Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Xiaoling - Content
-
... ... @@ -15,16 +15,13 @@ 15 15 16 16 = 1.Introduction = 17 17 18 - 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 22 23 23 24 -((( 25 25 The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 26 26 ))) 27 -))) 28 28 29 29 ((( 30 30 The LT I/O Controllers allows the user to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on. ... ... @@ -60,7 +60,7 @@ 60 60 ((( 61 61 62 62 63 - (% style="color:#037691" %)**Hardware System:**60 +**Hardware System:** 64 64 ))) 65 65 66 66 * ((( ... ... @@ -85,7 +85,7 @@ 85 85 ((( 86 86 87 87 88 - (% style="color:#037691" %)**Interface for Model: LT22222-L:**85 +**Interface for Model: LT22222-L:** 89 89 ))) 90 90 91 91 * ((( ... ... @@ -110,7 +110,7 @@ 110 110 ((( 111 111 112 112 113 - (% style="color:#037691" %)**LoRa Spec:**110 +**LoRa Spec:** 114 114 ))) 115 115 116 116 * ((( ... ... @@ -180,7 +180,7 @@ 180 180 181 181 * LoRaWAN Class A & Class C protocol 182 182 * Optional Customized LoRa Protocol 183 -* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865 /MA869180 +* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865 184 184 * AT Commands to change parameters 185 185 * Remote configure parameters via LoRa Downlink 186 186 * Firmware upgradable via program port ... ... @@ -187,6 +187,9 @@ 187 187 * Counting 188 188 189 189 187 + 188 + 189 + 190 190 == 1.4 Applications == 191 191 192 192 ... ... @@ -198,6 +198,9 @@ 198 198 * Smart Factory 199 199 200 200 201 + 202 + 203 + 201 201 == 1.5 Hardware Variants == 202 202 203 203 ... ... @@ -213,17 +213,15 @@ 213 213 ))) 214 214 215 215 219 + 220 + 216 216 = 2. Power ON Device = 217 217 218 218 219 -((( 220 220 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. 221 -))) 222 222 223 223 ((( 224 224 PWR will on when device is properly powered. 225 - 226 - 227 227 ))) 228 228 229 229 [[image:1653297104069-180.png]] ... ... @@ -232,7 +232,6 @@ 232 232 233 233 = 3. Operation Mode = 234 234 235 - 236 236 == 3.1 How it works? == 237 237 238 238 ... ... @@ -277,12 +277,12 @@ 277 277 278 278 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: 279 279 280 - **Add APP EUI in the application.**280 +Add APP EUI in the application. 281 281 282 282 [[image:1653297955910-247.png||height="321" width="716"]] 283 283 284 284 285 - **Add APP KEY and DEV EUI**285 +Add APP KEY and DEV EUI 286 286 287 287 [[image:1653298023685-319.png]] 288 288 ... ... @@ -290,8 +290,6 @@ 290 290 291 291 ((( 292 292 (% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 293 - 294 - 295 295 ))) 296 296 297 297 [[image:1653298044601-602.png||height="405" width="709"]] ... ... @@ -312,12 +312,12 @@ 312 312 313 313 314 314 313 + 314 + 315 315 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 316 316 317 317 318 -((( 319 319 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. 320 -))) 321 321 322 322 [[image:image-20220523174024-3.png]] 323 323 ... ... @@ -333,7 +333,7 @@ 333 333 * DI is for digital input. DIx=1: high or float, DIx=0: low. 334 334 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 335 335 336 -(% style="color:red" %) **Note: DI3 and DO3 bit are not valid for LT-22222-L**334 +(% style="color:red" %)Note: DI3 and DO3 bit are not valid for LT-22222-L 337 337 338 338 For example if payload is: [[image:image-20220523175847-2.png]] 339 339 ... ... @@ -370,12 +370,12 @@ 370 370 371 371 372 372 371 + 372 + 373 373 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 374 374 375 375 376 -((( 377 377 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. 378 -))) 379 379 380 380 ((( 381 381 Total : 11 bytes payload ... ... @@ -395,7 +395,7 @@ 395 395 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 396 396 397 397 ((( 398 -(% style="color:red" %) **Note: DO3 bit is not valid for LT-22222-L.**396 +(% style="color:red" %)Note: DO3 bit is not valid for LT-22222-L. 399 399 ))) 400 400 401 401 ((( ... ... @@ -407,22 +407,16 @@ 407 407 (% class="box infomessage" %) 408 408 ((( 409 409 ((( 410 -((( 411 411 **AT+MOD=2** 412 -))) 413 413 414 -((( 415 415 **ATZ** 416 416 ))) 417 417 ))) 418 -))) 419 419 420 420 ((( 421 421 422 422 423 423 (% style="color:#4f81bd" %)**AT Commands for counting:** 424 - 425 - 426 426 ))) 427 427 428 428 ((( ... ... @@ -464,7 +464,7 @@ 464 464 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 465 465 466 466 ((( 467 -(% style="color:red" %) **Note: DO3 is not valid for LT-22222-L.**459 +(% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 468 468 ))) 469 469 470 470 ... ... @@ -475,15 +475,11 @@ 475 475 (% class="box infomessage" %) 476 476 ((( 477 477 ((( 478 -((( 479 479 **AT+MOD=3** 480 -))) 481 481 482 -((( 483 483 **ATZ** 484 484 ))) 485 485 ))) 486 -))) 487 487 488 488 ((( 489 489 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. ... ... @@ -494,13 +494,9 @@ 494 494 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 495 495 496 496 497 -((( 498 498 **LT22222-L**: This mode the DI1 is used as a counting pin. 499 -))) 500 500 501 -((( 502 502 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. 503 -))) 504 504 505 505 [[image:image-20220523181903-8.png]] 506 506 ... ... @@ -516,7 +516,7 @@ 516 516 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 517 517 518 518 ((( 519 -(% style="color:red" %) **Note: DO3 is not valid for LT-22222-L.**503 +(% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 520 520 ))) 521 521 522 522 ((( ... ... @@ -528,17 +528,14 @@ 528 528 (% class="box infomessage" %) 529 529 ((( 530 530 ((( 531 -((( 532 532 **AT+MOD=4** 533 -))) 534 534 535 -((( 536 536 **ATZ** 537 537 ))) 538 538 ))) 539 -))) 540 540 541 541 522 + 542 542 ((( 543 543 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 544 544 ))) ... ... @@ -580,7 +580,7 @@ 580 580 ))) 581 581 582 582 ((( 583 -(% style="color:red" %) **Note: DO3 is not valid for LT-22222-L.**564 +(% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 584 584 ))) 585 585 586 586 ((( ... ... @@ -592,15 +592,11 @@ 592 592 (% class="box infomessage" %) 593 593 ((( 594 594 ((( 595 -((( 596 596 **AT+MOD=5** 597 -))) 598 598 599 -((( 600 600 **ATZ** 601 601 ))) 602 602 ))) 603 -))) 604 604 605 605 ((( 606 606 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. ... ... @@ -630,7 +630,6 @@ 630 630 631 631 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> 632 632 633 - 634 634 **Example:** 635 635 636 636 AT+AVLIM=3000,6000,0,2000 (If AVI1 voltage lower than 3v or higher than 6v. or AV2 voltage is higher than 2v, LT will trigger Uplink) ... ... @@ -643,7 +643,6 @@ 643 643 644 644 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> 645 645 646 - 647 647 **Example:** 648 648 649 649 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) ... ... @@ -662,7 +662,6 @@ 662 662 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 663 663 664 664 665 - 666 666 (% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 667 667 668 668 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** ... ... @@ -711,7 +711,6 @@ 711 711 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW 712 712 713 713 714 - 715 715 (% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1byte as below 716 716 717 717 [[image:image-20220524090249-3.png]] ... ... @@ -723,7 +723,6 @@ 723 723 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. 724 724 725 725 726 - 727 727 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 728 728 729 729 [[image:image-20220524090456-4.png]] ... ... @@ -737,7 +737,6 @@ 737 737 00000101: Means both DI1 and DI2 trigger are enabled. 738 738 739 739 740 - 741 741 (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable. 742 742 743 743 Downlink command to poll MOD6 status: ... ... @@ -753,7 +753,7 @@ 753 753 ((( 754 754 755 755 756 -**Decoder for TTN/loraserver/ChirpStack**: github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]727 +**Decoder for TTN/loraserver/ChirpStack**: [[https:~~/~~/www.dropbox.com/sh/wtrzu7avdtkmn3z/AACK5NwOMkU9jnvf1uCMuqrVa?dl=0>>https://www.dropbox.com/sh/wtrzu7avdtkmn3z/AACK5NwOMkU9jnvf1uCMuqrVa?dl=0]] 757 757 ))) 758 758 759 759 ... ... @@ -761,27 +761,23 @@ 761 761 == 3.4 Configure LT via AT or Downlink == 762 762 763 763 764 -((( 765 765 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands 766 -))) 767 767 768 768 ((( 769 -((( 770 770 There are two kinds of Commands: 771 771 ))) 772 -))) 773 773 774 -* (% style="color:b lue" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]741 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 775 775 776 -* (% style="color:b lue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below:743 +* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 777 777 778 778 746 + 747 + 779 779 === 3.4.1 Common Commands === 780 780 781 781 782 -((( 783 783 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 784 -))) 785 785 786 786 787 787 ... ... @@ -795,7 +795,7 @@ 795 795 796 796 * (% style="color:#037691" %)**AT Command:** 797 797 798 - (% style="color:blue" %)**AT+TDC=N **765 +**AT+TDC=N ** 799 799 800 800 801 801 **Example: **AT+TDC=30000. Means set interval to 30 seconds ... ... @@ -803,10 +803,11 @@ 803 803 804 804 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 805 805 806 - (% style="color:blue" %)**0x01 aa bb cc**(%%)**~/~/ Same as AT+TDC=0x(aa bb cc)**773 +**0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 807 807 808 808 809 809 777 + 810 810 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 811 811 812 812 ... ... @@ -814,7 +814,7 @@ 814 814 815 815 * (% style="color:#037691" %)**AT Command:** 816 816 817 - (% style="color:blue" %)**AT+MOD=N **785 +**AT+MOD=N ** 818 818 819 819 820 820 **Example**: AT+MOD=2. Set work mode to Double DI counting mode ... ... @@ -822,10 +822,11 @@ 822 822 823 823 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 824 824 825 - (% style="color:blue" %)**0x0A aa **(%%)****~/~/ Same as AT+MOD=aa793 +**0x0A aa ** ~/~/ Same as AT+MOD=aa 826 826 827 827 828 828 797 + 829 829 ==== 3.4.2.3 Poll an uplink ==== 830 830 831 831 ... ... @@ -836,13 +836,13 @@ 836 836 837 837 * (% style="color:#037691" %)**Downlink Payload (prefix 0x08):** 838 838 839 - (% style="color:blue" %)**0x08 FF **(%%)** **~/~/ Poll an uplink808 +**0x08 FF **~/~/ Poll an uplink 840 840 841 - 842 842 **Example**: 0x08FF, ask device to send an Uplink 843 843 844 844 845 845 814 + 846 846 ==== 3.4.2.4 Enable Trigger Mode ==== 847 847 848 848 ... ... @@ -850,16 +850,16 @@ 850 850 851 851 * (% style="color:#037691" %)**AT Command:** 852 852 853 - (% style="color:blue" %)**AT+ADDMOD6=1 or 0**822 +**AT+ADDMOD6=1 or 0** 854 854 855 - (% style="color:red" %)**1:**(%%)Enable Trigger Mode824 +1: Enable Trigger Mode 856 856 857 - (% style="color:red" %)**0:**(%%)Disable Trigger Mode826 +0: Disable Trigger Mode 858 858 859 859 860 860 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):** 861 861 862 - (% style="color:blue" %)**0x0A 06 aa **(%%)831 +**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 863 863 864 864 865 865 ... ... @@ -876,10 +876,11 @@ 876 876 877 877 * (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 878 878 879 - (% style="color:blue" %)**0xAB 06 **(%%)~/~/ Poll trigger settings, device will uplink trigger settings once receive this command848 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 880 880 881 881 882 882 852 + 883 883 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 884 884 885 885 ... ... @@ -887,7 +887,7 @@ 887 887 888 888 * (% style="color:#037691" %)**AT Command:** 889 889 890 - (% style="color:blue" %)**Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**860 +**Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 891 891 892 892 893 893 **Example:** ... ... @@ -896,10 +896,11 @@ 896 896 897 897 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 898 898 899 - (% style="color:blue" %)**0xAA 02 aa bb **(%%)~/~/ Same as AT+DTRI=aa,bb869 +**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 900 900 901 901 902 902 873 + 903 903 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 904 904 905 905 ... ... @@ -907,11 +907,11 @@ 907 907 908 908 * (% style="color:#037691" %)**AT Command:** 909 909 910 - (% style="color:blue" %)**AT+TRIG1=a,b**881 +**AT+TRIG1=a,b** 911 911 912 - (% style="color:red" %)**a :**(%%)Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).883 +a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 913 913 914 - (% style="color:red" %)**b :**(%%)delay timing.885 +b : delay timing. 915 915 916 916 917 917 **Example:** ... ... @@ -920,11 +920,12 @@ 920 920 921 921 922 922 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 894 +* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 923 923 924 -(% style="color:blue" %)**0x09 01 aa bb cc ** (%%) ~/~/ same as AT+TRIG1=aa,0x(bb cc) 925 925 926 926 927 927 899 + 928 928 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 929 929 930 930 ... ... @@ -932,13 +932,14 @@ 932 932 933 933 * (% style="color:#037691" %)**AT Command:** 934 934 935 - (% style="color:blue" %)**AT+TRIG2=a,b**907 +**AT+TRIG2=a,b** 936 936 937 -(% style="color:red" %)**a :** (%%)Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 938 938 939 - (%style="color:red"%)**b:**(%%)delaytiming.910 +a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 940 940 912 +b : delay timing. 941 941 914 + 942 942 **Example:** 943 943 944 944 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) ... ... @@ -946,10 +946,11 @@ 946 946 947 947 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 948 948 949 - (% style="color:blue" %)**0x09 02 aa bb cc **(%%)~/~/ same as AT+TRIG1=aa,0x(bb cc)922 +**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 950 950 951 951 952 952 926 + 953 953 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 954 954 955 955 ... ... @@ -957,15 +957,16 @@ 957 957 958 958 * (% style="color:#037691" %)**AT Command** 959 959 960 - (% style="color:blue" %)**AT+ACLIM**934 +**AT+ACLIM** 961 961 962 962 963 963 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )** 964 964 965 - (% style="color:blue" %)**0x AA 01 aa bb cc dd ee ff gg hh **(%%)~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]939 +**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 966 966 967 967 968 968 943 + 969 969 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 970 970 971 971 ... ... @@ -973,15 +973,16 @@ 973 973 974 974 * (% style="color:#037691" %)**AT Command** 975 975 976 - (% style="color:blue" %)**AT+AVLIM**(%%)**See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**951 +**AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 977 977 978 978 979 979 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )** 980 980 981 - (% style="color:blue" %)**0x AA 00 aa bb cc dd ee ff gg hh **(%%)~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]956 +**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 982 982 983 983 984 984 960 + 985 985 ==== 3.4.2.11 Trigger – Set minimum interval ==== 986 986 987 987 ... ... @@ -989,21 +989,22 @@ 989 989 990 990 * (% style="color:#037691" %)**AT Command** 991 991 992 - (% style="color:blue" %)**AT+ATDC=5 **(%%)Device won't response the second trigger within 5 minute after the first trigger.968 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 993 993 994 994 995 995 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** 996 996 997 - (% style="color:blue" %)**0x AC aa bb **(%%)~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)973 +**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 998 998 999 999 ((( 1000 1000 1001 1001 1002 -(% style="color:red" %) **Note: ATDC setting must be more than 5min**978 +(% style="color:red" %)Note: ATDC setting must be more than 5min 1003 1003 ))) 1004 1004 1005 1005 1006 1006 983 + 1007 1007 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1008 1008 1009 1009 ... ... @@ -1013,7 +1013,7 @@ 1013 1013 1014 1014 1015 1015 * (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 1016 -* (% style="color:blue" %)**0x02 aa bb cc **(%%)~/~/ Set DO1/DO2/DO3 output993 +* **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 1017 1017 1018 1018 ((( 1019 1019 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. ... ... @@ -1026,15 +1026,16 @@ 1026 1026 [[image:image-20220524092754-5.png]] 1027 1027 1028 1028 ((( 1029 -(% style="color:red" %) **Note: For LT-22222-L, there is no DO3, the last byte can use any value.**1006 +(% style="color:red" %)Note: For LT-22222-L, there is no DO3, the last byte can use any value. 1030 1030 ))) 1031 1031 1032 1032 ((( 1033 -(% style="color:red" %) **Device will upload a packet if downlink code executes successfully.**1010 +(% style="color:red" %)Device will upload a packet if downlink code executes successfully. 1034 1034 ))) 1035 1035 1036 1036 1037 1037 1015 + 1038 1038 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1039 1039 1040 1040 ... ... @@ -1045,7 +1045,7 @@ 1045 1045 1046 1046 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)** 1047 1047 1048 - (% style="color:blue" %)**0xA9 aa bb cc **(%%)~/~/ Set DO1/DO2/DO3 output with time control1026 +**0xA9 aa bb cc **~/~/ Set DO1/DO2/DO3 output with time control 1049 1049 1050 1050 1051 1051 This is to control the digital output time of DO pin. Include four bytes: ... ... @@ -1074,11 +1074,11 @@ 1074 1074 [[image:image-20220524093351-8.png]] 1075 1075 1076 1076 1077 -(% style="color:#4f81bd" %)**Sixth and Seventh and Eighth and NinthByte**:1055 +(% style="color:#4f81bd" %)**Sixth and Seventh Byte**: 1078 1078 1079 1079 Latching time. Unit: ms 1080 1080 1081 - (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**1059 +Device will upload a packet if downlink code executes successfully. 1082 1082 1083 1083 1084 1084 **Example payload:** ... ... @@ -1101,6 +1101,7 @@ 1101 1101 1102 1102 1103 1103 1082 + 1104 1104 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1105 1105 1106 1106 ... ... @@ -1111,7 +1111,7 @@ 1111 1111 1112 1112 * (% style="color:#037691" %)**Downlink Payload (prefix 0x03):** 1113 1113 1114 - (% style="color:blue" %)**0x03 aa bb **(%%)~/~/ Set RO1/RO2 output1093 +**0x03 aa bb **~/~/ Set RO1/RO2 output 1115 1115 1116 1116 1117 1117 ((( ... ... @@ -1126,7 +1126,7 @@ 1126 1126 [[image:image-20220524093724-9.png]] 1127 1127 ))) 1128 1128 1129 - (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**1108 +Device will upload a packet if downlink code executes successfully. 1130 1130 1131 1131 1132 1132 ... ... @@ -1141,7 +1141,7 @@ 1141 1141 1142 1142 * (% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1143 1143 1144 - (% style="color:blue" %)**0x05 aa bb cc dd **(%%)~/~/ Set RO1/RO2 relay with time control1123 +**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1145 1145 1146 1146 1147 1147 This is to control the relay output time of relay. Include four bytes: ... ... @@ -1157,12 +1157,12 @@ 1157 1157 1158 1158 (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status: 1159 1159 1160 -[[image:image-2022 1008095908-1.png||height="364" width="564"]]1139 +[[image:image-20220714135731-1.png||height="406" width="627"]] 1161 1161 1162 1162 1163 -(% style="color:#4f81bd" %)**Fourth/Fifth /Sixth/SeventhBytes(cc)**(%%): Latching time. Unit: ms1142 +(% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms 1164 1164 1165 - (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**1144 +Device will upload a packet if downlink code executes successfully. 1166 1166 1167 1167 1168 1168 **Example payload:** ... ... @@ -1185,6 +1185,7 @@ 1185 1185 1186 1186 1187 1187 1167 + 1188 1188 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1189 1189 1190 1190 ... ... @@ -1192,33 +1192,39 @@ 1192 1192 1193 1193 * (% style="color:#037691" %)**AT Command:** 1194 1194 1195 - (% style="color:blue" %)**AT+VOLMAX **(%%)~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]1175 +**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1196 1196 1197 1197 1198 1198 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1199 1199 1200 - (% style="color:blue" %)**0xA5 aa bb cc **(%%)~/~/ Same as AT+VOLMAX=(aa bb),cc1180 +**0xA5 aa bb cc **~/~/ Same as AT+VOLMAX=(aa bb),cc 1201 1201 1202 1202 1203 1203 1184 + 1204 1204 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1205 1205 1206 1206 1207 1207 * (% style="color:#037691" %)**AT Command:** 1208 1208 1209 - (% style="color:blue" %)**AT+SETCNT=aa,(bb cc dd ee) **1190 +**AT+SETCNT=aa,(bb cc dd ee) ** 1210 1210 1211 - (% style="color:red" %)**aa:**(%%)1: Set count1; 2: Set count2; 3: Set AV1 count1192 +aa: 1: Set count1, 1212 1212 1213 - (% style="color:red"%)**bb cc ddee:**(%%)numberto be set1194 +2: Set count2, 1214 1214 1196 +3: Set AV1 count 1215 1215 1198 +Bb cc dd ee: number to be set 1199 + 1200 + 1216 1216 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):** 1217 1217 1218 - (% style="color:blue" %)**0x A8 aa bb cc dd ee **(%%)~/~/ same as AT+SETCNT=aa,(bb cc dd ee)1203 +**0x A8 aa bb cc dd ee **~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1219 1219 1220 1220 1221 1221 1207 + 1222 1222 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1223 1223 1224 1224 ... ... @@ -1226,139 +1226,36 @@ 1226 1226 1227 1227 * (% style="color:#037691" %)**AT Command:** 1228 1228 1229 - (% style="color:blue" %)**AT+CLRCOUNT **(%%)~/~/ clear all counting1215 +**AT+CLRCOUNT ** ~/~/ clear all counting 1230 1230 1231 1231 1232 1232 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1233 1233 1234 - (% style="color:blue" %)**0x A6 01 **(%%)~/~/ clear all counting1220 +**0x A6 01 ** ~/~/ clear all counting 1235 1235 1236 1236 1237 1237 1224 + 1238 1238 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1239 1239 1240 1240 1241 1241 * (% style="color:#037691" %)**AT Command:** 1242 1242 1243 - (% style="color:blue" %)**AT+COUTIME=60 **(%%)~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)1230 +**AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1244 1244 1245 1245 1246 1246 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1247 1247 1248 - (% style="color:blue" %)**0x A7 aa bb cc **(%%)~/~/ same as AT+COUTIME =aa bb cc,1235 +**0x A7 aa bb cc **~/~/ same as AT+COUTIME =aa bb cc, 1249 1249 1250 1250 ((( 1251 1251 range: aa bb cc:0 to 16777215, (unit:second) 1252 -))) 1253 1253 1254 - 1255 - 1256 -==== 3.4.2.20 Reset save DR DO state ==== 1257 - 1258 - 1259 -* (% style="color:#037691" %)**AT Command:** 1260 - 1261 -(% style="color:blue" %)**AT+RODORET=1 **(%%)~/~/ RODO will close when the device joining the network. (default) 1262 - 1263 -(% style="color:blue" %)**AT+RODORET=0 **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network. 1264 - 1265 - 1266 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):** 1267 - 1268 -(% style="color:blue" %)**0x AD aa ** (%%)~/~/ same as AT+RODORET =aa 1269 - 1270 - 1271 - 1272 -==== 3.4.2.21 Encrypted payload ==== 1273 - 1274 - 1275 -* (% style="color:#037691" %)**AT Command:** 1276 - 1277 -(% style="color:blue" %)**AT+DECRYPT=1 ** (%%)~/~/ The payload is uploaded without encryption 1278 - 1279 -(% style="color:blue" %)**AT+DECRYPT=0 **(%%)~/~/ Encrypt when uploading payload (default) 1280 - 1281 - 1282 - 1283 -==== 3.4.2.22 Get sensor value ==== 1284 - 1285 - 1286 -* (% style="color:#037691" %)**AT Command:** 1287 - 1288 -(% style="color:blue" %)**AT+GETSENSORVALUE=0 **(%%)~/~/ The serial port gets the reading of the current sensor 1289 - 1290 -(% style="color:blue" %)**AT+GETSENSORVALUE=1 **(%%)~/~/ The serial port gets the current sensor reading and uploads it. 1291 - 1292 - 1293 - 1294 -==== 3.4.2.23 Resets the downlink packet count ==== 1295 - 1296 - 1297 -* (% style="color:#037691" %)**AT Command:** 1298 - 1299 -(% style="color:blue" %)**AT+DISFCNTCHECK=0 **(%%)~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default) 1300 - 1301 -(% style="color:blue" %)**AT+DISFCNTCHECK=1 **(%%)~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count. 1302 - 1303 - 1304 - 1305 - 1306 -==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ==== 1307 - 1308 - 1309 -* (% style="color:#037691" %)**AT Command:** 1310 - 1311 -(% style="color:blue" %)**AT+DISMACANS=0** (%%) ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default) 1312 - 1313 -(% style="color:blue" %)**AT+DISMACANS=1** (%%) ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part. 1314 - 1315 - 1316 -* (% style="color:#037691" %)**Downlink Payload **(%%)**:** 1317 - 1318 -(% style="color:blue" %)**0x21 00 01 ** (%%) ~/~/ Set the DISMACANS=1 1319 - 1320 - 1321 - 1322 - 1323 -==== 3.4.2.25 Copy downlink to uplink ==== 1324 - 1325 - 1326 -* (% style="color:#037691" %)**AT Command**(%%)**:** 1327 - 1328 -(% style="color:blue" %)**AT+RPL=5** (%%) ~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100. 1329 - 1330 -Example:**aa xx xx xx xx** ~/~/ aa indicates whether the configuration has changed, 00 is yes, 01 is no; xx xx xx xx are the bytes sent. 1331 - 1332 - 1333 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173747-6.png?width=1124&height=165&rev=1.1||alt="image-20220823173747-6.png"]] 1334 - 1335 -For example, sending 11 22 33 44 55 66 77 will return invalid configuration 00 11 22 33 44 55 66 77. 1336 - 1337 - 1338 - 1339 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173833-7.png?width=1124&height=149&rev=1.1||alt="image-20220823173833-7.png"]] 1340 - 1341 -For example, if 01 00 02 58 is issued, a valid configuration of 01 01 00 02 58 will be returned. 1342 - 1343 - 1344 - 1345 -==== 3.4.2.26 Query version number and frequency band 、TDC ==== 1346 - 1347 - 1348 -* ((( 1349 -(% style="color:#037691" %)**Downlink Payload**(%%)**:** 1350 - 1351 -(% style="color:blue" %)**26 01 ** (%%) ~/~/ Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time. 1352 - 1353 1353 1354 1354 ))) 1355 1355 1356 -**Example:** 1357 1357 1358 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]] 1359 1359 1360 - 1361 - 1362 1362 == 3.5 Integrate with Mydevice == 1363 1363 1364 1364 ... ... @@ -1457,10 +1457,10 @@ 1457 1457 ))) 1458 1458 1459 1459 * ((( 1460 -Connect sensor 's output to DI1-1343 +Connect sensor’s output to DI1- 1461 1461 ))) 1462 1462 * ((( 1463 -Connect sensor 's VCC to DI1+.1346 +Connect sensor’s VCC to DI1+. 1464 1464 ))) 1465 1465 1466 1466 ((( ... ... @@ -1468,11 +1468,11 @@ 1468 1468 ))) 1469 1469 1470 1470 ((( 1471 -[[image:1653968155772-850.png||height="23" width="19"]]**= DI1 **+**/ 1K.**1354 +[[image:1653968155772-850.png||height="23" width="19"]]**= DI1+ / 1K.** 1472 1472 ))) 1473 1473 1474 1474 ((( 1475 -If **DI1+**=**12v**, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal.1358 +If DI1+ = 12v, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal. 1476 1476 ))) 1477 1477 1478 1478 ((( ... ... @@ -1490,10 +1490,10 @@ 1490 1490 ))) 1491 1491 1492 1492 * ((( 1493 -Connect sensor 's output to DI1+1376 +Connect sensor’s output to DI1+ 1494 1494 ))) 1495 1495 * ((( 1496 -Connect sensor 's GND DI1-.1379 +Connect sensor’s GND DI1-. 1497 1497 ))) 1498 1498 1499 1499 ((( ... ... @@ -1523,10 +1523,10 @@ 1523 1523 ))) 1524 1524 1525 1525 * ((( 1526 -Connect sensor 's output to DI1+ with a serial 50K resistor1409 +Connect sensor’s output to DI1+ with a serial 50K resistor 1527 1527 ))) 1528 1528 * ((( 1529 -Connect sensor 's GND DI1-.1412 +Connect sensor’s GND DI1-. 1530 1530 ))) 1531 1531 1532 1532 ((( ... ... @@ -1567,13 +1567,13 @@ 1567 1567 We take the wind speed sensor as an example for reference only. 1568 1568 1569 1569 1570 - (% style="color:blue" %)**Specifications of the wind speed sensor:**1453 +**Specifications of the wind speed sensor:** 1571 1571 1572 - **Red: 12~~24v**1455 +Red: 12~~24v 1573 1573 1574 - **Yellow: 4~~20mA**1457 +Yellow: 4~~20mA 1575 1575 1576 - **Black: GND**1459 +Black: GND 1577 1577 1578 1578 1579 1579 **Connection diagram:** ... ... @@ -1593,7 +1593,6 @@ 1593 1593 1594 1594 [[image:image-20220524100215-9.png]] 1595 1595 1596 - 1597 1597 [[image:image-20220524100215-10.png||height="382" width="723"]] 1598 1598 1599 1599 ... ... @@ -1611,14 +1611,8 @@ 1611 1611 == 4.1 Access AT Command == 1612 1612 1613 1613 1614 -((( 1615 1615 LT supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to LT for using AT command, as below. 1616 -))) 1617 1617 1618 -((( 1619 - 1620 -))) 1621 - 1622 1622 [[image:1653358238933-385.png]] 1623 1623 1624 1624 ... ... @@ -1646,7 +1646,7 @@ 1646 1646 ))) 1647 1647 1648 1648 ((( 1649 -AT+<CMD>=? : 1525 +AT+<CMD>=? : Get the value 1650 1650 ))) 1651 1651 1652 1652 ((( ... ... @@ -1674,11 +1674,11 @@ 1674 1674 ))) 1675 1675 1676 1676 ((( 1677 -AT+APPSKEY: 1553 +AT+APPSKEY: Get or Set the Application Session Key 1678 1678 ))) 1679 1679 1680 1680 ((( 1681 -AT+APPEUI: 1557 +AT+APPEUI: Get or Set the Application EUI 1682 1682 ))) 1683 1683 1684 1684 ((( ... ... @@ -1690,7 +1690,7 @@ 1690 1690 ))) 1691 1691 1692 1692 ((( 1693 -AT+DR: 1569 +AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 1694 1694 ))) 1695 1695 1696 1696 ((( ... ... @@ -1726,7 +1726,7 @@ 1726 1726 ))) 1727 1727 1728 1728 ((( 1729 -AT+NJM: 1605 +AT+NJM: Get or Set the Network Join Mode. (0: ABP, 1: OTAA) 1730 1730 ))) 1731 1731 1732 1732 ((( ... ... @@ -1770,7 +1770,7 @@ 1770 1770 ))) 1771 1771 1772 1772 ((( 1773 -AT+VER: 1649 +AT+VER: Get current image version and Frequency Band 1774 1774 ))) 1775 1775 1776 1776 ((( ... ... @@ -1778,7 +1778,7 @@ 1778 1778 ))) 1779 1779 1780 1780 ((( 1781 -AT+CFS: 1657 +AT+CFS: Get confirmation status of the last AT+SEND (0-1) 1782 1782 ))) 1783 1783 1784 1784 ((( ... ... @@ -1827,42 +1827,40 @@ 1827 1827 ((( 1828 1828 1829 1829 1830 -((( 1831 -(% style="color:blue" %)**If device has not joined network yet:** 1706 +**If device has not joined network yet:** 1832 1832 ))) 1833 -))) 1834 1834 1835 1835 ((( 1836 -(% style="background-color:#dcdcdc" %) **123456**1710 +(% style="background-color:#dcdcdc" %)123456 1837 1837 ))) 1838 1838 1839 1839 ((( 1840 -(% style="background-color:#dcdcdc" %) **AT+FDR**1714 +(% style="background-color:#dcdcdc" %)AT+FDR 1841 1841 ))) 1842 1842 1843 1843 ((( 1844 -(% style="background-color:#dcdcdc" %) **123456**1718 +(% style="background-color:#dcdcdc" %)123456 1845 1845 ))) 1846 1846 1847 1847 ((( 1848 -(% style="background-color:#dcdcdc" %) **AT+NJM=0**1722 +(% style="background-color:#dcdcdc" %)AT+NJM=0 1849 1849 ))) 1850 1850 1851 1851 ((( 1852 -(% style="background-color:#dcdcdc" %) **ATZ**1726 +(% style="background-color:#dcdcdc" %)ATZ 1853 1853 ))) 1854 1854 1855 1855 1856 1856 ((( 1857 - (% style="color:blue" %)**If device already joined network:**1731 +**If device already joined network:** 1858 1858 ))) 1859 1859 1860 1860 ((( 1861 -(% style="background-color:#dcdcdc" %) **AT+NJM=0**1735 +(% style="background-color:#dcdcdc" %)AT+NJM=0 1862 1862 ))) 1863 1863 1864 1864 ((( 1865 -(% style="background-color:#dcdcdc" %) **ATZ**1739 +(% style="background-color:#dcdcdc" %)ATZ 1866 1866 ))) 1867 1867 1868 1868 ... ... @@ -1872,57 +1872,55 @@ 1872 1872 ((( 1873 1873 1874 1874 1875 -((( 1876 -(% style="background-color:#dcdcdc" %)**123456**(%%) ~/~/ Enter Password to have AT access. 1749 +(% style="background-color:#dcdcdc" %)123456(%%) Enter Password to have AT access. 1877 1877 ))) 1878 -))) 1879 1879 1880 1880 ((( 1881 -(% style="background-color:#dcdcdc" %) **AT+FDR**(%%)~/~/Reset Parameters to Factory Default, Keys Reserve1753 +(% style="background-color:#dcdcdc" %) AT+FDR(%%) Reset Parameters to Factory Default, Keys Reserve 1882 1882 ))) 1883 1883 1884 1884 ((( 1885 -(% style="background-color:#dcdcdc" %) **123456**(%%)~/~/Enter Password to have AT access.1757 +(% style="background-color:#dcdcdc" %) 123456(%%) Enter Password to have AT access. 1886 1886 ))) 1887 1887 1888 1888 ((( 1889 -(% style="background-color:#dcdcdc" %) **AT+CLASS=C**(%%)~/~/Set to work in CLASS C1761 +(% style="background-color:#dcdcdc" %) AT+CLASS=C(%%) Set to work in CLASS C 1890 1890 ))) 1891 1891 1892 1892 ((( 1893 -(% style="background-color:#dcdcdc" %) **AT+NJM=0**(%%)~/~/Set to ABP mode1765 +(% style="background-color:#dcdcdc" %) AT+NJM=0(%%) Set to ABP mode 1894 1894 ))) 1895 1895 1896 1896 ((( 1897 -(% style="background-color:#dcdcdc" %) **AT+ADR=0**(%%)~/~/Set the Adaptive Data Rate Off1769 +(% style="background-color:#dcdcdc" %) AT+ADR=0(%%) Set the Adaptive Data Rate Off 1898 1898 ))) 1899 1899 1900 1900 ((( 1901 -(% style="background-color:#dcdcdc" %) **AT+DR=5**(%%)~/~/Set Data Rate1773 +(% style="background-color:#dcdcdc" %) AT+DR=5(%%) Set Data Rate 1902 1902 ))) 1903 1903 1904 1904 ((( 1905 -(% style="background-color:#dcdcdc" %) **AT+TDC=60000**(%%)~/~/Set transmit interval to 60 seconds1777 +(% style="background-color:#dcdcdc" %) AT+TDC=60000(%%) Set transmit interval to 60 seconds 1906 1906 ))) 1907 1907 1908 1908 ((( 1909 -(% style="background-color:#dcdcdc" %) **AT+CHS=868400000**(%%)~/~/Set transmit frequency to 868.4Mhz1781 +(% style="background-color:#dcdcdc" %) AT+CHS=868400000(%%) Set transmit frequency to 868.4Mhz 1910 1910 ))) 1911 1911 1912 1912 ((( 1913 -(% style="background-color:#dcdcdc" %) **AT+RX2FQ=868400000**(%%)~/~/Set RX2Frequency to 868.4Mhz (according to the result from server)1785 +(% style="background-color:#dcdcdc" %) AT+RX2FQ=868400000(%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1914 1914 ))) 1915 1915 1916 1916 ((( 1917 -(% style="background-color:#dcdcdc" %) **AT+RX2DR=5**(%%)****~/~/Set RX2DR to match the downlink DR from server. see below1789 +(% style="background-color:#dcdcdc" %) AT+RX2DR=5(%%) Set RX2DR to match the downlink DR from server. see below 1918 1918 ))) 1919 1919 1920 1920 ((( 1921 -(% style="background-color:#dcdcdc" %) **AT+DADDR=26 01 1A F1**(%%)~/~/Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.1793 +(% style="background-color:#dcdcdc" %) AT+DADDR=26 01 1A F1 (%%) Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1922 1922 ))) 1923 1923 1924 1924 ((( 1925 -(% style="background-color:#dcdcdc" %) **ATZ**(%%)~/~/Reset MCU1797 +(% style="background-color:#dcdcdc" %) ATZ (%%) Reset MCU 1926 1926 1927 1927 1928 1928 ))) ... ... @@ -1932,15 +1932,11 @@ 1932 1932 ))) 1933 1933 1934 1934 ((( 1935 -**~1. Make sure the device is set to ABP mode in the IoT Server.** 1807 +(% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1808 +2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1809 +3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1810 +4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1936 1936 1937 -**2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.** 1938 - 1939 -**3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php? 1940 -dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.** 1941 - 1942 -**4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5** 1943 - 1944 1944 1945 1945 ))) 1946 1946 ... ... @@ -1956,15 +1956,12 @@ 1956 1956 === 4.2.3 Change to Class A === 1957 1957 1958 1958 1959 -((( 1960 -(% style="color:blue" %)**If sensor JOINED:** 1827 +If sensor JOINED 1828 +(% style="background-color:#dcdcdc" %)AT+CLASS=A 1829 +ATZ 1961 1961 1962 -(% style="background-color:#dcdcdc" %)**AT+CLASS=A 1963 -ATZ** 1964 -))) 1965 1965 1966 1966 1967 - 1968 1968 = 5. FAQ = 1969 1969 1970 1970 ... ... @@ -1984,14 +1984,12 @@ 1984 1984 1985 1985 ((( 1986 1986 (% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1987 -(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:http s://www.dropbox.com/sh/g99v0fxcltn9r1y/AADKXQ2v5ZT-S3sxdmbvE7UAa/LT-22222-L/image?dl=0&subfolder_nav_tracking=1]].1852 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1988 1988 (% style="color:blue" %)**Step3**(%%)**:** Open flashloader; choose the correct COM port to update. 1989 1989 1990 1990 1991 -((( 1992 1992 (% style="color:blue" %)**For LT-22222-L**(%%): 1993 1993 Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode. 1994 -))) 1995 1995 1996 1996 1997 1997 ))) ... ... @@ -2048,14 +2048,10 @@ 2048 2048 2049 2049 ((( 2050 2050 (% style="color:blue" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device. 2051 - 2052 - 2053 2053 ))) 2054 2054 2055 2055 ((( 2056 2056 [[image:1653360231087-571.png||height="401" width="727"]] 2057 - 2058 - 2059 2059 ))) 2060 2060 2061 2061 ((( ... ... @@ -2063,23 +2063,21 @@ 2063 2063 ))) 2064 2064 2065 2065 2066 - 2067 2067 ((( 2068 2068 (% style="color:blue" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands: 2069 - 2070 - 2071 2071 ))) 2072 2072 2073 2073 ((( 2074 -(% style="background-color:#dcdcdc" %)**123456** (%%) : Enter Password to have AT access. 2075 -(% style="background-color:#dcdcdc" %)**AT+FDR**(%%) : Reset Parameters to Factory Default, Keys Reserve 2076 -(% style="background-color:#dcdcdc" %)**AT+NJM=0** (%%) : Set to ABP mode 2077 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) : Set the Adaptive Data Rate Off 2078 -(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) : Set Data Rate (Set AT+DR=3 for 915 band) 2079 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000 **(%%) : Set transmit interval to 60 seconds 2080 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) : Set transmit frequency to 868.4Mhz 2081 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26 01 1A F1**(%%) : Set Device Address to 26 01 1A F1 2082 -(% style="background-color:#dcdcdc" %)**ATZ** (%%) : Reset MCU 1930 +(% style="background-color:#dcdcdc" %)123456 (%%) Enter Password to have AT access. 1931 +(% style="background-color:#dcdcdc" %)AT+FDR(%%) Reset Parameters to Factory Default, Keys Reserve 1932 +(% style="background-color:#dcdcdc" %)123456 (%%) Enter Password to have AT access. 1933 +(% style="background-color:#dcdcdc" %)AT+NJM=0 (%%) Set to ABP mode 1934 +(% style="background-color:#dcdcdc" %)AT+ADR=0 (%%) Set the Adaptive Data Rate Off 1935 +(% style="background-color:#dcdcdc" %)AT+DR=5 (%%) Set Data Rate (Set AT+DR=3 for 915 band) 1936 +(% style="background-color:#dcdcdc" %)AT+TDC=60000 (%%) Set transmit interval to 60 seconds 1937 +(% style="background-color:#dcdcdc" %)AT+CHS=868400000(%%) Set transmit frequency to 868.4Mhz 1938 +(% style="background-color:#dcdcdc" %)AT+DADDR=26 01 1A F1(%%) Set Device Address to 26 01 1A F1 1939 +(% style="background-color:#dcdcdc" %)ATZ (%%) Reset MCU 2083 2083 ))) 2084 2084 2085 2085 ... ... @@ -2102,7 +2102,7 @@ 2102 2102 == 5.5 Can i use point to point communication for LT-22222-L? == 2103 2103 2104 2104 2105 -Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AADKXQ2v5ZT-S3sxdmbvE7UAa/LT-22222-L/image?dl=0&subfolder_nav_tracking=1]].1962 +Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 2106 2106 2107 2107 2108 2108 ... ... @@ -2122,23 +2122,7 @@ 2122 2122 2123 2123 2124 2124 2125 -== 5.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? == 2126 - 2127 - 2128 -LT-22222-L built-in relay is NO (Normal Open). User can use an external relay to achieve Normal Close purpose. Diagram as below: 2129 - 2130 - 2131 -[[image:image-20221006170630-1.png||height="610" width="945"]] 2132 - 2133 - 2134 -== 5.8 Can LT22222 save RO state? == 2135 - 2136 -Firmware version needs to be no less than 1.6.0. 2137 - 2138 - 2139 2139 = 6. Trouble Shooting = 2140 - 2141 - 2142 2142 ))) 2143 2143 2144 2144 ((( ... ... @@ -2199,6 +2199,7 @@ 2199 2199 * (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 2200 2200 2201 2201 2043 + 2202 2202 = 8. Packing Info = 2203 2203 2204 2204 ... ... @@ -2217,6 +2217,7 @@ 2217 2217 * Weight / pcs : 170g 2218 2218 2219 2219 2062 + 2220 2220 = 9. Support = 2221 2221 2222 2222 ... ... @@ -2237,3 +2237,5 @@ 2237 2237 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2238 2238 * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 2239 2239 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 2083 + 2084 +
- image-20221006170630-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -486.5 KB - Content
- image-20221008095908-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -41.8 KB - Content