Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Xiaoling - Content
-
... ... @@ -15,7 +15,6 @@ 15 15 16 16 = 1.Introduction = 17 17 18 - 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( ... ... @@ -54,7 +54,6 @@ 54 54 55 55 ))) 56 56 57 - 58 58 == 1.2 Specifications == 59 59 60 60 ((( ... ... @@ -171,7 +171,6 @@ 171 171 Packet engine up to 256 bytes with CRC. 172 172 173 173 174 - 175 175 176 176 ))) 177 177 ... ... @@ -226,10 +226,8 @@ 226 226 [[image:1653297104069-180.png]] 227 227 228 228 229 - 230 230 = 3. Operation Mode = 231 231 232 - 233 233 == 3.1 How it works? == 234 234 235 235 ... ... @@ -242,7 +242,6 @@ 242 242 ))) 243 243 244 244 245 - 246 246 == 3.2 Example to join LoRaWAN network == 247 247 248 248 ... ... @@ -294,7 +294,6 @@ 294 294 [[image:1653298044601-602.png||height="405" width="709"]] 295 295 296 296 297 - 298 298 == 3.3 Uplink Payload == 299 299 300 300 ... ... @@ -436,7 +436,6 @@ 436 436 ))) 437 437 438 438 439 - 440 440 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 441 441 442 442 ... ... @@ -483,7 +483,6 @@ 483 483 ))) 484 484 485 485 486 - 487 487 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 488 488 489 489 ... ... @@ -552,7 +552,6 @@ 552 552 ))) 553 553 554 554 555 - 556 556 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 557 557 558 558 ... ... @@ -600,7 +600,6 @@ 600 600 ))) 601 601 602 602 603 - 604 604 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 605 605 606 606 ... ... @@ -655,7 +655,6 @@ 655 655 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 656 656 657 657 658 - 659 659 (% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 660 660 661 661 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** ... ... @@ -716,7 +716,6 @@ 716 716 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. 717 717 718 718 719 - 720 720 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 721 721 722 722 [[image:image-20220524090456-4.png]] ... ... @@ -730,7 +730,6 @@ 730 730 00000101: Means both DI1 and DI2 trigger are enabled. 731 731 732 732 733 - 734 734 (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable. 735 735 736 736 Downlink command to poll MOD6 status: ... ... @@ -740,7 +740,6 @@ 740 740 When device got this command, it will send the MOD6 payload. 741 741 742 742 743 - 744 744 === 3.3.7 Payload Decoder === 745 745 746 746 ((( ... ... @@ -750,7 +750,6 @@ 750 750 ))) 751 751 752 752 753 - 754 754 == 3.4 Configure LT via AT or Downlink == 755 755 756 756 ... ... @@ -776,10 +776,8 @@ 776 776 ))) 777 777 778 778 779 - 780 780 === 3.4.2 Sensor related commands === 781 781 782 - 783 783 ==== 3.4.2.1 Set Transmit Interval ==== 784 784 785 785 ... ... @@ -855,7 +855,6 @@ 855 855 856 856 857 857 858 - 859 859 ==== 3.4.2.5 Poll trigger settings ==== 860 860 861 861 ... ... @@ -938,7 +938,7 @@ 938 938 939 939 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 940 940 941 -(% style="color:blue" %)**0x09 02 aa bb cc ** (%%)~/~/ same as AT+TRIG 1=aa,0x(bb cc)922 +(% style="color:blue" %)**0x09 02 aa bb cc ** (%%)~/~/ same as AT+TRIG2=aa,0x(bb cc) 942 942 943 943 944 944 ... ... @@ -1070,6 +1070,14 @@ 1070 1070 1071 1071 Latching time. Unit: ms 1072 1072 1054 + 1055 +(% style="color:red" %)**Note: ** 1056 + 1057 + Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1058 + 1059 + Before Firmwre v1.6.0 the latch time only suport 2 bytes. 1060 + 1061 + 1073 1073 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1074 1074 1075 1075 ... ... @@ -1093,7 +1093,7 @@ 1093 1093 1094 1094 1095 1095 1096 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1085 +==== 3.4.2. 14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1097 1097 1098 1098 1099 1099 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1122,7 +1122,6 @@ 1122 1122 1123 1123 1124 1124 1125 - 1126 1126 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1127 1127 1128 1128 ... ... @@ -1154,12 +1154,20 @@ 1154 1154 1155 1155 (% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms 1156 1156 1145 + 1146 +(% style="color:red" %)**Note:** 1147 + 1148 + Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1149 + 1150 + Before Firmwre v1.6.0 the latch time only suport 2 bytes. 1151 + 1152 + 1157 1157 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1158 1158 1159 1159 1160 1160 **Example payload:** 1161 1161 1162 -**~1. 05 01 11 07 D** 1158 +**~1. 05 01 11 07 D0** 1163 1163 1164 1164 Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state. 1165 1165 ... ... @@ -1294,7 +1294,6 @@ 1294 1294 1295 1295 1296 1296 1297 - 1298 1298 ==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ==== 1299 1299 1300 1300 ... ... @@ -1311,7 +1311,6 @@ 1311 1311 1312 1312 1313 1313 1314 - 1315 1315 ==== 3.4.2.25 Copy downlink to uplink ==== 1316 1316 1317 1317 ... ... @@ -1350,7 +1350,6 @@ 1350 1350 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]] 1351 1351 1352 1352 1353 - 1354 1354 == 3.5 Integrate with Mydevice == 1355 1355 1356 1356 ... ... @@ -1400,10 +1400,8 @@ 1400 1400 [[image:image-20220524094909-5.png||height="341" width="734"]] 1401 1401 1402 1402 1403 - 1404 1404 == 3.6 Interface Detail == 1405 1405 1406 - 1407 1407 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === 1408 1408 1409 1409 ... ... @@ -1412,7 +1412,6 @@ 1412 1412 [[image:1653356991268-289.png]] 1413 1413 1414 1414 1415 - 1416 1416 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1417 1417 1418 1418 ... ... @@ -1469,8 +1469,6 @@ 1469 1469 1470 1470 ((( 1471 1471 1472 - 1473 - 1474 1474 ))) 1475 1475 1476 1476 ((( ... ... @@ -1502,8 +1502,6 @@ 1502 1502 1503 1503 ((( 1504 1504 1505 - 1506 - 1507 1507 ))) 1508 1508 1509 1509 ((( ... ... @@ -1534,7 +1534,6 @@ 1534 1534 ))) 1535 1535 1536 1536 1537 - 1538 1538 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1539 1539 1540 1540 ... ... @@ -1545,7 +1545,6 @@ 1545 1545 [[image:1653357531600-905.png]] 1546 1546 1547 1547 1548 - 1549 1549 === 3.6.4 Analog Input Interface === 1550 1550 1551 1551 ... ... @@ -1577,7 +1577,6 @@ 1577 1577 [[image:1653357648330-671.png||height="155" width="733"]] 1578 1578 1579 1579 1580 - 1581 1581 === 3.6.5 Relay Output === 1582 1582 1583 1583 ... ... @@ -1593,7 +1593,6 @@ 1593 1593 [[image:image-20220524100215-10.png||height="382" width="723"]] 1594 1594 1595 1595 1596 - 1597 1597 == 3.7 LEDs Indicators == 1598 1598 1599 1599 ... ... @@ -1600,10 +1600,8 @@ 1600 1600 [[image:image-20220524100748-11.png]] 1601 1601 1602 1602 1603 - 1604 1604 = 4. Use AT Command = 1605 1605 1606 - 1607 1607 == 4.1 Access AT Command == 1608 1608 1609 1609 ... ... @@ -1814,10 +1814,8 @@ 1814 1814 ))) 1815 1815 1816 1816 1817 - 1818 1818 == 4.2 Common AT Command Sequence == 1819 1819 1820 - 1821 1821 === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1822 1822 1823 1823 ((( ... ... @@ -1862,7 +1862,6 @@ 1862 1862 ))) 1863 1863 1864 1864 1865 - 1866 1866 === 4.2.2 Single-channel ABP mode (Use with LG01/LG02) === 1867 1867 1868 1868 ((( ... ... @@ -1948,7 +1948,6 @@ 1948 1948 1949 1949 ))) 1950 1950 1951 - 1952 1952 === 4.2.3 Change to Class A === 1953 1953 1954 1954 ... ... @@ -1960,13 +1960,19 @@ 1960 1960 ))) 1961 1961 1962 1962 1939 += 5. Case Study = 1963 1963 1964 -= 5. F AQ=1941 +== 5.1 Counting how many objects pass in Flow Line == 1965 1965 1966 1966 1967 - ==5.1How to upgrade theimage?==1944 +Reference Link: [[How to set up to count objects pass in flow line>>How to set up to count objects pass in flow line]]? 1968 1968 1969 1969 1947 += 6. FAQ = 1948 + 1949 +== 6.1 How to upgrade the image? == 1950 + 1951 + 1970 1970 The LT LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to LT to: 1971 1971 1972 1972 * Support new features ... ... @@ -2007,10 +2007,8 @@ 2007 2007 2008 2008 ((( 2009 2009 ((( 2010 - 1992 +== 6.2 How to change the LoRa Frequency Bands/Region? == 2011 2011 2012 -== 5.2 How to change the LoRa Frequency Bands/Region? == 2013 - 2014 2014 2015 2015 ))) 2016 2016 ))) ... ... @@ -2022,9 +2022,8 @@ 2022 2022 ((( 2023 2023 2024 2024 2005 +== 6.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 2025 2025 2026 -== 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 2027 - 2028 2028 2029 2029 ))) 2030 2030 ... ... @@ -2086,26 +2086,23 @@ 2086 2086 [[image:1653360498588-932.png||height="485" width="726"]] 2087 2087 2088 2088 2068 +== 6.4 Can I see counting event in Serial? == 2089 2089 2090 -== 5.4 Can I see counting event in Serial? == 2091 2091 2092 - 2093 2093 ((( 2094 2094 User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 2095 2095 2096 2096 2075 +== 6.5 Can i use point to point communication for LT-22222-L? == 2097 2097 2098 -== 5.5 Can i use point to point communication for LT-22222-L? == 2099 2099 2078 +Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https://github.com/dragino/LT-22222-L/releases]]. 2100 2100 2101 -Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AADKXQ2v5ZT-S3sxdmbvE7UAa/LT-22222-L/image?dl=0&subfolder_nav_tracking=1]]. 2102 - 2103 - 2104 2104 2105 2105 ))) 2106 2106 2107 2107 ((( 2108 -== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==2084 +== 6.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 2109 2109 2110 2110 2111 2111 If the device is not shut down, but directly powered off. ... ... @@ -2117,10 +2117,9 @@ 2117 2117 After restart, the status before power failure will be read from flash. 2118 2118 2119 2119 2096 +== 6.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? == 2120 2120 2121 -== 5.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? == 2122 2122 2123 - 2124 2124 LT-22222-L built-in relay is NO (Normal Open). User can use an external relay to achieve Normal Close purpose. Diagram as below: 2125 2125 2126 2126 ... ... @@ -2127,21 +2127,18 @@ 2127 2127 [[image:image-20221006170630-1.png||height="610" width="945"]] 2128 2128 2129 2129 2130 -== 5.8 Can LT22222-L save RO state? ==2105 +== 6.8 Can LT22222-L save RO state? == 2131 2131 2132 2132 2133 2133 Firmware version needs to be no less than 1.6.0. 2134 2134 2135 2135 2136 - 2137 -= 6. Trouble Shooting = 2138 - 2139 - 2111 += 7. Trouble Shooting = 2140 2140 ))) 2141 2141 2142 2142 ((( 2143 2143 ((( 2144 -== 6.1 Downlink doesn't work, how to solve it? ==2116 +== 7.1 Downlink doesn't work, how to solve it? == 2145 2145 2146 2146 2147 2147 ))) ... ... @@ -2154,9 +2154,8 @@ 2154 2154 ((( 2155 2155 2156 2156 2129 +== 7.2 Have trouble to upload image. == 2157 2157 2158 -== 6.2 Have trouble to upload image. == 2159 - 2160 2160 2161 2161 ))) 2162 2162 ... ... @@ -2167,9 +2167,8 @@ 2167 2167 ((( 2168 2168 2169 2169 2141 +== 7.3 Why I can't join TTN in US915 /AU915 bands? == 2170 2170 2171 -== 6.3 Why I can't join TTN in US915 /AU915 bands? == 2172 - 2173 2173 2174 2174 ))) 2175 2175 ... ... @@ -2178,10 +2178,9 @@ 2178 2178 ))) 2179 2179 2180 2180 2151 += 8. Order Info = 2181 2181 2182 -= 7. Order Info = 2183 2183 2184 - 2185 2185 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 2186 2186 2187 2187 (% style="color:#4f81bd" %)**XXX:** ... ... @@ -2196,7 +2196,7 @@ 2196 2196 * (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 2197 2197 * (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 2198 2198 2199 -= 8. Packing Info =2168 += 9. Packing Info = 2200 2200 2201 2201 2202 2202 **Package Includes**: ... ... @@ -2213,7 +2213,7 @@ 2213 2213 * Package Size / pcs : 14.5 x 8 x 5 cm 2214 2214 * Weight / pcs : 170g 2215 2215 2216 -= 9. Support =2185 += 10. Support = 2217 2217 2218 2218 2219 2219 * ((( ... ... @@ -2226,9 +2226,11 @@ 2226 2226 2227 2227 ))) 2228 2228 2229 -= 1 0. Reference =2198 += 11. Reference = 2230 2230 2231 2231 2232 2232 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2233 2233 * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 2234 2234 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 2204 + 2205 +