Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -64,7 +64,7 @@ 64 64 ))) 65 65 66 66 * ((( 67 -STM32L072 xxxxMCU67 +STM32L072CZT6 MCU 68 68 ))) 69 69 * ((( 70 70 SX1276/78 Wireless Chip ... ... @@ -741,6 +741,7 @@ 741 741 742 742 743 743 744 + 744 744 === 3.3.7 Payload Decoder === 745 745 746 746 ((( ... ... @@ -764,9 +764,9 @@ 764 764 ))) 765 765 ))) 766 766 767 -* (% style="color:b lue" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]768 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 768 768 769 -* (% style="color:b lue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below:770 +* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 770 770 771 771 === 3.4.1 Common Commands === 772 772 ... ... @@ -787,7 +787,7 @@ 787 787 788 788 * (% style="color:#037691" %)**AT Command:** 789 789 790 - (% style="color:blue" %)**AT+TDC=N **791 +**AT+TDC=N ** 791 791 792 792 793 793 **Example: **AT+TDC=30000. Means set interval to 30 seconds ... ... @@ -795,10 +795,11 @@ 795 795 796 796 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 797 797 798 - (% style="color:blue" %)**0x01 aa bb cc**(%%)**~/~/ Same as AT+TDC=0x(aa bb cc)**799 +**0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 799 799 800 800 801 801 803 + 802 802 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 803 803 804 804 ... ... @@ -806,7 +806,7 @@ 806 806 807 807 * (% style="color:#037691" %)**AT Command:** 808 808 809 - (% style="color:blue" %)**AT+MOD=N **811 +**AT+MOD=N ** 810 810 811 811 812 812 **Example**: AT+MOD=2. Set work mode to Double DI counting mode ... ... @@ -814,10 +814,11 @@ 814 814 815 815 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 816 816 817 - (% style="color:blue" %)**0x0A aa **(%%)****~/~/ Same as AT+MOD=aa819 +**0x0A aa ** ~/~/ Same as AT+MOD=aa 818 818 819 819 820 820 823 + 821 821 ==== 3.4.2.3 Poll an uplink ==== 822 822 823 823 ... ... @@ -828,7 +828,7 @@ 828 828 829 829 * (% style="color:#037691" %)**Downlink Payload (prefix 0x08):** 830 830 831 - (% style="color:blue" %)**0x08 FF **(%%)** **~/~/ Poll an uplink834 +**0x08 FF **~/~/ Poll an uplink 832 832 833 833 834 834 **Example**: 0x08FF, ask device to send an Uplink ... ... @@ -835,6 +835,7 @@ 835 835 836 836 837 837 841 + 838 838 ==== 3.4.2.4 Enable Trigger Mode ==== 839 839 840 840 ... ... @@ -842,16 +842,16 @@ 842 842 843 843 * (% style="color:#037691" %)**AT Command:** 844 844 845 - (% style="color:blue" %)**AT+ADDMOD6=1 or 0**849 +**AT+ADDMOD6=1 or 0** 846 846 847 - (% style="color:red" %)**1:**(%%)Enable Trigger Mode851 +1: Enable Trigger Mode 848 848 849 - (% style="color:red" %)**0:**(%%)Disable Trigger Mode853 +0: Disable Trigger Mode 850 850 851 851 852 852 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):** 853 853 854 - (% style="color:blue" %)**0x0A 06 aa **(%%)858 +**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 855 855 856 856 857 857 ... ... @@ -868,10 +868,11 @@ 868 868 869 869 * (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 870 870 871 - (% style="color:blue" %)**0xAB 06 **(%%)~/~/ Poll trigger settings, device will uplink trigger settings once receive this command875 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 872 872 873 873 874 874 879 + 875 875 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 876 876 877 877 ... ... @@ -879,7 +879,7 @@ 879 879 880 880 * (% style="color:#037691" %)**AT Command:** 881 881 882 - (% style="color:blue" %)**Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**887 +**Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 883 883 884 884 885 885 **Example:** ... ... @@ -888,10 +888,11 @@ 888 888 889 889 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 890 890 891 - (% style="color:blue" %)**0xAA 02 aa bb **(%%)~/~/ Same as AT+DTRI=aa,bb896 +**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 892 892 893 893 894 894 900 + 895 895 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 896 896 897 897 ... ... @@ -899,11 +899,11 @@ 899 899 900 900 * (% style="color:#037691" %)**AT Command:** 901 901 902 - (% style="color:blue" %)**AT+TRIG1=a,b**908 +**AT+TRIG1=a,b** 903 903 904 - (% style="color:red" %)**a :**(%%)Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).910 +a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 905 905 906 - (% style="color:red" %)**b :**(%%)delay timing.912 +b : delay timing. 907 907 908 908 909 909 **Example:** ... ... @@ -912,11 +912,8 @@ 912 912 913 913 914 914 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 921 +* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 915 915 916 -(% style="color:blue" %)**0x09 01 aa bb cc ** (%%) ~/~/ same as AT+TRIG1=aa,0x(bb cc) 917 - 918 - 919 - 920 920 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 921 921 922 922 ... ... @@ -924,13 +924,14 @@ 924 924 925 925 * (% style="color:#037691" %)**AT Command:** 926 926 927 - (% style="color:blue" %)**AT+TRIG2=a,b**930 +**AT+TRIG2=a,b** 928 928 929 -(% style="color:red" %)**a :** (%%)Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 930 930 931 - (%style="color:red"%)**b:**(%%)delaytiming.933 +a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 932 932 935 +b : delay timing. 933 933 937 + 934 934 **Example:** 935 935 936 936 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) ... ... @@ -938,10 +938,11 @@ 938 938 939 939 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 940 940 941 - (% style="color:blue" %)**0x09 02 aa bb cc **(%%)~/~/ same as AT+TRIG1=aa,0x(bb cc)945 +**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 942 942 943 943 944 944 949 + 945 945 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 946 946 947 947 ... ... @@ -949,15 +949,16 @@ 949 949 950 950 * (% style="color:#037691" %)**AT Command** 951 951 952 - (% style="color:blue" %)**AT+ACLIM**957 +**AT+ACLIM** 953 953 954 954 955 955 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )** 956 956 957 - (% style="color:blue" %)**0x AA 01 aa bb cc dd ee ff gg hh **(%%)~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]962 +**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 958 958 959 959 960 960 966 + 961 961 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 962 962 963 963 ... ... @@ -965,15 +965,16 @@ 965 965 966 966 * (% style="color:#037691" %)**AT Command** 967 967 968 - (% style="color:blue" %)**AT+AVLIM**(%%)**See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**974 +**AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 969 969 970 970 971 971 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )** 972 972 973 - (% style="color:blue" %)**0x AA 00 aa bb cc dd ee ff gg hh **(%%)~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]979 +**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 974 974 975 975 976 976 983 + 977 977 ==== 3.4.2.11 Trigger – Set minimum interval ==== 978 978 979 979 ... ... @@ -981,12 +981,12 @@ 981 981 982 982 * (% style="color:#037691" %)**AT Command** 983 983 984 - (% style="color:blue" %)**AT+ATDC=5 **(%%)Device won't response the second trigger within 5 minute after the first trigger.991 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 985 985 986 986 987 987 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** 988 988 989 - (% style="color:blue" %)**0x AC aa bb **(%%)~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)996 +**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 990 990 991 991 ((( 992 992 ... ... @@ -996,6 +996,7 @@ 996 996 997 997 998 998 1006 + 999 999 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1000 1000 1001 1001 ... ... @@ -1005,7 +1005,7 @@ 1005 1005 1006 1006 1007 1007 * (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 1008 -* (% style="color:blue" %)**0x02 aa bb cc **(%%)~/~/ Set DO1/DO2/DO3 output1016 +* **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 1009 1009 1010 1010 ((( 1011 1011 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. ... ... @@ -1027,6 +1027,7 @@ 1027 1027 1028 1028 1029 1029 1038 + 1030 1030 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1031 1031 1032 1032 ... ... @@ -1037,7 +1037,7 @@ 1037 1037 1038 1038 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)** 1039 1039 1040 - (% style="color:blue" %)**0xA9 aa bb cc **(%%)~/~/ Set DO1/DO2/DO3 output with time control1049 +**0xA9 aa bb cc **~/~/ Set DO1/DO2/DO3 output with time control 1041 1041 1042 1042 1043 1043 This is to control the digital output time of DO pin. Include four bytes: ... ... @@ -1093,6 +1093,7 @@ 1093 1093 1094 1094 1095 1095 1105 + 1096 1096 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1097 1097 1098 1098 ... ... @@ -1103,7 +1103,7 @@ 1103 1103 1104 1104 * (% style="color:#037691" %)**Downlink Payload (prefix 0x03):** 1105 1105 1106 - (% style="color:blue" %)**0x03 aa bb **(%%)~/~/ Set RO1/RO2 output1116 +**0x03 aa bb **~/~/ Set RO1/RO2 output 1107 1107 1108 1108 1109 1109 ((( ... ... @@ -1133,7 +1133,7 @@ 1133 1133 1134 1134 * (% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1135 1135 1136 - (% style="color:blue" %)**0x05 aa bb cc dd **(%%)~/~/ Set RO1/RO2 relay with time control1146 +**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1137 1137 1138 1138 1139 1139 This is to control the relay output time of relay. Include four bytes: ... ... @@ -1184,33 +1184,39 @@ 1184 1184 1185 1185 * (% style="color:#037691" %)**AT Command:** 1186 1186 1187 - (% style="color:blue" %)**AT+VOLMAX **(%%)~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]1197 +**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1188 1188 1189 1189 1190 1190 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1191 1191 1192 - (% style="color:blue" %)**0xA5 aa bb cc **(%%)~/~/ Same as AT+VOLMAX=(aa bb),cc1202 +**0xA5 aa bb cc **~/~/ Same as AT+VOLMAX=(aa bb),cc 1193 1193 1194 1194 1195 1195 1206 + 1196 1196 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1197 1197 1198 1198 1199 1199 * (% style="color:#037691" %)**AT Command:** 1200 1200 1201 - (% style="color:blue" %)**AT+SETCNT=aa,(bb cc dd ee) **1212 +**AT+SETCNT=aa,(bb cc dd ee) ** 1202 1202 1203 - (% style="color:red" %)**aa:**(%%)1: Set count1; 2: Set count2; 3: Set AV1 count1214 +aa: 1: Set count1, 1204 1204 1205 - (% style="color:red"%)**bb cc ddee:**(%%)numberto be set1216 +2: Set count2, 1206 1206 1218 +3: Set AV1 count 1207 1207 1220 +Bb cc dd ee: number to be set 1221 + 1222 + 1208 1208 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):** 1209 1209 1210 - (% style="color:blue" %)**0x A8 aa bb cc dd ee **(%%)~/~/ same as AT+SETCNT=aa,(bb cc dd ee)1225 +**0x A8 aa bb cc dd ee **~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1211 1211 1212 1212 1213 1213 1229 + 1214 1214 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1215 1215 1216 1216 ... ... @@ -1218,79 +1218,87 @@ 1218 1218 1219 1219 * (% style="color:#037691" %)**AT Command:** 1220 1220 1221 - (% style="color:blue" %)**AT+CLRCOUNT **(%%)~/~/ clear all counting1237 +**AT+CLRCOUNT ** ~/~/ clear all counting 1222 1222 1223 1223 1224 1224 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1225 1225 1226 - (% style="color:blue" %)**0x A6 01 **(%%)~/~/ clear all counting1242 +**0x A6 01 ** ~/~/ clear all counting 1227 1227 1228 1228 1229 1229 1246 + 1230 1230 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1231 1231 1232 1232 1233 1233 * (% style="color:#037691" %)**AT Command:** 1234 1234 1235 - (% style="color:blue" %)**AT+COUTIME=60 **(%%)~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)1252 +**AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1236 1236 1237 1237 1238 1238 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1239 1239 1240 - (% style="color:blue" %)**0x A7 aa bb cc **(%%)~/~/ same as AT+COUTIME =aa bb cc,1257 +**0x A7 aa bb cc **~/~/ same as AT+COUTIME =aa bb cc, 1241 1241 1242 1242 ((( 1243 1243 range: aa bb cc:0 to 16777215, (unit:second) 1244 -))) 1245 1245 1246 1246 1247 1247 1248 -==== 3.4.2.20 Reset save RO DO state ==== 1264 + 1265 +))) 1249 1249 1267 +==== 3.4.2.20 Reset save DR DO state ==== 1250 1250 1269 + 1251 1251 * (% style="color:#037691" %)**AT Command:** 1252 1252 1253 - (% style="color:blue" %)**AT+RODORESET=1(%%)~/~/ RODO will close when the device joining the network. (default)1272 +**AT+RODORET=1 **~/~/ RODO will close when the device joining the network. (default) 1254 1254 1255 - (% style="color:blue" %)**AT+RODORESET=0(%%)~/~/1274 +**AT+RODORET=0 **~/~/After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network. 1256 1256 1257 1257 1258 1258 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):** 1259 1259 1260 - (% style="color:blue" %)**0x AD aa **(%%)~/~/ same as AT+RODORET =aa1279 +**0x AD aa **~/~/ same as AT+RODORET =aa 1261 1261 1281 +((( 1282 + 1262 1262 1263 1263 1285 + 1264 1264 ==== 3.4.2.21 Encrypted payload ==== 1265 1265 1266 1266 1267 1267 * (% style="color:#037691" %)**AT Command:** 1268 1268 1269 - (% style="color:blue" %)**AT+DECRYPT=1 **(%%)~/~/ The payload is uploaded without encryption1291 +**AT+DECRYPT=1 **~/~/ The payload is uploaded without encryption 1270 1270 1271 - (% style="color:blue" %)**AT+DECRYPT=0(%%)~/~/1293 +**AT+DECRYPT=0 **~/~/Encrypt when uploading payload (default) 1272 1272 1273 1273 1274 1274 1297 + 1275 1275 ==== 3.4.2.22 Get sensor value ==== 1276 1276 1277 1277 1278 1278 * (% style="color:#037691" %)**AT Command:** 1279 1279 1280 - (% style="color:blue" %)**AT+GETSENSORVALUE=0(%%)~/~/ The serial port gets the reading of the current sensor1303 +**AT+GETSENSORVALUE=0 **~/~/ The serial port gets the reading of the current sensor 1281 1281 1282 - (% style="color:blue" %)**AT+GETSENSORVALUE=1(%%)~/~/1305 +**AT+GETSENSORVALUE=1 **~/~/The serial port gets the current sensor reading and uploads it. 1283 1283 1284 1284 1285 1285 1309 + 1286 1286 ==== 3.4.2.23 Resets the downlink packet count ==== 1287 1287 1288 1288 1289 1289 * (% style="color:#037691" %)**AT Command:** 1290 1290 1291 - (% style="color:blue" %)**AT+DISFCNTCHECK=0(%%)~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default)1315 +**AT+DISFCNTCHECK=0 **~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default) 1292 1292 1293 - (% style="color:blue" %)**AT+DISFCNTCHECK=1(%%)~/~/1317 +**AT+DISFCNTCHECK=1 **~/~/When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count. 1294 1294 1295 1295 1296 1296 ... ... @@ -1300,14 +1300,14 @@ 1300 1300 1301 1301 * (% style="color:#037691" %)**AT Command:** 1302 1302 1303 - (%style="color:blue"%)**AT+DISMACANS=0**(%%)~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default)1327 + **AT+DISMACANS=0** ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default) 1304 1304 1305 - (%style="color:blue"%)**AT+DISMACANS=1**(%%)~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part.1329 + **AT+DISMACANS=1** ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part. 1306 1306 1307 1307 1308 1308 * (% style="color:#037691" %)**Downlink Payload **(%%)**:** 1309 1309 1310 - (% style="color:blue" %)**0x21 00 01 **(%%)~/~/ Set the DISMACANS=11334 +**0x21 00 01 ** ~/~/ Set the DISMACANS=1 1311 1311 1312 1312 1313 1313 ... ... @@ -1317,7 +1317,7 @@ 1317 1317 1318 1318 * (% style="color:#037691" %)**AT Command**(%%)**:** 1319 1319 1320 - (%style="color:blue"%)**AT+RPL=5**(%%)~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100.1344 + **AT+RPL=5** ~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100. 1321 1321 1322 1322 Example:**aa xx xx xx xx** ~/~/ aa indicates whether the configuration has changed, 00 is yes, 01 is no; xx xx xx xx are the bytes sent. 1323 1323 ... ... @@ -1340,7 +1340,7 @@ 1340 1340 * ((( 1341 1341 (% style="color:#037691" %)**Downlink Payload**(%%)**:** 1342 1342 1343 - (% style="color:blue" %)**26 01 **(%%)~/~/ Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time.1367 +**26 01 ** ~/~/ Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time. 1344 1344 1345 1345 1346 1346 ))) ... ... @@ -1350,6 +1350,8 @@ 1350 1350 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]] 1351 1351 1352 1352 1377 + 1378 +))) 1353 1353 1354 1354 == 3.5 Integrate with Mydevice == 1355 1355 ... ... @@ -1538,10 +1538,8 @@ 1538 1538 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1539 1539 1540 1540 1541 - **NPN output**: GND or Float. Max voltage can apply to output pin is 36v.1567 +NPN output: GND or Float. Max voltage can apply to output pin is 36v. 1542 1542 1543 -Note: DO pins go to float when device is power off. 1544 - 1545 1545 [[image:1653357531600-905.png]] 1546 1546 1547 1547 ... ... @@ -1582,9 +1582,7 @@ 1582 1582 1583 1583 1584 1584 ((( 1585 -The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device's Power Line to in serial of RO1_1 and RO_2. Such as below: 1586 - 1587 -**Note**: RO pins go to Open(NO) when device is power off. 1609 +The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device’s Power Line to in serial of RO1_1 and RO_2. Such as below: 1588 1588 ))) 1589 1589 1590 1590 [[image:image-20220524100215-9.png]] ... ... @@ -1953,7 +1953,7 @@ 1953 1953 1954 1954 1955 1955 ((( 1956 -(% style="color:blue" %) **If sensor JOINED:**1978 +(% style="color:blue" %)If sensor JOINED: 1957 1957 1958 1958 (% style="background-color:#dcdcdc" %)**AT+CLASS=A 1959 1959 ATZ** ... ... @@ -2038,6 +2038,7 @@ 2038 2038 ((( 2039 2039 Assume we have a LG02 working in the frequency 868400000 now , below is the step. 2040 2040 2063 + 2041 2041 2042 2042 ))) 2043 2043 ))) ... ... @@ -2098,7 +2098,7 @@ 2098 2098 == 5.5 Can i use point to point communication for LT-22222-L? == 2099 2099 2100 2100 2101 -Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https://github.com/dragino/LT-22222-L/releases]].2124 +Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 2102 2102 2103 2103 2104 2104 ... ... @@ -2127,13 +2127,7 @@ 2127 2127 [[image:image-20221006170630-1.png||height="610" width="945"]] 2128 2128 2129 2129 2130 -== 5.8 Can LT22222-L save RO state? == 2131 2131 2132 - 2133 -Firmware version needs to be no less than 1.6.0. 2134 - 2135 - 2136 - 2137 2137 = 6. Trouble Shooting = 2138 2138 2139 2139 ... ... @@ -2196,6 +2196,8 @@ 2196 2196 * (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 2197 2197 * (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 2198 2198 2216 + 2217 + 2199 2199 = 8. Packing Info = 2200 2200 2201 2201 ... ... @@ -2213,6 +2213,8 @@ 2213 2213 * Package Size / pcs : 14.5 x 8 x 5 cm 2214 2214 * Weight / pcs : 170g 2215 2215 2235 + 2236 + 2216 2216 = 9. Support = 2217 2217 2218 2218 ... ... @@ -2223,6 +2223,7 @@ 2223 2223 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 2224 2224 2225 2225 2247 + 2226 2226 2227 2227 ))) 2228 2228
- image-20221112174847-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -102.6 KB - Content