311 311 * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 312 312 313 - 314 - 315 315 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 316 316 317 317 ... ... @@ -368,8 +368,6 @@ 368 368 ** DO1 is high in case there is load between DO1 and V+. 369 369 ** DO1 LED is off in both case 370 370 371 - 372 - 373 373 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 374 374 375 375 ... ... @@ -443,6 +443,7 @@ 443 443 ))) 444 444 445 445 439 + 446 446 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 447 447 448 448 ... ... @@ -489,6 +489,7 @@ 489 489 ))) 490 490 491 491 486 + 492 492 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 493 493 494 494 ... ... @@ -557,6 +557,7 @@ 557 557 ))) 558 558 559 559 555 + 560 560 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 561 561 562 562 ... ... @@ -604,6 +604,7 @@ 604 604 ))) 605 605 606 606 603 + 607 607 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 608 608 609 609 ... ... @@ -743,6 +743,7 @@ 743 743 When device got this command, it will send the MOD6 payload. 744 744 745 745 743 + 746 746 === 3.3.7 Payload Decoder === 747 747 748 748 ((( ... ... @@ -752,6 +752,7 @@ 752 752 ))) 753 753 754 754 753 + 755 755 == 3.4 Configure LT via AT or Downlink == 756 756 757 757 ... ... @@ -769,8 +769,6 @@ 769 769 770 770 * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 771 771 772 - 773 - 774 774 === 3.4.1 Common Commands === 775 775 776 776 ... ... @@ -779,8 +779,10 @@ 779 779 ))) 780 780 781 781 779 + 782 782 === 3.4.2 Sensor related commands === 783 783 782 + 784 784 ==== 3.4.2.1 Set Transmit Interval ==== 785 785 786 786 ... ... @@ -1071,13 +1071,6 @@ 1071 1071 1072 1072 Latching time. Unit: ms 1073 1073 1074 -Note: 1075 - 1076 - Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1077 - 1078 - Before Firmwre v1.6.0 the latch time only suport 2 bytes. 1079 - 1080 - 1081 1081 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1082 1082 1083 1083 ... ... @@ -1162,13 +1162,6 @@ 1162 1162 1163 1163 (% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms 1164 1164 1165 -Note: 1166 - 1167 - Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1168 - 1169 - Before Firmwre v1.6.0 the latch time only suport 2 bytes. 1170 - 1171 - 1172 1172 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1173 1173 1174 1174 ... ... @@ -1365,6 +1365,7 @@ 1365 1365 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]] 1366 1366 1367 1367 1353 + 1368 1368 == 3.5 Integrate with Mydevice == 1369 1369 1370 1370 ... ... @@ -1414,8 +1414,10 @@ 1414 1414 [[image:image-20220524094909-5.png||height="341" width="734"]] 1415 1415 1416 1416 1403 + 1417 1417 == 3.6 Interface Detail == 1418 1418 1406 + 1419 1419 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === 1420 1420 1421 1421 ... ... @@ -1424,6 +1424,7 @@ 1424 1424 [[image:1653356991268-289.png]] 1425 1425 1426 1426 1415 + 1427 1427 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1428 1428 1429 1429 ... ... @@ -1545,6 +1545,7 @@ 1545 1545 ))) 1546 1546 1547 1547 1537 + 1548 1548 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1549 1549 1550 1550 ... ... @@ -1555,6 +1555,7 @@ 1555 1555 [[image:1653357531600-905.png]] 1556 1556 1557 1557 1548 + 1558 1558 === 3.6.4 Analog Input Interface === 1559 1559 1560 1560 ... ... @@ -1586,6 +1586,7 @@ 1586 1586 [[image:1653357648330-671.png||height="155" width="733"]] 1587 1587 1588 1588 1580 + 1589 1589 === 3.6.5 Relay Output === 1590 1590 1591 1591 ... ... @@ -1601,6 +1601,7 @@ 1601 1601 [[image:image-20220524100215-10.png||height="382" width="723"]] 1602 1602 1603 1603 1596 + 1604 1604 == 3.7 LEDs Indicators == 1605 1605 1606 1606 ... ... @@ -1610,6 +1610,7 @@ 1610 1610 1611 1611 = 4. Use AT Command = 1612 1612 1606 + 1613 1613 == 4.1 Access AT Command == 1614 1614 1615 1615 ... ... @@ -1820,8 +1820,10 @@ 1820 1820 ))) 1821 1821 1822 1822 1817 + 1823 1823 == 4.2 Common AT Command Sequence == 1824 1824 1820 + 1825 1825 === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1826 1826 1827 1827 ((( ... ... @@ -1866,6 +1866,7 @@ 1866 1866 ))) 1867 1867 1868 1868 1865 + 1869 1869 === 4.2.2 Single-channel ABP mode (Use with LG01/LG02) === 1870 1870 1871 1871 ((( ... ... @@ -1963,8 +1963,10 @@ 1963 1963 ))) 1964 1964 1965 1965 1963 + 1966 1966 = 5. FAQ = 1967 1967 1966 + 1968 1968 == 5.1 How to upgrade the image? == 1969 1969 1970 1970 ... ... @@ -2008,6 +2008,8 @@ 2008 2008 2009 2009 ((( 2010 2010 ((( 2010 + 2011 + 2011 2011 == 5.2 How to change the LoRa Frequency Bands/Region? == 2012 2012 2013 2013 ... ... @@ -2021,6 +2021,7 @@ 2021 2021 ((( 2022 2022 2023 2023 2025 + 2024 2024 == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 2025 2025 2026 2026 ... ... @@ -2084,6 +2084,7 @@ 2084 2084 [[image:1653360498588-932.png||height="485" width="726"]] 2085 2085 2086 2086 2089 + 2087 2087 == 5.4 Can I see counting event in Serial? == 2088 2088 2089 2089 ... ... @@ -2091,11 +2091,13 @@ 2091 2091 User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 2092 2092 2093 2093 2097 + 2094 2094 == 5.5 Can i use point to point communication for LT-22222-L? == 2095 2095 2096 2096 2097 -Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https:// github.com/dragino/LT-22222-L/releases]].2101 +Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AADKXQ2v5ZT-S3sxdmbvE7UAa/LT-22222-L/image?dl=0&subfolder_nav_tracking=1]]. 2098 2098 2103 + 2099 2099 2100 2100 ))) 2101 2101 ... ... @@ -2112,6 +2112,7 @@ 2112 2112 After restart, the status before power failure will be read from flash. 2113 2113 2114 2114 2120 + 2115 2115 == 5.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? == 2116 2116 2117 2117 ... ... @@ -2127,7 +2127,10 @@ 2127 2127 Firmware version needs to be no less than 1.6.0. 2128 2128 2129 2129 2136 + 2130 2130 = 6. Trouble Shooting = 2138 + 2139 + 2131 2131 ))) 2132 2132 2133 2133 ((( ... ... @@ -2145,6 +2145,7 @@ 2145 2145 ((( 2146 2146 2147 2147 2157 + 2148 2148 == 6.2 Have trouble to upload image. == 2149 2149 2150 2150 ... ... @@ -2157,6 +2157,7 @@ 2157 2157 ((( 2158 2158 2159 2159 2170 + 2160 2160 == 6.3 Why I can't join TTN in US915 /AU915 bands? == 2161 2161 2162 2162 ... ... @@ -2167,6 +2167,7 @@ 2167 2167 ))) 2168 2168 2169 2169 2181 + 2170 2170 = 7. Order Info = 2171 2171 2172 2172 ... ... @@ -2184,8 +2184,6 @@ 2184 2184 * (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 2185 2185 * (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 2186 2186 2187 - 2188 - 2189 2189 = 8. Packing Info = 2190 2190 2191 2191 ... ... @@ -2203,8 +2203,6 @@ 2203 2203 * Package Size / pcs : 14.5 x 8 x 5 cm 2204 2204 * Weight / pcs : 170g 2205 2205 2206 - 2207 - 2208 2208 = 9. Support = 2209 2209 2210 2210