Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
From version 108.1
edited by Edwin Chen
on 2022/11/19 09:29
on 2022/11/19 09:29
Change comment:
There is no comment for this version
To version 123.1
edited by Bei Jinggeng
on 2023/06/16 16:46
on 2023/06/16 16:46
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Bei - Content
-
... ... @@ -15,7 +15,6 @@ 15 15 16 16 = 1.Introduction = 17 17 18 - 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( ... ... @@ -27,7 +27,7 @@ 27 27 ))) 28 28 29 29 ((( 30 -The LT I/O Controllers allows the user to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection,building automation, and so on.29 +The LT I/O Controllers allows the user to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, building automation, and so on. 31 31 ))) 32 32 33 33 ((( ... ... @@ -54,7 +54,6 @@ 54 54 55 55 ))) 56 56 57 - 58 58 == 1.2 Specifications == 59 59 60 60 ((( ... ... @@ -171,7 +171,6 @@ 171 171 Packet engine up to 256 bytes with CRC. 172 172 173 173 174 - 175 175 176 176 ))) 177 177 ... ... @@ -179,29 +179,45 @@ 179 179 180 180 181 181 * LoRaWAN Class A & Class C protocol 179 + 182 182 * Optional Customized LoRa Protocol 181 + 183 183 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865/MA869 183 + 184 184 * AT Commands to change parameters 185 + 185 185 * Remote configure parameters via LoRa Downlink 187 + 186 186 * Firmware upgradable via program port 189 + 187 187 * Counting 188 188 192 + 189 189 == 1.4 Applications == 190 190 191 191 192 192 * Smart Buildings & Home Automation 197 + 193 193 * Logistics and Supply Chain Management 199 + 194 194 * Smart Metering 201 + 195 195 * Smart Agriculture 203 + 196 196 * Smart Cities 205 + 197 197 * Smart Factory 198 198 208 + 199 199 == 1.5 Hardware Variants == 200 200 201 201 202 -(% border="1" style="background-color:#f7faff; width:500px" %) 203 -|(% style="width:103px" %)**Model**|(% style="width:131px" %)**Photo**|(% style="width:334px" %)**Description** 204 -|(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)[[image:1653296302983-697.png]]|(% style="width:334px" %)((( 212 +(% border="1" style="background-color:#f2f2f2; width:500px" %) 213 +|(% style="background-color:#d9e2f3; color:#0070c0; width:103px" %)**Model**|(% style="background-color:#d9e2f3; color:#0070c0; width:131px" %)**Photo**|(% style="background-color:#d9e2f3; color:#0070c0; width:334px" %)**Description** 214 +|(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)((( 215 +(% style="text-align:center" %) 216 +[[image:image-20230424115112-1.png||height="106" width="58"]] 217 +)))|(% style="width:334px" %)((( 205 205 * 2 x Digital Input (Bi-direction) 206 206 * 2 x Digital Output 207 207 * 2 x Relay Output (5A@250VAC / 30VDC) ... ... @@ -210,6 +210,7 @@ 210 210 * 1 x Counting Port 211 211 ))) 212 212 226 + 213 213 = 2. Power ON Device = 214 214 215 215 ... ... @@ -226,10 +226,8 @@ 226 226 [[image:1653297104069-180.png]] 227 227 228 228 229 - 230 230 = 3. Operation Mode = 231 231 232 - 233 233 == 3.1 How it works? == 234 234 235 235 ... ... @@ -242,7 +242,6 @@ 242 242 ))) 243 243 244 244 245 - 246 246 == 3.2 Example to join LoRaWAN network == 247 247 248 248 ... ... @@ -269,7 +269,7 @@ 269 269 Each LT is shipped with a sticker with the default device EUI as below: 270 270 ))) 271 271 272 -[[image: 1653297924498-393.png]]283 +[[image:image-20230425173427-2.png||height="246" width="530"]] 273 273 274 274 275 275 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: ... ... @@ -294,7 +294,6 @@ 294 294 [[image:1653298044601-602.png||height="405" width="709"]] 295 295 296 296 297 - 298 298 == 3.3 Uplink Payload == 299 299 300 300 ... ... @@ -301,29 +301,47 @@ 301 301 There are five working modes + one interrupt mode on LT for different type application: 302 302 303 303 * (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO 314 + 304 304 * (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO 316 + 305 305 * (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO 318 + 306 306 * (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO 320 + 307 307 * (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 322 + 308 308 * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 309 309 325 + 310 310 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 311 311 312 312 313 313 ((( 314 -The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. 330 +The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. (% style="display:none" %) 331 + 332 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 333 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1** 334 +|Value|((( 335 +AVI1 voltage 336 +)))|((( 337 +AVI2 voltage 338 +)))|((( 339 +ACI1 Current 340 +)))|((( 341 +ACI2 Current 342 +)))|DIDORO*|((( 343 +Reserve 344 +)))|MOD 315 315 ))) 316 316 317 -[[image:image-20220523174024-3.png]] 318 - 319 319 ((( 320 - 321 - 322 322 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 349 + 350 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 351 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 352 +|RO1|RO2|DI3|DI2|DI1|DO3|DO2|DO1 323 323 ))) 324 324 325 -[[image:image-20220523174254-4.png]] 326 - 327 327 * RO is for relay. ROx=1 : close,ROx=0 always open. 328 328 * DI is for digital input. DIx=1: high or float, DIx=0: low. 329 329 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. ... ... @@ -363,6 +363,7 @@ 363 363 ** DO1 is high in case there is load between DO1 and V+. 364 364 ** DO1 LED is off in both case 365 365 394 + 366 366 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 367 367 368 368 ... ... @@ -372,18 +372,24 @@ 372 372 373 373 ((( 374 374 Total : 11 bytes payload 404 + 405 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 406 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1** 407 +|Value|COUNT1|COUNT2 |DIDORO*|((( 408 +Reserve 409 +)))|MOD 375 375 ))) 376 376 377 -[[image:image-20220523180452-3.png]] 378 - 379 - 380 380 ((( 381 381 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 382 -))) 383 383 384 -[[image:image-20220523180506-4.png]] 415 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 416 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 417 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 385 385 386 -* RO is for relay. ROx=1 : close,ROx=0 always open. 419 +RO is for relay. ROx=1 : close,ROx=0 always open. 420 +))) 421 + 387 387 * FIRST: Indicate this is the first packet after join network. 388 388 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 389 389 ... ... @@ -414,14 +414,11 @@ 414 414 415 415 416 416 (% style="color:#4f81bd" %)**AT Commands for counting:** 417 - 418 - 419 419 ))) 420 420 421 421 ((( 422 422 **For LT22222-L:** 423 423 424 - 425 425 (% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger on low level, valid signal is 100ms) ** 426 426 427 427 (% style="color:blue" %)**AT+TRIG1=1,100**(%%)** (set DI1 port to trigger on high level, valid signal is 100ms ) ** ... ... @@ -436,22 +436,27 @@ 436 436 ))) 437 437 438 438 439 - 440 440 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 441 441 442 442 443 443 **LT22222-L**: This mode the DI1 is used as a counting pin. 444 444 445 -[[image:image-20220523181246-5.png]] 476 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 477 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1** 478 +|Value|COUNT1|((( 479 +ACI1 Current 480 +)))|((( 481 +ACI2 Current 482 +)))|DIDORO*|Reserve|MOD 446 446 447 447 ((( 448 - 449 - 450 450 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 486 + 487 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 488 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 489 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 451 451 ))) 452 452 453 -[[image:image-20220523181301-6.png]] 454 - 455 455 * RO is for relay. ROx=1 : close,ROx=0 always open. 456 456 * FIRST: Indicate this is the first packet after join network. 457 457 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. ... ... @@ -483,7 +483,6 @@ 483 483 ))) 484 484 485 485 486 - 487 487 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 488 488 489 489 ... ... @@ -493,17 +493,22 @@ 493 493 494 494 ((( 495 495 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. 532 + 533 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 534 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1** 535 +|Value|COUNT1|AVI1 Counting|DIDORO*|((( 536 +Reserve 537 +)))|MOD 496 496 ))) 497 497 498 -[[image:image-20220523181903-8.png]] 499 - 500 - 501 501 ((( 502 502 (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 542 + 543 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 544 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 545 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 503 503 ))) 504 504 505 -[[image:image-20220523181727-7.png]] 506 - 507 507 * RO is for relay. ROx=1 : close,ROx=0 always open. 508 508 * FIRST: Indicate this is the first packet after join network. 509 509 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. ... ... @@ -537,11 +537,8 @@ 537 537 ))) 538 538 539 539 ((( 540 - 541 - 542 542 **Plus below command for AVI1 Counting:** 543 543 544 - 545 545 (% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 546 546 547 547 (% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** ... ... @@ -552,18 +552,29 @@ 552 552 ))) 553 553 554 554 555 - 556 556 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 557 557 558 558 559 559 **LT22222-L**: This mode the DI1 is used as a counting pin. 560 560 561 -[[image:image-20220523182334-9.png]] 598 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 599 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1** 600 +|Value|((( 601 +AVI1 voltage 602 +)))|((( 603 +AVI2 voltage 604 +)))|((( 605 +ACI1 Current 606 +)))|COUNT1|DIDORO*|((( 607 +Reserve 608 +)))|MOD 562 562 563 563 ((( 564 - 565 - 566 566 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 612 + 613 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 614 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 615 +|RO1|RO2|FIRST|Reserve|Reserve|DO3|DO2|DO1 567 567 ))) 568 568 569 569 * RO is for relay. ROx=1 : close,ROx=0 always open. ... ... @@ -600,7 +600,6 @@ 600 600 ))) 601 601 602 602 603 - 604 604 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 605 605 606 606 ... ... @@ -655,7 +655,6 @@ 655 655 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 656 656 657 657 658 - 659 659 (% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 660 660 661 661 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** ... ... @@ -690,12 +690,39 @@ 690 690 691 691 MOD6 Payload : total 11 bytes payload 692 692 693 -[[image:image-20220524085923-1.png]] 740 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 741 +|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:110px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**6**|(% style="background-color:#d9e2f3; color:#0070c0; width:110px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**1** 742 +|Value|((( 743 +TRI_A FLAG 744 +)))|((( 745 +TRI_A Status 746 +)))|((( 747 +TRI_DI FLAG+STA 748 +)))|Reserve|Enable/Disable MOD6|((( 749 +MOD(6) 750 +))) 694 694 695 - 696 696 (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below 697 697 698 -[[image:image-20220524090106-2.png]] 754 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 755 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 756 +|((( 757 +AV1_LOW 758 +)))|((( 759 +AV1_HIGH 760 +)))|((( 761 +AV2_LOW 762 +)))|((( 763 +AV2_HIGH 764 +)))|((( 765 +AC1_LOW 766 +)))|((( 767 +AC1_HIGH 768 +)))|((( 769 +AC2_LOW 770 +)))|((( 771 +AC2_HIGH 772 +))) 699 699 700 700 * Each bits shows if the corresponding trigger has been configured. 701 701 ... ... @@ -704,10 +704,27 @@ 704 704 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW 705 705 706 706 707 - 708 708 (% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1byte as below 709 709 710 -[[image:image-20220524090249-3.png]] 783 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 784 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 785 +|((( 786 +AV1_LOW 787 +)))|((( 788 +AV1_HIGH 789 +)))|((( 790 +AV2_LOW 791 +)))|((( 792 +AV2_HIGH 793 +)))|((( 794 +AC1_LOW 795 +)))|((( 796 +AC1_HIGH 797 +)))|((( 798 +AC2_LOW 799 +)))|((( 800 +AC2_HIGH 801 +))) 711 711 712 712 * Each bits shows which status has been trigger on this uplink. 713 713 ... ... @@ -716,10 +716,11 @@ 716 716 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. 717 717 718 718 719 - 720 720 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 721 721 722 -[[image:image-20220524090456-4.png]] 812 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 813 +|**bit7**|**bit6**|**bit5**|**bit4**|**bit3**|**bit2**|**bit1**|**bit0** 814 +|N/A|N/A|N/A|N/A|DI2_STATUS|DI2_FLAG|DI1_STATUS|DI1_FLAG 723 723 724 724 * Each bits shows which status has been trigger on this uplink. 725 725 ... ... @@ -730,7 +730,6 @@ 730 730 00000101: Means both DI1 and DI2 trigger are enabled. 731 731 732 732 733 - 734 734 (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable. 735 735 736 736 Downlink command to poll MOD6 status: ... ... @@ -740,7 +740,6 @@ 740 740 When device got this command, it will send the MOD6 payload. 741 741 742 742 743 - 744 744 === 3.3.7 Payload Decoder === 745 745 746 746 ((( ... ... @@ -750,7 +750,6 @@ 750 750 ))) 751 751 752 752 753 - 754 754 == 3.4 Configure LT via AT or Downlink == 755 755 756 756 ... ... @@ -768,6 +768,7 @@ 768 768 769 769 * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 770 770 860 + 771 771 === 3.4.1 Common Commands === 772 772 773 773 ... ... @@ -776,10 +776,8 @@ 776 776 ))) 777 777 778 778 779 - 780 780 === 3.4.2 Sensor related commands === 781 781 782 - 783 783 ==== 3.4.2.1 Set Transmit Interval ==== 784 784 785 785 ... ... @@ -804,14 +804,10 @@ 804 804 805 805 Set work mode. 806 806 807 -* (% style="color:#037691" %)**AT Command:** 895 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+MOD=N ** 808 808 809 -(% style="color:blue" %)**AT+MOD=N ** 810 - 811 - 812 812 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 813 813 814 - 815 815 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 816 816 817 817 (% style="color:blue" %)**0x0A aa **(%%)** ** ~/~/ Same as AT+MOD=aa ... ... @@ -821,16 +821,12 @@ 821 821 ==== 3.4.2.3 Poll an uplink ==== 822 822 823 823 824 -* (% style="color:#037691" %)**AT Command:** 908 +* (% style="color:#037691" %)**AT Command:**(%%) There is no AT Command to poll uplink 825 825 826 -There is no AT Command to poll uplink 827 - 828 - 829 829 * (% style="color:#037691" %)**Downlink Payload (prefix 0x08):** 830 830 831 831 (% style="color:blue" %)**0x08 FF **(%%)** **~/~/ Poll an uplink 832 832 833 - 834 834 **Example**: 0x08FF, ask device to send an Uplink 835 835 836 836 ... ... @@ -840,10 +840,8 @@ 840 840 841 841 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 842 842 843 -* (% style="color:#037691" %)**AT Command:** 923 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+ADDMOD6=1 or 0** 844 844 845 -(% style="color:blue" %)**AT+ADDMOD6=1 or 0** 846 - 847 847 (% style="color:red" %)**1:** (%%)Enable Trigger Mode 848 848 849 849 (% style="color:red" %)**0: **(%%)Disable Trigger Mode ... ... @@ -855,17 +855,15 @@ 855 855 856 856 857 857 858 - 859 859 ==== 3.4.2.5 Poll trigger settings ==== 860 860 861 861 862 -Poll trigger settings ,939 +Poll trigger settings 863 863 864 864 * (% style="color:#037691" %)**AT Command:** 865 865 866 866 There is no AT Command for this feature. 867 867 868 - 869 869 * (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 870 870 871 871 (% style="color:blue" %)**0xAB 06 ** (%%) ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command ... ... @@ -877,15 +877,11 @@ 877 877 878 878 Enable Disable DI1/DI2/DI2 as trigger, 879 879 880 -* (% style="color:#037691" %)**AT Command:** 956 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 881 881 882 - (% style="color:blue" %)**Format:AT+DTRI=<DI1_TIRGGER_FlAG>,<DI2_TIRGGER_FlAG>**958 +**Example:** AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 883 883 884 884 885 -**Example:** 886 - 887 -AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 888 - 889 889 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 890 890 891 891 (% style="color:blue" %)**0xAA 02 aa bb ** (%%) ~/~/ Same as AT+DTRI=aa,bb ... ... @@ -897,20 +897,15 @@ 897 897 898 898 Set DI1 or DI3(for LT-33222-L) trigger. 899 899 900 -* (% style="color:#037691" %)**AT Command:** 972 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+TRIG1=a,b** 901 901 902 -(% style="color:blue" %)**AT+TRIG1=a,b** 903 - 904 904 (% style="color:red" %)**a :** (%%)Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 905 905 906 906 (% style="color:red" %)**b :** (%%)delay timing. 907 907 978 +**Example:** AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 908 908 909 -**Example:** 910 910 911 -AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 912 - 913 - 914 914 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 915 915 916 916 (% style="color:blue" %)**0x09 01 aa bb cc ** (%%) ~/~/ same as AT+TRIG1=aa,0x(bb cc) ... ... @@ -922,23 +922,18 @@ 922 922 923 923 Set DI2 trigger. 924 924 925 -* (% style="color:#037691" %)**AT Command:** 992 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+TRIG2=a,b** 926 926 927 -(% style="color:blue" %)**AT+TRIG2=a,b** 928 - 929 929 (% style="color:red" %)**a :** (%%)Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 930 930 931 931 (% style="color:red" %)**b :** (%%)delay timing. 932 932 998 +**Example:** AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 933 933 934 -**Example:** 935 935 936 -AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 937 - 938 - 939 939 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 940 940 941 -(% style="color:blue" %)**0x09 02 aa bb cc ** (%%)~/~/ same as AT+TRIG 1=aa,0x(bb cc)1003 +(% style="color:blue" %)**0x09 02 aa bb cc ** (%%)~/~/ same as AT+TRIG2=aa,0x(bb cc) 942 942 943 943 944 944 ... ... @@ -947,11 +947,8 @@ 947 947 948 948 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 949 949 950 -* (% style="color:#037691" %)**AT Command** 1012 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+ACLIM** 951 951 952 -(% style="color:blue" %)**AT+ACLIM** 953 - 954 - 955 955 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )** 956 956 957 957 (% style="color:blue" %)**0x AA 01 aa bb cc dd ee ff gg hh ** (%%) ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -963,11 +963,8 @@ 963 963 964 964 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 965 965 966 -* (% style="color:#037691" %)**AT Command** 1025 +* (% style="color:#037691" %)**AT Command**(%%): (% style="color:blue" %)**AT+AVLIM **(%%)** See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 967 967 968 -(% style="color:blue" %)**AT+AVLIM **(%%)** See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 969 - 970 - 971 971 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )** 972 972 973 973 (% style="color:blue" %)**0x AA 00 aa bb cc dd ee ff gg hh ** (%%) ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -979,18 +979,13 @@ 979 979 980 980 Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 981 981 982 -* (% style="color:#037691" %)**AT Command** 1038 +* (% style="color:#037691" %)**AT Command**(%%): (% style="color:blue" %)**AT+ATDC=5 ** ~/~/ (%%)Device won't response the second trigger within 5 minute after the first trigger. 983 983 984 -(% style="color:blue" %)**AT+ATDC=5 ** (%%)Device won't response the second trigger within 5 minute after the first trigger. 985 - 986 - 987 987 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** 988 988 989 989 (% style="color:blue" %)**0x AC aa bb **(%%) ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 990 990 991 991 ((( 992 - 993 - 994 994 (% style="color:red" %)**Note: ATDC setting must be more than 5min** 995 995 ))) 996 996 ... ... @@ -1005,8 +1005,9 @@ 1005 1005 1006 1006 1007 1007 * (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 1008 -* (% style="color:blue" %)**0x02 aa bb cc ** (%%)~/~/ Set DO1/DO2/DO3 output 1009 1009 1060 +(% style="color:blue" %)**0x02 aa bb cc ** (%%)~/~/ Set DO1/DO2/DO3 output 1061 + 1010 1010 ((( 1011 1011 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 1012 1012 ))) ... ... @@ -1013,10 +1013,14 @@ 1013 1013 1014 1014 ((( 1015 1015 01: Low, 00: High , 11: No action 1068 + 1069 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 1070 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Downlink Code**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**DO3** 1071 +|02 01 00 11|Low|High|No Action 1072 +|02 00 11 01|High|No Action|Low 1073 +|02 11 01 00|No Action|Low|High 1016 1016 ))) 1017 1017 1018 -[[image:image-20220524092754-5.png]] 1019 - 1020 1020 ((( 1021 1021 (% style="color:red" %)**Note: For LT-22222-L, there is no DO3, the last byte can use any value.** 1022 1022 ))) ... ... @@ -1053,23 +1053,37 @@ 1053 1053 1054 1054 (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status: 1055 1055 1056 -[[image:image-20220524093238-6.png]] 1112 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1113 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status** 1114 +|0x01|DO1 set to low 1115 +|0x00|DO1 set to high 1116 +|0x11|DO1 NO Action 1057 1057 1058 - 1059 1059 (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status: 1060 1060 1061 -[[image:image-20220524093328-7.png]] 1120 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1121 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status** 1122 +|0x01|DO2 set to low 1123 +|0x00|DO2 set to high 1124 +|0x11|DO2 NO Action 1062 1062 1063 - 1064 1064 (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status: 1065 1065 1066 -[[image:image-20220524093351-8.png]] 1128 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:300px" %) 1129 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Second Byte**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Status** 1130 +|0x01|DO3 set to low 1131 +|0x00|DO3 set to high 1132 +|0x11|DO3 NO Action 1067 1067 1134 +(% style="color:#4f81bd" %)**Sixth and Seventh and Eighth and Ninth Byte**:(%%) Latching time. Unit: ms 1068 1068 1069 -(% style="color:#4f81bd" %)**Sixth and Seventh and Eighth and Ninth Byte**: 1070 1070 1071 - Latching time.Unit:ms1137 +(% style="color:red" %)**Note: ** 1072 1072 1139 + Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1140 + 1141 + Before Firmwre v1.6.0 the latch time only suport 2 bytes. 1142 + 1073 1073 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1074 1074 1075 1075 ... ... @@ -1093,7 +1093,7 @@ 1093 1093 1094 1094 1095 1095 1096 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1166 +==== 3.4.2. 14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1097 1097 1098 1098 1099 1099 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1112,10 +1112,17 @@ 1112 1112 1113 1113 ((( 1114 1114 01: Close , 00: Open , 11: No action 1115 -))) 1116 1116 1117 -((( 1118 -[[image:image-20220524093724-9.png]] 1186 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:320px" %) 1187 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Downlink Code**|(% style="background-color:#d9e2f3; color:#0070c0" %)**RO1**|(% style="background-color:#d9e2f3; color:#0070c0" %)**RO2** 1188 +|03 00 11|Open|No Action 1189 +|03 01 11|Close|No Action 1190 +|03 11 00|No Action|Open 1191 +|03 11 01|No Action|Close 1192 +|03 00 00|Open|Open 1193 +|03 01 01|Close|Close 1194 +|03 01 00|Close|Open 1195 +|03 00 01|Open|Close 1119 1119 ))) 1120 1120 1121 1121 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** ... ... @@ -1122,7 +1122,6 @@ 1122 1122 1123 1123 1124 1124 1125 - 1126 1126 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1127 1127 1128 1128 ... ... @@ -1154,12 +1154,20 @@ 1154 1154 1155 1155 (% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms 1156 1156 1233 + 1234 +(% style="color:red" %)**Note:** 1235 + 1236 + Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1237 + 1238 + Before Firmwre v1.6.0 the latch time only suport 2 bytes. 1239 + 1240 + 1157 1157 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1158 1158 1159 1159 1160 1160 **Example payload:** 1161 1161 1162 -**~1. 05 01 11 07 D** 1246 +**~1. 05 01 11 07 D0** 1163 1163 1164 1164 Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state. 1165 1165 ... ... @@ -1182,11 +1182,8 @@ 1182 1182 1183 1183 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1184 1184 1185 -* (% style="color:#037691" %)**AT Command:** 1269 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+VOLMAX ** (%%)~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1186 1186 1187 -(% style="color:blue" %)**AT+VOLMAX ** (%%)~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1188 - 1189 - 1190 1190 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1191 1191 1192 1192 (% style="color:blue" %)**0xA5 aa bb cc ** (%%)~/~/ Same as AT+VOLMAX=(aa bb),cc ... ... @@ -1196,10 +1196,8 @@ 1196 1196 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1197 1197 1198 1198 1199 -* (% style="color:#037691" %)**AT Command:** 1280 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+SETCNT=aa,(bb cc dd ee) ** 1200 1200 1201 -(% style="color:blue" %)**AT+SETCNT=aa,(bb cc dd ee) ** 1202 - 1203 1203 (% style="color:red" %)**aa:**(%%) 1: Set count1; 2: Set count2; 3: Set AV1 count 1204 1204 1205 1205 (% style="color:red" %)**bb cc dd ee: **(%%)number to be set ... ... @@ -1216,11 +1216,8 @@ 1216 1216 1217 1217 Clear counting for counting mode 1218 1218 1219 -* (% style="color:#037691" %)**AT Command:** 1298 +* (% style="color:#037691" %)**AT Command:**(%%) (% style="color:blue" %)**AT+CLRCOUNT **(%%) ~/~/ clear all counting 1220 1220 1221 -(% style="color:blue" %)**AT+CLRCOUNT **(%%) ~/~/ clear all counting 1222 - 1223 - 1224 1224 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1225 1225 1226 1226 (% style="color:blue" %)**0x A6 01 ** (%%)~/~/ clear all counting ... ... @@ -1294,7 +1294,6 @@ 1294 1294 1295 1295 1296 1296 1297 - 1298 1298 ==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ==== 1299 1299 1300 1300 ... ... @@ -1311,7 +1311,6 @@ 1311 1311 1312 1312 1313 1313 1314 - 1315 1315 ==== 3.4.2.25 Copy downlink to uplink ==== 1316 1316 1317 1317 ... ... @@ -1350,7 +1350,6 @@ 1350 1350 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]] 1351 1351 1352 1352 1353 - 1354 1354 == 3.5 Integrate with Mydevice == 1355 1355 1356 1356 ... ... @@ -1375,7 +1375,7 @@ 1375 1375 1376 1376 (% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices. 1377 1377 1378 -(% style="color:blue" %)**Step 4**(%%): Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)1451 +(% style="color:blue" %)**Step 4**(%%): Search LT-22222-L(for both LT-22222-L) and add DevEUI.(% style="display:none" %) 1379 1379 1380 1380 Search under The things network 1381 1381 ... ... @@ -1400,10 +1400,8 @@ 1400 1400 [[image:image-20220524094909-5.png||height="341" width="734"]] 1401 1401 1402 1402 1403 - 1404 1404 == 3.6 Interface Detail == 1405 1405 1406 - 1407 1407 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === 1408 1408 1409 1409 ... ... @@ -1412,7 +1412,6 @@ 1412 1412 [[image:1653356991268-289.png]] 1413 1413 1414 1414 1415 - 1416 1416 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1417 1417 1418 1418 ... ... @@ -1469,8 +1469,6 @@ 1469 1469 1470 1470 ((( 1471 1471 1472 - 1473 - 1474 1474 ))) 1475 1475 1476 1476 ((( ... ... @@ -1502,8 +1502,6 @@ 1502 1502 1503 1503 ((( 1504 1504 1505 - 1506 - 1507 1507 ))) 1508 1508 1509 1509 ((( ... ... @@ -1534,18 +1534,16 @@ 1534 1534 ))) 1535 1535 1536 1536 1537 - 1538 1538 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1539 1539 1540 1540 1541 -**NPN output**: GND or Float. Max voltage can apply to output pin is 36v. 1606 +(% style="color:blue" %)**NPN output**(%%): GND or Float. Max voltage can apply to output pin is 36v. 1542 1542 1543 -Note: DO pins go to float when device is power off. 1608 +(% style="color:red" %)**Note: DO pins go to float when device is power off.** 1544 1544 1545 1545 [[image:1653357531600-905.png]] 1546 1546 1547 1547 1548 - 1549 1549 === 3.6.4 Analog Input Interface === 1550 1550 1551 1551 ... ... @@ -1563,13 +1563,12 @@ 1563 1563 1564 1564 (% style="color:blue" %)**Specifications of the wind speed sensor:** 1565 1565 1566 -**Red: 12~~24v** 1630 +(% style="color:red" %)**Red: 12~~24v** 1567 1567 1568 -**Yellow: 4~~20mA** 1632 +(% style="color:#ffc000" %)**Yellow: 4~~20mA** 1569 1569 1570 1570 **Black: GND** 1571 1571 1572 - 1573 1573 **Connection diagram:** 1574 1574 1575 1575 [[image:1653357640609-758.png]] ... ... @@ -1577,7 +1577,22 @@ 1577 1577 [[image:1653357648330-671.png||height="155" width="733"]] 1578 1578 1579 1579 1643 +Example connected to a regulated power supply to measure voltage 1580 1580 1645 +[[image:image-20230608101532-1.png||height="606" width="447"]] 1646 + 1647 +[[image:image-20230608101608-2.jpeg||height="379" width="284"]] 1648 + 1649 +[[image:image-20230608101722-3.png||height="102" width="1139"]] 1650 + 1651 + 1652 +(% style="color:blue; font-weight:bold" %)**Specifications of the regulated power**(%%) (% style="color:blue" %)**:** 1653 + 1654 +(% style="color:red" %)**Red: 12~~24v** 1655 + 1656 +**Black: GND** 1657 + 1658 + 1581 1581 === 3.6.5 Relay Output === 1582 1582 1583 1583 ... ... @@ -1593,17 +1593,47 @@ 1593 1593 [[image:image-20220524100215-10.png||height="382" width="723"]] 1594 1594 1595 1595 1596 - 1597 1597 == 3.7 LEDs Indicators == 1598 1598 1599 1599 1600 -[[image:image-20220524100748-11.png]] 1677 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:520px" %) 1678 +|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**LEDs**|(% style="background-color:#d9e2f3; color:#0070c0; width:470px" %)**Feature** 1679 +|**PWR**|Always on if there is power 1680 +|**SYS**|((( 1681 +After device is powered on, the SYS will **fast blink in GREEN** for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be **on GREEN for 5 seconds. **SYS will **blink Blue** on every upload and **blink Green** once receive a downlink message. 1682 +))) 1683 +|**TX**|((( 1684 +((( 1685 +Device boot: TX blinks 5 times. 1686 +))) 1601 1601 1688 +((( 1689 +Successful join network: TX ON for 5 seconds. 1690 +))) 1602 1602 1692 +((( 1693 +Transmit a LoRa packet: TX blinks once 1694 +))) 1695 +))) 1696 +|**RX**|RX blinks once when receive a packet. 1697 +|**DO1**| 1698 +|**DO2**| 1699 +|**DO3**| 1700 +|**DI2**|((( 1701 +For LT-22222-L: ON when DI2 is high, LOW when DI2 is low 1702 +))) 1703 +|**DI2**|((( 1704 +For LT-22222-L: ON when DI2 is high, LOW when DI2 is low 1705 +))) 1706 +|**DI2**|((( 1707 +For LT-22222-L: ON when DI2 is high, LOW when DI2 is low 1708 +))) 1709 +|**RO1**| 1710 +|**RO2**| 1603 1603 1712 + 1604 1604 = 4. Use AT Command = 1605 1605 1606 - 1607 1607 == 4.1 Access AT Command == 1608 1608 1609 1609 ... ... @@ -1814,10 +1814,8 @@ 1814 1814 ))) 1815 1815 1816 1816 1817 - 1818 1818 == 4.2 Common AT Command Sequence == 1819 1819 1820 - 1821 1821 === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1822 1822 1823 1823 ((( ... ... @@ -1862,7 +1862,6 @@ 1862 1862 ))) 1863 1863 1864 1864 1865 - 1866 1866 === 4.2.2 Single-channel ABP mode (Use with LG01/LG02) === 1867 1867 1868 1868 ((( ... ... @@ -1935,7 +1935,7 @@ 1935 1935 **3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php? 1936 1936 dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.** 1937 1937 1938 -**4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5** 2043 +**4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5.** 1939 1939 1940 1940 1941 1941 ))) ... ... @@ -1948,7 +1948,6 @@ 1948 1948 1949 1949 ))) 1950 1950 1951 - 1952 1952 === 4.2.3 Change to Class A === 1953 1953 1954 1954 ... ... @@ -1960,13 +1960,19 @@ 1960 1960 ))) 1961 1961 1962 1962 2067 += 5. Case Study = 1963 1963 1964 -= 5. F AQ=2069 +== 5.1 Counting how many objects pass in Flow Line == 1965 1965 1966 1966 1967 - ==5.1How to upgrade theimage?==2072 +Reference Link: [[How to set up to count objects pass in flow line>>How to set up to count objects pass in flow line]]? 1968 1968 1969 1969 2075 += 6. FAQ = 2076 + 2077 +== 6.1 How to upgrade the image? == 2078 + 2079 + 1970 1970 The LT LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to LT to: 1971 1971 1972 1972 * Support new features ... ... @@ -1980,7 +1980,7 @@ 1980 1980 1981 1981 ((( 1982 1982 (% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1983 -(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>> url:https://www.dropbox.com/sh/g99v0fxcltn9r1y/AADKXQ2v5ZT-S3sxdmbvE7UAa/LT-22222-L/image?dl=0&subfolder_nav_tracking=1]].2093 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AACrbrDN0AqLHbBat0ViWx5Da/LT-22222-L/Firmware?dl=0&subfolder_nav_tracking=1]]. 1984 1984 (% style="color:blue" %)**Step3**(%%)**:** Open flashloader; choose the correct COM port to update. 1985 1985 1986 1986 ... ... @@ -1994,8 +1994,10 @@ 1994 1994 1995 1995 [[image:image-20220524103407-12.png]] 1996 1996 2107 + 1997 1997 [[image:image-20220524103429-13.png]] 1998 1998 2110 + 1999 1999 [[image:image-20220524104033-15.png]] 2000 2000 2001 2001 ... ... @@ -2007,10 +2007,8 @@ 2007 2007 2008 2008 ((( 2009 2009 ((( 2010 - 2122 +== 6.2 How to change the LoRa Frequency Bands/Region? == 2011 2011 2012 -== 5.2 How to change the LoRa Frequency Bands/Region? == 2013 - 2014 2014 2015 2015 ))) 2016 2016 ))) ... ... @@ -2022,9 +2022,8 @@ 2022 2022 ((( 2023 2023 2024 2024 2135 +== 6.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 2025 2025 2026 -== 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 2027 - 2028 2028 2029 2029 ))) 2030 2030 ... ... @@ -2086,26 +2086,29 @@ 2086 2086 [[image:1653360498588-932.png||height="485" width="726"]] 2087 2087 2088 2088 2198 +== 6.4 How to change the uplink interval? == 2089 2089 2090 -== 5.4 Can I see counting event in Serial? == 2091 2091 2201 +Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/]] 2092 2092 2203 + 2204 +== 6.5 Can I see counting event in Serial? == 2205 + 2206 + 2093 2093 ((( 2094 2094 User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 2095 2095 2096 2096 2211 +== 6.6 Can i use point to point communication for LT-22222-L? == 2097 2097 2098 -== 5.5 Can i use point to point communication for LT-22222-L? == 2099 2099 2100 - 2101 2101 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https://github.com/dragino/LT-22222-L/releases]]. 2102 2102 2103 - 2104 2104 2105 2105 ))) 2106 2106 2107 2107 ((( 2108 -== 5.62220 +== 6.7 Why does the relay output become the default and open relay after the lt22222 is powered off? == 2109 2109 2110 2110 2111 2111 If the device is not shut down, but directly powered off. ... ... @@ -2117,10 +2117,9 @@ 2117 2117 After restart, the status before power failure will be read from flash. 2118 2118 2119 2119 2232 +== 6.8 Can i set up LT-22222-L as a NC(Normal Close) Relay? == 2120 2120 2121 -== 5.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? == 2122 2122 2123 - 2124 2124 LT-22222-L built-in relay is NO (Normal Open). User can use an external relay to achieve Normal Close purpose. Diagram as below: 2125 2125 2126 2126 ... ... @@ -2127,21 +2127,18 @@ 2127 2127 [[image:image-20221006170630-1.png||height="610" width="945"]] 2128 2128 2129 2129 2130 -== 5.8Can LT22222-L save RO state? ==2241 +== 6.9 Can LT22222-L save RO state? == 2131 2131 2132 2132 2133 2133 Firmware version needs to be no less than 1.6.0. 2134 2134 2135 2135 2136 - 2137 -= 6. Trouble Shooting = 2138 - 2139 - 2247 += 7. Trouble Shooting = 2140 2140 ))) 2141 2141 2142 2142 ((( 2143 2143 ((( 2144 -== 6.1 Downlink doesn't work, how to solve it? ==2252 +== 7.1 Downlink doesn't work, how to solve it? == 2145 2145 2146 2146 2147 2147 ))) ... ... @@ -2154,9 +2154,8 @@ 2154 2154 ((( 2155 2155 2156 2156 2265 +== 7.2 Have trouble to upload image. == 2157 2157 2158 -== 6.2 Have trouble to upload image. == 2159 - 2160 2160 2161 2161 ))) 2162 2162 ... ... @@ -2167,9 +2167,8 @@ 2167 2167 ((( 2168 2168 2169 2169 2277 +== 7.3 Why I can't join TTN in US915 /AU915 bands? == 2170 2170 2171 -== 6.3 Why I can't join TTN in US915 /AU915 bands? == 2172 - 2173 2173 2174 2174 ))) 2175 2175 ... ... @@ -2178,10 +2178,9 @@ 2178 2178 ))) 2179 2179 2180 2180 2287 += 8. Order Info = 2181 2181 2182 -= 7. Order Info = 2183 2183 2184 - 2185 2185 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 2186 2186 2187 2187 (% style="color:#4f81bd" %)**XXX:** ... ... @@ -2196,9 +2196,10 @@ 2196 2196 * (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 2197 2197 * (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 2198 2198 2199 -= 8. Packing Info = 2200 2200 2305 += 9. Packing Info = 2201 2201 2307 + 2202 2202 **Package Includes**: 2203 2203 2204 2204 * LT-22222-L I/O Controller x 1 ... ... @@ -2213,22 +2213,25 @@ 2213 2213 * Package Size / pcs : 14.5 x 8 x 5 cm 2214 2214 * Weight / pcs : 170g 2215 2215 2216 -= 9. Support = 2217 2217 2323 += 10. Support = 2218 2218 2325 + 2219 2219 * ((( 2220 2220 Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 2221 2221 ))) 2222 2222 * ((( 2223 -Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]2330 +Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]] 2224 2224 2225 2225 2226 2226 2227 2227 ))) 2228 2228 2229 -= 1 0. Reference =2336 += 11. Reference = 2230 2230 2231 2231 2232 2232 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2233 2233 * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 2234 2234 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 2342 + 2343 +
- image-20230424115112-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.1 KB - Content
- image-20230425173351-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +207.8 KB - Content
- image-20230425173427-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +150.1 KB - Content
- image-20230426161322-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.2 KB - Content
- image-20230608101532-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +563.0 KB - Content
- image-20230608101608-2.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +287.8 KB - Content
- image-20230608101722-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.4 KB - Content