Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -15,7 +15,6 @@ 15 15 16 16 = 1.Introduction = 17 17 18 - 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( ... ... @@ -54,7 +54,6 @@ 54 54 55 55 ))) 56 56 57 - 58 58 == 1.2 Specifications == 59 59 60 60 ((( ... ... @@ -64,7 +64,7 @@ 64 64 ))) 65 65 66 66 * ((( 67 -STM32L072 CZT6MCU65 +STM32L072xxxx MCU 68 68 ))) 69 69 * ((( 70 70 SX1276/78 Wireless Chip ... ... @@ -171,7 +171,6 @@ 171 171 Packet engine up to 256 bytes with CRC. 172 172 173 173 174 - 175 175 176 176 ))) 177 177 ... ... @@ -229,10 +229,8 @@ 229 229 [[image:1653297104069-180.png]] 230 230 231 231 232 - 233 233 = 3. Operation Mode = 234 234 235 - 236 236 == 3.1 How it works? == 237 237 238 238 ... ... @@ -245,7 +245,6 @@ 245 245 ))) 246 246 247 247 248 - 249 249 == 3.2 Example to join LoRaWAN network == 250 250 251 251 ... ... @@ -297,7 +297,6 @@ 297 297 [[image:1653298044601-602.png||height="405" width="709"]] 298 298 299 299 300 - 301 301 == 3.3 Uplink Payload == 302 302 303 303 ... ... @@ -441,7 +441,6 @@ 441 441 ))) 442 442 443 443 444 - 445 445 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 446 446 447 447 ... ... @@ -488,7 +488,6 @@ 488 488 ))) 489 489 490 490 491 - 492 492 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 493 493 494 494 ... ... @@ -557,7 +557,6 @@ 557 557 ))) 558 558 559 559 560 - 561 561 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 562 562 563 563 ... ... @@ -605,7 +605,6 @@ 605 605 ))) 606 606 607 607 608 - 609 609 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 610 610 611 611 ... ... @@ -660,7 +660,6 @@ 660 660 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 661 661 662 662 663 - 664 664 (% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 665 665 666 666 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** ... ... @@ -721,7 +721,6 @@ 721 721 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. 722 722 723 723 724 - 725 725 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 726 726 727 727 [[image:image-20220524090456-4.png]] ... ... @@ -735,7 +735,6 @@ 735 735 00000101: Means both DI1 and DI2 trigger are enabled. 736 736 737 737 738 - 739 739 (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable. 740 740 741 741 Downlink command to poll MOD6 status: ... ... @@ -745,7 +745,6 @@ 745 745 When device got this command, it will send the MOD6 payload. 746 746 747 747 748 - 749 749 === 3.3.7 Payload Decoder === 750 750 751 751 ((( ... ... @@ -755,7 +755,6 @@ 755 755 ))) 756 756 757 757 758 - 759 759 == 3.4 Configure LT via AT or Downlink == 760 760 761 761 ... ... @@ -782,10 +782,8 @@ 782 782 ))) 783 783 784 784 785 - 786 786 === 3.4.2 Sensor related commands === 787 787 788 - 789 789 ==== 3.4.2.1 Set Transmit Interval ==== 790 790 791 791 ... ... @@ -861,7 +861,6 @@ 861 861 862 862 863 863 864 - 865 865 ==== 3.4.2.5 Poll trigger settings ==== 866 866 867 867 ... ... @@ -944,7 +944,7 @@ 944 944 945 945 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 946 946 947 -(% style="color:blue" %)**0x09 02 aa bb cc ** (%%)~/~/ same as AT+TRIG 1=aa,0x(bb cc)928 +(% style="color:blue" %)**0x09 02 aa bb cc ** (%%)~/~/ same as AT+TRIG2=aa,0x(bb cc) 948 948 949 949 950 950 ... ... @@ -1076,6 +1076,14 @@ 1076 1076 1077 1077 Latching time. Unit: ms 1078 1078 1060 + 1061 +(% style="color:red" %)**Note: ** 1062 + 1063 + Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1064 + 1065 + Before Firmwre v1.6.0 the latch time only suport 2 bytes. 1066 + 1067 + 1079 1079 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1080 1080 1081 1081 ... ... @@ -1099,7 +1099,7 @@ 1099 1099 1100 1100 1101 1101 1102 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1091 +==== 3.4.2. 14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1103 1103 1104 1104 1105 1105 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1128,7 +1128,6 @@ 1128 1128 1129 1129 1130 1130 1131 - 1132 1132 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1133 1133 1134 1134 ... ... @@ -1160,12 +1160,20 @@ 1160 1160 1161 1161 (% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms 1162 1162 1151 + 1152 +(% style="color:red" %)**Note:** 1153 + 1154 + Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1155 + 1156 + Before Firmwre v1.6.0 the latch time only suport 2 bytes. 1157 + 1158 + 1163 1163 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1164 1164 1165 1165 1166 1166 **Example payload:** 1167 1167 1168 -**~1. 05 01 11 07 D** 1164 +**~1. 05 01 11 07 D0** 1169 1169 1170 1170 Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state. 1171 1171 ... ... @@ -1251,14 +1251,14 @@ 1251 1251 1252 1252 1253 1253 1254 -==== 3.4.2.20 Reset save DR DO state ====1250 +==== 3.4.2.20 Reset save RO DO state ==== 1255 1255 1256 1256 1257 1257 * (% style="color:#037691" %)**AT Command:** 1258 1258 1259 -(% style="color:blue" %)**AT+RODORET=1 **(%%)~/~/ RODO will close when the device joining the network. (default) 1255 +(% style="color:blue" %)**AT+RODORESET=1 **(%%)~/~/ RODO will close when the device joining the network. (default) 1260 1260 1261 -(% style="color:blue" %)**AT+RODORET=0 **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network. 1257 +(% style="color:blue" %)**AT+RODORESET=0 **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network. 1262 1262 1263 1263 1264 1264 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):** ... ... @@ -1300,7 +1300,6 @@ 1300 1300 1301 1301 1302 1302 1303 - 1304 1304 ==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ==== 1305 1305 1306 1306 ... ... @@ -1317,7 +1317,6 @@ 1317 1317 1318 1318 1319 1319 1320 - 1321 1321 ==== 3.4.2.25 Copy downlink to uplink ==== 1322 1322 1323 1323 ... ... @@ -1356,7 +1356,6 @@ 1356 1356 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]] 1357 1357 1358 1358 1359 - 1360 1360 == 3.5 Integrate with Mydevice == 1361 1361 1362 1362 ... ... @@ -1406,10 +1406,8 @@ 1406 1406 [[image:image-20220524094909-5.png||height="341" width="734"]] 1407 1407 1408 1408 1409 - 1410 1410 == 3.6 Interface Detail == 1411 1411 1412 - 1413 1413 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === 1414 1414 1415 1415 ... ... @@ -1418,7 +1418,6 @@ 1418 1418 [[image:1653356991268-289.png]] 1419 1419 1420 1420 1421 - 1422 1422 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1423 1423 1424 1424 ... ... @@ -1475,8 +1475,6 @@ 1475 1475 1476 1476 ((( 1477 1477 1478 - 1479 - 1480 1480 ))) 1481 1481 1482 1482 ((( ... ... @@ -1508,8 +1508,6 @@ 1508 1508 1509 1509 ((( 1510 1510 1511 - 1512 - 1513 1513 ))) 1514 1514 1515 1515 ((( ... ... @@ -1540,7 +1540,6 @@ 1540 1540 ))) 1541 1541 1542 1542 1543 - 1544 1544 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1545 1545 1546 1546 ... ... @@ -1551,7 +1551,6 @@ 1551 1551 [[image:1653357531600-905.png]] 1552 1552 1553 1553 1554 - 1555 1555 === 3.6.4 Analog Input Interface === 1556 1556 1557 1557 ... ... @@ -1583,12 +1583,11 @@ 1583 1583 [[image:1653357648330-671.png||height="155" width="733"]] 1584 1584 1585 1585 1586 - 1587 1587 === 3.6.5 Relay Output === 1588 1588 1589 1589 1590 1590 ((( 1591 -The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device ’s Power Line to in serial of RO1_1 and RO_2. Such as below:1574 +The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device's Power Line to in serial of RO1_1 and RO_2. Such as below: 1592 1592 1593 1593 **Note**: RO pins go to Open(NO) when device is power off. 1594 1594 ))) ... ... @@ -1599,7 +1599,6 @@ 1599 1599 [[image:image-20220524100215-10.png||height="382" width="723"]] 1600 1600 1601 1601 1602 - 1603 1603 == 3.7 LEDs Indicators == 1604 1604 1605 1605 ... ... @@ -1606,10 +1606,8 @@ 1606 1606 [[image:image-20220524100748-11.png]] 1607 1607 1608 1608 1609 - 1610 1610 = 4. Use AT Command = 1611 1611 1612 - 1613 1613 == 4.1 Access AT Command == 1614 1614 1615 1615 ... ... @@ -1820,10 +1820,8 @@ 1820 1820 ))) 1821 1821 1822 1822 1823 - 1824 1824 == 4.2 Common AT Command Sequence == 1825 1825 1826 - 1827 1827 === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1828 1828 1829 1829 ((( ... ... @@ -1868,7 +1868,6 @@ 1868 1868 ))) 1869 1869 1870 1870 1871 - 1872 1872 === 4.2.2 Single-channel ABP mode (Use with LG01/LG02) === 1873 1873 1874 1874 ((( ... ... @@ -1954,7 +1954,6 @@ 1954 1954 1955 1955 ))) 1956 1956 1957 - 1958 1958 === 4.2.3 Change to Class A === 1959 1959 1960 1960 ... ... @@ -1966,10 +1966,16 @@ 1966 1966 ))) 1967 1967 1968 1968 1945 += 5. Case Study = 1969 1969 1970 -= 5. F AQ=1947 +== 5.1 Counting how many objects pass in Flow Line == 1971 1971 1972 1972 1950 +Reference Link: [[How to set up to count objects pass in flow line>>How to set up to count objects pass in flow line]]? 1951 + 1952 + 1953 += 5. FAQ = 1954 + 1973 1973 == 5.1 How to upgrade the image? == 1974 1974 1975 1975 ... ... @@ -2013,8 +2013,6 @@ 2013 2013 2014 2014 ((( 2015 2015 ((( 2016 - 2017 - 2018 2018 == 5.2 How to change the LoRa Frequency Bands/Region? == 2019 2019 2020 2020 ... ... @@ -2028,7 +2028,6 @@ 2028 2028 ((( 2029 2029 2030 2030 2031 - 2032 2032 == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 2033 2033 2034 2034 ... ... @@ -2092,7 +2092,6 @@ 2092 2092 [[image:1653360498588-932.png||height="485" width="726"]] 2093 2093 2094 2094 2095 - 2096 2096 == 5.4 Can I see counting event in Serial? == 2097 2097 2098 2098 ... ... @@ -2100,13 +2100,11 @@ 2100 2100 User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 2101 2101 2102 2102 2103 - 2104 2104 == 5.5 Can i use point to point communication for LT-22222-L? == 2105 2105 2106 2106 2107 -Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https:// www.dropbox.com/sh/g99v0fxcltn9r1y/AADKXQ2v5ZT-S3sxdmbvE7UAa/LT-22222-L/image?dl=0&subfolder_nav_tracking=1]].2084 +Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https://github.com/dragino/LT-22222-L/releases]]. 2108 2108 2109 - 2110 2110 2111 2111 ))) 2112 2112 ... ... @@ -2123,7 +2123,6 @@ 2123 2123 After restart, the status before power failure will be read from flash. 2124 2124 2125 2125 2126 - 2127 2127 == 5.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? == 2128 2128 2129 2129 ... ... @@ -2139,10 +2139,7 @@ 2139 2139 Firmware version needs to be no less than 1.6.0. 2140 2140 2141 2141 2142 - 2143 2143 = 6. Trouble Shooting = 2144 - 2145 - 2146 2146 ))) 2147 2147 2148 2148 ((( ... ... @@ -2160,7 +2160,6 @@ 2160 2160 ((( 2161 2161 2162 2162 2163 - 2164 2164 == 6.2 Have trouble to upload image. == 2165 2165 2166 2166 ... ... @@ -2173,7 +2173,6 @@ 2173 2173 ((( 2174 2174 2175 2175 2176 - 2177 2177 == 6.3 Why I can't join TTN in US915 /AU915 bands? == 2178 2178 2179 2179 ... ... @@ -2184,7 +2184,6 @@ 2184 2184 ))) 2185 2185 2186 2186 2187 - 2188 2188 = 7. Order Info = 2189 2189 2190 2190 ... ... @@ -2240,3 +2240,5 @@ 2240 2240 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2241 2241 * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 2242 2242 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 2212 + 2213 +